A Development of Coupled Simulation Tool to Evaluate Performance of Ventilation System (환기시스템의 성능평가를 위한 통합 시뮬레이션 Tool의 개발)

  • Cho Wang-Hee;Song Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.112-121
    • /
    • 2006
  • To evaluate the performance of ventilation system properly, the correlations among the ventilation rate, indoor air-quality and cooling/heating load should be analysed. In this study, simulation tool to analyze the performance of ventilation system was developed. The simulation tool is based on the TRNSYS and some modules to calculate concentration of pollutants with the operation of ventilation system and to decide the signal of ventilation system were newly developed in this study. And these modules coupled with building load and heating/cooling simulation modules. To verify the validity of developed simulation tool, comparison study between simulation and field study were accomplished. As results, the simulation tool developed in this study can be used to predict the performance of ventilation system with accuracy.

CFD analysis of ventilation efficiency around an elevated highway using visitation frequency and purging flow rate

  • Huang, Hong;Kato, Shinsuke;Ooka, Ryozo;Jiang, Taifeng
    • Wind and Structures
    • /
    • v.9 no.4
    • /
    • pp.297-313
    • /
    • 2006
  • The concentration of air pollution along roads is higher than the surrounding area because ventilation efficiency has decreased due to the high-density use of space along roads in recent years. In this study, ventilation efficiency around a heavily traffic road covered by an elevated highway and hemmed in along its side by buildings is evaluated using Visitation Frequency (VF, the frequency for pollutant to return to the objective domain) and Purging Flow Rate (PFR, the air flow rate for defining the local domain-averaged concentration). These are analyzed using Computational Fluid Dynamics (CFD) based on the standard $k-{\varepsilon}$ model. The VF and PFR characteristics of four objective domains are analyzed in terms of the changes in wind direction and arrangements of the fencing dividing up and down direction in the road center under the elevated highway. The resulting VFs are more than 1.0 for all cases, which means that pollutants return to the objective domain restricted by the elevated highway and side buildings. The influence of the arrangement of the buildings around the objective domain and the structure in the domain on the VF is substantial. In cases where there are no obstacles under the elevated highway, the local air exchange rate in the domain tends to be improved. Using these indices, the urban ventilation efficiencies between different urban areas can be compared easily.

Analysis of Field Measured Odor Emission Rate in Pig Houses (국내 돈사 악취 방출량 측정 결과 분석)

  • Decano-Valentin, Cristina;Lee, In-bok;Yeo, Uk-hyeon;Jeong, Duek-young;Lee, Sang-yeon;Park, Se-jun;Cho, Jeong-hwa;Lee, Min-hyeong;Jeong, Hyohyeog;Kim, Da-in;Kang, Sol-moe
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.6
    • /
    • pp.55-63
    • /
    • 2022
  • Odors emitted from pig houses have been a constant root of legal issues in pig farming. These gases are among the main causes of health and mental stresses to nearby communities, so policymakers and researchers continuously study to reduce the concentration of odorous gases from pig facilities. A continuous field experiment proved that the concentration of odor emissions inside the pig houses is highly dependent on ventilation rate, breeding details, and animal activities. However, the standard odor emission rate worldwide widely varies due to differences in pig house designs and ventilation requirements. Thus, this study aimed to measure the odor emission rates, considering the actual condition of selected Korean pig houses, through field measurement. The odor measurements were performed at three different pig production facilities without odor abatement technologies. The target experimental pig houses were buildings for weaning, growing, and fattening pigs. Results showed that the actual ventilation rate in target pig houses falls below the standard ventilation requirement of pigs, resulting in high odor concentrations inside the pig houses.

