• 제목/요약/키워드: valves

검색결과 1,599건 처리시간 0.039초

PC기반 비례방향제어밸브를 이용한 압력제어에 관한 연구 (A study on PC based pressure control using a proportional directional control valve)

  • 전세형;여화동;홍석철;김성동
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.462-466
    • /
    • 1997
  • Proportional directional control valves (PDCVl adjust the amount of flow as well as flow direction in response to an electrical signal. This valves includes direct operated valves with or without spool position feedback. This paper investigates if it is possible to control pressure of fluids by means of the PDCV. A pressure signal is feed back to the Proportional-Integral (PI) controller, which is based upon a personal computer (PC). The PI control algorithm is implemented in a graphical programming language of LabVIEW. The results of experiments show the PDCV can be used a multi function valve of pressure control as well as direction control.

  • PDF

음향방출 계측에 의한 터빈 제어밸브 내부누설 평가연구 (Study on Evaluation of Internal Leak of Turbine Control Valve in Power Plant Using Acoustic Emission Signal Measurement)

  • 이상국
    • 동력기계공학회지
    • /
    • 제12권5호
    • /
    • pp.65-70
    • /
    • 2008
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the turbine major valves relating to safety for turbine operating and prevention of turbine trouble at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized electro-hydraulic control oil flowed through turbine electro-hydraulic controller oil check valve and turbine power/trip fluid solenoid valve in the condition of actual turbine operating. The acoustic emission method was applied to the valves at the site, and the background noise was measured far the abnormal plant condition. To judge for the leak existence ell the object valves, voltage analysis and frequency analysis of acoustic signal emitted from infernal leak in the valve operating condition are performed. It was conformed that acoustic emission method could monitor for valve internal leak to high sensitivity.

  • PDF

솔레노이드 밸브가 유압위치제어 시스템의 응답특성에 미치는 영향 (Effect of solenoid valves on the response characteristics of a hydraulic position-control system)

  • 장효환;안병홍
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.364-369
    • /
    • 1987
  • It has recently shown that a solenoid valve can be utilized in a hydraulic position-control system by discontinuous control methods. The objective of this study is to investigate the effects of solenoid valves on the response characteristics of a hydraulic position-control system by applying two kinds of discontinued control methods i.e., Simple On-Off (SOF) and Pusating On-Off(POF) controls. Three types of solenoid valves i.e. low-frequency, closed-center type (LF/C), high-frequency, closed-center type (HF/C), low-frequency, tandem-center type(LF/T) were used in this study. Effects of loading conditions and control parameters on the response characteristics were experimentally examined and compared each other. Pressure transients within the actuator were also studied.

  • PDF

고속전자밸브로 제어되는 전기.유압 서보시스템의 특성 개선에 관한 연구 (A Study on the Characteristics Improvement of Electro-Hydraulic Servo System Controlled by High Speed Solenoid Valve)

  • 박성환;이진걸
    • 제어로봇시스템학회논문지
    • /
    • 제7권4호
    • /
    • pp.288-294
    • /
    • 2001
  • In this study, a new PWM method considering the actuation delay of high speed solenoid valves is proposed to improve the response characteristics of electro hydraulic servo systems controlled by high speed solenoid valves. In addition, the decision method for the system gain, the basic period of PWM, and the sampling time is proposed, Since the conventional system controlled by high speed solenoid valves is too slow to apply this method, a high speed driving circuit(Quick-Drive) which enables rapid switching of the high speed solenoid valve at a high speed sampling mode is applied to realize this method. The experimental result shows that it is possible to achieve precision and quiet control without occurrence of limit cycle and wide range dead band.

  • PDF

스파이럴 그루브가 가공된 스풀밸브의 윤활 특성 연구 (A Study on the Lubrication Characteristics of Spool Valve with Spiral Groove)

  • 홍성호;손상익;김경웅
    • Tribology and Lubricants
    • /
    • 제28권6호
    • /
    • pp.303-314
    • /
    • 2012
  • In this research, spool valves with spiral grooves are suggested and their lubrication characteristics are investigated by numerical analysis. The three-dimensional flow field is obtained by solving the Navier-Stokes equations in dimensionless form, so that the performance variables such as lateral force, friction force and volume flow rate are determined. Also, the lubrication characteristics of spool valves with spiral grooves are compared with those with typical grooves under variable working conditions. It is shown that spool valves with spiral grooves can get better performance in aspect of mitigation of uneven pressure distribution surrounding spool. Moreover, it is found that the minimum distance between spool edges and grooves, the type of spiral groove, and the groove angle have noticeable effect on the lubrication characteristics.

