• 제목/요약/키워드: vertical joints

검색결과 255건 처리시간 0.027초

Skirt 제작에 관한 인간공학적 연구 -앉는 동작을 중심으로- (A Study on Making Skirt from the standpoints of Human Engineering)

  • 이년순
    • 대한가정학회지
    • /
    • 제18권4호
    • /
    • pp.31-39
    • /
    • 1980
  • The basic pattern of skirt should be functional in addition to be fit the body. The author paid special attention to the expansion and contraction of the shell which were made the lower trunk and thigh caused by sitting motions. The replicas of the shell were taken by using a gypsum method on 1 female under 4 standardized motions; standing motion, (basic motion), sitting on the chair with flextion 90' at the hip and the knee joints sitting with dropping knees, and sitting with benting legs side wards. Those replicas obtained were developed to the patterns and changes in shape and area of those were measured. Typical displacement and transformation of the shell surface patterns were showed geographycally fig 5-1 to 5-4. mean values of expansion and constriction were obtained by measuring the shell surface on 60 female under the 4 motions. the mean values of it were showed numerically in Table 1-1 to 1-3. The following results were obtained; 1. Vertical constriction of front of the shell were observed near sulcus in guinalis, and vertical extension were near the knees. Horizontal extension were observed near the thighs and the knees. 2. Vertical constrictions of the back of the shell were observed near the knees. It seemed to be influnced the flexion angles of knee points. vertical extension were near gluteus and thighs. Horizontal constriction were small, and horizonlal extension were near gluteus. 3. The high rates of constriction and extension were found near sulcus in guinalis, glutes, and knees. 4. The rates of constriction and extension on the waist line were very low. 5. The highest values of constriction and extension were found in hip and knees.

  • PDF

시스템 동바리 수직재와 수평재 연결부의 휨강도와 회전 강성 평가 (Flexural Strength and Rotational Stiffness Estimation of Joint between Vertical and Horizontal Members in System Support)

  • 원정훈;이형도;최명기;박만철
    • 한국안전학회지
    • /
    • 제33권4호
    • /
    • pp.46-53
    • /
    • 2018
  • This study examined the maximum resistant moment and nonlinear rotational stiffness of wedge joint between the vertical and horizontal members of system supports. To examine the maximum resistant moment and propose the nonlinear rotation stiffness of wedge joint, 6 specimens were tested and additional 3 specimens, where the horizontal member was welded to the vertical member, were tested to compare the moment capacity of wedge joints. The average maximum moment in the tested wedge joint was 1.183 kNm which represented about 70 % of the maximum moment developed in the welded specimens. And, as simulating nonlinear rotational stiffness of the wedge joint, a tri-linear model was suggested. The rotational stiffness was estimated as 23.095 kNm/rad in first stage, 7.945 kNm/rad in second stage, and 3.073 kNm/rad in third stage. For the failure mode, the specimen with the wedge joint showed the failure of joint between vertical and horizontal members. However, the specimen with welded joint represented the yielding of horizontal members.

강섬유 보강 철근콘크리트 전단이음부의 피로거동에 대한 실험적 연구 (A Experimental Study on Fatigue Behavior of Joints between RC and RSFC subjected to shear)

  • 강보순
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.389-396
    • /
    • 2000
  • Fatigue behavior of shear joints between combined reinforced concrete(RC) and reinforced steel fiber concrete(RSFC) specimens has been experimentally investigated. Experimental parameters used are the amount of steel fiber and the type of shear joint. 6 specimens have been tested under static load, and 8 specimens have been subjected to the fatigue load in a range of 50% and 5 % of the ultimate static load. The purpose of this research is to propose an empirical formula for fatigue shear behavior of combined RC and RSFC structures on the basic of experimental result. It can be observed from experimental result that addition of steel fibers to concrete specimen increases the static ultimate load by approximately 25%, enhances the fatigue behavior, and also reduces vertical and lateral displacements at the shear joint for a given load cycle after the occurrence of first crack.

  • PDF

낙하 충격을 받는 다점 구속 장치를 착용한 헬기 승무원의 상해도 평가에 관한 연구 (A Study on the Injury Assessment of Helicopter's Crew with Multi Point Restraint System under Drop Impact)

  • 이중현;이영신
    • 대한기계학회논문집A
    • /
    • 제33권6호
    • /
    • pp.590-599
    • /
    • 2009
  • In this paper, a method of modeling seat belts on crew seat during dynamic seat testing was studied. The body segments of the occupant were modeled with joints. The joints consisted with various stiffnesses, dampings, and frictions. Three types of seat belt restraint systems were investigated. The analysis for on the injury assessment of helicopter's crew under drop impact was conducted. The effectiveness of the seat belt system for crashworthiness and safety was evaluated. As the results of impact analysis, head, neck and spine of the crew can be easily damaged in the vertical direction more than the longitudinal direction. Based on the verified model, behavior of human body was studied with three-point restraint systems. The displacement and injury level of the 12-point restraint system was the smallest.

