• Title/Summary/Keyword: various indoor environment

Search Result 446, Processing Time 0.026 seconds

A Study on the Design Prototype Development of Underfloor Air-Conditioning System(UFAC) for Improving Indoor Environment (바닥급기 공조시스템(UFAC)을 적용한 작업공간의 실내환경 평가기법 개발연구)

  • 정광섭;한화택
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.325-336
    • /
    • 2000
  • During the last decade, an increasing interest in Underfloor Air-Conditioning(UFAC) systems has emerged. The purpose of this paper is to evaluate comprehensively the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. In this paper, the physical measurements and the interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation(POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey.

  • PDF

Indoor comfort environment modeling engine (실내 쾌적성 모델링 엔진)

  • Lee, Jae-Min;Jeong, Hye-Seong;Kim, Dong-Ju;Jeong, Hoe-Joong;Kim, Ji-Won;Do, Yun-Hyung;Lee, Kang-Whan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.536-539
    • /
    • 2018
  • In this paper, we propose a system that analyzes environment information by using deep learning and then provides a suitable environment for users by predicting environmental information change. As the level of living improves, interest in improving the quality of life is increasing. In particular, as the air quality deteriorated due to the recent occurrence of dust, smog, fine dust, and ultrafine dust, the indoor air quality as well as the outdoor air became a serious problem. The increase of indoor pollution due to the lack of ventilation and the use of chemicals is a serious problem for modern people who have a lot of indoor living. In order to solve this indoor air pollution, a system has been proposed that measures the state of air quality through sensors and maintains proper temperature and humidity. However, existing system has a difficulty to apply most of the atmospheric environment information to various users depending on sensors only. The system proposed in this paper predicts the indoor environment by analyzing the indoor pollution information collected through the sensor using the deep learning. Then, the predicted indoor environment is modeled and learned in this system, and the environment suitable for the user is suggested. Afterwards, the system receives feedback from the user and repeats the process of re-learning the proposed environment so that it can create the optimal environment for the user.

  • PDF

Development of Real-time Environment Monitoring System Using 3G Integrated Environmental Sensors Based on AWS (AWS기반 3G 통합환경센서 모듈을 이용한 실시간 환경 모니터링 시스템 개발)

  • Chun, Seung-Man;Lee, Seung-Jun;Yun, Jang-Kyu;Suk, Soo-Young
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.13 no.2
    • /
    • pp.101-107
    • /
    • 2018
  • As indoor pollutants such as carbon dioxide and dust mainly affect the respiratory and circulatory systems, there is an increasing need for real-time indoor / outdoor environmental monitoring. In this paper, we have developed a real - time environmental monitoring system using the cloud-based 3G integrated environmental sensor module for environmental monitoring. A highly reliable environmental information monitoring system requires various IT technologies such as infrastructure (server, commercial software, etc.), service application software, security, and authentication. A real-time environment monitoring system based on cloud service that can provide reliable service satisfying these configuration requirements is proposed and implemented. It is expected that this system can be applied to various technologies such as indoor automatic window opening/closing system based on the Internet.

Fine Dust Adsorption of Cement Matrix Using Sepiolite (세피올라이트를 활용한 시멘트 경화체의 미세먼지 흡착 특성 )

  • Jeon, Eun-Yeong;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.71-72
    • /
    • 2023
  • As industrialization and urbanization accelerate, environmental issues have moved from local concerns to global issues. Among them, air pollution is the most important issue. Modern people spend more than 88% of their day indoors, but the concentration of fine dust and pollutants flowing indoors is increasing. The indoor environment has its own complexity, and various substances used indoors, such as building materials, furniture, electronics, and cleaning agents, emit chemical substances and cause various diseases. Therefore, when selecting building materials and interior finishing materials, the pollutant emission and adsorption capacity must be greatly considered. These considerations will ensure the construction of a sustainable future environment and a healthy life within that environment. Therefore, in order to reduce the generation of indoor air pollutants, this study aims to examine the fine dust adsorption properties of cement hardening materials using sepiolite, which has a porous structure and high absorption power among clay minerals. As a result of the experiment, it was found that the concentration of fine dust decreased as the addition rate of sepiolite increased. It is believed that the fine dust concentration was reduced due to the high porosity due to the microfibrous structure and large specific surface area of sepiolite, which has a porous structure among clay minerals. It is believed that these experimental results can be used as basic research for future use of sepiolite as a construction material.

  • PDF

Enhanced Indoor Positioning Algorithm Using WLAN RSSI Measurements Considering the Relative Position Information of AP Configuration (AP 상대위치 정보를 고려한 향상된 WLAN RSSI 기반 실내 측위 알고리즘)

  • Kim, A Sol;Hwang, Jungyu;Park, Joongoo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.2
    • /
    • pp.146-151
    • /
    • 2013
  • With the development of mobile internet, requirements of positioning accuracy for the LBS (Location Based Service) are becoming more and more higher. The LBS is based on the position of each mobile device. So, it requires a proper acquisition of accurate user's indoor position. Thus indoor positioning technology and its accuracy is crucial for various LBS. In general, RSSI (Received Signal Strength Indicator) measurements are used to obtain the position information of mobile unit under WLAN environment. However, indoor positioning error increases as multiple AP's configurations are becoming more complex. To overcome this problem, an enhanced indoor localization method by AP (Access Point) selection criteria adopting DOP (Dilution of Precision) is proposed.

