A Study on the Airtightness Performance of New Han-ok Bedrooms (신한옥 침실 공간의 기밀성능 평가 연구)

  • Lee, Ju-Yeob;Jang, Hyeon-Chung;Lee, Tai-Gang;Song, Min-Jeong;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.79-89
    • /
    • 2013
  • The purpose of this study is to evaluate the airtightness performance of New Han-ok and to supply fundamental data for standards establishment. Air leakage testings were accomplished by means of blower door test in 26 bedrooms of 16 Han-oks located in Jeonnam happy villages. Followings are results. 1) Air change per hour at 50 Pa(ACH50) is located on 8.42~78.38. 2) No correlation between ACH50 and volumes, floor area, above grade surface area. 3) The more wood structural elements are exposed, attached spaces, wooden sliding and casement windows, the less airtightness performance. 4) An Airtightness with ACH50/20(NL, Normalized leakage) is located on 0.42~3.92 and building leakage class following F(4%), G(11%, sufficiently leaky, No need mechanical ventilation), H(4%, Need of cost-effective tightening), I(31%), J(50%) by a single-story house the normalized leakage of ASHRAE.

The Indoor Thermal and Air Environment of General Apartment Houses during Winter in Cheongju City (청주시 아파트 일반가정의 겨울철 실내열·공기환경 현장측정조사)

  • Cho, Jun Haeng;Choi, Yoon Jung
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.111-120
    • /
    • 2013
  • The purposes of this study were to investigate the actual state of the indoor thermal and air environment in general apartment houses during winter in Cheongju City, to analyze the related factors with the indoor thermal and air environment, and to make suggestions for the improvement. A series of visiting field investigation was conducted in twenty units between 28th December, 2010, and 11th March, 2011. The field investigations included the measurement of physical indoor environmental conditions, the observation of architectural characteristics and resident's behavior, and the on-site questionnaire survey of residents. The measured values of each units were compared to evaluation standard and were categorized to group by the difference between units. Factors related to the difference of the measured values between the groups were analyzed. The findings are summarized as followed. The indoor temperature of apartment houses during winter in Cheongju City was generally suitable. The relative humidity was slightly dry, while the $CO_2$ concentration was found to be excessively high. The factors related indoor environment were analysed as heating operation, ventilation, gas range use, and hanging out the wash to dry in indoors.

Development of an Integrated Controller to the Control Vertical Agitation Heater and Facilities (수직교반히터 및 시설물 제어를 위한 통합 제어기 개발)

  • Kim, Jin-Ha;Yoo, Seung-Hyeok;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.4
    • /
    • pp.753-758
    • /
    • 2020
  • In this paper, we intend to develop a control system that can apply the developed vertical stirring heater to the facility house and control the other facilities (circulating fan, ventilation fan, window using a switching motor, ceiling, and dehumidification). Through this, it is intended to increase the cultivation efficiency of crops and improve storage environment of crops held by non-heated storage or storage warehouses to increase the storage period and freshness. In addition, ICT monitoring technology is added to enable users to easily solve problems when there is a problem due to changes in the cultivation and storage environment with Real Time Control (RTC).

An Ecological Approach to Housing Experience of Korean Women in Malaysia (생태학적 접근으로 본 말레이시아 거주 한인 여성의 주거경험)

  • Hong, Hyung Ock
    • Human Ecology Research
    • /
    • v.53 no.4
    • /
    • pp.375-390
    • /
    • 2015
  • This study was designed to understand the residential experience of Korean women living in tropical country. For qualitative research, interviewees were selected by snowball sampling among Korean women living in Malaysia for over 20 years. The selection criteria for interviewees included husband's nationality, occupational experience, future living plan, frequency of travel to Korea. In-depth group and individual interviews were conducted from August 23 to October 7 2014. Subsequently (1) interviewees' general residential experiences in Malaysia were summarized, (2) interviewee's identity and lifestyle with housing pathways approach were clarified, (3) interviewees' residential experiences in 5 issues, reciprocity in residential area, intention of environmental change, meaning of housing and interaction, housing adaptation, and residential satisfaction/dissatisfaction were prescribed and interpreted. In conclusion, the reflection of interviewees' experiences in tropical country, suggested variations of housing structure type within a residential complex, air well and pocket by setback in building block for improving ventilation and noise prevention from neighbors, and ceiling fans in the house were suggested for the upcoming subtropical climate in Korea. Full option and minus options were also suggested for the presale market to reduce before occupancy remodeling needs. The research results implies valuable suggestions for a multicultural society, ecological housing and stronger communities.

