• Title/Summary/Keyword: valve rate

Search Result 980, Processing Time 0.031 seconds

Implementation of a Mixing-Ratio Control System for Two-Component Liquid Silicone Mixture (이액형 액상실리콘 재료의 혼합비율 제어 시스템 개발)

  • Choo, Seong-Min;Kim, Young-Min;Lee, Keum-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.688-694
    • /
    • 2018
  • The mixture ratio of two-component liquid silicone is important for the inherent physical characteristics of the finished product. Therefore, it is necessary to uniformly control the ratio of the main material and the sub-material. In this paper, a mixing-ratio control system was designed, which consists of a digital flow meter and a flow control system to measure the flow rate of the raw materials and a pumping system to maintain constant pressure and transfer of the raw materials. In addition, a program was developed to control the organic interlocking and mixing ratio. For the verification of the developed system, we compared the actual weight of raw material with the value measured by the flow meter during pumping, and we measured the physical properties of the mixed material by making test samples with and without the application of the mixing-ratio improvement algorithm. The measured value was close to the reference value with a hardness range of 46-47 and tensile strength of 9.3-9.5 MPa. These results show that the mixing ratio of the liquid silicone is controlled within an error range of ${\pm}0.5%$.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

Long-Term Outcomes of Preoperative Atrial Fibrillation in Cardiac Surgery

  • Kim, Hyo-Hyun;Kim, Ji-Hong;Lee, Sak;Joo, Hyun-Chel;Youn, Young-Nam;Yoo, Kyung-Jong;Lee, Seung Hyun
    • Journal of Chest Surgery
    • /
    • v.55 no.5
    • /
    • pp.378-387
    • /
    • 2022
  • Background: Atrial fibrillation (Afib) is a marker of increased cardiovascular morbidity and mortality. Owing to the increased prevalence of Afib in patients undergoing cardiac surgery, assessing the effect of Afib on postsurgical outcomes is important. We aimed to analyze the effect of preoperative Afib on clinical outcomes in patients undergoing cardiac surgery using a large surgical database. Methods: This retrospective cohort study was based on the national health claims database established by the National Health Insurance Service of the Republic of Korea from 2009 to 2015. Diagnosis and procedure codes were used to identify diseases according to the International Statistical Classification of Diseases, 10th revision. Results: We included 1,037 patients (0.1%) who had undergone cardiac surgery from a randomized 1,000,000-patient cohort, and 15 patients (1.5%) treated with isolated surgical Afib ablation were excluded. Of these 1,022 patients, 412 (39.7%), 303 (29.2%), and 92 (9.0%) underwent coronary artery bypass, heart valve surgery, and Cox-maze surgery, respectively. Preoperative Afib was associated with higher patient mortality (p=0.028), regardless of the surgical procedure. Patients with preoperative Afib (n=190, 18.6%) experienced a higher cumulative risk of overall mortality (hazard ratio [HR], 1.435; 95% confidence interval [CI], 1.263-2.107; p=0.034). Subgroup analysis revealed a reduced risk of overall mortality with Cox-maze surgery in Afib patients (HR, 0.500; 95% CI, 0.266-0.938; p=0.031). Postoperative cerebral ischemia or hemorrhage events were not related to Afib. Conclusion: Preoperative Afib was independently associated with worse long-term postoperative outcomes after cardiac surgery. Concomitant Cox-maze surgery may improve the survival rate.

Fully Automatic Coronary Calcium Score Software Empowered by Artificial Intelligence Technology: Validation Study Using Three CT Cohorts

