• 제목/요약/키워드: vertical condensation

검색결과 88건 처리시간 0.045초

열연화시킨 근관충전방법에 따른 근단폐쇄성에 관한 연구 (A COMPARISON OF THE APICAL SEALING ABILITY OF OBTURATION TECHNIQUES BY THERMALLY SOFTENED GUTTA PERCHA)

  • 백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.607-617
    • /
    • 1998
  • The purpose of this study was to evaluate the apical sealing ability of lateral condensation method, vertical condensation method, and MicroSeal obturation system. Sixty-four extracted anterior teeth were instrumented to #40 using Profile. Three groups of 20 teeth were obturated by lateral condensation technique, vertical condensation technique, and and MicroSeal obturation system. Control group were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were ground horizontally at 1,5mm(level 1), 2.5mm(level 2), and 3.5mm(level 3) from the anatomic apex and examined with a stereomicroscope at X40 magnification. The photographs were taken a at X40 magnification of the filling in each level and scanned. The leakage area, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was evaluated by calculating the ratio of thearea of the resin to the total area of the canal and was analyzed statistically. The results were as followed: 1. Vertical condensation group had significantly higher percentage of the area which was obturated by gutta percha than other two technique at each level. 2. At the level 1, there was the greatest leakage in the lateral condensation group, but there was no statistically significant(P>0.05) 3. At the level 2, there was the least leakage in the MicroSeal group, and the most leakage in the lateral condensation group. There was statistically significant difference between the MicroSeal group and the lateral condensation group(P<0.05). 4. At the level 3, there was least leakage in the vertical condensation group, and the most leakage in the lateral condensation group. There was statistically significant difference between the vertical condensation group and the lateral condensation group(P<0.05).

  • PDF

Analysis of Experiments for Vertical In-Tube Steam Condensation with Noncondensable Gases Using the Modified RELAP5/MOD3.2 Code

  • Park, Hyun-Sik;No, Hee-Cheon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 춘계학술발표회요약집
    • /
    • pp.109-109
    • /
    • 1999
  • The standard RELAP5/MOD3.2 code was modified using the non-iterative modeling. which is developed to simulate steam condensation in the presence of noncondensable gases ill a vertical tube. The modified RELAP5/MOD3.2 code was used to simulate two kinds of vertical in-tube experiments involving the condensation phenomenon in the presence of noncondensable gases. The modeling capabilities of the modified RELAP5/MOD3.2 codc as well as the standard code for the condensation in the presence of noncondensable gases are assessed using two PCCS condensation experiments and four reflux condensation experimcnts. The modified RELAP5/MOD3.2 code gives good prediction over the data of both PCCS condensation and reflux condensation experiments

  • PDF

Gutta-percha를 이용(利用)한 세가지 근관충전법(根管充塡法)의 부근관충전(副根管充塡) 효과비교(效果比較) (A COMPARISON OF THE ACCESSORY CANAL FILLING EFFECTS OF THE THREE ROOT CANAL FILLING METHODS WITH GUTTA-PERCHA)

  • 안성호;조규징
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.121-133
    • /
    • 1989
  • In order to compare the accessory canal filling effects of the three root canal filling methods with gutta-percha, the author fabricated artificial root canal mold with the first and second accessory canals of chrome-cobalt alloy. After the artificial root canal was filled with gutta-percha by lateral condensation, vertical condensation and low-temperature thermoplasticized gutta-percha injection-molded method, twenty five times respectively, the gutta-percha forced into the first and second accessory canals were measured with caliper for length. The results were as follows: 1. The filling in both accessory canals was most effective in low-temperature thermoplasticized gutta-percha injection-melded method followed in such order as: vertical condensation method and lateral condensation method (p < 0.01). 2. The filling effect of the second accessory canal was more or less higher than that of the first one (p < 0.05). 3. Low-temperature thermoplasticized gutta-percha injection-molded method was fastest in time needed for root canal filling followed by lateral condensation method and vertical condensation method.

  • PDF

등온 수직벽의 자연대류 막응축 모델에 관한 비교분석 (Comparative Analysis of Models for Free Convective Film Condensation on an Isothermal Vertical Wall)

  • 성현찬;김경훈
    • 대한기계학회논문집B
    • /
    • 제24권10호
    • /
    • pp.1380-1387
    • /
    • 2000
  • The existing theoretical models for steady two-dimensional free convective laminar film condensation of pure saturated or superheated vapor under atmospheric pressure on isothermal vertical wall have been reviewed. To investigate the effects such as inertia, thermal convective and liquid-vapor interface shear stress, the models of constant or variable properties in liquid film for condensation of saturated vapor are compared in detail with Nusselt model. Also, for condensation of superheated vapor, the effects of superheated temperature and variable properties in liquid and vapor layers are examined and then a new correlation is proposed to predict the heat transfer. The results are in good agreement with the Shang's correlation within 2% errors.

수직관 내 순수 증기의 층류 액막 응축 모델 (Laminar Film Condensation Model of Pure Steam in a Vertical Tube)

  • 김동억
    • 한국유체기계학회 논문집
    • /
    • 제17권3호
    • /
    • pp.33-40
    • /
    • 2014
  • In this study, a new model for calculating the liquid film thickness and condensation heat transfer coefficient in a vertical condenser tube is proposed by considering the effects of gravity, liquid viscosity, and vapor flow in the core region of the flow. In order to introduce the radial velocity profile in the liquid film, the liquid film flow was regarded to be in Couette flow dragged by the interfacial velocity at the liquid-vapor interface. For the calculation of the interfacial velocity, an empirical power-law velocity profile had been introduced. The resulting liquid film thickness and heat transfer coefficient obtained from the proposed model were compared with the experimental data from other experimental study and the results obtained from the other condensation models. In conclusion, the proposed model physically explained the liquid film thinning effect by the vapor shear flow and predicted the condensation heat transfer coefficient from experiments reasonably well.

