• Title/Summary/Keyword: valves

Search Result 1,599, Processing Time 0.03 seconds

Open Heart Surgery 600 Cases for 5 Years (5년간 개심술 600예에 관한 검토)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.404-420
    • /
    • 1991
  • Surgical treatment of congenital and acquired heart disease preceded the development of accurate techniques for diagnosis, heart lung machine and cardiopulmonary bypass, intraoperative myocardial protection, operative techniques and cardiac anesthesia. For 5 years from Sep. 1985 to Sep. 1990, six hundred cases of open heart surgeries [OHS] were performed in the department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, College of Medicine, Inje University. The results were summarized as follows. 1. The annual number of OHS[cases per year] was above 100 since 1987, and the increasing rate of cases was 23.5% per year since 1986. 2. Among the total 600 cases, there were 470 cases of congenital heart diseases and 130 cases of acquired. Age range of the congenital patients was 8 months to 44 years with the mean age of 10 years, and acquired patients was 16 to 56 years with the mean age of 36 years. 3. Among the 470 congenital anomalies, there were 429 cases of acyanotic and 41 cyanotic patients. Totally, VSD was 286 cases[60.6%], ASD 103 cases[21.9%], TOF 35 cases [7.4%], PS 20 cases [4.1%], ECD 12 cases [2.0%], Ebstein`s anomaly 3 cases [0.6%], Valsalva sinus rupture 3 cases [0.6%] and others. The appropriate one stage radical operations were applied to the all congenital cases with the result of 2.6% immediate postoperative hospital mortality rate. 4. Among the 130 acquired cases, there were 122 cases of valvular heart diseases, 6 of heart tumors [5 myxoma, one malignant histiocytoma], one of LA thrombus and one of annuloaortic ectasia. Cardiac tumors and LA thrombus were removed through the atrial septal approach. Bentall procedure was adopted to the annuloaortic ectasia case. AVR, MVR and TVA [DeVega procedure] were applied to 120 valve diseases, and there were also one of OMC and one of MVA[Jerome-Kay procedure]. 5. Among the 120 valve replacement cases, there were 87 of single valve replacement cases [AVR: 8, MVR: 79], 11 of double valve replacement [AVR+MVR: 11], 12 of MVR+TVR and 10 of MVR+AVR+TVA. The total number of implanted prosthetic valves were 141. In MVR, 45 of St. Jude Medical valves, 63 of Carpentier-Edward valves and 4 of Ionescu-Shiley valves were used. In AVR, 18 of St. Jude Medical valves and 11 of Carpentier-Edward valves were used. in MVR, 29mm and 31mm sized valves were used mostly and In AVR, 23mm sized valves were used mostly. 6. Postoperatively many kinds of complications were occurred. Among them, wound problems [30 cases], low output syndrome [29 cases], arrhythmia [20 cases], pleural effusion and pneumothorax [13 cases] were occurred frequently. The postoperative immediate hospital mortality was 3.0% in total [congenital 2.6%, acquired 4.6%].

