From 1958 to October 1977, 294 cases of acquired heart disease were operated. There were 68 cases of pericardium, 3 trauma, 2 foreign body, one cardiac thrombus, 3 atrial myxoma, 2 left atrial and 1 right atrial, 2 Budd-Chiari syndrome, and 214 valvular heart disease. Out of 214 cases of valve operation 73 valves were replaced in 64 patients. Male to female ratio was 1.46: 1. The youngest age was 14 years in male and 18 in female. The oldest was 54 years in male and 52 in female. Fifty-five cases of single valve were replaced, consisting of 47 mitral and 8 aortic valves. There were 9 double valve replacement cases which consist of 7 mitral and aortic and 2 mitral .and tricuspid valves. Six varieties of prosthetic valves, 3 ball and 3 disc types and 3 kinds of xenograft tissue valves were utilized. Beall, BjSrk-Shiley and Starr-Edwards prosthetic valves and Hancock valves were used mainly. For single valve 34. 5% and for double valve replacement 44% mortality were noted. There were 23 operative deaths out of 64 patients, over all mortality rate of 36.9%. Mortality for mitral valve replacement was 29.5%. But in recent 12 consecutive cases one death occurred, showing 8.3% mortality. In earlier days thrombocyte anti-adhesive drug dipyramidole-persantin-aspirin and/or SP 54 were adminstered. But in recent cases after heparinization, coumadin and Persantin were prescribed routinely.
Proceedings of the Korea Contents Association Conference
/
2008.05a
/
pp.771-775
/
2008
Concerns related to protecting, identifying, and isolating of subsystems of a water distribution network have led to the realization of the increased importance of valves in the system. The most important purpose of valves in water distribution systems is to isolate subsystems due to breakage, maintenance activities, or contamination. A subsystem called segment is isolated by the closure of adjacent valves and an efficient algorithm should identify the adjacent valves to minimize the pipe failure impact. In this paper, an algorithm to identify adjacent valves to be closed to isolate a subsystem from the remainder of a network in case of a pipe failure is presented. An application to the water distribution system in Ottawa, Canada demonstrates the developed algorithm efficiently locates the adjacent valves for the isolation of a broken pipe.
Journal of the Korea Academia-Industrial cooperation Society
/
v.21
no.1
/
pp.387-392
/
2020
This paper proposes a flow-rate control system for industrial valves. Industrial valves are used in piping systems to control the flow rate and pressure. In general, valves used in pipelines are classified into globe valves, butterfly valves, and ball valves according to the shape. Motor, hydraulic, and pneumatic systems are used for operating valves. The flow meter should measure the flow rate when configuring the flow-rate control system. On the other hand, because the flow rate of the valve can be expressed by flow coefficient, a control scheme is proposed using the pressure deviation, which measures at the front and rear of the valve. The transfer function for the valve, according to the control input, was estimated using the signal compression method. Based on the induced transfer function, the disturbance observer was designed to improve the command following the performance of the valve stem. The performance of the proposed control method is compared with the flow-rate control result using the flow meter used.
The Carpentier-Edwards porcine xenograft valve was used in 21 patients at Seoul National University Hospital during the period between 1977 and 1979. Twenty-four Carpentier-Edwards valves were implanted along with 2 others. Three patients died within 30 days of operation, an operative mortality rate of 14.3%. Eighteen early survivors were followed up for a total 67.5 patient-years [mean, 45.0$\pm$32.0 months]. There were 2 late deaths with a linealized late mortality rate of 2.96%/patient-year; one died from cerebral bleeding [1.48% bleeding/patient-year] and the other from prosthetic valve endocarditis [1, 48% endocarditis/patient-year]. There was no case of thromboembolism. Two patients developed mitral regurgitation [2.96% failure/patient-year]. Symptomatic improvement was excellent. The actuarial survival rate and the probability of freedom from overall valve failure were 75.3$\pm$9.6% and 80.7$\pm$12.9% at 9 years after surgery respectively. During the period from October, 1968, through June, 1985, 1, 190 substitute heart valves were used in a total of 967 patients at Seoul National University Hospital; of which, 90.9% were either porcine aortic or bovine pericardial xenograft valves. For the evaluation of the xenograft tissue valves, the consecutive patients with lonescu-Shiley valve in the mitral, aortic and both positions, Angell-Shiley valve and Carpentier-Edwards valve were recently studied on the clinical ground. They were 531 patients, and 643 xenograft valves were used. The operative mortality rate was 6.97% and a linealized late mortality rate 2.94%/patient-year. A total of 490 early survivors were followed up for 917.6 patient-years [mean, 22.5 months], and 70% of patients completed the follow-up. The linealized incidences of complications were: 2.29% emboli/patient-year, 1.98% bleeding/patient-year, 1.20% endocarditis/patient-year, and 3.49% failure/patient-year. These clinical resutls are fully comparable with those in the major reports. The durability of the glutaraldehydepreserved xenograft heart valves remains as a great concern and a continuing debate, expecially for the group of patients in the pediatric age. The need of more durable material for the improved tissue valves was also discussed.