  • June-Goo Lee;HeeSoo Kim;Heejun Kang;Hyun Jung Koo;Joon-Won Kang;Young-Hak Kim;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1764-1776
    • /
    • 2021
  • Objective: This study aimed to validate a deep learning-based fully automatic calcium scoring (coronary artery calcium [CAC]_auto) system using previously published cardiac computed tomography (CT) cohort data with the manually segmented coronary calcium scoring (CAC_hand) system as the reference standard. Materials and Methods: We developed the CAC_auto system using 100 co-registered, non-enhanced and contrast-enhanced CT scans. For the validation of the CAC_auto system, three previously published CT cohorts (n = 2985) were chosen to represent different clinical scenarios (i.e., 2647 asymptomatic, 220 symptomatic, 118 valve disease) and four CT models. The performance of the CAC_auto system in detecting coronary calcium was determined. The reliability of the system in measuring the Agatston score as compared with CAC_hand was also evaluated per vessel and per patient using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. The agreement between CAC_auto and CAC_hand based on the cardiovascular risk stratification categories (Agatston score: 0, 1-10, 11-100, 101-400, > 400) was evaluated. Results: In 2985 patients, 6218 coronary calcium lesions were identified using CAC_hand. The per-lesion sensitivity and false-positive rate of the CAC_auto system in detecting coronary calcium were 93.3% (5800 of 6218) and 0.11 false-positive lesions per patient, respectively. The CAC_auto system, in measuring the Agatston score, yielded ICCs of 0.99 for all the vessels (left main 0.91, left anterior descending 0.99, left circumflex 0.96, right coronary 0.99). The limits of agreement between CAC_auto and CAC_hand were 1.6 ± 52.2. The linearly weighted kappa value for the Agatston score categorization was 0.94. The main causes of false-positive results were image noise (29.1%, 97/333 lesions), aortic wall calcification (25.5%, 85/333 lesions), and pericardial calcification (24.3%, 81/333 lesions). Conclusion: The atlas-based CAC_auto empowered by deep learning provided accurate calcium score measurement as compared with manual method and risk category classification, which could potentially streamline CAC imaging workflows.

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

20 Years Surgical Experiences for Ebstein's Anomaly (엡스타인 기형의 20년 수술 치험)

  • Lee, Sak;Park, Han-Ki;Lee, Chang-Young;Chang, Byung-Chul;Park, Young-Hwan
    • Journal of Chest Surgery
    • /
    • v.40 no.4 s.273
    • /
    • pp.280-287
    • /
    • 2007
  • Background: We retrospectively evaluated the clinical results of surgically managing patients with Ebstein's anomaly. Material and Method: Between Feb. f 984 and June 2006, 50 patients who underwent surgical treatment for Ebstein's anomaly at Yonsei Cardiovascular Center were retrospectively reviewed. The mean age of the patients was 26.9 years and 19 patients were male, Associated anomalies included atrial septal defect (33), patent ductus arteriosus (2), ventricular septal defect (1), and pulmonary stenosis (4), and 90%, (45/50) of the patients had more than a moderate degree of tricuspid regurgitation. Carpentier type A was present in 6 patients, type B in 26, type C in 14 and type D in 4. Ten patients were associated with WPW syndrome. Conservative surgery was possible in 31 patients (tricuspid annuloplasty, plication of the atrialized RV), Fontan's operation was peformed in 4 patients, tricuspid valve replacement was done in 12 and palliative surgery was done in 2 patients. Thirteen patients were associated with hi-directional cavopulmonary shunt (BCPS: one and a half ventricular repairs): 10 patients with WPW syndrome and 4 patients with atrial fibrillation underwent concomitant ablation. Result: The postoperative median NYHA functional class $(3{\rightarrow}1)$ and the mean cardio-thoracic ratio $(0.65{\rightarrow}0.59)$ were decreased significantly (p<0.001, p=0.014). The mean oxygen saturation $(86.6{\rightarrow}94.1%)$, and median TR grade $(4{\rightarrow}1)$ were also significantly improved (p=0.004, p<0.001). For comparison of BCPS and conservative surgery, the preoperative right ventricular pressure (33.0 vs. 41.3 mmHg), the ICU stay (2.80 vs. 1.89 days), the hospital say (10.6 vs. 16.8 days), and the left ventricular ejection fraction (64.3 vs. 72.8%) were statistically different. Postoperative mortality occurred in 3 patients (6%) due to biventricular failure in 2 patients and sepsis in the other patient. The mean follow up duration was 101.5 months, and one patient died of Fontan failure and 6 patients required reoperation (bioprosthetic degenerative change (2) and Fontan conversion (4)). The overall survival rate at 10 years was 90.2%, the freedom from reoperation rate and rate of cardiac related events were 78.9% and 49.2%, respectively. Conclusion: Surgical management of Ebstein's anomaly can be performed safely, and the associated BCPS may be helpful for high-risk patients. Adequate application of surgical management may increase the long-term survival with a reduced rate of reoperation.

