• Title/Summary/Keyword: vertical frame

Search Result 449, Processing Time 0.031 seconds

Vertical Search Based on Multiple Entity-centric Unification (다중 개체 중심적 통합 방식의 버티컬 검색 - 학술 연구 정보 분석 서비스에의 적용 사례를 중심으로 -)

  • Jung, Han-Min;Lee, Mi-Kyoung;Sung, Won-Kyung;You, Beom-Jong
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.253-256
    • /
    • 2009
  • This paper describes a vertical search system based on multiple entity-centric unification, which enables to deal with the search queries including multiple domains. To implement the system, we introduced two search technologies; one is for merging service components dynamically according to the entities in the search keywords, and the other is for searching fields with appropriate entities. Our current system includes about 453,000 overseas journal papers for article information search and two entity types; research topic and researcher.

  • PDF

Fragility assessment of RC-MRFs under concurrent vertical-horizontal seismic action effects

  • Farsangi, Ehsan Noroozinejad;Tasnimi, Abbas Ali;Mansouri, Babak
    • Computers and Concrete
    • /
    • v.16 no.1
    • /
    • pp.99-123
    • /
    • 2015
  • In this study, structural vulnerability of reinforced concrete moment resisting frames (RC-MRFs) by considering the Iran-specific characteristics is investigated to manage the earthquake risk in terms of multicomponent seismic excitations. Low and medium rise RC-MRFs, which constitute approximately 80-90% of the total buildings stock in Iran, are focused in this fragility-based assessment. The seismic design of 3-12 story RC-MRFs are carried out according to the Iranian Code of Practice for Seismic Resistant Design of Buildings (Standard No. 2800), and the analytical models are formed accordingly in open source nonlinear platforms. Frame structures are categorized in three subclasses according to the specific characteristics of construction practice and the observed seismic performance after major earthquakes in Iran. Both far and near fields' ground motions have been considered in the fragility estimation. An optimal intensity measure (IM) called Sa, avg and beta probability distribution were used to obtain reliable fragility-based database for earthquake damage and loss estimation of RC buildings stock in urban areas of Iran. Nonlinear incremental dynamic analyses by means of lumped-parameter based structural models have been simulated and performed to extract the fragility curves. Approximate confidence bounds are developed to represent the epistemic uncertainties inherent in the fragility estimations. Consequently, it's shown that including vertical ground motion in the analysis is highly recommended for reliable seismic assessment of RC buildings.

Performance-based plastic design for seismic rehabilitation of high rise frames with eccentric bracing and vertical link

  • Karimi, Rouhina;Rahimi, Sepideh
    • Earthquakes and Structures
    • /
    • v.17 no.6
    • /
    • pp.623-633
    • /
    • 2019
  • A large number of available concrete buildings designed only considering gravity load that require seismic rehabilitation because of failure to meet plasticity criteria. Using steel bracings are a common type of seismic rehabilitation. The eccentric bracings with vertical link reduce non-elastic deformation imposed on concrete members as well as elimination of probable buckling problems of bracings. In this study, three concrete frames of 10, 15, and 20 stories designed only for gravity load have been considered for seismic improvement using performance-based plastic design. Afterwards, nonlinear time series analysis was employed to evaluate seismic behavior of the models in two modes including before and after rehabilitation. The results revealed that shear link can yield desirable performance with the least time, cost and number of bracings of concrete frames. Also, it was found that the seismic rehabilitation can reduce maximum relative displacement in the middle stories about 40 to 80 percent. Generally, findings of this study demonstrated that the eccentric bracing with vertical link can be employed as a suitable proxy to achieve better seismic performance for existing high rise concrete frames.

Design of the Real Time Disparity System using Vertical Strip Structure (수직축 Strip구조를 이용한 실시간 Disparity시스템의 설계)

  • 강봉순;양훈기
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.4
    • /
    • pp.91-100
    • /
    • 2004
  • In this paper, we propose the method that analyzes the depth of object using 2 images in the disparity algorithm. It also presents the design and implementation of the proposed method for a real time processing. The proposed system uses the vertical strip structure for calculating similar pixel numbers for the processing and converts the depth of object into gray scale images in order to be displayed on various display devices. The hardware using the proposed method is operating with 30 frames/sec and verified by using the Altera APEX 20K1000EBC652-3. The proposed method is also Implemented into It by using the Hynix 0.35${\mu}{\textrm}{m}$ CB35 ASIC library and 256PQFP package.

