• Title/Summary/Keyword: velocity gradient

Search Result 584, Processing Time 0.029 seconds

Double Outlet Right Ventricle in a Maltese Dog (말티스견에서 발생한 양대혈관 우심실기시)

  • Lee, Jong-Sung;Choi, Ran;Han, Suk-Hee;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.735-739
    • /
    • 2010
  • An 8 month old female Maltese (body weight 3.6 kg) was referred with primary complaints of dyspnea and exercise intolerance. Diagnostic imaging studies revealed marked cardiomegaly and prominent main pulmonary trunk dilation on thoracic radiography, abnormally arisen aortic roots (toward right ventricle) with left-to right shunted perimembraneous ventricular septal defect located underneath of aortic root, aortic root was located to predominantly to the right ventricle and pulmonary regurgitation (peak velocity 4.7 m/s, pressure gradient ~88 mmHg) from pulmonary over-circulation and hypertension on echocardiography, indicating double outlet right ventricle (DORV). The dog was treated with furosemide (1 mg/kg, BID) for reducing volume overload at right ventricle, spironolatcone (1 mg/kg) and enalapril (0.5 mg/kg) for minimizing deleterious cardiac remodeling, and sildenafil (1 mg/kg) for lessening pulmonary over-circulation and hypertension. The clinical condition of this dog was improved after 1 week of medical treatment. The dog is currently survived and regularly monitored.

Laminar Convective Heat Transfer in Vertical Square Duct with Variational Symmetric Heat Flux (비균일 대칭성 열Flux인 수직 사각 닥트내의 층류조합대류 열전달 효과)

  • 김시영
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.18 no.1
    • /
    • pp.47-53
    • /
    • 1982
  • An analysis of convection, in a fully developed laminar steady flow through the vertical square duct under the condition of variational symmetric heat flux, is considered. Finite element solution algorithm by Galerkin's method with triangular elements and linear interpolation polynominals for the temperature and velocity profiles are derived for the vertical square duct. The comparison of temperature distribution due to variational symmetric heat flux in the duct were made with available the other data when the condition of peripheral heat flux were uniform and zero. Numerical values for the dimensionless temperatures and Nusselt numbers at selected Rayleigh numbers and pressure gradient parameters were obtained at a few nodal points for the vertical square ducts and effects of corner in the duct were investigated.

  • PDF

A Performance Study of Vent Mixer with Geometric Characteristics in Supersonic Flow (초음속 유동 내 벤트 혼합기의 형상적 특성에 따른 성능 연구)

  • Kim, Chae-Hyoung;Jeung, In-Seuck
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.1
    • /
    • pp.69-75
    • /
    • 2009
  • This paper studies the aerodynamic performance that the vent mixer-new conceptual supersonic mixer-showed with its geometric characteristics. The hole is 2 mm with 2 mm's distance from the wall in case 1 and with no distance in case 2. In case 3 die hole is 1 mm. Case 1 and case 2 showed the same total pressure recovery ratio, of which the case 3 was lower than that. While cases 1-3 had the same reattachment length, the shear layer was thicker in cases 1 and 2 than in case 3. Within the recirculation zone, cases 1 and 2 had lower pressure loss and higher velocity gradient difference than case 3-they enhance mixing between air and fuel. Separation bubble which is developed by the inflow into the recirculation zone has a significant effect on the total pressure recovery ratio in the combustor. Also separation bubble influences pressure distributions and recirculation flows in the recirculation zone. Therefore, inflow rate of air into the recirculation zone mainly affects the performance of vent mixer.

A study on the biomechanical modeling of human pharynx by using FEM(Finite Element Method) (유한요소기법에 의한 인두의 생체역학모델에 관한 연구)

  • Kim, Seong-Min;Kim, Nam-Hyeon
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.423-429
    • /
    • 1998
  • Human pharynx is unique, acting as a complex interchange between the oral cavity and esophagus, and between the nasal cavity and lungs. It is actively involved in the transport of food and liquid, producing the forces that guide that bolus into the upper esophagus and away from the adjacent larynx and lungs. This study intended to develop a biomechanical model of the human pharynx, utilizing Finite Element Method(FEM). Within each model changes in cross sectional intralumenal area were calculated and compared with the area from the computer-generated FE model. Area matching allowed estimation of intraluminal pressure gradients during swallow. The estimated pharyngeal pressure gradient varies from one region to another. The estimated pharyngeal pressure gradients showed different patterns for upper four levels and lower four levels. The contraction velocity for upper four levels is much higher than lower four levels. The higher contraction velocities and pressure gradients in the upper levels are consistent with the bolus velocities required for efficient swallow.

