• Title/Summary/Keyword: vent width

Search Result 19, Processing Time 0.029 seconds

Optimal design of escape vent for the dome type coonstrip shrimp (Pandalus hypsinotus) pot (반구형 도화새우통발에 있어서 적정 탈출구의 설계)

  • Kim, Seong-Hun;Lee, Ju-Hee;Kim, Hyung-Seok;Park, Seong-Wook
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.2
    • /
    • pp.115-125
    • /
    • 2010
  • In order to design the optimal escape vent for the coon strip shrimp pot, the tank experiments were conducted with the model pot of five different slit height and slit width, respectively. The optimal height and width of escape vent were determined to 20mm and 40mm by tank experiments, respectively. These were determined by the 50% selection carapace length which was denoted to 25mm in selectivity curve. The escape experiments were conducted to determine a number of escape vent with the original shrimp pot to be set the designed escape vent from 2 vents to 10 vents increasing at intervals of 2 vents in tank. The optimal number of escape vents denoted 8 vents. Therefore, to apply the escape vent in commercial shrimp pot will be efficient to reduce small size shrimps to catch.

A Study on the Explosion Relief Venting in the Gas Explosion (실내 가스 폭발시 폭발압력 방출에 관한 연구)

  • Oh, Kyu-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.71-77
    • /
    • 2005
  • This study aims to find the safe vent area to prevent a destruction of building by gas explosion in a building. Explosion vessel which used in this experiment is 1/5 scale down model of simple livingroom and its dimension is 100cm in length 60cm in width and 45cm in height. Liquified petroleum gas(LPG) was injected to the vessel to the concentration of 4.5vol%, and injection rate were varied in 1L/min or 4L/min. Gas mixture was ignited by the 10kV electric spark. For analysis the characteristics of vented explosion pressure according to the vent size and vent shape, its size and shape were varied. From the experiment, it was found that explosion pressure in the vented explosion :in affected by the gas injection rate, vent area and vent shape. And the vent area to volume ratio(S/V) to prevent the building destruction by explosion pressure, it is recommended that the design of vent area happened by the explosion should be above 1/500cm in S/V. And if the vent area has complicate structure in same area, vented explosion pressure will be higher than a single vent, and possibility of building destruction will increase. Therefore to effectively vent the explosion pressure for protect a building and residents from the gas explosion hazards, the same vent area should have a singular and constant shape in the cross-sectional area of the vessel.

Evaluation on Performance of Chill Vent in High Pressure Die Casting by Using a Commercial Software (상용 열유동 해석 소프트웨어를 이용한 다이캐스팅 칠벤트의 성능평가)

  • Kang, Bok-Hyun;Kim, Tae-Bum;Kim, Ki-Young
    • Journal of Korea Foundry Society
    • /
    • v.32 no.3
    • /
    • pp.133-137
    • /
    • 2012
  • Chill vent has a zigzag venting path which allows residual air or gases to exhaust out very quickly from the die cavity. However molten metal sometimes comes out through the gas venting surfaces causing flash. Effect of designing factors of chill vent and processing variables in high pressure die casting on the performance of chill vent was investigated through a series of calculations by using a commercial code. The most influential factor was the thickness of chill vent, followed by inlet velocity, vent width and die temperature.

An Experimental Study of Smoke Movement in Tunnel Fires with a Vertical Shaft (수직갱이 설치된 터널내 화재시 연기거동에 관한 실험적 연구)

  • 이성룡;유홍선;김충익
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.135-141
    • /
    • 2004
  • The present paper concerns a smoke movement in a tunnel fire with a vertical shaft. The model tunnel measured 13.4m long, 0.4m wide and 0.4m high. The cross section is 1: 20 of a full scale tunnel. Ethanol was used as a fuel. The fire size in model tests varied from 1.35 kW to 13.37 kW, which corresponds to full scale fires of 2.41 to 23.91 MW. Smoke front velocity and temperatrue were decreased due to the vertical shaft install. Temperature was reduced maximum about 2$0^{\circ}C$ at ceiling and about 23$^{\circ}C$ at vertical position. CO concentration was reduced as the vent width widened. When vent width was more than 15 cm, CO concentration was not reached 100 ppm. Descent degree of the smoke layer was confirmed through the visualization.

Investigation on flutter mechanism of long-span bridges with 2d-3DOF method

  • Yang, Yongxin;Ge, Yaojun;Xiang, Haifan
    • Wind and Structures
    • /
    • v.10 no.5
    • /
    • pp.421-435
    • /
    • 2007
  • A two-dimensional flutter analysis method (2d-3DOF method) was developed to simultaneously investigate the relationship between oscillation parameters and aerodynamic derivatives of three degrees of freedom, and to clarify the coupling effects of different degrees of freedom in flutter instability. With this method, the flutter mechanism of two typical bridge deck sections, box girder section and two-isolated-girder section, were numerically investigated, and both differences and common ground in these two typical flutter phenomena are summarized. Then the flutter stabilization effect and its mechanism for long-span bridges with box girders by using central-slotting were studied by experimental investigation of aerodynamic stability and theoretical analysis of stabilizing mechanism. Possible explanation of new findings in the evaluation trend of critical wind speed through central vent width is finally presented.