During 12 years period from 1974 to 1985, 76 valve replacement procedures were performed at Seoul National University Hospital in 67 pediatric patients aging up to 15 years [mean 12.3 years] and it was 7.3% of total valve replacement procedures in same period. Sixty seven patients were composed of 44 males and 23 females. Of the 67 patients, 43 patients had acquired valve lesions and 24 patients congenital valve lesions. Sixty cases received single valve replacement, 7 cases double or triple valve replacement and 9 cases redo-valve replacement. Sixty seven patients received 84 valves [65 bioprosthetic valves and 19 prosthetic valves by] 76 operations, Sixty three of 65 bioprosthetic valves had been replaced before 1983 and 15 of 19 prosthetic valves in recent 2 years. Eleven patients [14.6%] died within one month post-operatively and 8 patients [10.5%] during the follow-up period with the overall mortality rate of 25.1%. There were early post-operative complication of 23 cases [30.3%] and late post-operative complication of 27 cases [35.3%] with the total complication rate of 65.8%. In 58 patients received bioprosthetic valves, there were 14 cases of restenosis of replaced valves. Of the 14 cases of bioprosthetic valve restenosis, 8 cases received redo-valve replacement procedures without mortality in 1 5/12-5 years after initial operation but 4 cases died without reoperation and 2 cases lost during follow-up. The overall mortality and complication rate were still high but they markedly decreased during recent 2 years. So, in spite of its containing many problems, valve replacement in children is becoming safe and useful procedure in whom valve reconstructive procedures are impossible.
Journal of the Korea Academia-Industrial cooperation Society
/
v.13
no.11
/
pp.4937-4943
/
2012
Butterfly valves have been used to control the flow rate of various fluids in many industries because it have unique manageability compare to other valves. The flow rate passing through the butterfly valves can be controlled according to the coefficient of capacity calculated by disk angle change. In this study, flow analysis by 3D modeling was performed to derive the coefficient of capacity to evaluate and improve newly developed butterfly valves. Also, required measurement system was established to verify the performance of the valves, and to compare with the calculated results.
Journal of the Korean Society of Manufacturing Process Engineers
/
v.15
no.1
/
pp.129-135
/
2016
Various type of valves are manufactured for different industrial uses. Among them, check valves are used to allow fluid to flow in one direction but not in the opposite direction. There are many different types of check valves, but Y-shaped check valves are widely used these days. Not many studies have been carried out on Y-shaped check valves and the flow coefficients obtained through numerical analysis have the problem of low reliability. In order to solve this problem, this study performed flow analysis, flow-structure coupled analysis, and flow coefficient measurement experimentally, and through these analyses derived and verified the flow coefficients and assessed the structural safety based on numerical analysis.
Transactions of the Korean Society of Mechanical Engineers A
/
v.33
no.6
/
pp.568-572
/
2009
We present a ternary microfluidic multiplexer unit, capable to address three flow channels using a pair of control lines with two different threshold pressure valves. The previous binary multiplexer unit addresses only two flow channels using a pair of control line with identical threshold pressure valves, thus addressing $2^{n/2}$ flow channels using n control lines. The present ternary multiplexer addressing three flow channels using a pair of control lines, however, is capable to address $3^{n/2}$ flow channels using n control lines with two different threshold pressure valves. In the experimental study, we characterized the threshold pressure and the response time of the valves used in the ternary multiplexer. From the experimental observation, we also verified that the present ternary multiplexer unit could be operated by two equivalent valve operating conditions: the different static pressures and dynamic pressures at different duty ratio. And then, $3{\times}3$ well array stacking ternary multiplexers in serial is addressed in cross and plus patterns, thus demonstrating the individual flow channel addressing capability of the ternary multiplexer. Thus, the present ternary multiplexer reduces the number of control lines for addressing flow channels, achieving the high well control efficiency required for simple and compact microfluidic systems.
The check valves are mechanical valves that permit fluids to flow in only one direction, preventing flow from reversing. It is classified as one way directional valves. There are various types of check valves that used in a marine application. A lift type check valve uses the disc to open and close the passage of fluid. The disc lift up from seat as pressure below the disc increases, while drop in pressure on the inlet side or a build up of pressure on the outlet side causes the valve to close. An important concept in check valves is the cracking pressure which is the minimum upstream pressure at which the valve will operate. On the other hand, optimization is a process of finding the best set of parameters to reach a goal while not violating certain constraints. The AMESim software provides NLPQL(Nonlinear Programming by Quadratic Lagrangian) and genetic algorithm(GA) for optimization. NLPQL is the implementation of a SQP(sequential quadratic programming) algorithm. SQP is a standard method, based on the use of a gradient of objective functions and constraints to solve a non-linear optimization problem. A characteristic of the NLPQL is that it stops as soon as it finds a local minimum. Thus, the simulation results may be highly dependent on the starting point which user give to the algorithm. In this paper, we carried out optimization design of the check valve with NLPQL algorithm.
Kim, S.H.;Chang, B.C.;Tack, G.;Huh, J.M.;Kim, N.H.;Kang, M.S.;Cho, B.K.
Proceedings of the KOSOMBE Conference
/
v.1994
no.05
/
pp.105-108
/
1994
A comparative study was made of the valvular sounds produced by normal prosthetic valves with thrombosed prosthetic valves. Comparisons of the closing sound were made for the power frequency spectra associated with individual valves. We used periodogram approach to obtain the spectral characteristics of the valve. Spectral analysis system was tested in mock circulatory system by comparing normal valves with those produced by the same valves but having simulated thrombosis at the hinge of the valve. The heart sounds was recorded from two patients having normal mechanical valve and thrombosed mechanical valve. The estimated spectrum of the thrombosed mechanical valve displayed lower apparent peak frequency than that of the normal valve. The results showed that frequency spectra gave information pertinent to the valve malfunction. Sound spectral analysis is simple and alternative diagnostic tool for early detection of prosthetic valve mal function.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.