등온 수직벽의 자연대류 막응축 모델에 관한 비교분석 (Comparative Analysis of Models for Free Convective Film Condensation on an Isothermal Vertical Wall)

  • 성현찬;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.31-36
    • /
    • 2000
  • The existing theoretical models for steady two-dimensional free convective laminar film condensation or pure saturated or superheated vapor under atmospheric pressure on isotheraml vertical wall have been reviewed. To investigate the effects of inertia, thermal convective and liquid-vapor interface shear stress, the models of constant or variable properties in liquid film for condensation of saturated vapor are compared in detail with Nusselt model. Also, for condensation of superheated vapor the effects of superheated temperature and variable properties in liquid and vapor layer are examined and then new correlation is proposed to predict the heat transfer. The results are in good agreement with the Shang's correlation within 2% errors.

  • PDF

근광충전방법에 따른 post space형성후의 근관폐쇄성에 관한 실험적 연구 (CORONAL DYE PENETRATION OF THE APICAL FILLING MATERIALS AFTER POST SPACE PREPARATION)

  • 윤수한;권오양
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.812-817
    • /
    • 1995
  • Endodontically treated teeth are usually restored for crown protection, aesthetics, and prevention of root canal recontamination. Restoration of these teeth, however, often requires intracanal posts. Various depths and techniques have been recommended for the preparation of post space. Therefore the purpose of this study was to evaluate the effect that pst preparation has on the coronal seal by linear dye penetration of root canals obturated by lateral condensation, vertical condensation, and thermafil techniques. Forty canals of roots of incisors and canines were cleaned and shaped with the use of a step-back technique. Thirty canals were obturated, 10 each with lateral, vertical, and thermafil techhniques. Five root canals were obturated without a root canal sealer and served as positive controls. Another five root canals were obturated, and their coronal half was sealed with sticky wax and served as negative controls. The apical 5 to 6mm of the filling materials were exposed to india ink for 48 hours. The depth of dye penetration was measured in all groups and statistically analyzed (ANOVA). The results were as follows. 1. The apical plugs in the thermafil groups had the highest degree of coronal dye leakage. 2. The group filled by vertical condensation technique had the lowest degree of coronal dye leakage. 3. No significant statistical difference was found in the amount of coronal dye leakage in canals filled by lateral condensation versus those filled by the veritcal condensation technique. 4. Significant statistical differences in coronal dye penetration were found between the canals filled by thermafil and those filled by the lateral or vertical condensation techniques (p<0.05).

  • PDF

중대사고 해석코드 MELCOR 1.8.6의 비응축성기체 존재 시 응축열전달 모델 평가 (Assessment of the MELCOR 1.8.6 condensation heat transfer model under the presence of noncondensable gases)

  • 유지민;이동훈;윤병조;정재준
    • 에너지공학
    • /
    • 제25권2호
    • /
    • pp.1-20
    • /
    • 2016
  • 원전의 설계기준사고 및 중대사고 해석에서 응축열전달 모델은 매우 중요하며, 특히 피동냉각계통의 개발이 활발히 진행됨에 따라 그 중요성이 더욱 부각되었다. 그런데, 원자로건물 내부에서와 같이 비응축성기체가 존재하는 경우 응축열전달은 현저히 감소하므로 원전 안전해석에서 이를 고려한 응축열전달 모델이 주목받고 있다. 본 연구에서는 냉각재상실사고 등이 발생하는 경우 원자로건물 내부의 상황과 유사한 열수력 조건에서 수행된 응축열전달 실험자료를 이용하여 중대사고 해석코드 MELCOR 1.8.6의 응축열전달 모델을 평가하였다. 실험조건을 응축면의 형상에 따라 네 가지(수직평판, 수직관 외벽, 수직관 내벽, 수평관 내벽)로 분류하였고, 각 분류별 실험들을 MELCOR 코드로 해석하였다. 해석결과, 수직관 내벽을 제외한 나머지 조건에서 MELCOR 코드가 응축열전달을 전체적으로 저 예측하여 개선이 필요한 것으로 나타났다.

내부와 외부에서 증발과 응축이 발생하는 수직관에 대한 유동 해석 (Film Flow Analysis for a Vertical Evaporating Tube with Inner Evaporation and Outer Condensation)

  • 박일석
    • 대한기계학회논문집B
    • /
    • 제32권8호
    • /
    • pp.621-628
    • /
    • 2008
  • A numerical study for the flow, heat and mass transfer characteristics of the evaporating tube with the films flowing down on both the inside and outside tube walls has been carried out. The condensation occurs along the outside wall while the evaporation occurs at the free surface of the inside film. The transport equations for momentum and energy are parabolized by the boundary-layer approximation and solved by using the marching technique. The calculation domain of 2 film flow regions (evaporating and condensation films at the inside and outside tube wall respectively) and tube wall is solved simultaneously. The coupling technique for the problem with the 3 different regions and the 2 interfaces of them has been developed to calculate the temperature field. The velocity and temperature fields and the amount of the condensed and evaporated mass as well as the position where the evaporating film is completely dried out are successfully predicted for various inside pressures and inside film inlet flow rates.