• 제목/요약/키워드: ventilation wind

검색결과 220건 처리시간 0.029초

Exceedance probability as a tool to evaluate the wind environment of urban areas

  • Bady, Mahmoud;Kato, Shinsuke;Ishida, Yoshihiro;Huang, Hong;Takahashi, Takeo
    • Wind and Structures
    • /
    • 제11권6호
    • /
    • pp.455-478
    • /
    • 2008
  • The present study aims to estimate the wind ventilation performance for pedestrian level domains from the air quality point of view. Three typical models of a dense urban area were considered and numerically simulated in order to examine the effects of the geometry of such models on wind flow characteristics, which in turn affect the air quality, within the pedestrian domain of a street canyon located within this area. The calculated flow fields were employed to estimate the exceedance probabilities within the study domain using a new approach: air exchange rate within the domain. The study has been applied to nine cities in Japan: Tokyo, Osaka, Sapporo, Niigata, Fukuoka, Nagoya, Sendai, Yokohama, and Kyoto, based on their mean wind velocity data. The results demonstrated that the exceedance probability analysis of the pedestrian wind environment could be a valuable tool during the design stage of inhabited areas for the evaluation of pollutant-removal efficiency by the applied wind. Also, the calculated probabilities demonstrated substantial dependence on both the geometry of building arrays and the wind conditions of the nine cities.

외기의 풍속 및 풍향에 따른 옥내저탄장 내부 유동 해석 (Flow Analysis indoor Coal Storage Shed due to Wind Velocity and Wind Direction of Ambient Air)

  • 김태권;조목량;배영완;김지원
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.538-545
    • /
    • 2020
  • 화력발전소의 옥외 저탄장은 주변 지역의 환경오염 문제로 인하여 국내외적으로 옥내 저탄장으로 전환되고 있는 추세이다. 하지만 옥내 저탄장의 경우 실내의 석탄 비산과 유해가스의 발생이 문제가 되고 있다. 본 연구는 옥내 저탄장 내부를 외기의 풍속 및 풍향에 따른 내부 유동장 특성과 환기량을 분석하여 환기 방안을 제시하고자 한다. 옥내 저탄장 내부에서의 실제 유동 측정 정보를 기반으로 하여 CFD 해석을 수행하였다. 외기 풍향이 동풍일 때 풍속이 6 m/s인 경우와 2 m/s인 경우를 비교해본 결과는 6 m/s일 때 Monitor louver로 배출되는 유속이 2 m/s일 때보다 빠르며 재순환 영역이 뚜렷하게 나타났다. 또한 외기 풍향이 서풍일 경우에도 동풍과 경향이 비슷함을 확인하였다. 풍속에 따른 환기량을 확인한 결과는 풍속이 6 m/s인 경우에는 환기 횟수는 13.1회, 2 m/s인 경우에는 4.4회의 환기가 가능하다. 풍속이 2 m/s인 경우에 일반 공장의 시간당 필요 환기 횟수에 미치지 못하여 다소 개선이 필요한 실정이다.

신축아파트 환기방식에 따른 실내공기질 변화와 이에 대한 시뮬레이션 및 건강 위해성 평가 (Simulation and Health Risk Evaluation of Indoor Air Quality Changes by Ventilation System in New Apartment)

  • 포위;정재연;정인수
    • 한국농촌건축학회논문집
    • /
    • 제23권4호
    • /
    • pp.38-45
    • /
    • 2021
  • In this study, air quality conditions were identified and analyzed in real time, at the same time, living habits and ventilation methods were maintained in the daily life of residents, and thus, this present study focuses on the lifestyles of residents. Previous studies showed a difference from this study, focusing on the study on the effects of changes in indoor air quality on human health according to the indoor air quality process test standards of the Ministry of Environment. Formaldehyde concentrations exceeded all ventilation standards, but satisfied the organic standards of the Ministry of Environment when ventilation devices and air purifiers were activated. As such, it was investigated that a large amount of formaldehyde emission in the condo is initially ventilated, but a certain concentration is maintained. The change in PM2.5 concentration according to the ventilation method showed a clear difference. As a result of simulating indoor air flow during natural ventilation, the effects of wind speed and wind direction affect the flow rate of indoor air, and indoor polluted air is stagnant even in the presence of wind and is not completely discharged. When the risk assessment results are averaged on the day of measurement, the trends of change between adults and children are almost equivalent, but the results address that children are more sensitive to risk than adults.