  • PDF

A Case of Supravalvular Pulmonic Stenosis in a Maltese Dog (말티즈견에서 발생한 판막상형 폐동맥판 협착증 증례)

  • Kim, Seong-Jun;Kang, Min-Hee;Kim, Su-Chan;Choi, Young-Chul;Kim, Seung-Gon;Lee, Chang-Min;Jung, Da-Min;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.31 no.4
    • /
    • pp.325-328
    • /
    • 2014
  • A 8-month-old female Maltese dog was presented with a history of heart murmur. In physical examination, grade 4/6 systolic murmur heard at the left heart base. Electrocardiography showed sinus arrhythmia, right axis deviation, deep S wave and splintered QRS complex. Thoracic radiography revealed enlarged right side heart and bulging of the main pulmonary artery. Echocardiography showed mild hypertrophy of right ventricle, a supravalvular stenosis, marked post-stenotic dilation of the main pulmonary artery and a moderately increased pulmonary arterial velocity through the stenotic area (4.4 m/s, pressure gradient of 78.7 mmHg). The dog was diagnosed with supravalvular pulmonic stenosis based on the diagnostic imaging findings. Medical management using ${\beta}1$-blocker and ACE inhibitor was started in this dog and this is first case report described diagnostic characteristic features of supravalvular pulmonic stenosis in korea.

Numerical Analysis of Hydrograph Determination for Cohesive Soil Levee (조립토 하천제방의 수위파형결정에 관한 수치해석적 연구)

  • Kim, Jin-Man;Kim, Ji-Sung;Oh, Eun-Ho;Cho, Won-Beom
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.4
    • /
    • pp.81-92
    • /
    • 2014
  • The integrity evaluation of river levee includes slope stability evaluation of riverside land and protected low-land, and safety of piping with respect to critical gradient and critical velocity based on related regulations, such as Design Criteria Rivers Commentary (2009), Structural Design Criteria Based Commentary (2009). The design hydro-graph is the most important design input factor for the integrity evaluation; it can be inaccurate due to the absence of its decision methods suggested by the national level. The authors in this paper evaluated numerical analytic levee integrity for piping and slope stability by changing each design hydro-graph, including rising ordinary water level, lasting flood water level, falling water level, and flood frequency for Mun-san-jae on Nak-dong River. Finally, the authors suggested that the levee integrity of piping and slope stability are very sensitive to the changes of increasing time of ordinary water level by 57 hours and lasting time of the flood water level by 53 hours, respectively, for Mun-san-jae.

PULSATILE FLOW SIMULATION OF A NON-NEWTONIAN FLUID THROUGH A BIFURCATION TUBE USING THE CFD ANALYSIS (CFD를 이용한 분지관 비뉴턴 해석)

  • Hwang, D.;Yoo, S.S.;Park, H.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.177-180
    • /
    • 2008
  • The objective of this study is to get simulation data about pulsatile flow of a non-Newtonian fluid through a bifurcated tube. All the process was based on CFD method, with a commercial FVM code, SC/Tetra ver. 6.0 for solving, and with CATIA R16 for generating geometries. To define a non-Newtonian fluid, the following viscous models are used; the Powell-Eyring model, the modified Powell-Eyring model, the Cross model, the modified Cross model, the Carreau model, the Carreau-Yasuda model and the modified Power Law model. The flow calculation data using each model were compared with the other data of a existing paper. Finally, the Carreau model was recognized to give the best result with the SC/Tetra code, and the succeeding simulations are made with the model. For the pulsating flow condition, the sine wave type velocity profile is given as the inlet boundary condition. To investigate the effect of geometries and mesh, the pre-test is carried out with various curvature conditions of the bifurcated corner, and then with various mesh conditions. The final process is to calculate flow variables such as the wall shear stress (WSS) and the wall shear stress gradient (WSSG). To validate all the result, the simulation is compared with the existing data of the other papers. Generally speaking, there is a noticeable difference in the maximum and minimum value of WSS. It is not sure that the values in each data are on the exactly same location. However, the overall trend is similar. The next study needs to investigate the same situation by experimental method. Furthermore, if the flow is simulated with more pulsatile conditions, more data of flow field through a bifurcated tube could be achieved.

