• Title/Summary/Keyword: vane method

Search Result 186, Processing Time 0.021 seconds

Evaluation of Acceleration Effect of Ancillary Services on Cavitation and Fatigue of a Water Turbine in Pumped-Storage Plants (부수적 서비스 제공에 따른 양수발전소 수차의 캐비테이션 및 피로에 대한 가속효과 평가)

  • Kim, Jong Sung;Kim, Se Na
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.3
    • /
    • pp.225-232
    • /
    • 2017
  • Several maintenance issues related to cavitation erosion and fatigue cracks in the water turbine subcomponents of pumped-storage plants, such as a runner and a draft tube, have been reported in the past. Generally, the pumped-storage plants provide ancillary services, such as black-start and system stabilization. The ancillary services are responsible for cyclic low opening operation of the guide vanes. It has been empirically established that this low opening operation further damages the water turbine subcomponents. In this study, the acceleration effect of the low opening operation on the cavitation erosion and fatigue of the water turbine is quantitatively assessed through finite element flow analysis, finite element stress analysis, and fatigue analysis. As a result of the assessment, it is identified that the cavitation potential increases and the turbine efficiency decreases with a decrease in the opening of the guide vane. Also, the low opening operation has an insignificant effect on the fatigue even though it increases the maximum stress values at the runner blade roots.

The thickness of the soft soil layer and canal-side road failure: A case study in Phra Nakhon Si Ayutthaya province, Thailand

  • Salisa Chaiyaput;Taweephong Suksawat;Lindung Zalbuin Mase;Motohiro Sugiyama;Jiratchaya Ayawanna
    • Geomechanics and Engineering
    • /
    • v.35 no.5
    • /
    • pp.511-523
    • /
    • 2023
  • Canal-side roads frequently collapse due to an unexpectedly greater soft-clay thickness with a rapid drawdown situation. This causes annually increased repair and reconstruction costs. This paper aims to explore the effect of soft-clay thickness on the failure in the canal-side road in the case study of Phra Nakhon Si Ayutthaya rural road no. 1043 (AY. 1043). Before the actual construction, a field vane shear test was performed to determine the undrained shear strength and identify the thickness of the soft clay at the AY. 1043 area. After establishing the usability of AY. 1043, the resistivity survey method was used to evaluate the thickness of the soft clay layer at the failure zone. The screw driving sounding test was used to evaluate the undrained shear strength for the road structure with a medium-stiff clay layer at the failure zone for applying to the numerical model. This model was simulated to confirm the effect of soft-clay thickness on the failure of the canal-side road. The monitoring and testing results showed the tendency of rapid drawdown failure when the canal-side road was located on > 9 m thick of soft clay with a sensitivity > 4.5. The result indicates that the combination of resistivity survey and field vane shear test can be successfully used to inspect the soft-clay thickness and sensitivity before construction. The preliminary design for preventing failure or improving the stability of the canal-side road should be considered before construction under the critical thickness and sensitivity values of the soft clay.

Aeroelastic stability analysis of a bridge deck with added vanes using a discrete vortex method

  • Taylor, I.;Vezza, M.
    • Wind and Structures
    • /
    • v.5 no.2_3_4
    • /
    • pp.277-290
    • /
    • 2002
  • A two dimensional discrete vortex method (DIVEX) has been developed at the Department of Aerospace Engineering, University of Glasgow, to predict unsteady and incompressible flow fields around closed bodies. The basis of the method is the discretisation of the vorticity field, rather than the velocity field, into a series of vortex particles that are free to move in the flow field that the particles collectively induce. This paper gives a brief description of the numerical implementation of DIVEX and presents the results of calculations on a recent suspension bridge deck section. The results from both the static and flutter analysis of the main deck in isolation are in good agreement with experimental data. A brief study of the effect of flow control vanes on the aeroelastic stability of the bridge is also presented and the results confirm previous analytical and experimental studies. The aeroelastic study is carried out firstly using aerodynamic derivatives extracted from the DIVEX simulations. These results are then assessed further by presenting results from full time-dependent aeroelastic solutions for the original deck and one of the vane cases. In general, the results show good qualitative and quantitative agreement with results from experimental data and demonstrate that DIVEX is a useful design tool in the field of wind engineering.

