• Title/Summary/Keyword: vapor detection

Search Result 136, Processing Time 0.025 seconds

Mercury Concentration in Urban and Rural Atmospheres of Korea

  • Sohn, Dong-Hun;Shin, Jung-Eun;Jung, Sung-Yun;Jung, Won-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.E
    • /
    • pp.55-62
    • /
    • 1995
  • The distribution of airborne mercury was investigated from several districts of Seoul, five other major cities and two rural areas during the period April, 1994 to March, 1995. The method used in this study involves absorption of gaseous mercury on CHromosorb$^R$ A coated with gold and detection by cold vapor atomic absorption spectroscopy. The atmospheric mercury concentrations in Seoul ranged from N.D. to 120.17 ng m$^3$ (mean 27.01 $\pm 9.42 ng m^{-3}, N=139$), while those in rural areas ranged from 1.72 to 8.24 ng $m^{-3} (mean 4.57 \pm 3.07 ng m^{-3}, N=5$). The spatial distribution characteristics of mercury distribution in urban air were examined by comparing mercury levels as a function of the distance from the urban center. Temporal distribution trends of airborne mercury were also studied using the monthly mean mercury data of various districts in Seoul. The atmospheric mercury concentration around Mokdong wastes incinerator in Seoul were also investigated.

  • PDF

Onset Date of Forest Canopy Detected from MODIS Leaf Area Index

  • Kim, So-Hee;Kang, Sin-Kyu;Lim, Jong-Hwan
    • Journal of Ecology and Environment
    • /
    • v.31 no.2
    • /
    • pp.153-159
    • /
    • 2008
  • The timing of the canopy phenology onset (CPO hereafter) indicates the initiation of the growing season, with rapid increases in exchange rates of carbon dioxide and water vapor between vegetation and atmosphere. The CPO is regarded as a potential indicator of ecosystem responses to global warming, but the CPO shows considerable spatial variation depending on the species composition and local temperature regime. at a given geographic location. In this study, we evaluated the utility of satellite observation data for detection of the timing of the CPO. Leaf area indices (LAI) obtained from the Moderate Resolution Imaging Spectrora-diometer (MODIS) were utilized to detect and map the onset dates from 2001 to 2006. The reliability of MODIS-based onset dates was evaluated with ground measured cherry blossom flowering data from national weather stations. The MODIS onset dates preceded the observed flowering dates by 8 days and were linearly related with a correlation coefficient of 0.58 (p < 0.05). In spite of the coarse spatial (1 km) and temporal (8 days) resolutions of MODIS LAI, the MODIS-based onset dates showed reasonable ability to predict flowering dates.

DNA-functionalized single-walled carbon nanotube-based sensor array for gas monitoring

  • Zhang, Wenjun;Liu, Yu;Wang, Ming. L
    • Smart Structures and Systems
    • /
    • v.12 no.1
    • /
    • pp.73-95
    • /
    • 2013
  • Nine deoxyribonucleic acid (DNA) sequences were used to functionalize single-walled carbon nanotube (SWNT) sensors to detect the trace amount of methanol, acetone, and HCl in vapor. DNA 24 Ma (24 randomly arranged nitrogenous bases with one amine at each end of it) decorated SWNT sensor and DNA 24 A (only adenine (A) base with a length of 24) decorated SWNT sensor have demonstrated the largest sensing responses towards acetone and HCl, respectively. On the other hand, for the DNA GT decorated SWNT sensors with different sequence lengths, the optimum DNA sequence length for acetone and HCl sensing is 32 and 8, separately. The detection of methanol, acetone, and HCl have identified that DNA functionalized SWNT sensors exhibit great selectivity, sensitivity, and repeatability with an accuracy of more than 90%. Further, a sensor array composed of SWNT functionalized with various DNA sequences was utilized to identify acetone and HCl through pattern recognition. The sensor array is a combination of four different DNA functionalized SWNT sensors and two bare SWNT sensors (work as reference). This wireless sensing system has enabled real-time gas monitoring and air quality assurance for safety and security.

Calibration Methods for the Gas Chromatographic Analysis of ppt-level Hydrogen Sulfide (H2) in Air (환경 대기 중 ppt 수준의 황화수소 분석을 위한 GC 방식의 검량 기법에 대한 연구)

  • 김기현;오상인;최여진;최규훈;주도원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.679-687
    • /
    • 2003
  • In this study, we investigated the analytical techniques to quantify the ambient concentration of hydrogen sulfide (H$_2$S) in air at ppt concentration level. For this purpose, an on-line GC analytical system equipped with both pulsed-flame photometric detector (PFPD) and thermal desorption unit (TDU) was investigated by collecting ambient air samples. The results of our study generally indicated that calibration conditions of GC system is highly sensitive to affect the accuracy of the analytical technique. Most importantly. we found that the use of different matrices in the the preparation stage of working standards was sensitive to control the overall performance of this technique. The calibration of our analytical system was tested by the two types of working standard (prepared by mixing either with high purity $N_2$ or with the ambient air). According to this test, the latter represented more efficiently the detecting conditions of actual air samples. The peak occurrence patterns of both air samples and standards (prepared by mixing with ambient air) were altered in a similar manner as the function of the loaded volume; however, it was not the case for the $N_2$-mixed standards. Results of our study suggest that detection of H$_2$S is highly different from other sulfides and that its quantification requires minimiaing interfering effects of non -pure substance (like water vapor) and (either sorptive or destructive) loss effects.