  • PDF

Thrombocytopenia after Aortic Valve Replacement Using Sutureless Valves

  • Mil Hoo Kim;Soojin Lee;Juhyun Lee;Seohee Joo;You Kyeong Park;Kang Min Kim;Joon Chul Jung;Hyoung Woo Chang;Jae Hang Lee;Dong Jung Kim;Jun Sung Kim;Kay-Hyun Park;Cheong Lim
    • Journal of Chest Surgery
    • /
    • v.57 no.4
    • /
    • pp.371-379
    • /
    • 2024
  • Background: Sutureless valves are widely used in aortic valve replacement surgery, with Perceval valves and Intuity valves being particularly prominent. However, concerns have been raised about postoperative thrombocytopenia with Perceval valves (Corcym, UK). We conducted a comparative analysis with the Intuity valve (Edwards Lifesciences, USA), and assessed how thrombocytopenia affected patient and transfusion outcomes. Methods: Among 595 patients who underwent aortic valve replacement from June 2016 to March 2023, sutureless valves were used in 53 (Perceval: n=23; Intuity: n=30). Platelet counts were monitored during hospitalization and outpatient visits. Daily platelet count changes were compared between groups, and the results from patients who underwent procedures using Carpentier Edwards Perimount Magna valves were used as a reference group. Results: Compared to the Intuity group, the Perceval group showed a significantly higher amount of platelet transfusion (5.48±1.64 packs vs. 0.60±0.44 packs, p=0.008). During the postoperative period, severe thrombocytopenia (<50,000/μL) was significantly more prevalent in the Perceval group (56.5%, n=13) than in the Intuity group (6.7%, n=2). After initial postoperative depletion, daily platelet counts increased, with significant differences observed in the extent of improvement between the Perceval and Intuity groups (p<0.001). However, there was no significant difference in early mortality or the incidence of neurological complications between the 2 groups. Conclusion: The severity of postoperative thrombocytopenia differed significantly between the Perceval and Intuity valves. The Perceval group showed a significantly higher prevalence of severe thrombocytopenia and higher platelet transfusion volumes. However, thrombocytopenia gradually recovered during the postoperative period in both groups, and the early outcomes were similar in both groups.

Biaxial Strain Analysis of Various Fixation Models in Porcine Aortic and Pulmonary Valves (돼지 대동맥 판막과 폐동맥 판막의 고정 방법에 따른 양방향 압력-신장도의 비교분석)

  • Cho, Sung-Kyu;Kim, Yong-Jin;Kim, Soo-Hwan;Choi, Seung-Hwa
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.566-575
    • /
    • 2009
  • Background: The function of a bioprosthetic heart valve is determined largely by the material properties of the valve cusps. The uniaxial tensile test has been studied extensively. This type of testing, however, does not replicate the natural biaxial loading condition. The objective of the present study was to investigate the regional variability of the biaxial strain versus pressure relationship based on the types of fixation liquid models. Material and Method: Porcine aortic valves and pulmonary valves were assigned to three groups: the untreated fresh group, the fixed with glutaraldehyde (GA) group, and the glutaraldehyde with solvent (e.g., ethanol) group. For each group we measured the radial and circumferential stretch characteristics of the valve as a function of pressure change. Result: Radial direction elasticity of porcine aortic and pulmonary valves were better than circumferential direction elasticity in fresh, GA fixed and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of pulmonary valves were better than aortic valves in GA fixed, and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of aortic valves were decreased after GA and GA+solvent fixation(p=0.00), except for circumferential elasticity of GA+solvent fixed valves (p=0.785). The radial (p=0.137) and circumferential (p=0.785) direction of elasticity of aortic valves were not significantly different between GA fixed. and GA+solvent fixed groups. Radial (p=0.910) and circumferential (p=0.718) direction of elasticity of pulmonary valve also showed no significant difference between GA fixed and GA+solvent fixed groups. Conclusion: When fixing porcine valves with GA, adding a solvent does not cause a loss of mechanical properties, but, does not improve elasticity either. Radial direction elasticity of porcine aortic and pulmonary valves was better than circumferential direction elasticity.

