• Title/Summary/Keyword: valve defect

Search Result 228, Processing Time 0.307 seconds

Trido Mitral Valve Replacement with Dacron Collar Prosthetic Valve due to Paravalvular Leak (판막주위 누출에 대한 다크론 확장 인공판막을 이용한 판막치환술 치험)

  • 배윤숙;정성철;김우식;정승혁;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.822-825
    • /
    • 2002
  • The paravalvular leak after redo mitral prosthetic valve replacement is rare but serious complication when it does happen. This condition should be corrected surgically to increase life span and improve symptoms. But simple closure or patch closure of paravalvular leak are not effective in cases of weak annulus or broad defect. We report 3 cases of trido mitral valve replacement using mechanical valve with its sewing ring expanded by a collar of Dacron sheet. The prosthetic sewing ring is anchored on the weak mitral annulus with multiple interrupted sutures, while the Dacron collar is contineuously sutured to the left atrial wall for blood tight sealing. All of the three cases showed event free postoperative course.

Multiple Cardiac Papillary Fibroelastoma of the Aortic Valve (대동맥 판막에 위치한 다발성 심장 유두상 섬유탄력종)

  • Seo, Hong-Joo;Na, Chan-Young;Yu, Jai-Kun
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.496-498
    • /
    • 2008
  • Cardiac papillary fibroelastomas are the second most common primary cardiac tumor. This tumor is usually benign and it involves the cardiac valve. However, most cardiac papillary fibroelastomas originate from a single site, and the incidence of cardiac papillary fibroelastomas originating from multiple sites is very rare (5%). A 55-year-old woman who presented with momentary dizziness and syncope was evaluated by performing echocardiography. Multiple tumors attached to the aortic valve were noted. The mass was removed freely without leaving any defect on the aortic valve leaflet. After the recovery period, the patient is currently being followed up at the outpatient department.

Mitral Valve Replacement : A Report of 238 cases (승모판막 대치이식술 238예 보고)

  • Lee, Yung-Kyoon;Yang, Gi-Min
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.422-434
    • /
    • 1980
  • Since 1968 up to the end of October 1980, 448 valves were replaced in 354 patients in Seoul National University Hospital. There were 238 mitral, 38 aortic, 7 tricuspid, 45 aortic with mitral, 23 tricuspid with mitral, and 3 triple valve replacement aortic mitral and tricuspid cases. Annual increase of mitral valve replacement cases and decrease of operative maortality were remarkable. Recently operative mortality of mitral valve replacement is about 5%. Sex ratio of mitral valve replacement is almost equal and there were 12 cases of pediatric patients (5%) among 238 cases, and patients under the age of 20 years were 34 (14.3%). Mitral valve replacement was done for 199 single mitral, 38 double valve and one triple valve lesions. Among 238 mitral valve replacement paients left atrial thrombus in 23(9.7%), atrial fibrillation in 132 (55.5%), and reoperation after blind mitral commissurotomy in 12(5%) cases were noted. In recent cases bioprosthetic valves, mainly lonescu-shiley valve were utilized to overcome the difficulties of postoperative late complications in anticoagnuation, especially for the rural patients and pediatric cases, in addition to the hemodynamic advantages of lonesocu valve. Among 354 patients 16 cases were congenital heart anomaly related, 5 ventricular septal defect related aortic and 4 Ebstein related tribuspid valve replacement cases. There were 2 congenital anomaly related mitral valve replacements, one for congenital mitral insufficiency of 7 years old boy and one for corrected transposition of the great vessels associated with mitral insufficiency. Among total 354 valve replacements 49 operative deaths (13.3%) were noted and in 238 mitral valve replacement 24 operative deaths occurred (10.1%). In 39 patients among 354 total valve replacements late complications were found. In 238 mitral valve replacement cases late complications were noted in 26 patients, among whom 16 cases expired. Main late complications were thrombe-embolism, subacute becteerial endocarditis, arrythmia cerebral hemorrhage due to unsatisfactory anticoagulation, and congestive heart failure in the incipient period of valve replacement were also noted. In mitral valve replacement cases long-term survival rate was 83.2% who showed marked clinical improvement. Ther were no evidences of calcification during the 2 years follow-up period for the lonescu-valve replacement cases among 19 pediatric patients. In conclusion 238 cases of mitral valve replacement were done with 24 operative deaths and 26 late complication cases among whom 16 expired. The long term survival was 83.2% of the cases. In pediatric cases in place of coumadin anticoagulation Persantin **** 75 and aspirin were administered after valve replacement. In adult cases who have difficulaties with coumadin anticoagulation and for those even with bioprosthetic heart valve replacement who needs long-term or permanent anticoagulation persantin 75 and aspirin combination regimen were administered with antisfactory results.

