• 제목/요약/키워드: valves

검색결과 1,594건 처리시간 0.028초

미소유체 이송용 압전펌프를 위한 시트형 체크밸브의 동특성에 관한 연구 (A study on dynamic characteristics of sheet type check valves in PZT pump for small liquid delivery)

  • 함영복;노종호;신동식;박중호;김한석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1087-1090
    • /
    • 2005
  • In precision machinery systems for medical and chemical applications, micropumps with a low pulsation have been demanded and investigated for accurate delivery of a small amount of liquid. This study proposes sheet type check valves instead of ball type check valves for PZT pumps and performs some tests on dynamics characteristics of check valves having different design parameter with variable frequency. The selected materials of check valves is NBR, PP film, Polyimide and Stainless steel(SUS304). In the experiment, dynamic characteristics of stainless steel thin plate have better performance than others.

  • PDF

Anti-Cavitation Trim을 갖는 고차압 제어밸브의 유동특성에 관한 수치해석 (Numerical Analysis on Flow Characteristics of High Pressure Drop Control Valves with Anti-Cavitation Trim)

  • 안영준;김병진;신병록
    • 한국유체기계학회 논문집
    • /
    • 제10권4호
    • /
    • pp.61-70
    • /
    • 2007
  • Numerical analysis of three dimensional incompressible turbulent flows in LNG marine high pressure drop control valves was carried out by using the CFD-ACE from ESI-Group. In this study, flow characteristics of control valves with complex flow fields including cavitation effect were investigated. Simulation was performed on five models of control valve that had different orifice diameters of anti-trim and the size of valve. Comparing newly designed control valves for controling the occurrence of cavitation with the conventional valve, new valves showed a improved flow pattern with almost no cavitation.

개폐식 밸브를 사용한 공기압 서보 시스템의 효율적 밸브 개폐 방법에 관한 연구 (Study on the Effective Operating Method of on-off Valves for a Pneumatic Servo System)

  • 황웅태;최서호;이정오
    • 한국정밀공학회지
    • /
    • 제15권1호
    • /
    • pp.109-116
    • /
    • 1998
  • This paper is concerned with effective operating method of pneumatic on-off valves for improving position control accuracy, valve life-time and position settling time using modified pulse width modulation with dead-zone (MPWMD). The pneumatic system using on-off valves has advantage of simple construction and low cost compared with a system with servo-valves. The performance of the proposed control method is investigated experimentally for the position control of a pneumatic cylinder using on-off valves. Experimental results show that the proposed algorithm for valve operation can be used to obtain fast and accurate position control compared to the conventional PWMD algorithm. It is also shown that the use of the proposed MPWMD algorithm for the position control significantly reduces the number of valve switching and noise.

  • PDF

고속전자밸브를 사용한 전기유압서보시스템의 위치제어에 관한 연구 (A Study on Position Control of an Electro-Hydraulic Servo System Using High Speed On-Off Valves)

  • 허준영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권3호
    • /
    • pp.369-378
    • /
    • 1999
  • This paper presents position control of an electro-hydraulic servo system whoch is operated by four 2-2way high speed on-off valves with either PWM PID control method or sliding mode control method, The advantages of using high speed on-off valves instead of electo-hydraulic servo valves or electro-hydraulic proportional valves are low price robustness for oil contamination and direct control without a D/A converter. The system consists of load cylinder inertia car potentiometer and external load cylinder. The experiments were carried out under several conditions and the results were compared. As a result the sliding mode method has shown good control performance and the robust and stable positioning of the elector-hydraulic servo system can be achieved accurately.

  • PDF

고온.고압용 3-way 볼밸브의 특성해석 (A Characteristic Analysis of High Pressure and High Temperature 3-way Ball Valve)

  • 이준호
    • 한국기계가공학회지
    • /
    • 제11권4호
    • /
    • pp.180-184
    • /
    • 2012
  • 3-way ball valves have been mostly used for high temperature/high pressure valves using in petrochemical carriers and oil tankers, which requires high quality products with confidentiality and durability. As a larger disaster may be generated by leakage of oil or gas from valves, thus the present research applied a numerical analysis method with thermal-structural coupled field analysis and the performance test. The Max stress by parts was confirmed through thermal-structural coupled field analysis and develop the 3-way ball valve design, which is safe on operating condition. And its performance was verified by carrying out pressure test, leakage test and durability test for the manufactured 3-way ball valves with satisfying it's regulations.