Analysis of Smoke Behavior in Fire within Real-scale Theater Using FDS: Influences of Fire Curtain and Natural Smoke Vent Area (FDS를 이용한 실규모 공연장 무대 내 화재 시 연기 거동 분석: 방화막 및 자연배출구 면적의 영향)

  • Kim, Jae Han;Lee, Chi Young;Jeong, Lee Gyu;Kim, Duncan
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.7-14
    • /
    • 2018
  • This study investigated numerically the influences of fire curtain and natural smoke vent area on smoke movement in the stage fire of a theater using FDS (Fire Dynamics Simulator). The dimension of the theater stage was 31 m in width, 34 m in depth, and 32 m in height. The area ratios between the natural smoke vent and stage were approximately 10%, 8%, 5%, and 1%. The gap distance between the fire curtain and proscenium wall was 0.5 m. The fire curtain and natural smoke vent area were observed to affect significantly the behavior of smoke movement to the auditorium and the mass flow rates of inflow and outflow through the natural smoke vent and proscenium opening. In addition, under the same natural smoke vent area, the pressure in the stage with a fire curtain was lower than that without a fire curtain.

Effects of Modified Installation Methods of Roof Ventilation Devices in the Single-span Plastic Greenhouses on Yield and Fruit Quality of Oriental Melon (단동 비닐하우스의 지붕 환기장치 설치방법 개선이 참외생육 및 과실수량에 미치는 영향)

  • Yeo, Kyung-Hwan;Yu, In-Ho;Choi, Gyeong Lee;Lee, Seong-Chan;Lee, Jae-Han;Park, Kyoungs Sub;Lee, Jung-Sup;Bekhzod, Khoshimkhujaev
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.334-342
    • /
    • 2016
  • In order to evaluate the modified installation methods of roof ventilation devices, derived from the previous experiment ('investigation into the optimum capacity of roof ventilation devices and their deployment'), the conventional and modified (improved) roof ventilation systems were installed in the single-span plastic greenhouse for growing oriental melons. The roof vents ($60{\varphi}$) and roof fans (maximum air capacity of $38m^3/min$) were installed in the spacing of 15m (FT, modified 'side vent+roof fan' ventilation) and 6m (TT, modified 'side vent+roof vent' ventilation) respectively on the roof of greenhouses for the modified roof ventilation treatments, and 20m (FC, conventional 'side vent+roof fan' ventilation) and 8m (TC, conventional 'side vent+roof vent' ventilation) for the conventional ones. The stem diameter, leaf blade lengh, petiole length, and leaf width were lower in the FT and TT treatments than those in the conventional treatments, FC and TC. Although the fruit weight and total yields were slightly lower in the FT and TT treatments, the marketable fruit ratio (%) were higher, as a result of increased fruiting ratio (%) in these treatments, than those of FC and TC. The marketable yields (kg/10a) in the FT and TT treatments were 8,391 kg/10a and 7,283 kg/10a, which were respectively 661 kg/10a and 487 kg/10a higher than those in the treatments of FC and TC. The modified installation methods of roof fan resulted in production of more female flowers and lower fruit drop ratio (%) compared to conventional meathods. In the treatment of the conventional ventilation with roof vent, the fruit weight, fruit length & width, and flesh thickness were higher than in other treatments, but there were no significant differences in the fruit width and flesh thickness among the treatments.

The different Polyphenism by the Level of Predation Risk and Habitat in Larval Salamander, Hynobius ieechii (한국산 도롱뇽의 포식압과 서식지에 따른 polyphenism)

  • Hwang, Ji-Hee;Chung, Hoon
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.6
    • /
    • pp.744-750
    • /
    • 2010
  • This study examined the different polyphenism of larval salamander Hynobius ieechii according to two habitats, pond and stream. We collected salamander's eggs from three regions including Mountain Inwang, Surak and Gwangju. Eggs were treated by four different conditions according to predation level and habitat: high risk - which had a predation risk three times a day; low risk - which had no predation risk, pond and stream habitat. Predation risk was conducted by using chemical cue from Chinese minnows. The chemical cue treatment started from the day of collection and ended one week after the hatching. After the treatment phase, we measured the head width at the level of the eyes(HWE) and the largest head width(LHW) and snout-vent length of the each larva. We calculated the ratio of the head size by dividing HWE by LHW and made a comparison with each of the average ratio of head size according to the predation risk. The results showed that there was a significant difference in the ratio of the head size and snout-vent length according to the predation risk and habitat. From these results we found that predation risk and habitat condition can cause the different polyphenism to the larval salamander and these morphological changes could be affect their mortality.