환기 중인 온실의 공기유동에 관한 실험적 연구 (Experiment on Airflow in Ventilated Greenhouse)

  • 윤남규;김문기
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.429-433
    • /
    • 1999
  • The experiment was conducted to predict air movements and to analyzxe the ventilation characteristics in ventilated greenhouse. Relatively high wind velocity was checked near windward inlet, but near leeward outlet and indoor very low wind velocity near to zero was checked . Despite of much influent air, indoor temperature was watched as high values uniformly due to inadequate air flow in greenhouse and low ventilation efficiency of the greenhouse.

  • PDF

대구지역의 국지순환풍의 환기경로 및 대기오염수송에 관한 수치모의 (Numerical Simulation on the Wind Ventilation Lane and Air Pollutants Transport due to Local Circulation Winds in Daegu Districts)

  • 구현숙;김해동
    • 한국지구과학회지
    • /
    • 제25권6호
    • /
    • pp.418-427
    • /
    • 2004
  • 최근 도시기후를 고려한 도시계획이 많은 나라에서 실용화되고 있다. 도시기후의 고려는 주로 도시의 바람 길 조성이라는 개념으로 구체화되고 있다. 도시의 바람 길 조성은 주로 하계에 도시지역의 열적 쾌적성을 개선하는 것을 목표로 한다. 아울러, 과학적 조사에 근거하여 도시의 단지계획을 합리적으로 함으로써 청정한 냉기류의 도심유입을 원활히 하여 도심의 대기오염을 저감하고자 하는 것도 목적으로 한다. 이 연구에서는, 수치실험을 통하여 전형적인 난후기일을 대상으로 대구지역의 국지순환풍이 지나는 바람의 길을 조사하였다. 그리고 이 바람에 의한 대기오염의 수송도 조사하였다. 수치실험에 사용한 모형은 RAMS(지역규모 대기모델)이다. 수치실험의 관심지역은 대구광역시 일대(약900$km^2$)이다. 수평규모는 약 30km이다. 수치실험은 일반풍이 약하고 쾌청한 일기조건을 갖는 늦봄의 기상조건 하에서 수행되었다. 수치실험의 결과 다음과 같은 3가지 결과를 얻었다: (1) 대구의 대표적 산지인 팔공산과 앞산에서 야간에 산정에서 복사냉각으로 생성된 국지풍이 지나는 길을 발견할 수 있었다. 그 바람은 대구의 동쪽 지역에서 중력류의 형태로 계곡을 따라서 흘러내렸다. (2) 평지에서는, 그 바람이 대구의 중심지를 지나 서쪽으로 흘러갔다. (3) 그 결과로, 대기오염물질은 야간에 국지풍에 의해 서쪽지역으로 수송되어졌다.

제트팬 운전에 의해 형성되는 터널내 유동에 대한 수치적 해석 (NUMERICAL ANALYSIS OF TUNNEL FLOW INDUCED BY JET FAN)

  • 김정엽
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.10-13
    • /
    • 2010
  • The flow field in road tunnel is influenced by some facts such as piston effect of vehicle's move, operation of ventilation facilities, natural wind and buoyancy effect of fire plume. Among those, jet fan is one of main ventilation facilities especially in longitudinal ventilation system of tunnel. In this study to analyze tunnel flow induced by operation of jet fan, numerical simulation has been carried out. The velocity distributions and streamlines in tunnel are examined to consider the three-dimensional characteristics of tunnel flow caused by jet fan.

  • PDF

자연환기 벤틸레이터 형태에 따른 환기효율 평가 (Evaluation of Ventilation Efficiency for Various Gravity Ventilators)

  • 하현철;김태형
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.543-551
    • /
    • 2002
  • Gravity ventilators allow the escape of the warm air and air contaminants due to both (either) buoyancy and (or) convection. As a natural ventilation strategy, various gravity ventilators can be installed on the roof. Ventilation efficiency could be affected by various parameters, such as, area of openings, wind velocity and incidence angle, temperature difference between inside and outside, and shape of ventilator. Especially, the shape of roof gravity ventilator might be one of influencing factors for the effective ventilation. The window type gravity ventilators are frequently installed instead of general (standard) gravity ventilator. However, the ventilation efficiencies of them were not proved yet. To compare the ventilation efficiency, general type ventilator and two window type ventilators were numerically tested. Mean age of air, temperature and CO concentration were predicted by using commercial CFD code, AIRPAK (Ver. 2.0) with various conditions. The predicted result showed that general type ventilator is more effective for natural ventilation than window type ventilators.