래크바형 수문권양기에 적용된 정유압장치의 컴퓨터 시뮬레이션에 의한 작동특성 연구 (Computer Simulation Study of the Hydrostatic Transmission Applied to the Rack-Bar Type Sluice Gate)

  • 이성래
    • 유공압시스템학회논문집
    • /
    • 제6권2호
    • /
    • pp.14-21
    • /
    • 2009
  • The typical hydraulic hoisting system of the rack-bar type sluice gate is composed of a hydraulic supply unit using an uni-directional pump, a direction control valve, a hydraulic motor, a counter balance valve, and flow control valves. Here, the hydrostatic transmission is applied to the hoisting system of rack-bar type sluice gate to simplify the operation of gate such that the upward and downward direction of gate is simply controlled by the direction of pump rotation. The new hydraulic hoisting system is composed of a bi-directional pump, a hydraulic motor, two counter balance valves, two check valves, two pilot-operated check valves, two relief valves and a shuttle valve. The characteristics of a suggested system are analyzed by computer simulations.

  • PDF

Numerical Investigation of Hemodynamics in a Bileaflet Mechanical Heart Valve using an Implicit FSI Based on the ALE Approach

  • Hong, Tae-Hyub;Choi, Choeng-Ryul;Kim, Chang-Nyung
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2410-2414
    • /
    • 2008
  • Human heart valves diseased by congenital heart defects, rheumatic fever, bacterial infection, cancer may cause stenosis or insufficiency in the valves. Treatment may be with medication but often involves valve repair or replacement (insertion of an artificial heart valve). Bileaflet mechanical heart valves (BMHVs) are widely implanted to replace the diseased heart valves, but still suffer from complications such as hemolysis, platelet activation, tissue overgrowth and device failure. These complications are closely related to both flow characteristics through the valves and leaflet dynamics. In this study, the physiological flow interacting with the moving leaflets in a bileaflet mechanical heart valve (BMHV) is simulated with a strongly coupled implicit fluid-structure interaction (FSI) method which is newly organized based on the Arbitrary-Lagrangian-Eulerian (ALE) approach and the dynamic mesh method (remeshing) in FLUENT. The simulated results are in good agreement with previous experimental studies. This study shows the applicability of the present FSI model to the complicated physics interacting between fluid flow and moving boundary.

  • PDF

밀폐형 왕복동압축기의 리드밸브 동특성에 관한 연구 (A Study on the Dynamic Characteristics of Reed Valves in Hermetic Reciprocating Compressors)

  • 김정우;김현진;박희용
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.163-174
    • /
    • 1992
  • This paper presents numerical and experimental methods of investigating dynamic characterisics of reed valves of hermetic reciprocating compressors. For the natural frequency, two different techniques have been tried : microphone method and strain gage method. In the microphone method, acoustic pressure signals from excited valves have been analyzed, while signals of tiny strain gauge attached on the reed valves have been utilized in the strain gage method. The empirically determined natural frequencies have been compared to the ones calculated by finite element method. Reasonably good agreements between the experimental and numerical results have been found, implying that the natural frequencies of reed valves could be obtained by FFM alone with enough accuracy.

  • PDF

온수분배기용 유량제어밸브의 개발 (Development of Flow Control Valves for Hot Water Distribution Manifolds)

  • 권우철;윤준용;유선학
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).

심장판막치환술의 임상적 고찰 (Coinical Evaluation of Cardiac Valve Replacement)

  • 강창희
    • Journal of Chest Surgery
    • /
    • 제27권6호
    • /
    • pp.444-450
    • /
    • 1994
  • From June 1984 to February 1994, cardiac valve replacement was performed in 108 patients. The distribution of patients was ranged from 13 to 64 year-old age[mean 39.48 1.24] and 51 patients were male, 57 patients were female [male:female=1:1.1]. 64 patients had mitral valve replacement, 27 patients underwent aortic valve replacement and 17 patients were performed double[mitral & aortic] valve replacement. Total 125 artificial cardiac valves were used, mechanical valves were 51 valves and tissue valves were 74 valves. The duration of follow-up was 473.41 patient-year[mean 4.79 3.29 patient-year] and the information of follow-up was available for 99 patients[92%]. The actuarial survival rates including the operative mortality was 89.5% & 88.3 at postoperative fourth & ninth year. The probability of freedom from overall valve failure, thromboembolism and bacterial endocarditis were 77.5%, 89.2% and 95.6% at ninth year after cardiac valve replacement.

  • PDF