Sexual Size Dimorphism in the Red-tongued viper snake(Gloydius ussuriensis) of Population (쇠살모사 개체군의 성적 크기이형)

  • Kim, Byoung-Soo;Oh, Hong-Shik
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.5
    • /
    • pp.542-549
    • /
    • 2014
  • This study was conducted to investigate the body size, sexual size dimorphism (SSD), and related environmental factors between Red-tongued viper snakes (Gloydius ussuriensis) inhabiting two different places, i.e., Jeju Island and its islet Gapado, and to provide data required to maintain species diversity from May, 2006 until June, 2009. The snout-vent length of the Red-tongued viper snake population inhabiting Jeju Island was found to be 242-532 mm ($422.0{\pm}46.7mm$, n = 100) in females and 296-580 mm ($434.5{\pm}51.7mm$, n = 63) in males. In contrast, the snout-vent length was observed to be 205-395 mm ($335{\pm}43.6mm$, n = 55) in female and 215-430 mm ($328{\pm}39.4mm$, n = 73) in male Red-tongued viper snakes inhabiting Gapado. These data demonstrated the snout-vent length of both female and male Red-tongued viper snakes on Jeju Island to be larger than those on Gapado (Female t = 17.343, df = 115, P<0.001; Male = 19.128, df = 101, P<0.001). SSD was measured to be -0.03 in the Red-tongued viper snake population on Jeju Island, with more or less larger sizes in the males, while it was 0.02 in the Red-tongued viper snake population in the Gapado, with a little larger sizes in the females. The reason for this difference in the snake populations between Jeju Island and Gapado may be due to adaption to the different ecological environments. In addition, as SSD, the snout-vent length of the Red-tongued viper snake populations and in young vipers was somewhat higher in the males than in the females on Jeju Island (t = -2.011, df = 117, P<0.05). However, no significant differences were observed in the snout-vent length of the young and the general Red-tongued viper snake populations on Gapa Island. For the population on Jeju island, the head length (F = 6.318, $df_{1,2}$=1,117, P<0.05), head width (F=8.090, $df_{1,2}$=1,117, P<0.01), inter eye length (F=15.898, $df_{1,2}$=1,117, P<0.001), and tail length (F=238.488, $df_{1,2}$=1,111, P<0.001) were all larger in the males, while females showed higher body mass (F=64.111, $df_{1,2}$=1,114, P<0.001). In the case of the Gapa Island population, no significant differences in the head length, head width, and inter eye length between females and males were observed, while the males had a longer tail length (F=168.555, $df_{1,2}$=1,74, P<0.001) and the females were heavier (F=17.812, $df_{1,2}$=1,76, P<0.001). Though no significant differences were found in the head length, head width, and inter eye length, the tail length (F=67.793, $df_{1,2}$=1,72, P<0.001) and body mass (F=4.558, $df_{1,2}$=1,72, P<0.05) were higher in the young male Red-tongued viper snakes than in the females. The snout-vent length, head length, head width, and inter eye length, which did not display SSD in the young Red-tongued viper snake populations, were higher in the male Red-tongued viper snake populations than in the female population from Jeju Island, implying that SSD in the Red-tongued viper snake population on Jeju Island is expressed due to environmental effects during their growth.

Courtship, Fighting Behaviors and Sexual Dimorphism of the Salamander, Hynobius leechii (한국산 도롱뇽의 구애 행동, 싸움행동 및 신체적 특징)

  • 박시룡;박대식;양서영
    • The Korean Journal of Zoology
    • /
    • v.39 no.4
    • /
    • pp.437-446
    • /
    • 1996
  • The courtship and fighting behaviors and the sexual dimorphism of the salamander Hynohius leechil were studied. The parameters, snout vent length, body length (from snout to tail tip), and proportion of snout vent length to body size were larger in the female than the male. Five physical parameter in males were significantly correlated with one another, body length, snout vent length, head width, tail vent length, and tall depth, while all, except tail depth, were significantly correlated in females. Sexual behavior of H. leechIl involved external fertilization and consisted of three stages, identifying the female, aifrading the female, and insemination. The identification stage consisted of a positive advance by the male toward the female and display of snout contact. The male attracted the female with chin rubbing, tail undulation, smelling, and digging displays. The insemination process consisted of four phases, amplex, separating egg sacs from the female's cloacal, fertilizing eggs, and post fertilization. liighting behaviors were quite simple. The attacking male would generally bite the opposite male's upper chin or hind limbs and then shakes his head two or three times. The bitten male, which in most cases was of a dissimilar body size, quicidy escaped from the attacking male. After fighting, winning male usually displayed rapid tail undulation.

  • PDF