• Title/Summary/Keyword: ventilation house

Search Result 303, Processing Time 0.024 seconds

A Comparative Study on the Housing Viewpoint between Korean and Chinese University Students (한.중 대학생의 주거관에 대한 비교 연구)

  • An, Ok-Hee;Jo, Oung-Mi;Hao, Jia
    • Journal of the Korean housing association
    • /
    • v.20 no.4
    • /
    • pp.121-129
    • /
    • 2009
  • Today, we are living while interchanging with various countries in multilateral measures and residential culture have been changed while interchanging in the same manner. In order to become an internationally recognized residential environment designer in this environment, we must understand the housing viewpoint of residents in that country first. Therefore, this study is intended to obtain the useful materials for residential environment design of Korea and China by comparing the housing viewpoint between Chinese students studying in Korea and Korean students. A survey using questionnaire was conducted on 205 Korean students and 193 Chinese students (Chinese race) from Y University on a random sampling basis. The result of survey is as follows. First, as both Korean and Chinese university students have a similar tendency on previous house type, current house type, and desired house type, it can be understood that they are similar each other in the experience and preference of house type. Second, Korean and Chinese university students consider and as the most important functions of residence, but Chinese university students consider more functions of residence than Korean students. And, both Korean and Chinese students consider a living room as the most important space among housing spaces, but Chinese consider a private room more importantly than Korean. Third, Chinese university students have stronger desire to possess houses, and desire to purchase houses with larger and more rooms at earlier time than Korean university students. Fourth, when selecting the house, Chinese university students give a higher consideration in terms such as , , , , and than Korean university students. Fifth, satisfaction level of Korean students on current houses was average as a whole, and most Chinese students were generally satisfied with their houses. Sixth, as both of Korean and Chinese university students have higher level of consideration in the items such as safety>, , , , , , , , , , and compared to the level of satisfaction, thoughtful consideration should be given to those items in housing planning.

Measurement of Dust Concentration in a Naturally Ventilated Broiler House according to Season and Worker's Access (윈치커튼식 계사의 시기 및 작업자 출입에 따른 분진 발생 농도 측정 연구)

  • Jo, Ye-seul;Kwon, Kyeong-seok;Lee, In-bok;Ha, Tae-hwan;Park, Se-jun;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sang-yeon;Lee, Seung-no
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.35-46
    • /
    • 2015
  • Improvement in domestic poultry production has a positive effect on the export competitiveness of the poultry industry. However, overproduction and enlargement of facilities to assure a supply increase a stocking density which make a poor environment in the broiler house. In particular, an intensive rearing environment is vulnerable to dust control that causes respiratory diseases, such as asthma, bronchitis, etc., to farmers and broilers. However, monitoring data and research for environment control are not adequate, and there are no air quality regulations in broiler houses in Korea. In this study, TSP, PM10, inhalable dust and respirable dust concentration were monitored according to season, age of broiler and broiler's activities. Air quality assessment was also performed in accordance with the threshold limit value by Donham et al. (2000). The TSP concentrations were 77.5 %, 219.7 % higher and PM10 concentrations were 121.2 %, 303.8 % higher when change of season and winter respectively than summer. There were significantly different concentrations according to season and age of broiler. Inhalable and respirable dust concentration were also clearly different according to the season and age of broiler. A high dust concentration was observed, specifically exceeding the threshold limit by 119 % in the winter. In the case of the broiler's motion was activity according to worker's access into the broiler house, concentration level was 769.6 % higher than broiler's motion was stable and exceeded the threshold limit. These results suggest that the worker should put on protective equipment to protect there's respiratory health in the broiler house.

Fog Nozzle-Greenhouse Cooling System Analysis (포그노즐을 이용한 온실냉방시스템 분석)

  • 김영중;유영선;윤진하;오권영;김승희
    • Journal of Bio-Environment Control
    • /
    • v.6 no.1
    • /
    • pp.48-54
    • /
    • 1997
  • Among the various vegetables eggplant and gourd family can stand against high temperature environmental condition, about 35$^{\circ}C$. However, most of greenhouse farmers are giving up crop cultivation during hot summer season due to extreme temperature, 4$0^{\circ}C$ or above, condition of greenhouse interior. To improve this inferior crop growth condition, for nozzle system was installed in the pet greenhouse and the effect of fog system was investigated in order to determine fog water amount and the required fog nozzle numbers according to house volumes. MEE fog nozzle was selected for this Investigation which can produce water particle size of 27${\mu}{\textrm}{m}$ with water amount of 100$m\ell$ at pumping pressure of 70kg/$\textrm{cm}^2$. House cooling test was conducted in the pet greenhouse with one minute fogging and one minute air ventilation without stopping. It maintained 32$^{\circ}C$ at the house interior when the atmosphere and the house temperature were 35 and 4$0^{\circ}C$, respectively. And, an experimental equation was developed through calculating the changes of relative humidity and temperature with psychrometric equation which revealed the moisture transfer pattern between the house air and fog system. It showed that the required water fogging amounts to reduce 1$0^{\circ}C$, 40 to 3$0^{\circ}C$, needs 80.7$\ell$ for 1-2W(8,350㎥) and 99.9$\ell$ for 3-2G-3S(10,330㎥) type greenhouse with particle size of 27${\mu}{\textrm}{m}$.