바람길숲의 유형별 분석 방안 - 대구광역시를 사례로 - (Analysis Schemes of Wind Ventilation Forest Types - A Case Study of Daegu Metropolitan City -)

  • 엄정희;오정학;손정민;김권;백준범;이채연
    • 한국지리정보학회지
    • /
    • 제22권4호
    • /
    • pp.12-23
    • /
    • 2019
  • 본 연구는 바람길숲의 유형별 분석 방안을 제시하는 것을 목적으로 하고 있으며, 이를 위해 도시 바람길숲을 바람 생성숲, 디딤·확산숲, 연결숲의 3가지 유형으로 분류하고, 각 유형별 특성에 따른 등급화 기준을 바탕으로 3등급으로 분류하였다. 바람 생성숲은 임상도의 밀도를 기준으로, 디딤·확산숲은 식생활력도를 기준으로, 연결숲은 바람통로 네트워크를 기준으로 각각 세 개의 등급으로 구분하였다. 대구광역시(883.56㎢)를 사례로 바람길숲을 분석한 결과, 바람 생성숲의 면적은 443.1㎢로 분류되었으며, 대구광역시의 북구 및 남쪽 일대에 분포하고 있었다. 그 중, 1등급 바람 생성숲이 가장 많은 면적(345.59㎢)을 차지하였고, 달성군에서 가장 높은 비율(54.44%)을 나타냈다. 반면 중구는 외곽의 산림지역과 단절되어 있기 때문에 생성숲이 존재하지 않았다. 디딤·확산숲의 면적은 32.4㎢로 대구광역시의 대표적인 도시공원 들이 포함되었으며, 수성구 및 달성군에서 상대적으로 많은 디딤·확산숲이 분포하였다. 하지만 디딤·확산숲은 대구시 전역에 분산적으로 분포되어 있고 식생지수가 높지 않았다. 연결숲 조성이 가능한 바람통로 네트워크는 대구광역시의 주요 하천, 도로 주변이 포함되었는데, 이러한 네트워크가 외곽 산림에서 도시공원으로 연결되어 있지 않았다. 따라서 대구광역시는 도시 외곽의 바람 생성숲과 도시 내부의 디딤·확산숲을 연결하는 연결숲 조성이 중요할 것으로 판단되었다. 본 연구의 결과는 체계적인 바람길숲 조성사업을 위한 기초자료로 활용될 수 있을 것이며, 국가 및 지자체 단위에서 바람길숲 분석에 대한 가이드라인 작성의 기초자료로 활용될 수 있을 것이다.

루버를 이용한 대형공장 내부 자 연환기유동 개선에 관한 연구 (Improvement for Natural Ventilation Flow inside a Large Factory Building Using Louver-t ype Ventilator)

  • 강종훈;이상준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.705-706
    • /
    • 2008
  • When heat generated inside a large factory building is not discharged due to a stagnant flow, the working environment of workers becomes worse and the cooling of high-temperature products such as hot-rolling coils is delayed. To investigate the natural ventilation inside a large factory building, experimental studies were carried out using wind-tunnel tests. The scale-down factory building models were placed in an atmospheric boundary layer (ABL) and the mean and fluctuating velocity fields were measured using a particle image velocimetry (PIV) technique. For the prototype factory model, the outdoor air is only entrained into the factory building through the one-third open windward wall, and stagnant flow is formed in the rear part of the target area. In order to improve the indoor ventilation environment of the factory building, three different louver-type ventilators were attached at the upper one-third open windward wall of the factory model. Among the three louver ventilators tested in this study, the ventilator model #3 with the outer louver (${\theta}_o$ = 90$^{\circ}$) and the inner louver (${\theta}_i$ = -70$^{\circ}$) was found to improve the natural ventilation inside the factory building model effectively. The flow rate of the entrained air was increased with aligning the outer louver blades with the oncoming wind and guiding the entrained air down to the ground surface with elongated inner louver blades.

  • PDF

Aerodynamic measurements of across-wind loads and responses of tapered super high-rise buildings

  • Deng, Ting;Yu, Xianfeng;Xie, Zhuangning
    • Wind and Structures
    • /
    • 제21권3호
    • /
    • pp.331-352
    • /
    • 2015
  • A series of wind tunnel tests were conducted on tapered super high-rise buildings with a square cross section by applying synchronous pressure measurement technology. The effects of global strategy of chamfered modification on aerodynamic loads and wind-induced responses were investigated. Moreover, local aerodynamic strategies of opening a ventilation slot in the corner of equipment and refuge floors were carried out. Results show that the global strategy of tapered elevation increased the vortex shedding frequency, but reduced vortex shedding energy, leading to reduction of across-wind aerodynamic loads and responses. Chamfered modification suppressed the across-wind vortex shedding effect on tapered buildings. Opening the ventilation slot further suppressed the strength of vortex shedding and reduced the residual energy related to vortex shedding in aerodynamic loads of chamfered buildings. Finally, the optimized locations of local aerodynamic strategies were suggested.