인공심방판막실패에 대한 임상적 고찰 (Reoperation for prosthetic valve failure -clinical analysis of 15 cases-)

  • 권오춘
    • Journal of Chest Surgery
    • /
    • 제19권4호
    • /
    • pp.584-594
    • /
    • 1986
  • Despite the multivariate improvements in tissue treatment, material, and design of prosthetic heart valves in recent years, numerous complications that may lead to valve dysfunction remain a constant threat after valve replacement. Most common indications for prosthetic valve failure are primary valve failure, infective endocarditis, paravalvular leakage, and thromboembolism. From 1977 to 1986, 15 patients underwent reoperation for prosthetic valve failure in 278 cases of valve surgery. The etiology of prosthetic valve failure were primary valve failure in 12 patients [80 %], infective endocarditis in 2 patients [13.3 %], and a paravalvular leakage [6.7 %]. The average durations of implantation were 45.5 months; 53.9 months in primary valve failure, 16 months in infective endocarditis, and 4 months in paravalvular leakage. The rate of valve failure was high under age of 30 [11/15]. Calcifications and collagen disruption of prosthesis were main cause of primary valve failure in macro- & micropathology. Prosthesis used in reoperation were 5 tissue valves and 10 mechanical valves. Operative mortality were 13.3 % [2/15], due to intractable endocarditis and ventricular arrhythmia.

  • PDF

급수기구 발생음의 실험실 측정방법 제2부 : 수도꼭지와 혼합꼭지의 부착방법 및 작동조건 (Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 2: Mounting and operating conditions for draw-off taps and mixing valves)

  • 정갑철;양관섭;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.861-863
    • /
    • 2003
  • The method of measurement for laboratory tests on noise emission from appliances and equipment used in water supply installations is specified in ISO 3822-1. This part of standard gives detailed descriptions for mounting and operating draw-off taps and mixing valves in such laboratory test. Draw-off taps and mixing valves are the most common kind of appliance used in water supply installations.

  • PDF

인공심장판막의 재치환술 (Redo Operation of the Artifitial Heart Valves)

  • 조상록
    • Journal of Chest Surgery
    • /
    • 제25권2호
    • /
    • pp.158-166
    • /
    • 1992
  • From 1985 to 1990, a total of 160 new valves were implanted for 125 adult patients to whom prosthetic valve replacement had been performed [One patient had consecutive 2 reoperations]. Following data are the results from the follow-up study from January 1985 to February 1991. Mean age of the patients was 37.9$\pm$12.1 years. Mean follow-up period was 25.8$\pm$18.8 months. In bioprosthesis, mean interval between the previous operation and reoperation was 85.6$\pm$36.4 months in aortic valve, and 87.3$\pm$30.0 months in mitral valve. The causes of reoperation were prosthetic valve failure[103 patients, 81.7%], prosthetic valve endocarditis[17 patients, 13.5%], periprosthetic leakage[5 patients, 4.0%], and aneurysm of ascending aorta[1 patient, 0.8%]. Fourteen patients[11.1%] died in hospital; 5 in 22 replacement of aortic valve[22.7%], 6 in 73 rereplacement of mitral valve[8.2%], and 3 in 31 replacement of multiple valves [9.7%] Except for 3 intraoperative deaths, postoperative, major and minor complications occurred in 39 patients[31.0%]. And the actuarial 5-year survival rate of operative survivors was 95.5$\pm$8.6%.

  • PDF

소아 및 청소년기에 있어서의 판막대치이식술에 관한 연구 (Cardiac valve replacement in children and adolescents)

  • 박이태;이영균
    • Journal of Chest Surgery
    • /
    • 제16권4호
    • /
    • pp.444-451
    • /
    • 1983
  • Valve replacement in children and adolescents, aging below 20 years [Mean 15 years 4 months], has been done at Seoul National University Hospital from March 1977 to September 1982 . Seventy-Seven patients have received 91 artificial valves 4 prosthetic valves and 87 bioprosthetic valves. 63 patients had acquired valve lesions and 14 patients had congenital valve lesions. Among the patients with acquired valve lesion, 32 patients had the history of rheumatic fever. Seventy-five patients survived operation: 12 patients [ 15.6%] died within one month postoperatively and 3 patients [3.9%] during the follow-up period with the overall mortality rate of 19.5% Thromboembolic complication occurred in 3 patients with 2 deaths: 3.9% embolic rate or 3.74% emboli per patient-year. One patient who had been on coumadin anticoagulation died from cerebral hemorrhage. Actuarial survival rate was 77.6% at 1 years after surgery, after then there were no death.

  • PDF

모터구동 게이트밸브 열림행정시 차압 작용에 의한 부하율 연구 (Study on the Rate-of-Loading by the Differential Pressure of Motor Operated Gate Valves in Opening Stroke)

  • 김대웅;박성근;정래혁;이도환;홍승열
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.166-171
    • /
    • 2004
  • The Rate-of-Loading(ROL) effect of motor operated gate valves causes a decrease in the thrust delivered at a specific torque by the actuator under dynamic flow ${\Delta}$P conditions as compared to the no-flow, static conditions. This effect needs to be studied for the quantitative evaluation of motor operated gate valve operability. This study is performed to verify the validity for the application of ROL in the evaluation of operability of motor operated gate valves for the opening stroke. The ROL is assessed on the basis of in-situ test data for the opening and closing strokes. The results show that the distribution of the ROL for the operling sake has a tendency to the negative value when DP is higher than 150psid.

  • PDF