  • PDF

Effects of Various Ventilation Systems on the Carbon Dioxide Concentration and Fruiting Body Formation of King Oyster Mushroom (Pleurotus eryngii) Grown in Culture Bottles (새송이버섯 병재배에서 환기방법이 이산화탄소 농도 및 자실체형성에 미치는 영향)

  • Lee, Hyun-Uk;Ahn, Mi-Jeong;Lee, Shin-Woo;Lee, Cheol-Ho
    • Journal of Life Science
    • /
    • v.17 no.1 s.81
    • /
    • pp.82-90
    • /
    • 2007
  • In an attempt to establish the appropriate ventilation device for the bottle culture of king oyster mushroom (Pleurotus eryngii), we investigated carbon dioxide concentration and fruiting body formation according to the various ventilation systems within the mushroom house. In addition to, the efficiency of air circulation and growth rate as well as the appearance of physiologically abnormal phenotypes during their growth stage were also evaluated. four different ventilation devices, parallel-pressure type, positive-pressure type, negative-pressure type, and positive- and negative-pressure type were applied in this study. The positive-and negative-pressure type showed the highest efficiency of air circulation as $CO_2$ concentration was 800 ppm and the level of air current was relatively low compared to the other types (the $CO_2$ concentration of parallel-pressure type was 1,400 ppm). Moreover, the stipe length, the cap diameter, yield, and general quality grown in positive- and negative type ventilation device were also better than in the other three devices though it took slightly longer period for harvesting (18.4 days) than the others (17.6, 17.9 and 18.3 days). The appearance of physiologically abnormal phenotypes such as fruiting body lump, soft rot, and brown rot were significantly decreased in positive-and negative type compared to other types, while the appearance rates were not much different for other symptoms of bacterial ooze, stipe limb and stipe bumpy. In summary, we propose that the optimal ventilation system for the bottle culture of king oyster mushroom is positive- and negative type, and this device is expected to increase the total quality as well as yield all year around.

Mannheimiosis case in Hanwoo caused by heat stress (한우에서 고온스트레스에 의한 Mannheimiosis 발생 증례)

  • Lee, Jeong-Won;Shon, Ku-Rye;Jeong, Han-Sol;Ko, Won-Seok;Lim, Chae-Woong;Kim, Bum-Seok
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.3
    • /
    • pp.195-198
    • /
    • 2015
  • Mannheimia haemolytica is an opportunistic bacterium that is widely recognized among the bovine respiratory disease (BRD) complex in cattle. Five Hanwoo with a history of fever, anorexia and dyspnea were died within 2 days in a the middle of summer. Four cattle were pregnant. The cattle house were located in mountainous area but the window for air ventilation was open only one side. In addition, the fecal material for fermentation was located indoor. Air ceiling fan did not work. The indoor temperature was $40^{\circ}C$. After working on air fan, the indoor temperature was still $36^{\circ}C$. On necropsy, there was fibrinous pleuritis with a rich yellowish pleural fluids in the thorax. The cross-section of the lung showed lobar fibrinonecrotic pneumonia with expanded interlobular septa by edema and fibrin. Microscopically, parenchymal necrosis with dense layer of inflammatory cells were observed surrounding interlobular septum. Fibrin and inflammatory cells were filled in the alveoli. Bacteriological cultures of pulmonary tissue showed growth of M. haemolytica. This pneumonia case in Hanwoo suggests that environmental stressors such as high temperature, insufficient air ventilation, and pregnancy be the cause of mannheimoisis. Control of environmental stressor, such as temperature indoor is necessary to prevent BRD caused by M. haemolytica.

Development of Straightforward Method of Estimating LMA and LMR using Computational Fluid Dynamics Technology (전산유체역학 기법을 이용한 공기연령 산정 방법의 개발)

  • Park, Se-Jun;Lee, In-Bok;Hong, Se-Woon;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Yun, Nam-Gyu;Kim, Hyung-Gewon;Kwon, Sun-Hong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.6
    • /
    • pp.135-144
    • /
    • 2013
  • Ventilation efficiency has an important role in agricultural facilities such as greenhouse and livestock house to keep internally optimum environmental condition. Age-of-air concept allows to assess the ventilation efficiency of an agricultural facility according to estimating the ability of fresh air supply and contaminants emission using LMA and LMR. Most of these methods use a tracer gas method which has some limitations in experiment like dealing unstable and invisible gas. Therefore, the aim of this study was to develop a straightforward method to calculate age-of-air values with CFD simulation which has the advantage of saving computational time and resources and these method can solve the limitations in experiment using tracer gas method. The main idea of LMA computation is to solve the passive scalar transport equation with the assumption that the production of the time scalar throughout the room is uniform. In case of LMR calculation, the transport of the time scalar was reversed compulsively using UDF. The methodology to validate the results of this study was established by comparing with preceding research that had performed a computing LMA and LMR value by laboratory experiments and CFD simulations using tracer gas. As a result, the error was presented similarly level of results of preceding research. Some big errors could be caused by stagnated area and incongruity turbulence model. while the computational time was reduced to almost one fourth of that by preceding research.

