• 제목/요약/키워드: ventilating hole

검색결과 4건 처리시간 0.021초

통기성 상자 구조물에 대한 유한요소 해석 (Finite Element Analysis of a Ventilating Box Structure)

  • 박종민;권순구
    • Journal of Biosystems Engineering
    • /
    • 제27권6호
    • /
    • pp.557-564
    • /
    • 2002
  • Corrugated board is an efficient low-cost structure material fur the boxes that are widely used for transporting, storing and distributing goods. Corrugated board is also considered as an orthotropic because the principal material directions are the same as in paperboard. The purpose of this study was to elucidate the principal design parameters of ventilating box through the FEA on the various types of ventilating hole. From the viewpoint of the stress distribution and stress level, the optimum pattern and location of the ventilating hole were vertically oblong, and symmetry position with a short distance to the right and left from the center of front and rear panel. And, the optimum location and pattern of hand hole were a short distance to the top from the center of both side panels, and modified shape to increase the radius of curvature of both side in horizontal oblong. In general, the optimum pattern and location of both the ventilating hole and hand hole based on the FEM analysis were well verified by experimental investigation. It is suggested that decrease in compressive strength of the box could be minimized in the same ventilating hole area under the condition of the length of major axis of ventilating hole is less than 1/4 of box length, the ratio of minor axis/major axis is 113.5∼l/2.5, and number of the ventilating holes is even and symmetrical.

통기성 상자 구조물의 강도적 최적화 연구(I)-실증 분석 (Strength Optimization of Ventilating Container(I)-Experimental Analysis)

  • 박종민
    • 한국포장학회지
    • /
    • 제7권2호
    • /
    • pp.19-24
    • /
    • 2001
  • 현재 국내에는 통기성 상자의 설계에 관한 기준이 마련되어 있지않아, 통기공으로 인한 상자 압축강도 저하와 통기성 면에서도 좋지 않은 형편이다. 선진 외국과는 물류 및 포장환경이 다르고, 방법에 있어서도 큰 차이가 있기 때문에 외국의 사례를 국내의 포장설계에 적용하는 데는 한계가 있다. 따라서 본 연구는 현재 국내에서 유통되는 통기성 상자에 대한 실태분석과 온 습도 변화에 따른 압축강도 저하와 통기성을 분석하므로써, 통기성 상자의 최적설계를 위한 설계 기준을 마련하고자 수행되었다. 현행 유통되는 통기성 상자의 통기공의 면적 비율은 $1.41{\sim}2.65%$ 였으며, 통기공의 형태, 크기 및 위치가 매우 다양하여, 이로 인한 상자 압축강도 저하율은 $8.5{\sim}20.2%$의 범위에 있었다. 대체로 통기공의 면적비율 보다는 통기공의 형태와 위치가 상자의 압축강도 저하에 미치는 더 중요한 요인으로 분석되었다. 통기공의 면적비율이 클 수록 온도와 상대습도의 평형도달시간은 짧았으며, 온도가 상대습도에 비하여 더 빨리 형평상태에 도달하였으며, 또한 통기공의 면적 비율이 같은 경우, 통기공의 형태에 따른 온도 및 상대습도의 평형도달 시간과 평형도달 온 습도에 있어서는 큰 차이가 없었다.

  • PDF

통기성 상자 구조물의 강도적 최적화 연구(II)-유한요소해석 (Strength Optimization of Ventilating Container(II)-Finite Element Analysis)

  • 박종민
    • 한국포장학회지
    • /
    • 제7권2호
    • /
    • pp.25-30
    • /
    • 2001
  • Corrugated board is composed of cellulose fibers which are arranged with the same direction as the board manufactured. The direction is classified with machine direction (MD) and cross-machine direction (CD). Therefore, corrugated board is orthotropic material that has totally different strength properties at each direction and especially, at machine direction, the mechanical properties of fiberboard is superior. The compression strength of the corrugated fiberboard boxes is very important information to the manufacturers and the end users. This study was carried out to design the optimum pattern, size, and location of ventilating hole for ventilating container through the finite element analysis. The optimum pattern and location of ventilating and hand hole were vertical oblong, a short distance to the right and left from the center of panel, and center or a short distance to the top of both sides, respectively. We identified the effect on both stress dispersion and stress level from the analysis of redisigned hand hole.

  • PDF

양파 간이저장시 통풍조건 및 통풍구 재료의 크기가 저장에 미치는 영향 (Effects of Ventilation Condition and Ventilating Hole Sizes to Improve Quality Onion(Allium cepu. L) under Room Temperature)

  • 이찬중;김희대;정은호;김우일;서전규
    • 한국식품저장유통학회지
    • /
    • 제8권4호
    • /
    • pp.356-361
    • /
    • 2001
  • 양파 간이저장시 노지야적에 의해 발생하는 부패를 감소시켜 망과의 안전저장을 위하여 조립식 간이하우스를 이용하여 통풍조건 및 통풍구 재료의 크기에 따른 저장성을 조사한 결과는 다음과 같다. 평균온도는 노지야적에 비해 강제통풍에서 0.3~3.6$^{\circ}C$높았고, 무통풍에 비해서는 1.4~8.2$^{\circ}C$가 낮았다. 그러나 처리간 유의차는 없었다. 상대습도는 통풍처리구에서 무통풍 및 노지야적에 비해 약간 높았다. 구중감소율은 노지야적에서는 2.5%, 무통풍에서는 2.9%, 자연통풍 2단에서는 3%, 강제통풍 2단에서는 4.3%였다. 8월 하순까지의 부패율은 자연통풍 2단 27.7%, 강제통풍 2단 25.4%,인데 비해 무통풍 34.6%, 노지야적 37.8%로 통풍처리구에서 부패가 적었다. 통붕구 재료의 크기가 클수록 평균기온은 조금 낮았고, 상대습도는 7월에 조금 높은 경향을 보이다가 8월 이후에는 차이가 거의 없었다. 통풍 파이프 표면의 풍속은 통풍구의 크기가 작을수록 강했으며, 부위별로는 중간부위가 양끝쪽보다 낮았다. 부패율은 75mm통풍구 17.9%, 100mm통풍구 15.3%, 125mm통풍구 14.1%로 통풍구 크기가 클수록 부패는 적었다.

  • PDF