Effect of the Ventilation Method on the Growth and Quality of Melon (Cucumis melo L.) in Greenhouse of Tunnel Type (터널형 하우스에서 환기방법이 참외의 생육 및 품질에 미치는 영향)

  • 신용습;연일권;도한우;서동환;배수곤;최성국;최부술
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.187-193
    • /
    • 1996
  • This experiment was conducted to investigate the influence of temperature variation by the different ventilation methods on the growth and quality of oriental melon in greenhouse of tunnel type 1. The dropping effect in temperature by ventilation types was best at type 3 and those of type 2, type 1 were in order. 2. The temperature distribution in type 3 was uniformed as air- inflow and air- outflow by wind ventilation were easier than others. Whereas the temperature of type 1 having lateral ventilation hole and type 2 having the zenith ventilation tube and lateral ventilation hole was ascended, because small ventilation area of ventilation tube and hole could not make the gravity and wind ventilation successfully. 3. When compared with air amount of three types ventilated by the temperature difference of outside and inside of tunnel type house, that of type 3 was more than those of type 1 and type 2. 4. Type 3 was better than type 2 and type 1 in lear numbers, leaf area, fruit weight, flesh thickness, malformed fruit rate, and marketable fruit rate. 5. Marketable fruit rate of all treatment at each harvesting stages was rised, as goes to the latter periods.

  • PDF

Analysis on the installation criteria and ventilation effect for round roof windows in single-span plastic greenhouses (단동 플라스틱 온실의 천창 환기효과와 설치기준 분석)

  • Nam, Sang-Woon;Kim, Young-Shik;Ko, Gi-Hyuk;Sung, In-Mo
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.2
    • /
    • pp.271-277
    • /
    • 2012
  • Dimensions, operation conditions and improvement items for round roof windows were investigated in arch shape single-span plastic greenhouse with roof vents, and natural ventilation performance was analyzed based on the ventilation theory. Diameter of round roof windows was mostly 60 cm, and chimney height projected on roof was average 30 cm. Installation space was mostly 5 to 6 m but farmhouse of 10 m and over was 16.7% also. A round roof window which has 60 cm diameter was installed to 6 m space generally and 80 cm diameter was installed to 10 m space, but correct standards did not exist. There were a lot of opinions that ventilation effect of round roof windows is fairly good and user satisfaction is generally excellent. It is problem that there is few effects in summer and that vinyl around each vent tears well and rainwater leaks, and improvement hope item required development of automatic control system. In the wind speed of 0.3 m/s, it was estimated that natural ventilation rates were 0.69, 0.55, 0.50 and 0.48 volumes per minute in case of 2, 4, 6 and 8 m installation space for round roof windows, respectively. It was analyzed that the ratio of ventilation due to buoyancy out of total ventilation were 65.2, 41.9, 29.9 and 22.8% in case of 2, 4, 6 and 8m installation space, respectively. By the round roof windows installed at space of 6 m, ventilation rate was estimated to 0.5 volumes per minute, and we can expect the increase in ventilation rate of 30%. In order to meet the recommended ventilation rate for summer season, we have to install the round roof windows at space of 1 to 2 m. However, it is difficult to apply those installation space because of falling productivity due to lower light transmittance as well as rising costs. It is estimated that the installation space of 6m is appropriate for spring or fall season. Therefore it is necessary to encourage installing the roof windows in single-span plastic greenhouses.

A Study on the Ventilation Effects of the Shaft Development at a Local Limestone Mine (국내 석회석 광산 수갱 굴착에 의한 통기효과 분석 연구)

  • Lee, Changwoo;Nguyen, Van Duc;Kubuya, Kiro Rocky;Kim, Chang O
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.609-619
    • /
    • 2018
  • This study was carried out at a local limestone mine to analyze the ventilation efficiency of the shaft equipped with a main fan. The results show that its ventilation efficiency is clearly verified for the natural as well as the mechanical ventilation. The airflow rate of $11.7m^3/s$ was induced by the natural ventilation force and the maximum quantity is almost same as the airflow rate estimated by monitoring the average temperatures in the upcast and downcast air columns. Meanwhile, the airflow rate exhausted by the main fan through the shaft was $20.3{\sim}24.8m^3/s$; variation of the quantity was caused by the upward shift of the mine ventilation characteristic curve due to the frequent movement of the equipment. This indicates efforts are required to reduce the ventilation resistance and raise the quantity supplied by the main fan. The turbulent diffusion coefficients along the 1912 m long airway from the portal to the shaft bottom was estimated to be $15m^2/s$ and $18m^2/s$. Since these higher coefficients imply that contaminants will be dispersed at a faster velocity than the airflow, prompt exhaust method should be planned for the effective air quality control. The ventilation shaft and main fan are definitely what local limestone mines inevitably need for better working environment and sustainable development.