Detection of Organic Vapors Using Change of Fabry-Perot Fringe Pattern of Surface Functionalized Porous Silicon (표면 기능성을 가진 다공성 실리콘의 Fabry-Perot fringe pattern의 변화를 이용한 유기 화합물의 감지)

  • Hwang, Minwoo;Cho, Sungdong
    • Journal of Integrative Natural Science
    • /
    • v.3 no.3
    • /
    • pp.168-173
    • /
    • 2010
  • Novel porous silicon chip exhibiting dual optical properties, both Frbry-Perot fringe (optical reflectivity) and photoluminescence had been developed and used as chemical sensors. Porous silicon samples were prepared by an electrochemical etch of p-type sillicon wafer (boron-doped, <100> orientation, resistivity 1 - 10 ${\Omega}$). The ething solution was prepared by adding an equal volume of pure ethanol to an aqueous solution of HF (48% by weight). The porous silicon was illuminated with a 300 W tungsten lamp for the duration of etch. Ething was carried out as a two-electrode Kithley 2420 preocedure at an anodic current. The surface of porous silicon was characterized by FT-IR instrument. The porosity of samples was about 80%. Three different types of porous silicon, fresh porous silicon (Si-H termianated), oxidized porous silicon (Si-OH terminated), and surface-derivatized porous silicon (Si-R terminated), were prepared by the thermal oxidation and hydrosilylation. Then the samples were exposed to the wapor of various organics vapors. such as chloroform, hexane, methanol, benzene, isopropanol, and toluene. Both reflectivity and photoluminescence were simultaneously measured under the exposure of organic wapors.

Discrimination of Gasoline and Diesel Fuels Using Oxide Semiconductor Gas Sensors

  • Moon, Young Kook;Shin, Min Sung;Jo, Young-Moo;Lim, Kyeorei;Lee, Jong-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.221-226
    • /
    • 2018
  • Misfueling accidents significantly damage the engines of both gasoline and diesel vehicles, and should be avoided by rapid and accurate fuel discrimination. Gasoline fuel contains bioethanol. Thus, the detection of ethanol vapor produced by gasoline can be used to distinguish between gasoline and diesel. In the present study, Pt-doped $SnO_2$ hollow nanospheres, Mg-doped $In_2O_3$ hollow microspheres, and Pt-doped ZnO nanostructures have been used as gas sensors to discriminate between gasoline and diesel fuels. All three sensors are able to detect and discriminate between gases evaporating from gasoline and diesel. Among the sensors, the Mg-doped $In_2O_3$ hollow microspheres show a significant gas response (resistance ratio = 4.97) quickly (~3 s) after exposure to gasoline-evaporated gas at $225^{\circ}C$, but did not show any substantial response to diesel-evaporated gas. This demonstrates that gasoline and diesel fuels can be discriminated using small and cost-effective oxide semiconductor gas sensors.