The Second Animal Tests of Artificial Heart Valves (인공심장판막의 개발과 동물실험 -인공심장판막의 2차 동물실험-)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.23 no.4
    • /
    • pp.617-621
    • /
    • 1990
  • A heart supplies blood of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to accomplish these enormous work of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of blood. In an attempt to eliminate the affliction of heart valves, the operative method to replace with artificial heart valves has developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. New artificial heart valves have been developed in Korea Advanced Institute of Science and Technology since early 1980`s. The first developed valve was designed with a free-floating pyrolytic carbon disk that is suspended in a titanium cage. The design of the valve was tested in vitro, and in animals in 1987. The results from this study was that the eccentrically placed struts creates a major and minor orifice when the disc opens and stagnation of flow in the area of the minor orifice has led to valve thrombosis. In this work, the design of the valve was changed from a single - leaflet valve to double - leaflet one in order to resolve the problems observed in the first - year tests. Morphological and hemodynamic studies were made for the newly designed valves through the in vitro and in vivo tests. The design and partial materials of the artificial heart valve was improved comparing with first - year`s model. The disc in the valve was modified from single - leaflet to bi - leaflet, and the material of the cage was changed from titanium metal to silicon - alloyed pyrolytic carbon. A test was made for the valve in order to examine its mechanical performance and stability. Morphological and hemodynamic studies were made for the valve that had been implanted in tricuspid position of mongrel dogs. All the test animals were observed just before the deaths. A new artificial heart valve was designed and fabricated in order to resolve the problems observed in the old model. The new valve was verified to have good stability and high resistance to wear through the performance tests. The hemodynamic properties of the valve after implantation were also estimated to be good in animal tests. Therefore, the results suggest that the newly designed valve in this work has a good quality in view of the biocompatibility. However, valve thrombosis on valve leaflets and annulus were found. This morphological findings were in accordance with results of surface polishing status studies, indicating that a technique of fine polishing of the surface is necessary to develop a valve with higher quality and performance.

  • PDF

A study on the condition assessment of large diameter water valves using non-destructive technologies (비파괴 기술을 이용한 대구경 수도용 밸브의 상태평가에 관한 연구)

  • Ho-Min Lee;Hyun-yong Choi;Suwan Park;Tae-min Oh;Chae-Min Kim;Cheol-Ho Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.4
    • /
    • pp.215-229
    • /
    • 2023
  • In this study, non-destructive technologies that can be applied to evaluate the integrity of valve materials, safety against internal pressure caused by corrosion, and the blocking function of large-diameter water valves during operation without requiring specimen collection or manpower entering the inside of the valve were tested to assess the reliability of the technologies and their suitability for field application. The results showed that the condition of the graphite structure inside the valve body can be evaluated directly through the optical microscope in the field without specimen collection for large-diameter water butterfly valves, and the depth of corrosion inside the valve body can be determined by array ultrasound and the tensile strength can be measured by instrumented indentation test. The reliability of each of these non-destructive techniques is high, and they can be widely used to evaluate the condition of steel or cast iron pipes that are significantly smaller in thickness than valves. Evaluation of blocking function of the valves with mixed gas showed that it can be detected even when a very low flow rate of mixed gas passes through the disk along with the water flow. Finally, as a result of evaluating the field applicability of non-destructive technologies for three old butterfly valves installed in the US industrial water pipeline, it was found that it is possible to check the material and determine the suitability of large-diameter water valves without taking samples, and to determine the corrosion state and mechanical strength. In addition, it was possible to evaluate safety through the measurement results, and it is judged that the evaluation of the blocking function using mixed gas will help strengthen preventive response in the event of an accident.

The Reliability Evaluation of TBN Valve Testing Extension in NPP (원자력발전소 터빈밸브 시험주기 연장시 신뢰도평가)

  • Lim, Hyuk-Soon;Lee, Eun-Chan;Lee, Keun-Sung;Hwang, Seok-Won;Seong, Ki-Yeoul
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3221-3223
    • /
    • 2007
  • Recently, nuclear power plant companies have been extending the turbine valve test interval to reduce the potential of the reactor trip accompanied with a turbine valve test and to improve the NPP's economy through the reduction of unexpected plant trip or decreased operation. In these regards, the extension of the test interval for turbine valves was reviewed in detail. The effect on the destructive overspeed probability due to the test interval change of turbine valves is evaluated by Fault Tree Analysis(FTA) method. Even though the test interval of turbine valves is changed from 1 month to 3 months, the analysis result shows that the reliability of turbine over speed protection system meets acceptance criteria of 1.0E-4/yr. This result will be used as the technical basis on the extension of the test interval for turbine valves. In this paper, the propriety of the turbine valve test interval extension is explained through the review on the turbine valve test interval status of turbine overspeed protection system, the analysis on the annual turbine missile frequency and the probability evaluation of the destructive overspeed due to the test interval extension.