Early Results of Coronary Artery Bypass Graft with Purely Bilateral Internal Thoracic Arteries Using Y-anastomosis in Multiple Coronary Artery Disease Patients: Coronary Angiographic Analysis (다중혈관 관상동맥 환자에서 Y-문합을 이용하여 양쪽 내흉동맥만을 사용한 우회술의 조기 성적: 관상동맥 조영술 분석)

  • 성기익;이영탁;박계현;전태국;박표원;한일용;장윤희
    • Journal of Chest Surgery
    • /
    • v.36 no.3
    • /
    • pp.142-149
    • /
    • 2003
  • To know the feasibility of the coronary artery bypass graft (CABG) for multivessel coronary artery disease with purely bilateral internal thoracic arteries (ITAs), we analyzed the short-term clinical results and the coronary angiography of the patients. Material and Method: From March 2001 to June 2002, four hundred and five patients underwent CABG. Purely bilateral ITAs were used in 159 patients (39.3%). We analyzed these patients retrospectively The mean age of these patients was $61.2{\pm}8.5$ (range: 30 ~80) years and there were 123 male patients. The preoperative risk factors were as follows: diabetes in 54 patients (34.0%), history of acute myocardiac infarction within 4 weeks in 29 (18.2%), and emergency operation in 6 (3.8%). Off-pump CABG was carried out in 128 patients (80.5%). Associated procedures were mitral valvuloplasty (5), aortic valve replacement (3), Dor procedure (1), and so on. Result: The mean number of distal anastomoses was $3.1{\pm}0.9$ (range: 2~6), the mean duration of hospital stay was $8.4{\pm}4.5$ days. There was one (0.6%) operative death. Except for one early death, no other patients suffered from low cardiac output. The other postoperative complications were occurred as follows: reoperation due to bleeding in 3 patients, perioperative myocardiac infarction in 1, transient cardiac arrest in 2, transient cognitive dysfunction in 7, and transient ischemic attack in 1, and deep sternal wound infection in 1 patient. Recently, early postoperative angiography was performed in 19 patients who had triple vessel disease. The total number of distal anastomosis was 78 (mean $4.1{\pm}0.8$/patient). All distal anastomosis sites were patent, but competition flow was observed at the bypass sites where the native coronary artery stenosis was not significant. Conclusion: The CABG with purely bilateral ITAs for triple vessel disease was performed safely. The early patency rate was relatively good in small number of patients. However the long-term patency rate and the functional study to evaluate the sites where competition flow was observed should be followed.

Clinical Analysis to the Early Results of the CABG (관상동맥우회술의 조기 성적에 대한 임상적 고찰)

  • Kim, Dae-Sig;Yang, Jin-Young;Koo, Won-Mo;Moon, Seung-Chul;Lee, Gun;Lee, Hyeon-Jae;Lim, Chang-Young
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1043-1048
    • /
    • 1998
  • Background: As coronary arterial disease is increasing, we evaluated the patients who underwent CABG(Coronary Artery Bypass Grafting) and thus report the early results and risk factors related to mortality and morbidity. Materials and methods: Between July 1996 and February 1998, 42 patients underwent CABG. We analyzed age, sex, preoperative ejection fraction, Canadian heart classification, prevalence factors of CAD(Coronary Artery Disease), angiographic findings, graft vessel numbers, IMA(Internal Mallary Artery) use, ECC* (extracorporeal circulation) time and morbidity. We also evaluated the mortality rate and the causes of death. Results: Complication was developed at 17cases. The average age of the complication group was 61±11.9 years and that of the noncomplication group was 51±10.5 years(p=0.004). ECC time was 198±42.5(min) in the complication group and 158±47.4(min) in the noncomplication group(p=0.008). The other factors had no correlation to the morbidity, statistically. The average follow up duration was 12.5 months and all the patients were alive except for the 2 expired cases. The mortality rate was 4.7%, among which one patient who underwent CABG with aortic valve replacement died due to multiorgan failure and the other died due to sepsis with pneumonia and wound infection. Conclusions: We conclude that the risk factors related to morbidity were age and ECC time, and that there were no correlations between other factors and morbidity.