A Study on the Calculation of Ventilation Rate for the Improvement of Indoor Air Quality on the Barracks (군 내무실의 실내공기질 개선을 위한 환기량 산정에 관한 연구)

  • Choi Jeong-Min;Yu Jin-Sang;Jeong Young-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1043-1049
    • /
    • 2005
  • The purpose of this study is to improve indoor air quality of the barracks which have been changed from floor-type living barracks to bed-type living barracks since 2003. Therefore, the ventilation rates of newly constructed two type barracks were simulated with the various building materials including VOCs and HCHO components. And indoor air quality of two type living barracks was measured by the field experiments. With these steps, the measures for upgrading indoor air quality depending on building material types and ventilation rate are suggested.

The Effects of Micro-Environmental Factors on the House Dust Mite

  • Jo, Wan-Je;Sohn, Jang Yeul
    • Architectural research
    • /
    • v.9 no.2
    • /
    • pp.37-45
    • /
    • 2007
  • The proliferation of the House Dust Mite(HDM) is affected by temperature, humidity, ventilation, etc. Measuring temperature and humidity was performed at the very location where dust samplings take place and where they live in reality together with temperature and humidity of the ambient of the room. There has been discussion over the key environment factor of HDM survival; absolute humidity or relative humidity. It seems that relative humidity is the more important determinant for the mite's survival through the analysis of previous studies. Temperature, humidity, ventilation rate and Der P1 were measured in 4 flats in London. Mite allergen was detected in every house. Levels of Der P1 varied between <100ng/g and 22,778ng/g. Flats with high relative humidity(>50%) and poor ventilation(<0.5ach) showed higher levels of mite allergen than flats with lower humidity and adequate air change rate. Questionnaire survey was conducted and the result helped to confirm the findings from monitoring of environmental factors and the dust sampling.

Effective Control of Indoor Air Pollutant using VAV/BPFS (VAV/BPFS를 이용한 실내공기 오염물질의 효율적 제어)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.327-334
    • /
    • 1998
  • The oil crisis of the 1970s and the rise in oil prices motivated people to implement energy conservation strategies. Buildings were fitted with additional Insulation and reduced ventilation rates. The reduction of mechanical and natural ventilation rate led to Increases In Indoor pollutant concentrations which result- ed In Increased health risks from Indoor exposure to pollutants. The variable-air-volume /bypass fitration system/VAV/BPFS) is a variation of the conventional VAV systems, The VAV/BPFS is an electronically controlled system that provides costegectlve thermal comfort and acceptable indoor air quality Under controlled conditions In a chamber, a series experiments were performed to compare the ability of a VAV/BPFS to remove Indoor aerosol concentration and to reduce energy consumption no that ability of conventional VAV system. Results show that the VAV/BPFS Increases the effective ventilation rate and removes indoor air pollutant, and maintains acceptable indoor air Quality without sacrificing energy consumption.

  • PDF

A Study on Smoke Movement by Using Large Eddy Simulation I. Smoke Control Systems and Extraction Flowrate (대와류모사를 이용한 연기이동의 연구 I. 제연방식과 배기풍량)

  • 박외철
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.40-45
    • /
    • 2003
  • To evaluate the smoke control systems, the large eddy simulation turbulence model based Fire Dynamics Simulate was applied to a 2m $\times$ 2m $\times$ 2.4m room with an opening. The smoke removal rate was investigated for three different smoke control systems: ventilation, extraction and pressurization. When the opening was closed, the smoke removal rates of the smoke control systems were almost the same as expected. The pressurization system showed a lower smoke removal rate compared with the other two smoke control systems for the room with the opening, and hence the pressurization system might not be efficient for a place with large openings. It was shown that the lower extraction flowrate is, the longer time the ventilation system requires to remove smoke. From these results, the ventilation system is recommended for subway stations where several large openings exist.