• Title/Summary/Keyword: velocity variation

Search Result 1,574, Processing Time 0.032 seconds

Design of an Aquifer Thermal Energy Storage System(II) : Thermal Analysis (지하대수층을 이용한 축열시스템의 설계(II) : 열해석)

  • Lee, K.S.;Lee, T.H.;Song, Y.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.315-324
    • /
    • 1994
  • The energy recovery efficiency(ERE) of an aquifer thermal energy storage system was calculated using curvilinear coordinate. The results of the calculation were compared with the experimental results, and agreed within 11% of the discrepancy. The variation of ERE was investigated as a function of the underground water natural velocity, the amount of the stored energy, and period of the energy recovery. The slower the natural velocity and shorter the recovery period, the higher ERE was yielded. Also it was found that increase in the amount of energy storage yields higher ERE, and carries out less influential ERE to the natural velocity. Reiterative usage of the aquifer as a thermal storage tends to gradually increase ERE. The result of this study implements that the aquifer thermal energy storage system is suitable for large cooling/heating loads, such as district cooling/heating.

  • PDF

선단 부하를 갖는 병진운동 단일 링크 탄성암 선단의 closed-loop 제어

  • 정훈;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.185-189
    • /
    • 1992
  • This paper prsents an end-point control of a one-link flexible arm with a payload by using closed loop control. Tip position of arm is shifted by the base motion according to DC servomotor, whivh is driven by a feedback signal composed of the tip displacement and the estimated tip velocity. The shifting problem of the arm from initial position to desired position is considered by the variation of the displacement gain Gd and velocity agin Gv. Theoretical results are obtained by applying the method of the Laplace transform to the governing equations and the method of numerical inversion. This system is composed of a flexible arm with payload, DC servomotor, and a ballscrew mechanism. The flexible arm is mounted on a mobile stage driven by a servomotor and ballscrew. In controlling the tip displacement of flexible arm, the fundamental bode vibration is supressed more rapidly with an increase of the velocity feedback gain Gv and the feedback displacemenmt gain Gd. Theretical responses are approximately in good agreement with those obtained experimentally.

Sub-micron Control Algorithm for Grinding and Polishing Aspherical Surface

  • Kim, Hyung-Tae;Yang, Hae-Jeong;Kim, Sung-Chul
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.3
    • /
    • pp.386-393
    • /
    • 2008
  • A position control method for interpolating aspherical grinding and polishing tool path was reviewed and experimented in a nano precision machine. The position-base algorithm was reformed from the time-base algorithm, proposed in the previous study. The characteristics of the algorithm were in the velocity control loop with position feedback. The aspherical surface was divided by an interval at which each velocity and acceleration were calculated. The theoretical velocity was corrected by position error during processing. In the experiment, a machine was constructed and nano-scale linear encoders were installed at each axis. Relation between process parameters and the variation of position error was monitored and discussed. The best result from optimized parameters showed that the accuracy was 150nm and improved from the previous report.

Behaviour of GFRP composite plate under ballistic impact: experimental and FE analyses

  • Ansari, Md. Muslim;Chakrabarti, Anupam
    • Structural Engineering and Mechanics
    • /
    • v.60 no.5
    • /
    • pp.829-849
    • /
    • 2016
  • In this paper, experimental as well as numerical analysis of Glass Fiber Reinforced Polymer (GFRP) laminated composite has been presented under ballistic impact with varying projectile nose shapes (conical, ogival and spherical) and incidence velocities. The experimental impact tests on GFRP composite plate reinforced with woven glass fiber ($0^{\circ}/90^{\circ}$)s are performed by using pneumatic gun. A three dimensional finite element model is developed in AUTODYN hydro code to validate the experimental results and to study the ballistic perforation characteristic of the target with different parametric variations. The influence of projectile nose shapes, plate thickness and incidence velocity on the variation of residual velocity, ballistic limit, contact force-time histories, energy absorption, damage pattern and damage area in the composite target have been studied. The material characterization of GFRP composite is carried out as required for the progressive damage analysis of composite. The numerical results from the present FE model in terms of residual velocity, absorbed energy, damage pattern and damage area are having close agreement with the results from the experimental impact tests.