Extended Epitympanotomy for Facial Nerve Decompression as a Minimally Invasive Approach

  • Chao, Janet Ren;Chang, Jiwon;Lee, Jun Ho
    • Journal of Audiology & Otology
    • /
    • v.23 no.4
    • /
    • pp.204-209
    • /
    • 2019
  • For a minimally invasive approach to access the facial nerve, we designed an extended epitympanotomy via a transmastoid approach that has proven useful in cases of traumatic facial nerve palsy and pre-cholesteatoma. To evaluate the surgical exposure through an extended epitympanotomy, six patients with traumatic facial nerve palsy were enrolled in this study. The same surgical technique was used in all patients. Patients were assessed and the degree of facial nerve paralysis was determined prior to surgery, 1-week post-operatively, and 6-months post-operatively using the House-Brackmann grading system. In all cases, surgical exposure was adequate. All patients with traumatic facial nerve palsy were male and the age range was 13 to 83 years. In all cases, the location of the facial nerve damage was limited to the area between the first and second genu. Symptoms of all the patients improved by 6 months post-operation (p=0.024). There were no complications in any of the patients. Extended epitympanotomy is useful for safe, rapid surgical exposure of the attic area, sparing the patient post-operative dimpling, skin incision complications, and lengthy exposure to anesthesia. We suggest that surgery for patients with facial nerve palsy secondary to trauma be performed using this described technique.

Extended Epitympanotomy for Facial Nerve Decompression as a Minimally Invasive Approach

  • Chao, Janet Ren;Chang, Jiwon;Lee, Jun Ho
    • Korean Journal of Audiology
    • /
    • v.23 no.4
    • /
    • pp.204-209
    • /
    • 2019
  • For a minimally invasive approach to access the facial nerve, we designed an extended epitympanotomy via a transmastoid approach that has proven useful in cases of traumatic facial nerve palsy and pre-cholesteatoma. To evaluate the surgical exposure through an extended epitympanotomy, six patients with traumatic facial nerve palsy were enrolled in this study. The same surgical technique was used in all patients. Patients were assessed and the degree of facial nerve paralysis was determined prior to surgery, 1-week post-operatively, and 6-months post-operatively using the House-Brackmann grading system. In all cases, surgical exposure was adequate. All patients with traumatic facial nerve palsy were male and the age range was 13 to 83 years. In all cases, the location of the facial nerve damage was limited to the area between the first and second genu. Symptoms of all the patients improved by 6 months post-operation (p=0.024). There were no complications in any of the patients. Extended epitympanotomy is useful for safe, rapid surgical exposure of the attic area, sparing the patient post-operative dimpling, skin incision complications, and lengthy exposure to anesthesia. We suggest that surgery for patients with facial nerve palsy secondary to trauma be performed using this described technique.

Estimation of THI Index to Evaluate Thermal Stress of Animal-occupied Zone in a Broiler House Using BES Method (BES 기법을 이용한 육계사 내부 고온 스트레스 평가를 위한 THI 지수 모의)

  • Ha, Taehwan;Kwon, Kyeong-seok;Hong, Se-Woon;Choi, Hee-chul;Lee, Jun-yeob;Lee, Dong-hyun;Woo, Saemee;Yang, Ka-young;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sangyeon;Lee, In-bok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.2
    • /
    • pp.75-84
    • /
    • 2018
  • Thermal stress of livestock has been issued due to recent climate change trends and this causes reproductive disorders, decreased feed consumption, immunosuppression, and increased mortality of animals. Concept of THI has been widely used to quantitatively evaluate the degree of thermal stress for animals, however use of this concept is restricted for animals living in the enclosed facilities such as mechanically ventilated broiler houses. In this study, time-based internal energy flow and variation trends of temperature and humidity were analyzed based on BES technique. Local weather data, insulation characteristics of building materials, heat and moisture generation rate from broilers according to age, algorithm of ventilation operation were adopted for boundary condition of the model to accurately compute THI values inside the mechanically ventilated broiler house. From the BES computation, excess frequency of THI threshold in Jeju city was highest on the assumption that air conditioning equipments were not installed. When general raising density ($39kg\;m^{-2}$) was adopted, total 2,191 hours were exceeded. Excess hours of THI threshold were strongly related to the cumulative air temperature ($R^2=0.87$).

Evaluation of pig behavior changes related to temperature, relative humidity, volatile organic compounds, and illuminance