  • PDF

Clinical Analysis of Disease Recurrence for the Patients with Secondary Spontaneous Pneumothorax (이차성 자연기흉 환자의 재발양상에 관한 분석)

  • Ryu, Kyoung-Min;Kim, Sam-Hyun;Seo, Pil-Won;Park, Seong-Sik;Ryu, Jae-Wook;Kim, Hyun-Jung
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.619-624
    • /
    • 2008
  • Background: Secondary spontaneous pneumothorax is caused by various underlying lung diseases, and this is despite that primary spontaneous pneumotherax is caused by rupture of subpleural blebs. The treatment algorithm for secondary pneumothorax is different from that for primary pneumothorax. We studied the recurrence rate, the characteristics of recurrence and the treatment outcomes of the patients with secondary spontaneous pneumothorax. Material and Method: Between March 2005 to March 2007, 85 patients were treated for their first episodes of secondary spontaneous pneumothorax. We analyzed the characteristics and factors for recurrence of secondary spontaneous pneumothorax by conducting a retrospective review of the medical records. Result: The most common underlying lung disease was pulmonary tuberculosis (49.4%), and the second was chronic obstructive lung disease (27.6%), The recurrence rate was 47.1% (40/85). The second and third recurrence rates were 10.9% and 3.5%, respectively. The mean follow up period was $21.1{\pm}6.7$ months (range: $0{\sim}36$ month). For the recurrence cases, 70.5% of them occurred within a year after the first episode. The success rates according to the treatment modalities were thoracostomy 47.6%, chemical pleurodesis 74.4%, blob resection 71% and Heimlich valve application 50%. Chemical pleurodesis through the chest tube was the most effective method of treatment. The factor that was most predictive of recurrence was 'an air-leak of 7 days or more' at the first episode. (p=0.002) Conclusion: The patients who have a prolonged air-leak at the first episode of pneumothorax tend to have a higher incidence of recurrence. Further studies with more patients are necessary to determine the standard treatment protocol for secondary spontaneous pneumothorax.

The Results of using the Cabrol Technique for Aortic Root Replacement (대동맥 근부치환술에 대한 Cabrol 술식의 성적)

  • Kim, Jeong-Won;Lee, Jong-Tae;Cho, Joon-Yong;Kim, Kyu-Tae;Kim, Gun-Jik
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.573-579
    • /
    • 2008
  • Background: Composite valve graft replacement is currently the treatment of choice for a wide variety of the lesions of aortic root disease. The purpose of this study was to explore the results of aortic root replacement after using the Cabrol technique over a 13-year period at our institution, and we analyzed the results to help surgeons make better decisions when repairing aortic root disease. Material and Method: Between January 1994 and December 2006, twenty-five patients underwent a Cabrol technique operation at our institution. The mean patient age was $43.7{\pm}14.1$ years old (range: $6{\sim}65$ years) and the male and female ratio was 21:4 (84% : 16%). The patients' follow-up was 100% complete, and the mean follow-up period was $60.7{\pm}50.4$ (range:$1{\sim}162$) months. Annuloaortic ectasia (n=18) was the most frequent cause of aortic disease in this series, followed by aortic dissection (n=7). The mean cardiopulmonary bypass time was $177.2{\pm}44.9$ minutes and the mean aortic cross clamping time was $123.4{\pm}34.1$ minutes. Nine patients were checked with MDCT (Multidetector computed tomography) for evaluating a well functioning secondary graft and the coronary anastomosis site. Result: The early mortality rate was 4% (1 of 25 patients). A significant stenosis, kinking or occlusion of the secondary graft was detected by MDCT in 4 patients. The overall survival rate was 88%. Conclusion: The Cabrol technique demonstrated a significant incidence of long-term complications such as secondary graft stenosis or obstruction. It could be used when the modified Bentall technique is not feasible.