NUMERICAL STUDY ON THE CHARACTERISTICS OF VORTEX FREQUENCY AND LAMINAR MIXING OF A PASSIVE SCALAR IN COAXIAL JET FLOWS (동축제트의 와류주파수 및 혼합특성에 대한 수치해석)

  • Kim, Won-Hyun;Park, Tae-Seon
    • Journal of computational fluids engineering
    • /
    • v.14 no.3
    • /
    • pp.49-55
    • /
    • 2009
  • This study focuses on the near-field vortical structure and dynamics of coaxial jets. The characteristics of laminar flow and mixing in coaxial jets are investigated using a unsteady flow simulation. In order to analyze the geometric effects on the vortical structure, several cases of different configurations are selected for various values of the velocity ratio of inner jet to outer jet. From the result, it is confirmed that the flow mixing is promoted by the development of vortical structure and the interaction between inner jet and outer jet. This feature is strongly related to the vortex frequency in the shear-layers. The vortex frequency depends on the velocity ratio and the lip thickness of inner nozzle, but the outer pipe length has no effect on the frequency variation.

Nondestructive Evaluation of Ceramic/Metal Interface Using the V(z) Curve of Scanning Acoustic Microscope (초음파현미경에서 V(z) 곡선을 이용한 세라믹/금속 접합계면의 비파괴평가)

  • Park Ik-Keun;Lee Chul-Ku;Cho Dong-Su;Kim Yong-Kwon
    • Journal of Welding and Joining
    • /
    • v.23 no.2
    • /
    • pp.59-65
    • /
    • 2005
  • A leaky surface acoustic wave (LSAW) velocity was measured using a scanning acoustic microscope on the ceramic/metal interface in order to investigate material properties. The inverse Fourier transform (IFFT) of the V(z) curve contains the reflectance function of a liquid-specimen interface. So, the longitudinal, transverse, and Rayleigh wave velocities for each layer are obtained by the inversion of the V(z) curve at the same time. This paper contains mainly the experimental procedure for measurements of the LSAW velocity, and the results obtained for the velocity variation of individual layer after the thermal shock. It is shown that this method is useful in measuring the material properties under external stress.

Analysis of In-Cylinder Steady Flow for Gasoline Engine Using Particle Tracking Velocimetry (입자추적법을 이용한 가솔린 기관의 실린더 내 정상유동 해석)

  • 정구섭;전충환;장영준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.34-43
    • /
    • 2001
  • Analysis and control of intake charge motion such as swirl and tumble are very important to improve the performance of gasoline engines. In this paper, single frame double exposure PTV(particle tracking velocimetry) is used to investigate intake flow characteristic in a steady flow test rig of gasoline engine with 2-valve and pent-roof combustion chamber. To validate this PTV method, we confirmed reliability of this PTV method using chopper, and coaxial burner experiments. The velocity Held of intake flow is measured with the intake valve lift variation. It is shown that maximum flow velocity is increased and tumble flow become stronger than inverse tumble flow as valve lift increase.

  • PDF

Effect of the Processing Condition to the Yarn Tension on the Belt-type Texturing m/c (벨트 가연기의 공정조건에 따른 장력변화)

  • 이민수;김승진;박경순
    • Textile Coloration and Finishing
    • /
    • v.16 no.1
    • /
    • pp.1-4
    • /
    • 2004
  • This research surveys the twisting and untwisting tensions according to the various processing conditions of belt type texturing such as draw ratio, 1st heater temperature and velocity ratio. The 1st heater temperature was changed from 1606{\circ}C\; to\; 220^{\circ}C$, draw ratio was changed from 1.6 to 1.9 and velocity ratio was changed from 1.4 to 1.8. The twisting and untwisting tensions are measured with the variation of these processing conditions, in addition, the untwisting tension(T2) and tension ratio(T2/Tl) according to the various processing conditions are analysed with the false twist mechanism which is affected to the physical properties of draw textured yams.

A study on the development of Pulsed Doppler System using Auto-Correlation (Auto-Correlation을 이용한 펄스 도플러 시스템에 관한 연구)

  • Lim, Chun-Sung;Rang, Chung-Shin;Lee, Hang-Sei;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.705-708
    • /
    • 1988
  • Ultrasound Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. Pulsed Doppler System uses Phase detector and zerocrossing method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time domain, had been fabricated. But time-domain analyzing such as audio evaluation and zerocrossing detection for instantaneous and mean frequency measurement doesn't, provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency domain technique to improve system performance. In this paper, we describe a unit which is composed of Pulsed Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of blood Signal.

  • PDF

A study on the development of CW(Continuous-Wave) Doppler System using FFT (FFT를 이용한 연속초음파 도플러 장치에 관한 연구)

  • Lee, Dae-Hyung;Kang, Chung-Shin;Park, Sei-Hyun;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.709-712
    • /
    • 1988
  • Ultrasonic Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. CW(Continuous-Wave) Doppler System uses quadrature detection and phase rotation method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time-domain, had been fabricated. But time-domain analyzing such as audio evaluation and zero- crossing detection for instantaneous and mean frequnecy measurement do not provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency-domain technique to improve system performance. In this paper, we describe a unit which is composed of CW Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of Blood signal.

  • PDF