The paravalvular leak after redo mitral prosthetic valve replacement is rare but serious complication when it does happen. This condition should be corrected surgically to increase life span and improve symptoms. But simple closure or patch closure of paravalvular leak are not effective in cases of weak annulus or broad defect. We report 3 cases of trido mitral valve replacement using mechanical valve with its sewing ring expanded by a collar of Dacron sheet. The prosthetic sewing ring is anchored on the weak mitral annulus with multiple interrupted sutures, while the Dacron collar is contineuously sutured to the left atrial wall for blood tight sealing. All of the three cases showed event free postoperative course.
Cardiac papillary fibroelastomas are the second most common primary cardiac tumor. This tumor is usually benign and it involves the cardiac valve. However, most cardiac papillary fibroelastomas originate from a single site, and the incidence of cardiac papillary fibroelastomas originating from multiple sites is very rare (5%). A 55-year-old woman who presented with momentary dizziness and syncope was evaluated by performing echocardiography. Multiple tumors attached to the aortic valve were noted. The mass was removed freely without leaving any defect on the aortic valve leaflet. After the recovery period, the patient is currently being followed up at the outpatient department.
Since 1968 up to the end of October 1980, 448 valves were replaced in 354 patients in Seoul National University Hospital. There were 238 mitral, 38 aortic, 7 tricuspid, 45 aortic with mitral, 23 tricuspid with mitral, and 3 triple valve replacement aortic mitral and tricuspid cases. Annual increase of mitral valve replacement cases and decrease of operative maortality were remarkable. Recently operative mortality of mitral valve replacement is about 5%. Sex ratio of mitral valve replacement is almost equal and there were 12 cases of pediatric patients (5%) among 238 cases, and patients under the age of 20 years were 34 (14.3%). Mitral valve replacement was done for 199 single mitral, 38 double valve and one triple valve lesions. Among 238 mitral valve replacement paients left atrial thrombus in 23(9.7%), atrial fibrillation in 132 (55.5%), and reoperation after blind mitral commissurotomy in 12(5%) cases were noted. In recent cases bioprosthetic valves, mainly lonescu-shiley valve were utilized to overcome the difficulties of postoperative late complications in anticoagnuation, especially for the rural patients and pediatric cases, in addition to the hemodynamic advantages of lonesocu valve. Among 354 patients 16 cases were congenital heart anomaly related, 5 ventricular septal defect related aortic and 4 Ebstein related tribuspid valve replacement cases. There were 2 congenital anomaly related mitral valve replacements, one for congenital mitral insufficiency of 7 years old boy and one for corrected transposition of the great vessels associated with mitral insufficiency. Among total 354 valve replacements 49 operative deaths (13.3%) were noted and in 238 mitral valve replacement 24 operative deaths occurred (10.1%). In 39 patients among 354 total valve replacements late complications were found. In 238 mitral valve replacement cases late complications were noted in 26 patients, among whom 16 cases expired. Main late complications were thrombe-embolism, subacute becteerial endocarditis, arrythmia cerebral hemorrhage due to unsatisfactory anticoagulation, and congestive heart failure in the incipient period of valve replacement were also noted. In mitral valve replacement cases long-term survival rate was 83.2% who showed marked clinical improvement. Ther were no evidences of calcification during the 2 years follow-up period for the lonescu-valve replacement cases among 19 pediatric patients. In conclusion 238 cases of mitral valve replacement were done with 24 operative deaths and 26 late complication cases among whom 16 expired. The long term survival was 83.2% of the cases. In pediatric cases in place of coumadin anticoagulation Persantin **** 75 and aspirin were administered after valve replacement. In adult cases who have difficulaties with coumadin anticoagulation and for those even with bioprosthetic heart valve replacement who needs long-term or permanent anticoagulation persantin 75 and aspirin combination regimen were administered with antisfactory results.
From January 1962 to March 1987, 97 patients underwent operation for mitral valve disease. Of these patients, 61 [62.9%] required mitral valve replacement. Thirty-six patients [37.1%] had mitral valve repair. The mean age was 26.9*11.6 years [range 5 months to 48 years]. There were 32 [88.9%] cases of rheumatic valve disease, 4 [11.1%] cases of congenital mitral valve disease. Valve dysfunction was classified into three types: type I [normal leaflet motion], 6 patients; type II [prolapsed leaflet], 1 patient; type III [restricted leaflet motion], 29 patients. Twenty-nine patients [80.6%] had pure or predominant stenosis and 7[19.4%] had pure regurgitation. No patient was in NYHA functional class I. Three patients [16.7%] were in functional class II, 15[83.3%] were in functional class II. The techniques used included closed mitral commissurotomy [16 patients], open mitral commissurotomy [13 patients], localized Wooler type annuloplasty [4 patients], suture repair of leaflet defect [3 patients], chordal shortening [1 patient], Carpentier ring annuloplasty [1 patient], and fenestration of fused chordae [1 patient]. There were two perioperative deaths [5.6%], related to left ventricular failure and reoperation. The survivors were followed up for 94 patient-years [mean 4.68*5.54 years]. One late death [1.1*1.1% per patient-year] occurred and was valve related. Reoperation was required in 3 patients, of whom 2 were deaths. There was 1 case [1.1*1.1% per patient-year] of thromboembolism. No patient received anticoagulant after operation. At 10 year, 92*7.4% of the patients were still alive. The actuarial survival rate of patients free of valve-related complication was 79*6.4% at 6 years, 27*12.1% at 11 years. After surgery, 18 patients [88.9%] were in NYHA functional class I or II.