  • Kim, Yong Ju;Song, Min Ho;Lee, Sang In;Lee, Ji Hwan;Oh, Han Jin;An, Jae Woo;Chang, Se Yeon;Go, Young Bin;Park, Beom Jun;Jo, Min Seok;Lee, Chang Gyu;Kim, Hyeun Bum;Cho, Jin Ho
    • Journal of Animal Science and Technology
    • /
    • v.63 no.4
    • /
    • pp.790-798
    • /
    • 2021
  • The objective of this study was evaluation of pig behavior changes related to temperature, relative humidity, volatile organic compounds (VOCs), and illuminance. A total of 24 growing pigs ([Yorkshire × Landrace] × Duroc) were used in the experiment. A sensor was installed at a height of 0.5 m in the center of the pig house. In experiment 1, temperature was changed every four days to 18℃ (T1), 22℃ (T2), 26℃ (T3), and then 30℃ (T4). In experiment 2, relative humidity was adjusted to 45% (low humidity [LH]), 60% (middle humidity [MH]), and then 75% (high humidity [HH]) for four days. In experiment 3, after cleaning the pig house just before experiment, only minimal ventilation was provided. VOCs and pig behaviors were observed for 7 days without cleaning the pig house. In experiment 4, three light bulbs of 40 W (470 lumens / 45 lx; low illuminance [LI]), 75 W (1,055 lumens / 103 lx; middle illuminance [MI]), and 100 W (1,521 lumens / 146 lx; high illuminance [HI]) were used for four days each. Pig behavior analysis was performed for following criteria : Feed intake, Standing, Lying, Sitting, Drink water, Rooting, Posture transition (lying-standing), Posture transition (standing-lying), Wallowing, and Biting. In experiment 1, feed intake time was lower (p < 0.05) for the T3 than other treatment groups. Standing time was highest (p < 0.05) for the T1 and lowest (p < 0.05) for the T3. Lying time was shorter (p < 0.05) in T1 and T2 compared to T3 and T4. Drinking frequency was higher (p < 0.05) for the T4 than other treatment groups. In experiment 2, the frequency of rooting and wallowing increased (p < 0.05) with increasing humidity. LH showed the lowest (p < 0.05) rooting frequency and HH showed the highest (p < 0.05) rooting frequency. In experiment 3, VOCs concentration did not (p > 0.05) change pig behavior. In experiment 4, lying time was the longest (p < 0.05) at LI and shortest (p < 0.05) at HI. Therefore, pig behavior is heavily influenced by the environment, especially temperature and humidity. However, correlation between pig behavior to VOCs and illuminance seems to be needed more research.

Survey on Chicken Housing Types in Different Farm Scale and Region (양계농가의 사육규모별, 지역별 계사 시설현황 분석)

  • Choi, H.C.;Kham, D.H.;Na, J.C.;Bang, H.T.;Yu, D.J.;Suh, O.S.;Song, J.I.;Jeon, B.S.;Jeon, J.H.;Yoo, Y.H.;Lee, S.C.;Kim, J.S.;Lee, D.H.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.3
    • /
    • pp.189-198
    • /
    • 2009
  • This survey was conducted to investigate the situation of housing type in poultry farms in Korea. The number surveyed among the farm size over 30,000 heads was 1,965 farms. Poultry housing types of windowless, open sided, vinyl house type were 19.0, 47.7, 19.8%, respectively. Waterers of nipple, bell, and 8 feet trough used in smaller than 50,000 heads of poultry farm were 40.6, 11.3 and 42.8%, respectively. But the bigger farm in the farm size of over 100,000 heads used more nipple waterer. Feeders of disk, hopper and chain used in poultry farm were 54.5, 16.3, 15.8%, respectively. Manure collecting system of scraper and belt was 29.4, 71.5 %, respectively. Ventilation systems of natural ventilation, natural + mechanical ventilation, mechanical ventilation were 40.5, 39.8, 20.7%, respectively.

  • PDF

The Effects of Winch-curtain Ventilation on the Indoor Environment of a Fattening Swine House (윈치커튼 환기가 비육돈사의 실내 환경에 미치는 영향)

  • Kim, Hyeon-Tae;Song, Jun-Ik;Choi, Hong-Lim
    • Journal of Animal Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • The study was conducted to investigate the effects of climate on indoor environment of a swine house with natural. This study was tested in the beef swine stall at Young-in, Kyung-ki do. The test was experimented for the effect of interior environment by the outdoor environment and the interior-pan. The results are as follows. 1. In test 1 ($T_{out}$ : $25.7^{\circ}C$, without fan), an indoor air flow pattern was showed that entered from sidewall winch-curtain to went out of a indoor by the ridge winch-curtain. And the velocity of a section of the center was measured two times as large as the velocity of the floor. It is the acceleration of the velocity by thermal buoyancy. And, the entered air was rapidly dissipated by flow energy. So that in the swain livestock with sidewall winch-curtain is effected by thermal buoyancy. And the air temperature of the indoor was distributed more higher as compared with the outdoor temperature. This result is caused by the sensible heat from swine and the ventilation is restricted. 2. In test 2 (($T_{out}$ : $25.7^{\circ}C$, with fan), the velocity of a section of the center was measured more higher as compared with the test 1. And the variance of air velocity was distributed higher as compared with the test 1. This result is showed dead region of air flow with a fan operation. And, the variance of gas density was distributed lower as compared with the test 1.