Study on Fault Detection System used the Classified Rule-based of HVAC (분류형 규칙기반을 이용한 HVAC 시스템의 고장검출에 관한 연구)

  • Yoo, Seung-Sun;Youk, Sang-Jo;Cho, Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.11B
    • /
    • pp.655-662
    • /
    • 2007
  • Monitoring systems used at present to operate HVAC(Heating, Ventilation and Air Conditioning) optimally do not have a function that enables to detect faults properly when there are faults of such as operating plants or performance falling, so they are unable to manage faults rapidly and operate optimally. In this paper, we have developed a classified rule-based fault detection system which can be inclusively used in HVAC system of a building by installation of sensor which is composed of HVAC system and required low costs compare to the model based fault detection system which can be used only in a special building or system. In order to experiment this algorithm, it was applied to HVAC system which is installed inside EC(Environment Chamber), verified its own practical effect, and confirmed its own applicability to the related field in the future.

Analysis of the Disease Spread in a Livestock Building Using Tracer Gas Experiment (추적가스 실험을 통한 축사 내 질병 확산 분석)

  • Song, Sang-Hyeon;Lee, In-Bok;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Bitog, Jessie P.;Hong, Se-Woon;Seo, Il-Hwan;Moon, Oun-Kyeong;Kim, Yeon-Joo;Choi, Eun-Jin
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.3
    • /
    • pp.37-45
    • /
    • 2012
  • Recently, the livestock industry in Korea was heavily affected by the outbreak of official livestock diseases such as foot and mouse disease, high pathogenic avian influenza, swine influenza, and so on. It has been established that these diseases are being spread through direct contact, droplet and airborne transmission. Among these transmissions, airborne transmission is very complex in conducting field investigation due to the invisibility of the pathogens and unstable weather conditions. In this study, the airborne transmission was thoroughly investigated inside a pig house by conducting tracer gas ($CO_2$) experiment because experiment with real pathogen is limited and dangerous. This is possible as it can be assumed that the flow is similar pattern very fine particles and gas. In the experiment, the ventilation structure as well as the location of gas emission were varied. The $CO_2$ detection sensors were installed at 0.5 and 1.3 m height from the floor surface. The tracer gas level was measured every second. Results revealed that the direction of spread can be determined by the response time. Response time refers to the time to reach 150 ppm from the gas emission source at each measuring points. The location of the main flow as well as the gas emission was also found to be very important factor causing the spread.

A Study on The Performance of Ventilation and Maintaining Thermal Environment for a Combined Type Diffuser (급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.232-241
    • /
    • 2016
  • Installing a ventilator for an apartment house composed of over 100 dwelling units was mandated in 2006 to improve indoor air quality. In the case of mechanical ventilators, the air change rate is kept stable, however 68% of dwellers do not operate their ventilator because of an increased electrical bill and noise. In the case of natural ventilators, the former problems are settled, but there are concerns about cold draught and an increase of heating/cooling cost. Authors are developing a heat recovery type natural ventilator which is a natural ventilator equipped with total heat recovery element, and it is expected that those problems of mechanical ventilator and natural ventilator are resolved by this. The combined type diffuser of this study is an under developed fit to the heat recovery type natural ventilator above. There are no standards to evaluate the performance for this type of diffuser. Due to this issue this study investigated the performance of the ventilation and maintained a thermal environment for the combined type diffuser by comparing it with existing diffusers. The results revealed that the performances of the combined type of diffusers showed different features from the existing ones, and was estimated to be high enough in the performances above.

Evaluation of Livestock Odor Reduction Efficiency for Odor Reduction Systems in Domestic Pig Farms (돈사용 스크러버 및 바이오커튼의 축산악취 저감효과 분석)

  • Lee, Minhyung;Yeo, Uk-hyeon;Lee, In-Bok;Jeong, Duek-young;Lee, Sang-yeon;Kim, Jun-gyu;Decano-Valentin, Cristina;Choi, Young-bae;Kang, Sol-moe
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.6
    • /
    • pp.77-86
    • /
    • 2022
  • Various odor reduction systems are being operated at pig houses to improve livestock odor issues. However, the quantitative evaluation of odor reduction efficiency is not sufficiently conducted. The analysis of factors that affect the reduction efficiency also has not been sufficiently conducted. Therefore, in this study, the reduction efficiency of representative odor reduction facilities (bio-curtain, scrubber) operated by domestic pig houses was evaluated. The odor reduction efficiency was evaluated by sampling the air before and after the odor reduction facility in 6 pig houses. Livestock odors were evaluated for complex odors, ammonia, hydrogen sulfide, and VOC. To find factors for reduction efficiency, temperature, humidity, pH of washing resolution, type of washing water, and ventilation rate was measured. As a result, it was found that the scrubber system had the highest reduction efficiency. The reduction efficiency was found to be affected by the scrubber's washing resolution, filler, operating conditions, and size. Bio-curtains may have problems such as deterioration of fan performance due to ventilation fan load, groundwater pollution, and excessive use of groundwater.