비정질 탄소막 (a-C:H) 내에 존재하는 수소에 관한 연구

  • 박노길;박형국;손영호;정재인
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.133-133
    • /
    • 1999
  • 비정질 탄소막 제조에 있어서 수소가 포함된 반응성 가스를 사용할 경우 제작된 탄소막 내부에는 수소가 포함되게 되며, 이러한 수소원자들은 막의 특성에 중요한 영향을 주는 것으로 알려져 있다. 따라서, 본 연구에서는 비정질 탄소막(a-C:H) 내부에 존재하는 수소가 탄소막의 특성에 미치는 영향을 알아보고, 막 내부에 포함된 수소의 함량과 공정조건 사이의 함수계를 조사함으로써 수소의 함량을 인위적으로 통제할 수 있는 가능성을 제시하고자 한다. 수소가 포함된 비정질 탄소막은 2.45 GHz의 전자기파를 사용하는 electron cyclotron resonance plasma enhanced chemical vapor deposition (ECR-PECVD) 방법과 DC magnetron sputtering 법을 사용하여 제작하였다. 기판으로는 Si(001) wafer를 사용하였으며, 아세톤과 에탄올을 사용하여 표면의 유기성분을 제거하고, 진공챔버속에서 Ar 플라즈마를 발생시켜 sputter etching 방법으로 표면을 세척하였다. ECR-PECVD 방법에서는 반응가스로 메탄(CH4)과 수소(H2)의 혼합가스를 사용하였으며, 혼합가스의 비는 5~50% 범위내에서 변화를 주었다. 수소가스의 유량은 100SCCM으로 고정하였으며, 마이크로웨이브의 power는 360~900W였고, 기판에 가해준 negative DC bias 전압은 0~-500V이었다. DC magnetron sputtering 방법에서는 반응가스로 아세틸린(C2H2) 가스를 사용하였으며, 플라즈마 발생을 용이하게 하기 위해서 Ar 가스와 혼합하여 사용하였다. Ar 가스의 유량은 10SCCM으로 고정하였으며, 아세틸렌 가스의 유량은 5~20SCCM 범위내에서 주입하였다. 이때, 기판에 가해준 negative DC bias 전압은 0~-100V이었다. 제작된 탄소막의 수소 함량을 조사하기 위하여 Fourier Transform Infrared (FTIR) 분광법과 Elastic Recoil Detection Analysis (EFDA) 법을 사용하였으며, 증착율은 SEM 단면촬영과 a-step을 이용하여 측정하였고, 막의 경도는 Micro-Hardness Testing 법을 사용하여 측정하였다.

  • PDF

Graphene Coated Optical Fiber SPR Biosensor

  • Kim, Jang Ah;Hwang, Taehyun;Dugasani, Sreekantha Reddy;Kulkarni, Atul;Park, Sung Ha;Kim, Taesung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.401-401
    • /
    • 2014
  • In this study, graphene, the most attractive material today, has been applied to the wavelength-modulated surface plasmon resonance (SPR) sensor. The optical fiber sensor technology is the most fascinating topic because of its several benefits. In addition to this, the SPR phenomenon enables the detection of biomaterials to be label-free, highly sensitive, and accurate. Therefore, the optical fiber SPR sensor has powerful advantages to detect biomaterials. Meanwhile, Graphene shows superior mechanical, electrical, and optical characteristics, so that it has tremendous potential to be applied to any applications. Especially, grapheme has tighter confinement plasmon and relatively long propagation distances, so that it can enhance the light-matter interactions (F. H. L. Koppens, et al., Nano Lett., 2011). Accordingly, we coated graphene on the optical fiber probe which we fabricated to compose the wavelength-modulated SPR sensor (Figure 1.). The graphene film was synthesized via thermal chemical vapor deposition (CVD) process. Synthesized graphene was transferred on the core exposed region of fiber optic by lift-off method. Detected analytes were biotinylated double cross-over DNA structure (DXB) and Streptavidin (SA) as the ligand-receptor binding model. The preliminary results showed the SPR signal shifts for the DXB and SA binding rather than the concentration change.

  • PDF

In-Situ Heat Cooling using Thick Graphene and Temperature Monitoring with Single Mask Process

  • Kwack, Kyuhyun;Chun, Kukjin
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.155-158
    • /
    • 2015
  • In this paper, in-situ heat cooling with temperature monitoring is reported to solve thermal issues in electric vehicle (EV) batteries. The device consists of a thick graphene cooler on top of the substrate and a platinum-based resistive temperature sensor with an embedded heater above the graphene. The graphene layer is synthesized by using chemical vapor deposition directly on the Ni layer above the Si substrate. The proposed thick graphene heat cooler does not use transfer technology, which involves many process steps and does not provide a high yield. This method also reduces the mechanical damage of the graphene and uses only one photomask. Using this structure, temperature detection and cooling are conducted simultaneously using one device. The temperature coefficient of resistance (TCR) of a $1{\times}1mm^2$ temperature sensor on 1-$\grave{i}m$-thick graphene is $1.573{\times}10^3ppm/^{\circ}C$. The heat source cools down $7.3^{\circ}C$ from $54.4^{\circ}C$ to $47.1^{\circ}C$.

Voltage waveform detection of discharge breaking process used pulsed-power technique (펄스파워 기술을 이용한 방전파쇄과정의 전압파형 검출)

  • Chung, Y.H.;Yoon, S.H.;Lee, Y.S.;Lee, D.H.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2195-2197
    • /
    • 1999
  • Electric breakdown in the liquid produces a spark channel. The energy input into the channel causes expansion of a vapor gas cavity. If the power of the discharge is high enough, this expansion is fast enough to produce a shock wave which propagates through the liquid to the subject of destruction. We focused our attention on the correlation between electric parameters and the characteristics of the flash caused by point to-point electrode discharge in the water. By varying firing voltage and gap length, we obtained the features of the flash : amplitude, pulse width, and so on. In this paper, We have known that there is a concrete interrelation between underwater firing voltage and photodiode output.

  • PDF