  • PDF

Clinical Results of Mitral Valve Repair (승모판막질환의 판막재건술36례 성적)

  • Jang, Bong-Hyeon;Han, Seung-Se;Kim, Gyu-Tae
    • Journal of Chest Surgery
    • /
    • v.21 no.1
    • /
    • pp.70-81
    • /
    • 1988
  • From January 1962 to March 1987, 97 patients underwent operation for mitral valve disease. Of these patients, 61 [62.9%] required mitral valve replacement. Thirty-six patients [37.1%] had mitral valve repair. The mean age was 26.9*11.6 years [range 5 months to 48 years]. There were 32 [88.9%] cases of rheumatic valve disease, 4 [11.1%] cases of congenital mitral valve disease. Valve dysfunction was classified into three types: type I [normal leaflet motion], 6 patients; type II [prolapsed leaflet], 1 patient; type III [restricted leaflet motion], 29 patients. Twenty-nine patients [80.6%] had pure or predominant stenosis and 7[19.4%] had pure regurgitation. No patient was in NYHA functional class I. Three patients [16.7%] were in functional class II, 15[83.3%] were in functional class II. The techniques used included closed mitral commissurotomy [16 patients], open mitral commissurotomy [13 patients], localized Wooler type annuloplasty [4 patients], suture repair of leaflet defect [3 patients], chordal shortening [1 patient], Carpentier ring annuloplasty [1 patient], and fenestration of fused chordae [1 patient]. There were two perioperative deaths [5.6%], related to left ventricular failure and reoperation. The survivors were followed up for 94 patient-years [mean 4.68*5.54 years]. One late death [1.1*1.1% per patient-year] occurred and was valve related. Reoperation was required in 3 patients, of whom 2 were deaths. There was 1 case [1.1*1.1% per patient-year] of thromboembolism. No patient received anticoagulant after operation. At 10 year, 92*7.4% of the patients were still alive. The actuarial survival rate of patients free of valve-related complication was 79*6.4% at 6 years, 27*12.1% at 11 years. After surgery, 18 patients [88.9%] were in NYHA functional class I or II.

  • PDF

Study on the Self Diagnostic Monitoring System for an Air-Operated Valve : Algorithm for Diagnosing Defects

  • Kim Wooshik;Chai Jangbom;Choi Hyunwoo
    • Nuclear Engineering and Technology
    • /
    • v.36 no.3
    • /
    • pp.219-228
    • /
    • 2004
  • [1] and [2] present an approach to diagnosing possible defects in the mechanical systems of a nuclear power plant. In this paper, by using a fault library as a database and training data, we develop a diagnostic algorithm 1) to decide whether an Air Operated Valve system is sound or not and 2) to identify the defect from which an Air-Operated Valve system suffers, if any. This algorithm is composed of three stages: a neural net stage, a non-neural net stage, and an integration stage. The neural net stage is a simple perceptron, a pattern-recognition module, using a neural net. The non-neural net stage is a simple pattern-matching algorithm, which translates the degree of matching into a corresponding number. The integration stage collects each output and makes a decision. We present a simulation result and confirm that the developed algorithm works accurately, if the input matches one in the database.

Double Mitral Valve Orifice in Atrioventricular Canal Defects (방실관결손증에 동반된 이중승모판 -2례 보고-)

  • Kim, Su-Won;Jo, Beom-Gu
    • Journal of Chest Surgery
    • /
    • v.21 no.4
    • /
    • pp.757-760
    • /
    • 1988
  • Double mitral valve orifice is an unusual congenital abnormality, and is rarely of clinical importance. That abnormality not produce hemodynamic deficits, but it has been associated with other congenital heart diseases, especially atrioventricular canal defects, and so it is surgically important condition. After the first report by M.S. Greenfield in 1876, there are only a few reported cases all over the world. We experienced two cases of double mitral valve orifice with atrioventricular canal defect. The small accessory mitral orifice was placed in anterior mitral leaflet as a hole type in both cases. The A-V canal defects are corrected with a one patch technique, but the accessory orifices are left unclosed because there were no mitral regurgitations through the orifice. On the 4th postoperative day, the patients have been performed echocardiography; both had no mitral regurgitation. Both of patients are now being follow-up and we find no specific problems. A small accessory mitral orifice may be left unclosed and rarely produce significant regurgitation, conclusively.