철근콘크리트 구조물 내의 철근을 활용한 피뢰설비 인하도선의 설치방법에 관한 연구 (A Study on the Installation Method of Down Conductors of the Lightning Protection System, using Rebar in Reinforced Concrete Structures)

  • 이영철;이주철
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.101-107
    • /
    • 2013
  • IEC Standards on lightning protection system specify the use of natural components as down conductors. This paper provides an analysis of problems revealed from our field investigation and survey conducted for the relevant experts in the construction site where natural components are used as down conductors. It also considers a suitable condition for installing natural components as down conductors in accordance with the latest version of the standard. As a result, when rebars of reinforced concrete are used as down conductors, vertical bars consisting of rebars of which thickness is not less than D13($127mm^2$) should be connected by welding, clamps or bound joints, using appropriate connection components conforming to IEC Standards. The lashed joints, however, shall not be applied for down conductors.

The Benefits of Stick Walking: Evaluation at Ankle, Knee and Hip Joints

  • ;;박기원;윤훈용;박성하
    • 대한인간공학회지
    • /
    • 제24권4호
    • /
    • pp.63-71
    • /
    • 2005
  • A laboratory study was performed to evaluate the effects of an aid(i.e. stick) on joint loadings. Six healthy young participants were recruited from Virginia Tech student population. Each participant has performed three normal walking and three stick walking trials. Normalized and integrated, ground reaction forces(GRFs) and joint moments were measured at ankle, knee, and hip joints from kinematic and kinetic data. The result suggests that stick walking significantly reduces vertical ground reaction force and joint moments at ankle and knee compared to normal walking.

Z형 강널말뚝의 오염물질 차단효과 (The permeability charateristic of Z-type sheet pile joints under water sealing conditions)

  • 홍승서;이용수;정하익
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1283-1288
    • /
    • 2009
  • In general steel sheet piles are used in the containment system, which are vertical barrier systems for waste disposal and landfill purposes, and roads in excavation for temporary structure. This paper presents case study of the use of an interlocking sheet pile for water and containment. Cut-off Z-type sheet pile joints are investigated to determine their permeability from the field test. Four different joint sealing materials are used in field test. The results showed joint permeability is significant time-dependent and joint-dependent. These are explored and conclusions on permeability characteristics of different sealants are noted. A case study gives a design example as well as suggestion on permeability and water tightness can be implemented in using the sheet pile barrier in civil and environment works. From the test results, the effective sealing programs of sheet pile interlocks are suggested.

  • PDF

그라우팅 강화터널의 설계 특성치 산정에 관한 연구 (Estimation of the Anisotropic Material Properties of Rock Masses with Permeation Grouting)

  • 이준석;방춘석;최일윤;엄주환
    • 자연, 터널 그리고 지하공간
    • /
    • 제1권1호
    • /
    • pp.67-80
    • /
    • 1999
  • The Grout-reinforcement technique which is widely used during the excavation of a shallow or an endangered tunnel can be classified into a couple of groups according to the properties and injection methods of the grout. The reinforcement design will, therefore, take a different approach based on the grouting method under consideration. However, the injection procedure is mainly performed by the experience of the foreman rather than engineering judgement , specifically the permeation grouting through the rock joints and its reinforcement effect Is not fully under-stood during the design stage, In this study, the anisotropic material properties of the grout-reinforced rock masses are derived from the concept of composite materials and the effect of intact rock, vertical grouting and permeation grouting is, therefore, fully accounted for. Through the parametric studies on the characteristics of rock joints, intact rock and grouting materials, various case studies have been considered. The results, illustrated via the design charts, can be directly used during the reinforcement design.

  • PDF

Three-dimensional analysis of stress and strain transmission through line joints of spatial linkage of plates

  • Rosenhouse, G.;Rutenberg, A.;Goldfarb, Y.R.
    • Structural Engineering and Mechanics
    • /
    • 제3권1호
    • /
    • pp.11-23
    • /
    • 1995
  • The examined model consists of two substructures linked by a right angle rigid line joint. One element is a wall loaded externally along its upper edge by an uneven vertical load. The other element, defined as a plate, is not loaded. Stresses and displacements in the vicinity of the joint are analysed, considering the lateral distribution which leads to three-dimensional effects. The proposed solution combines classical approach with numerical means, using appropriate stress distribution polynomial functions along the joint. Space structure constructions supply cases of interest.

철근콘크리트 경사기둥-보 접합부의 거동 (Behavior of Reinforced Concrete Inclined Column-Beam Joints)

  • 권구정;박종욱;윤석광;김태진;이정윤
    • 콘크리트학회논문집
    • /
    • 제24권2호
    • /
    • pp.147-156
    • /
    • 2012
  • 최근 몇 년간 보-기둥 접합부에 영향을 줄 수 있는 경사기둥을 포함한 비정형 구조 시스템을 가진 초고층 빌딩이 증가하고 있다. 경사기둥-보 접합부에 외력이 작용 시 전단과 휨 모멘트의 분포가 정형화된 보-기둥 접합부와 상이하여 접합부의 파괴모드, 전단강도, 연성능력 및 에너지소산능력이 변화할 가능성이 크다. 이 연구에서는 6개의 철근콘크리트 경사기둥-보 접합부($90^{\circ}$, $67.5^{\circ}$, $45^{\circ}$) 실험을 수행하고 결과를 분석하였다. 실험 결과에 의하면 경사기둥-보 접합부에서 비대칭 파괴가 발생하였으며 수직기둥-보 접합부에 비해서 최대하중과 에너지소산능력이 감소하는 것으로 나타났다. 이것은 경사기둥으로 인해 발생되는 접합부의 상이한 모멘트 분포와 압축력만 받는 수직기둥과 다르게 경사기둥이 압축력뿐 아니라 인장력도 작용하기 때문이다.