  • PDF

Wall Shear Stress Between Compliant Plates Under Oscillatory Flow Conditions: Influence of Wall Motion, Impedance Phase Angle and Non-Newtonian Fluid (맥동유동하에 있는 유연성 있는 평판 사이의 벽면전단응력: 벽면운동과 임피던스 페이즈 앵글과 비뉴턴유체의 영향)

  • Choe, Ju-Hwan;Lee, Jong-Seon;Kim, Chan-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.18-28
    • /
    • 2001
  • The present study investigates flow dynamics between two dimensional compliant plates under sinusoidal flow conditions in order to understand influence of wall motion, impedance phase angle (time delay between pressure and flow waveforms), and non-Newtonian fluid on wall shear stress using computational fluid dynamics. The results showed that wall motion induced additional terms in the streamwise velocity profile and the pressure gradient. These additional terms due to wall motion reduced the amplitude of wall shear stress and also changed the mean wall shear stress. The trend of the changes was very different depending on the impedance phase angle. As the impedance phase angle was changed to more negative values, the mean wall shear stress decreased while the amplitude of wall shear stress increased. As the phase angle was reduced from 0°to -90°under $\pm$4% wall motion, the mean wall shear stress decreased by 12% and the amplitude of wall shear stress increased by 9%. Therefore, for hypertensive patients who have large negative phase angles, the ratio of amplitude and mean of the wall shear stress is raised resulting in a more vulnerable state to atherosclerosis according to the low and oscillatory shear stress theory. We also found that non-Newtonian characteristics of the blood protect atherosclerosis by decreasing the oscillatory shear index.

PULSATILE FLOW SIMULATION OF A NON-NEWTONIAN FLUID THROUGH A BIFURCATION TUBE USING THE CFD ANALYSIS (CFD를 이용한 분지관 비뉴턴 해석)

  • Hwang, D.;Yoo, S.S.;Park, H.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.177-180
    • /
    • 2008
  • The objective of this study is to get simulation data about pulsatile flow of a non-Newtonian fluid through a bifurcated tube. All the process was based on CFD method, with a commercial FVM code, SC/Tetra ver. 6.0 for solving, and with CATIA R16 for generating geometries. To define a non-Newtonian fluid, the following viscous models are used; the Powell-Eyring model, the modified Powell-Eyring model, the Cross model, the modified Cross model, the Carreau model, the Carreau-Yasuda model and the modified Power Law model. The flow calculation data using each model were compared with the other data of a existing paper. Finally, the Carreau model was recognized to give the best result with the SC/Tetra code, and the succeeding simulations are made with the model. For the pulsating flow condition, the sine wave type velocity profile is given as the inlet boundary condition. To investigate the effect of geometries and mesh, the pre-test is carried out with various curvature conditions of the bifurcated corner, and then with various mesh conditions. The final process is to calculate flow variables such as the wall shear stress (WSS) and the wall shear stress gradient (WSSG). To validate all the result, the simulation is compared with the existing data of the other papers. Generally speaking, there is a noticeable difference in the maximum and minimum value of WSS. It is not sure that the values in each data are on the exactly same location. However, the overall trend is similar. The next study needs to investigate the same situation by experimental method. Furthermore, if the flow is simulated with more pulsatile conditions, more data of flow field through a bifurcated tube could be achieved.

  • PDF

A Numerical Study on the Heat and Fluid Flow in Steam Reforming Reactor (수증기 개질 반응로에 대한 열유동 해석)

  • Han, Jeongok;Lee, Joongseong;Lee, Yeongcheol;Hong, Seongho;Hong, Sungkook;Dong, Sangkeun
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.78-84
    • /
    • 2013
  • A numerical study on the heat and fluid flow has carried out for the design of the steam reforming reactor which consists of six reforming tubes and one burner. Reforming reaction calculation is coupled with the heat and fluid flow one. The burner type in the reforming reactor is chosen through the fluid flow calculation according to different type of burner structure. It is shown that the significant temperature gradient exists in the reforming reactor, affecting the component variation along the length of reforming tube. The component ratio of reforming gas is changed by the variation of SCR and GHSV.