  • PDF

Tricuspid Valve Endocarditis (삼첨판막 심내막염)

  • 문광덕;김대영
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.440-443
    • /
    • 1996
  • Some tricuspid valve endocarditis can be controlled effectively with specific antibiotic treatment. However, surgical intervention Is necessary when there are continuing sepsis, moderate or severe heart failure, multiple pulmonary emboli, and echocardiographycally demonstrated vegitations. We are repoting a 19 year-old male patient who was admitted for the treatment of infective endocarditis. He previously had an operation for ventriculer septal defect (perimembranous type) about 9 years ago . An echocardiogram showed a large vegetation on the anterior cusp area and a left to right shunt through VSD, which was previously closed with dacron patch. A valve replacement in addition to antibiotic therapy was recommended for the patient. The patient underwent on operation : tricuspid valve replacement was done with 51. Jude medical valve prosthesis (33 mm), and in addition to above procedure, removal of vegetation and direct closure of VSD were done Postoperative echocardiogram showed that replaced tricuspid valve functioned well and vegeta ion and shunt flow were not observed. The patient recovered without complication and discharged at Postoperative day 25. Early aggressive surgical intervention is indicated to optimize surgical results, and this case seems to be a typical right sided bacterial endocarditis, which is caused by residual VSD. We are reporting a case of tricuspid valve endocarditis with a review of the literature. (Korean J Thorax Cardiovasc Surg 1996 ; 29: 440-3)

  • PDF

Numerical Analysis for Evaluation of Ejection Capacity Relationship of Safety Valves in Pressure Regulating Station (II) - Flow Analysis and Required Effective Discharge Area of Safety Valve - (정압기지내의 안전밸브 분출용량 관계식 검증을 위한 유동해석 (II) - 안전밸브 유동 해석 및 필요분출면적 -)

  • Gwon, Hyuk-Rok;Roh, Kyung-Chul;Kim, Young-Seop;Lee, Seong-Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.105-109
    • /
    • 2008
  • A safety valve has a valve mechanism for the automatic release of gas from piping system when the pressure exceeds preset limit cause of a defect of a pressure regulator, condensation of water in a pipe. Therefore, for the safety of pressure regulating station, it is essential to study the flow regime and characteristics of safety valve. This article presents the numerical analysis on the flow analysis, the ejection capacity and required effective discharge area of the safety valve that is established in pressure regulating station. Then, the results are compared and analyzed with domestic and foreign regulations such as API(America Petroleum Institute), EN(European Standard), and NF(Norme Francise). Moreover, the installation number of safety valve is considered by using domestic and foreign regulations and maximum reguired effective discharge area of safety valve.

  • PDF

Aorticopulmonary Window: one case report (대동맥중격결손증[수술치험 1예])

  • 최영호
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.302-306
    • /
    • 1981
  • Aorticopulmonary window is a rare anomaly among congenital heart disease. Various terms have been suggested including A-P window, A-P fenestration, fistula, aorticseptal defect etc. The defect lies usually between the left side of the ascending aorta and right wall of the pulmonary artery just anterior to the origin of the right main pulmonary artery. We have experienced one case of aorticopulmonary septal defect which was diagnosed as V5D with pulmonary hypertension in 1 4/12 year old, 7.2 Kg, male patient. Operation was done under the hypothermic cardiopulmonary bypass using 5t. Thomas cardioplegic solution. Vertical right ventriculotomy over the anterior wall of RVOT revealed no defect in the ventricular septum, and incision was extended up to the main pulmonary artery to find the source of massive regurgitation of blood through MPA. Finger tip compression of the aorticopulmanary window was replaced with Foley bag catheter balloon, and the $7{\times}10$ mm aorticoseptal defect located 15mm above the pulmonic valve was sutured continuously wih 3-0 nylon suture during azygos flow of cardiopulmonary cannula which was located distal to the window resulted massive air pumping systemically, and temporary reversal of pumping was tried to minimize cerebral air embolism. Remained procedure was done as usual, and pump off was smooth and uneventful. Postoperatively, patient was attacked frequent opistotonic seizure with no recovery sign mentally and p.hysically. Vital signs were gradually worsen with peripheral cyanosis and oliguria, and cardiac activity was arrested 1485 minutes after operation. Autopsy was performed to find the sutured window and massive edema of the brain.

  • PDF

Case Report of Partial Endocardial Cushion Defect with Mild Pulmonary Hypertension in Old Age (경증의 폐동맥 고혈압을 동반한 고령에서의 심내막상 결손 환자 치험 1예)

  • Kim Woo-Shik;An Jae-Bum;Song Chang-Min;Kim Mi-Jung;Jung Sung-Chol;Shin Yong-Chul;Kim Byung-Yul;Kim In-Sub
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.633-636
    • /
    • 2006
  • The partial endocardial cushion defect including ostium primum atrial septal defect and anterior mitral leaflet cleft, presents less significant clinical symptoms than complete endocardial cushion defect. But, as mitral insufficiency develops, cardiomegaly, congestive heart failure, pulmonary arterial hypypertension appear. So, partial endocardial cushion defect has poor prognosis and is rarely seen in elderly patients. A 67 years old woman admitted at our hospital for operative treatment with partial endocardial cushion defect. She had increased pulmonary pressure of 45/22 mmHg, mean 32 mmHg. She had repair of ostium primum defect with patch, and the mitral valve was treated with valve replacement. Because advanced atrioventricular block developed postoperatively, she received permanent pacemaker.