Seismic performance of a resilient low-damage base isolation system under combined vertical and horizontal excitations

  • Farsangi, Ehsan Noroozinejad;Tasnimi, Abbas Ali;Yang, T.Y.;Takewaki, Izuru;Mohammadhasani, Mohammad
    • Smart Structures and Systems
    • /
    • v.22 no.4
    • /
    • pp.383-397
    • /
    • 2018
  • Traditional base isolation systems focus on isolating the seismic response of a structure in the horizontal direction. However, in regions where the vertical earthquake excitation is significant (such as near-fault region), a traditional base-isolated building exhibits a significant vertical vibration. To eliminate this shortcoming, a rocking-isolated system named Telescopic Column (TC) is proposed in this paper. Detailed rocking and isolation mechanism of the TC system is presented. The seismic performance of the TC is compared with the traditional elastomeric bearing (EB) and friction pendulum (FP) base-isolated systems. A 4-storey reinforced concrete moment-resisting frame (RC-MRF) is selected as the reference superstructure. The seismic response of the reference superstructure in terms of column axial forces, base shears, floor accelerations, inter-storey drift ratios (IDR) and collapse margin ratios (CMRs) are evaluated using OpenSees. The results of the nonlinear dynamic analysis subjected to multi-directional earthquake excitations show that the superstructure equipped with the newly proposed TC is more resilient and exhibits a superior response with higher margin of safety against collapse when compared with the same superstructure with the traditional base-isolation (BI) system.

Utilization of wheel derailment test facilities (차륜탈선 시험설비의 활용방안)

  • Ham, Young-Sam;You, Won-Hee
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1128-1133
    • /
    • 2011
  • This is a testing equipment system to analyze variation of creep force according to wheel-rail tread profile, running speed of vehicle, vertical and lateral force, wheel/rail contact point, attack angle and so on. The creep force affect vehicle derailment, especially climbing derailment. This system is composed of main frame, wheelset and rail disks driver, hydraulic actuator, controller, environmental chamber, safety system and so on.

  • PDF

Influence of SMAs on the attenuation of effects of P-Δ type in shear frames

  • Corbi, Ottavia
    • Steel and Composite Structures
    • /
    • v.3 no.6
    • /
    • pp.403-420
    • /
    • 2003
  • In the paper one investigates the benefits deriving from the introduction of SMA provisions in a structure subject to dynamic excitation and vertical loads. At this purpose one considers a multi-degree-of-freedom (mdof) shear elastic-plastic frame and designs couples of super-elastic SMA tendons to be placed at critical locations of the structure. Particular attention is focused on the reduction of $P-{\Delta}$ effects.

Behavior of the Wall System with Transfer Girder and Columns. (상부 전단벽 하부 프레임 구조를 갖는 시스템의 수직하중에 대한 거동)

  • 홍성걸;문종우;박홍근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.456-461
    • /
    • 1998
  • This paper presents the results from a combination of strut-and-tie model and analytical study that investigated the ultimate strength of wall system with frame supports. Strut-and-tie models show reasonable force flows and upper bound solution is compared to the results from FEM analysis. The results shows that two main parameters - transfer girder depth and column width - yield good estimation of the ultimate strength of the system. Vertical and horizontal reinforcements of the transfer girder add few strength to the whole system. The proposed design strength formula shows good agreement with the results from FEM analysis.

  • PDF

Realization of a High Speed Optic Scanner for Infrared Thermal Imaging (적외선 체열촬영시스템을 위한 고속 광주사기의 구현)

  • 이수열
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.43-48
    • /
    • 1995
  • A high speed optic scanner capable of 16 frames/sec imaging has been developed for the realization of the infrared thermal Imaging system with a single element infrared sensor. The high speed optic scanner is composed of a rotating polygon mirror for horizontal scanning, a flat mirror mounted on a galvanometer for vertical scanning, and a spherical mirror. It has been experimentally found that the optic scanner is capable of 16 framesllsec imaging with the frame matrix size of 256 x 64.

  • PDF

An experimental study on the Free stream turbulence of Floating body with vertical plate (연속부착된 수직평판을 갖는 부유구조물 후류의 자유유동 난류강도에 대한 실험적연구)

  • Kim, Ho;Oh, Kyoung-Gun;Gim, Ok-Sok;Lee, Gyoung-Woo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2007.12a
    • /
    • pp.125-126
    • /
    • 2007
  • In this paper, the floating body with vertical plate is introduced with a study on the flow patterns and characteristics in around the floating body by using 2 frame particle tracking method. This paper introduce an analysis method to predict the characteristics if flow around the neighboring fields if Floating Body with vertical plate in order to investigate a high performance model. Flow visualization has conducted in a drcu1ating water channel by a high speed camera and etc. Flow phenomena according to turbulence intensity distribution and flow separation around the floating body with vertical plate were obtained by two-dimensional PIV system.

  • PDF