• 제목/요약/키워드: vapor detection

검색결과 136건 처리시간 0.027초

재난 현장에서 이종 센서를 활용한 인명 탐지 기술 개발 (Development of Human Detection Technology with Heterogeneous Sensors for use at Disaster Sites)

  • 서명국;윤복중;신희영;이경준
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권3호
    • /
    • pp.1-8
    • /
    • 2020
  • Recently, a special purpose machine with two manipulators and quadruped crawler system has been developed for rapid life-saving and initial restoration work at disaster sites. This special purpose machine provides the driver with various environmental recognition functions for accurate and rapid task determination. In particular, the human detection technology assists the driver in poor working conditions such as low-light, dust, water vapor, fog, rain, etc. to prevent secondary human accidents when moving and working. In this study, a human detection module is developed to be mounted on a special purpose machine. A thermal sensor and CCD camera were used to detect victims and nearby workers in response to the difficult environmental conditions present at disaster sites. The performance of various AI-based life detection algorithm were verified and then applied to the task of detecting various objects with different postures and exposure conditions. In addition, image visibility improvement technology was applied to further improve the accuracy of human detection.

유체배관 오염 검출장치 개발에 관한 연구 (A Study of the Device Development for the Contamination Detection in the Delivery Line)

  • 정이하;김병한;홍주표
    • 반도체디스플레이기술학회지
    • /
    • 제14권1호
    • /
    • pp.45-49
    • /
    • 2015
  • Process gases with vapor or liquid phase as well as gas phase may experience alteration in itself or be contaminated in the fluid pipe to the process chamber. And thus it result in as particles or defects on the substrates in semiconductor, LCD, LED manufacturing. Purifiers and filters are used for control of contamination. However, none of detection device is available in the delivery line. In this paper, we propose simple device with lighting and sensing in order to predict contamination of the fluid or the tube wall. For some general purpose gases, it showed constant voltage output regardless of the flow rates. But, the smoke and the moisture in the air lowered the figure due to its concentration. Numerical values for several solid and liquid media were obtained. And, the operating temperature tendency was investigated.

유류저장시설로 인한 토양오염 예방대책 (Prevention of Soil Contamination from Underground Storage Facilities)

  • 배우근;홍종철;정진욱;강우재
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.169-173
    • /
    • 1998
  • The practice of the construction and management of the underground petroleum storage facilities in Korea was investigated extensively, and the problems were identified. The advanced technologies in the U.S.A was comparatively studied. Considering the effectiveness of leak prevention and technology applicability, the following measures were suggested. To prevent corrosion of the tank, a clad tank, an interior-lining tank, or a double-wall tank was appropriate and appeared to be most cost effective. For piping, non-metalic material was suggested. To prevent spill, a catchment basin can be effective. For monitoring of leak, construction of more than one of one or combination of an automatic leak-detection device, a vapor-detection system, a ground water-monitoring system, and a double-wall detection system was recommended.

  • PDF

Miniaturized Electronic Nose System Based on a Personal Digital Assistant

  • Kim, Yong-Shin;Yang, Yoon-Seok;Ha, Seung-Chul;Pyo, Hyeon-Bong;Choi, Auck-Choi
    • ETRI Journal
    • /
    • 제27권5호
    • /
    • pp.585-594
    • /
    • 2005
  • A small electronic nose (E-Nose) system has been developed using an 8-channel vapor detection array and personal digital assistant (PDA). The sensor array chip, integrated on a single microheater-embedded polyimide substrate, was made of carbon black-polymer composites with different kinds of polymers and plasticizers. We have successfully classified various volatile organic compounds such as methanol, ethanol, i-propanol, benzene, toluene, n-hexane, n-heptane, and c-hexane with the aid of the sensor array chip, and have evaluated the resolution factors among them, quantitatively. To achieve a PDA-based E-Nose system, we have also elaborated small sensor-interrogating circuits, simple vapor delivery components, and data acquisition and processing programs. As preliminary results show, the miniaturized E-Nose system has demonstrated the identification of essential oils extracted from mint, lavender, and eucalyptus plants.

  • PDF

A new method for measuring ultra-low water vapor permeation for OLED displays

  • Dunkel, Ralf;Bujas, Roko;Klein, Andre;Horndt, Volker;Wrosch, Matt
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.589-593
    • /
    • 2005
  • It is well known that proper encapsulation is crucial for the lifetime of organic light emitting diode (OLED) displays. With the development of increasingly better barrier coatings and perimeter seals, it has now become very desirable to be able to precisely measure the rate of water vapor and oxygen permeation through barrier coatings and perimeter sealing. This paper demonstrates a new permeation measurement method that uses tritium-containing water (HTO) as a tracer material. The theoretical detection limit of this direct method is $2.4{\times}10^{-8}g/(m^2day)$.