Evaluation of Indoor Environmental Factors in Office Building with Underfloor Air-Conditioning (UFAC) System

  • Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.3
    • /
    • pp.36-45
    • /
    • 2001
  • During the last decade, an increasing interest in Underfloor Air-Conditioning (UFAC) systems has emerged. The purpose of this paper is to evaluate the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. The physical measurements and the Interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation (POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey .

  • PDF

A Fundamental Study on the Corrention of Image by Different CCT - Using Photoshop CS2 (색온도에 따른 이미지 보정에 관한 기초적 연구 -Photoshop CS2 활용-)

  • Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.97-100
    • /
    • 2007
  • Recently, since adjustment systems of various CCT(Correlated Color Temperature) are much developed, lighting environment of indoor has created by such various CCT lighting systems. If an indoor image of fixed CCT will quickly correct images of various CCT, lighting or interior designers can utilize it to persuade his or her clients in the indoor lighting planning process. Therefore, this paper presents fundamental data which are RGB data of seven color images for the correction of image by three different CCT.

  • PDF

Indoor, Outdoor, and Personal Exposure to Nitrogen Dioxide Comparing Industrial Complex Area with Country Area (공단지역과 시골지역 주택 실내, 실외 및 개인의 이산화질소 노출평가)

  • Yang, Won-Ho;Im, Sung-Guk;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.183-187
    • /
    • 2008
  • Indoor air quality can be affected by indoor sources, ventilation, decay, and outdoor levels. Various indoor and out-door combustion sources produce nitrogen dioxide ($NO_2$), which is a by-product of high temperature fossil fuel combustion. Especially, the presence of gas ranges and smoking have been identified as major factors contributing to indoor $NO_2$ exposures. In this study, we compared an industrial complex area with a country area by assessing the personal exposure to $NO_2$with measurements of indoor and outdoor $NO_2$ levels in residences and by house characteristics and questionnaire. Personal exposure concentrations were significantly correlated with indoor $NO_2$ concentrations of residences in both the industrial complex area and the country area with correlation coefficients of 0.561 and 0.664, respectively, compared to outdoors. Multiple regression analysis, indicated that indoor $NO_2$ levels in residences were only affected by outdoor levels (p = 0.000) in spite of higher indoor sources such as smoking. Therefore, it is suggested that outdoor air quality as well as indoor air quality should be considered in the reduction of the personal exposure to air pollutants.

A Study on Characteristics of Sensory Richness Towards Healing Environments at the Lobby of Geriatric Hospital Using Biophilic Design Approach (바이오필릭 디자인에 기반한 노인요양병원 로비공간의 다감각적 치유환경에 관한 연구)

  • Lee, Dami;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.3
    • /
    • pp.21-30
    • /
    • 2016
  • For the elderly with declining sensory due to aging, various sense stimulation factors provided in indoor environment is desirable healing environment. This study aims to propose the direction of sensory healing environment by adapting the richness of natural environment in indoor place based on the biophilic design theory with implementation method of sensory richness environment. The healing environment was limited to the ward in the beginning, but it has widened its range to the whole place, and the lobby is considered quiet important to healing. Therefore, this study selected lobby space of geriatric hospital as study subject. As for the study method, we deducted the analytic matrix focusing on the property and elements of the direct and indirect experience of nature appearing in the biophilic design theory, and analyzed the field investigation of subject space. Also, this study paid attention to point where the hotel lobby leads the change of emotional environment, and conducted analysis and comparison by deciding this is what the hotel and geriatric hospital should direct to. As the result, the biophilic design factor of hotel is actively expressed by complex direction of various factors, but as for the geriatric hospital, it was rather passive and simple in expression. The adaptation ratio between hotel and geriatric hospital was almost more than twice times difference in average.

Personal Exposure Level and Health Risk Assessment of Nitrogen Dioxide in an Industrial Area (일부 공단지역 내 이산화질소의 개인노출 농도 및 건강위해성평가)

  • Jeon, Young-Taek;Yang, Won-Ho;Yu, Seung-Do;Lee, Jong-Dae;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.199-206
    • /
    • 2008
  • This study was conducted to estimate nitrogen dioxide levels and health risk in various locations/situations for two groups. The nitrogen dioxide levels were measured for residents of a study group (industrial area within 5 km) and a control group (15 km farther), respectively using the nitrogen dioxide filter badge as a passive sampler from August, 2006 to September, 2006. The means of indoor, outdoor, work and personal levels of nitrogen dioxide were $34.65{\pm}1.95\;{\mu}g/m^3$, $34.83{\pm}11.78\;{\mu}g/m^3$, $34.98{\pm}19.11$ and $35.38{\pm}10.74$ respectively in the study area. Mean ratio of indoor to outdoor $NO_2$ concentration was 0.99. The means of indoor, outdoor and personal level of nitrogen dioxide were $23.66{\pm}7.19\;{\mu}g/m^3$, $18.22{\pm}4.06\;{\mu}g/m^3$ and $27.27{\pm}18.93\;{\mu}g/m^3$ respectively in the control area. Mean ratio of indoor to outdoor $NO_2$ concentration was 1.39. People spent 80.9% of their time in indoor at the study area and 76.9% at the control area. The percentages of time spent in outdoor were 14.9% and 20.9% at the study area and the control area respectively. The percentages of time spent in a car were 4.2% and 2.2% in the study and control areas respectively. The levels of indoor, outdoor, workplace nitrogen dioxide in the study area and the control area were found below the permissible level of health-hazardous effects.