  • PDF

Development of Bi-directional Triple-eccentric Type Butterfly Valve (양방향 삼중편심 버터플라이 밸브 개발)

  • Kim, Soo-Young;Lee, Dong-Myung;Bae, Jung-Hoon;Shin, Sung-Chul;Sul, Chang-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.5
    • /
    • pp.545-551
    • /
    • 2009
  • In naval architecture and offshore engineering, the development and a broad use has been achieved in the field of flow control valves for pipe system. Butterfly valves are also widely used for flow control, but there are not many studies for triple-eccentric butterfly valves. Moreover, if the fluid of pipeline flows in the bi-direction then it makes more complicate to adapt triple-eccentric butterfly valves to flow control. In this study, we are trying to develop a bi-directional triple-eccentric butterfly valve through sealing mechanism and stem design study. Digital mockup using 3D CAD was constructed for shape interference check and structural analysis was conducted for structural safety. Also we performed leakage test to check out the durability of the bi-directional pressure for the developed valve.

A Case Study on the Failure of Intake and Exhaust Valves for Marine Diesel Engines

  • Kim Jong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.801-807
    • /
    • 2005
  • Any failure of intake and exhaust valves of marine diesel engine must be regarded as serious, and any steps which can be taken to prevent such failure are desirable. The purposes of this study is to investigate and to analyse the failure causes of intake and exhaust valves for marine diesel engine during sea trial after completion of overhauling. In this study, to analyse the failure causes, we have carried out on board inspection, fractography test and discussion based on the specimen and repairing report provided by the ship owner. From the results of above inspection, test and discussion, it has been considered reasonable to conclude that the causes of damaged valves of the ship are as follow ; 1) During operation, the stick or seizure of valve spindle occurred and hence the movement of exhaust valve spindle was to be resisted and subsequently the engine was to be operated under an unappropriated valve timing and the exhaust valve sustained the repeated loads exceeding the fatigue strength of valve material. 2) By the loads above described, the fatigue fracture was initiated at the structural noncontinuous part of exhaust valve spindle, and then the valve head was finally fractured and dropped in the cylinder. 3) The fractured exhaust valve head impacted the intake valve at various direction to be bent or damaged.

Cardiac Valve Replacement and Anticoagulation (심장판막치환환자와 항응혈치료)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.11 no.3
    • /
    • pp.303-315
    • /
    • 1978
  • During the full 10-year period from June 1968 through June 1978, 112 consecutive patients underwent isolated or double valve replacement. A total of 130 valves were used in aortic, mitral or tricuspid positions: 63 prosthetic valves in 56 and 67 glutaraldehyde-preserved porcine aortic valves in 56 patients. There were 31 early and 9 late deaths with a cumulative mortality rate of 35.7 percent. Eighty-five patients survived longer than 10 days postoperatively were studied for the occurrence of thromboembolism and complications related to anticoagulant therapy. At the end of follow-up period, 68 patients were on Coumadin; 74 were on Persantin with or without Coumadin; 11 were off any antithrombotic drugs with 6 of them being off electively after 6 months of tissue valve replacement. Thromboembolism occurred in 7 [8.2%] of 85 patients or 10.9%/patient-year. Embolic rates were as follows: one of 18 patients anticoagulated [5.6%] or 6.1%/patient-year and 4 of 16 patients not anticoagulated [25.0%] or 17.8%/patient-year for the prosthetic valve replacement; and one of 40 patients anticoagulated [2.5%] or 7.9%/patient-year and one of 11 patients not anticoagulated [9.1%] or 7.9%/patient-year for tissue valve replacement. Three complications of major bleeding were experienced by 3 patients during the follow-up period, being related to Coumadin therapy. The importance of proper anticoagulation were stressed for the successful management of patients after cardiac valve replacement, both prosthetic and tissue valves.

  • PDF