  • PDF

Fabrication and Characterization of DBR Porous Silicon Chip for the Detection of Chemical Nerve Agents

  • 정경선
    • 통합자연과학논문집
    • /
    • 제3권4호
    • /
    • pp.237-240
    • /
    • 2010
  • Recently, number of studies for porous silicon have been investigated by many researchers. Multistructured porous silicon (PSi), distributed Bragg reflector (DBR) PSi, has been a topic of interest, because of its unique optical properties. DBR PSi were prepared by an electrochemical etch of $P^{{+}{+}}$-type silicon wafer of resistivity between 0.1 $m{\Omega}cm$ with square wave current density, resulting two different refractive indices. In this work, We have fabricated a simple and portable organic vapor-sensing device based on DBR porous silicon and investigated the optical characteristics of DBR porous silicon. DBR porous silicon have been characterized by FT-IR, Ocean optics 2000 spectrometer. The device used DBR PSi chip has been demonstrated as an excellent gas sensor, showing a great senstivity to a toxic vapor (TEP, DMMP, DEEP) at room temperature.

Evaluation of 1/f Noise Characteristics for Si-Based Infrared Detection Materials

  • Ryu, Ho-Jun;Kwon, Se-In;Cheon, Sang-Hoon;Cho, Seong-Mok;Yang, Woo-Seok;Choi, Chang-Auck
    • ETRI Journal
    • /
    • 제31권6호
    • /
    • pp.703-708
    • /
    • 2009
  • Silicon antimony films are studied as resistors for uncooled microbolometers. We present the fabrication of silicon films and their alloy films using sputtering and plasma-enhanced chemical vapor deposition. The sputtered silicon antimony films show a low 1/f noise level compared to plasma-enhanced chemical vapor deposition (PECVD)-deposited amorphous silicon due to their very fine nanostructure. Material parameter K is controlled using the sputtering conditions to obtain a low 1/f noise. The calculation for specific detectivity assuming similar properties of silicon antimony and PECVD amorphous silicon shows that silicon antimony film demonstrates an outstanding value compared with PECVD Si film.

DBR 다공성 실리콘을 이용한 휘발성 유기화합물의 감지 (Detection of Voletile Organic Compounds by Using DBR Porous Silicon)

  • 박철영
    • 통합자연과학논문집
    • /
    • 제2권4호
    • /
    • pp.275-279
    • /
    • 2009
  • Recently, number of studies for porous silicon (PSi) have been investigated by many researchers. Multistructured porous silicon such as a distributed Bragg reflector (DBR) PSi, has been a topic of interest, because of its unique optical properties. DBR PSi were prepared by using an electrochemical etch of $P{^+}{^+}$-type silicon wafer with resistivity between 0.1 and $10m{\Omega}cm$. The electrochemical etch with square wave current density results in two different refractive indices in the porous layer. In this work, DBR porous silicon chips for a simple and portable organic vapor-sensing device have fabricated. The optical characteristics of DBR PSi have been investigated. DBR porous silicon have been characterized by FT-IR and Ocean optics 2000 spectrometer. The device used DBR PSi chip has been demonstrated as an excellent gas sensor, showing a great senstivity to organic vapor at room temperature.

  • PDF

PERFORMANCE OF COMS SNOW AND SEA ICE DETECTION ALGORITHM

  • Lee, Jung-Rim;Chung, Chu-Yong;Ahn, Myoung-Hwan;Ou, Mi-Lim
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.278-281
    • /
    • 2007
  • The purpose of this study is to develop snow and sea ice detection algorithm in Communication, Ocean and Meteorological Satellite (COMS) meteorological data processing system. Since COMS has only five channels, it is not affordable to use microwave or shortwave infrared data which are effective and generally used for snow detection. In order to estimate snow and sea ice coverage, combinations between available channel data(mostly visible and 3.7 ${\mu}m$) are applied to the algorithm based on threshold method. As a result, the COMS snow and sea ice detection algorithm shows reliable performance compared to MODIS products with channel limitation. Specifically, there is partial underestimation over the complicated vegetation area and overestimation over the area of high level clouds such as cirrus. Some corrections are performed by using water vapor and infrared channels to remove cloud contamination and by applying NDVI to detect more snow pixels for the underestimated area.

  • PDF

영교차율과 가우시안 혼합모델을 이용한 박막증착장비의 세라믹 히터 결함 검출 (Fault Detection for Ceramic Heater in CVD Equipment using Zero-Crossing Rate and Gaussian Mixture Model)

  • 고진석;무향빈;임재열
    • 반도체디스플레이기술학회지
    • /
    • 제12권2호
    • /
    • pp.67-72
    • /
    • 2013
  • Temperature is a critical parameter in yield improvement for wafer manufacturing. In chemical vapor deposition (CVD) equipment, crack defect in ceramic heater leads to yield reduction, however, there is no suitable ceramic heater fault detection system for conventional CVD equipment. This paper proposes a short-time zero-crossing rate based fault detection method for the ceramic heater in CVD equipment. The proposed method measures the output signal ($V_{pp}$) of RF filter and extracts the zero-crossing rate (ZCR) as feature vector. The extracted feature vectors have a discriminant power and Gaussian mixture model (GMM) based fault detection method can detect fault in ceramic heater. Experimental results, carried out by measured signals provided by a CVD equipment manufacturer, indicate that the proposed method detects effectively faults in various process conditions.