Dynamic Decoupler Design for EGR and VGT Systems in Passenger Car Diesel Engines (승용디젤엔진 EGR 및 VGT 제어시스템의 동적특성을 고려한 Decoupler 설계 연구)

  • Hong, Seungwoo;Park, Inseok;Sohn, Jeongwon;Sunwoo, Myoungho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.2
    • /
    • pp.182-189
    • /
    • 2014
  • This paper proposes a decoupler design method to reduce interaction between exhaust gas recirculation (EGR) and variable geometry turbocharger (VGT) systems in passenger car diesel engines. The EGR valve and VGT vane are respectively used to control air-to-fuel ratio (AFR) of exhaust gas and intake pressure. A plant model for EGR and VGT systems is defined by a first order transfer function plus time-delay model, and the loop interaction between these systems is analyzed using a relative normalized gain array (RNGA) method. In order to deal with the loop interaction, a design method for simplified decoupler is applied to this study. Feedback control algorithms for AFR and intake pressure are composed of a compensator using PID control method and a prefilter. The proposed decoupler is evaluated through engine experiment, and the results successfully showed that the loop interaction between EGR and VGT systems can be reduced by using the proposed decoupler. Furthermore, it presents stable performance even off from the designed operating point.

On the Analytical Model of Automotive Steering Hoses Containing Tuner and Its Practical Application (튜너 내장 자동차 조향호스의 해석 모델과 실용적 응용)

  • Lee, J.C.;Oh, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • This study presents an analytical model of an automotive steering hose containing tuner(flexible spiral metal tube) to reduce the ripple pressure induced by steering vane pump. The double-wall side branch composed in a steering hose containing tuner was analogically considered as a filter in a conduit. Specialized test equipment was manufactured for the estimation of speed of sound in a conduit and measurement of amplitude ratio between the propagated ripple pressures of inlet and outlet of the steering hose. Experimental data of entire frequency ranges can be obtained through the test once in short time. The results of three points' measurement method and cross-correlation method to estimate the speeds of sound in a hose, tuner, and side branch respectively reveal that cross-correlation method can be used practically. The results of simulation and experiment were so close, especially in the range of engine idling speed, that the proposed analytical model in this study was validated. Sensitivity analyses and experiments show that longer tuner is preferable, and that the positive-positive composition of the steering hoses containing tuner is superior to others to attenuate ripple pressure.

  • PDF

A numerical study on the acoustic characteristics of centrifugal impeller with small added vane (작은 안내 깃이 붙은 원심형 임펠러의 소음 특성에 대한 연구)

  • Jeon, Wan-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.1 s.10
    • /
    • pp.22-29
    • /
    • 2001
  • Centrifugal fans are widely used in industrial practices but the noise generated by these machines causes one of the most serious problems. In general, the centrifugal fan noise is often dominated by tones at BPF(blade passage frequency) and its higher harmonics. This is a consequence of the strong interaction between the flow discharged from the impeller and the cutoff in the easing. However, only a few researches have been carried out on predicting the noise because of the difficulty in obtaining detailed information about the flow field and casing effects on noise radiation. The objective of this study is to develop a prediction method for the unsteady flow field and the acoustic pressure field of a centrifugal fan, and to calculate the effects of small vanes that are attached in original impeller - Splitter impeller. We assume that the impeller rotates with a constant angular velocity and the flow field around the impeller is incompressible and inviscid. So, a discrete vortex method (DVM) is used to model the centrifugal fan and to calculate the flow field. The force of each element on the blade is calculated by the unsteady Bernoulli equation. Lowson's method is used to predict the acoustic source. The splitter impeller changes the acoustic characteristics as well as performance. Two-splitter type impeller and splitter impeller which splitter locates in jet region are good for acoustic characteristics.

  • PDF

Analysis of the Influence of Anti-icing System on the Performance of Combined Cycle Power Plants (가스터빈 결빙방지 시스템이 복합화력발전 시스템의 성능에 미치는 영향)

  • Moon, Seong Won;Kim, Jeong Ho;Kim, Tong Seop
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.6
    • /
    • pp.19-25
    • /
    • 2016
  • Anti-icing is important in gas turbines because ice formation on compressor inlet components, especially inlet guide vane, can cause performance degradation and mechanical damages. In general, the compressor bleeding anti-icing system that supplies hot air extracted from the compressor discharge to the engine intake has been used. However, this scheme causes considerable performance drop of gas turbines. A new method is proposed in this study for the anti-icing in combined cycle power plants(CCPP). It is a heat exchange heating method, which utilizes heat sources from the heat recovery steam generator(HRSG). We selected several options for the heat sources such as steam, hot water and exhaust gas. Performance reductions of the CCPP by the various options as well as the usual compressor bleeding method were comparatively analyzed. The results show that the heat exchange heating system would cause a lower performance decrease than the compressor bleeding anti-icing system. Especially, the option of using low pressure hot water is expected to provide the lowest performance reduction.

Realtime e-Actuator Fault Detection using Online Parameter Identification Method (온라인 식별 및 매개변수 추정을 이용한 실시간 e-Actuator 오류 검출)

  • Park, Jun-Gi;Kim, Tae-Ho;Lee, Heung-Sik;Park, Chansik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.376-382
    • /
    • 2014
  • E-Actuator is an essential part of an eVGT, it receives the command from the main ECU and controls the vane. An e-Actuator failure can cause an abrupt change in engine output and it may induce an accident. Therefore, it is required to detect anomalies in the e-Actuator in real time to prevent accidents. In this paper, an e-Actuator fault detection method using on-line parameter identification is proposed. To implement on-line fault detection algorithm, many constraints are considered. The test input and sampling rate are selected considering the constraints. And new recursive system identification algorithm is proposed which reduces the memory and MCU power dramatically. The relationship between the identified parameters and real elements such as gears, spring and motor are derived. The fault detection method using the relationship is proposed. The experiments with the real broken gears show the effectiveness of the proposed algorithm. It is expected that the real time fault detection is possible and it can improve the safety of eVGT system.

Field instrumentation and settlement prediction of ground treated with straight-line vacuum preloading

  • Lei, Huayang;Feng, Shuangxi;Wang, Lei;Jin, Yawei
    • Geomechanics and Engineering
    • /
    • v.19 no.5
    • /
    • pp.447-462
    • /
    • 2019
  • The vacuum preloading method has been used in many countries for ground improvement and land reclamation works. A sand cushion is required as a horizontal drainage channel for conventional vacuum preloading. In terms of the dredged-fill foundation soil, the treatment effect of the conventional vacuum preloading method is poor, particularly in Tianjin, China, where a shortage of sand exists. To solve this problem, straight-line vacuum preloading without sand is widely adopted in engineering practice to improve the foundation soil. Based on the engineering properties of dredged fill in Lingang City, Tianjin, this paper presents field instrumentation in five sections and analyzes the effect of a prefabricated vertical drain (PVD) layout and a vacuum pumping method on the soft soil ground treatment. Through the arrangement of pore water pressure gauges, settlement marks and vane shear tests, the settlement, pore water pressure and subsoil bearing capacity are analyzed to evaluate the effect of the ground treatment. This study demonstrates that straight-line vacuum preloading without sand can be suitable for areas with a high water content. Furthermore, the consolidation settlement and consolidation degree system is developed based on the grey model to predict the consolidation settlement and consolidation degree under vacuum preloading; the validity of the system is also verified.

Stabilization of Meles Delta soils using cement and lime mixtures

  • Onal, Okan;Sariavci, Cagrihan
    • Geomechanics and Engineering
    • /
    • v.19 no.6
    • /
    • pp.543-554
    • /
    • 2019
  • İzmir Bay reserves high amount of residual alluvial deposits generated by Meles River at its stream mouth. These carried sediments with high water content and low bearing capacity are unsuitable in terms of engineering purposes. In-situ soil stabilization with deep soil mixing method is considered to improve properties of soil in this location. This method is widely used especially over Scandinavia, Japan and North America. Basically, the method covers mixing appropriate binder into the soil to improve soil profile according to the engineering needs. For this purpose, soil samples were initially provided from the site, classification tests were performed and optimum ratios of lime and cement binders were determined. Following, specimens representing the in-situ soil conditions were prepared and cured to be able to determine their engineering properties. Unconfined compression tests and vane shear tests were applied to evaluate the stabilization performance of binders on samples with different curing periods. Scanning electron microscope was used to observe time-dependent bonding progress of binders in order to validate the results. Utilization of 4% lime and 4% cement mixture for the long-term performance and 8% lime and 8% cement mixture for short term performance were suggested for the stabilization of Meles Delta soils. Development of CSH and CAH in a gel form as well as CSH crystals were clearly observed on SEM images of treated specimens.