[1] and [2] present an approach to diagnosing possible defects in the mechanical systems of a nuclear power plant. In this paper, by using a fault library as a database and training data, we develop a diagnostic algorithm 1) to decide whether an Air Operated Valve system is sound or not and 2) to identify the defect from which an Air-Operated Valve system suffers, if any. This algorithm is composed of three stages: a neural net stage, a non-neural net stage, and an integration stage. The neural net stage is a simple perceptron, a pattern-recognition module, using a neural net. The non-neural net stage is a simple pattern-matching algorithm, which translates the degree of matching into a corresponding number. The integration stage collects each output and makes a decision. We present a simulation result and confirm that the developed algorithm works accurately, if the input matches one in the database.
Double mitral valve orifice is an unusual congenital abnormality, and is rarely of clinical importance. That abnormality not produce hemodynamic deficits, but it has been associated with other congenital heart diseases, especially atrioventricular canal defects, and so it is surgically important condition. After the first report by M.S. Greenfield in 1876, there are only a few reported cases all over the world. We experienced two cases of double mitral valve orifice with atrioventricular canal defect. The small accessory mitral orifice was placed in anterior mitral leaflet as a hole type in both cases. The A-V canal defects are corrected with a one patch technique, but the accessory orifices are left unclosed because there were no mitral regurgitations through the orifice. On the 4th postoperative day, the patients have been performed echocardiography; both had no mitral regurgitation. Both of patients are now being follow-up and we find no specific problems. A small accessory mitral orifice may be left unclosed and rarely produce significant regurgitation, conclusively.
Some tricuspid valve endocarditis can be controlled effectively with specific antibiotic treatment. However, surgical intervention Is necessary when there are continuing sepsis, moderate or severe heart failure, multiple pulmonary emboli, and echocardiographycally demonstrated vegitations. We are repoting a 19 year-old male patient who was admitted for the treatment of infective endocarditis. He previously had an operation for ventriculer septal defect (perimembranous type) about 9 years ago . An echocardiogram showed a large vegetation on the anterior cusp area and a left to right shunt through VSD, which was previously closed with dacron patch. A valve replacement in addition to antibiotic therapy was recommended for the patient. The patient underwent on operation : tricuspid valve replacement was done with 51. Jude medical valve prosthesis (33 mm), and in addition to above procedure, removal of vegetation and direct closure of VSD were done Postoperative echocardiogram showed that replaced tricuspid valve functioned well and vegeta ion and shunt flow were not observed. The patient recovered without complication and discharged at Postoperative day 25. Early aggressive surgical intervention is indicated to optimize surgical results, and this case seems to be a typical right sided bacterial endocarditis, which is caused by residual VSD. We are reporting a case of tricuspid valve endocarditis with a review of the literature. (Korean J Thorax Cardiovasc Surg 1996 ; 29: 440-3)
A safety valve has a valve mechanism for the automatic release of gas from piping system when the pressure exceeds preset limit cause of a defect of a pressure regulator, condensation of water in a pipe. Therefore, for the safety of pressure regulating station, it is essential to study the flow regime and characteristics of safety valve. This article presents the numerical analysis on the flow analysis, the ejection capacity and required effective discharge area of the safety valve that is established in pressure regulating station. Then, the results are compared and analyzed with domestic and foreign regulations such as API(America Petroleum Institute), EN(European Standard), and NF(Norme Francise). Moreover, the installation number of safety valve is considered by using domestic and foreign regulations and maximum reguired effective discharge area of safety valve.
Aorticopulmonary window is a rare anomaly among congenital heart disease. Various terms have been suggested including A-P window, A-P fenestration, fistula, aorticseptal defect etc. The defect lies usually between the left side of the ascending aorta and right wall of the pulmonary artery just anterior to the origin of the right main pulmonary artery. We have experienced one case of aorticopulmonary septal defect which was diagnosed as V5D with pulmonary hypertension in 1 4/12 year old, 7.2 Kg, male patient. Operation was done under the hypothermic cardiopulmonary bypass using 5t. Thomas cardioplegic solution. Vertical right ventriculotomy over the anterior wall of RVOT revealed no defect in the ventricular septum, and incision was extended up to the main pulmonary artery to find the source of massive regurgitation of blood through MPA. Finger tip compression of the aorticopulmanary window was replaced with Foley bag catheter balloon, and the $7{\times}10$ mm aorticoseptal defect located 15mm above the pulmonic valve was sutured continuously wih 3-0 nylon suture during azygos flow of cardiopulmonary cannula which was located distal to the window resulted massive air pumping systemically, and temporary reversal of pumping was tried to minimize cerebral air embolism. Remained procedure was done as usual, and pump off was smooth and uneventful. Postoperatively, patient was attacked frequent opistotonic seizure with no recovery sign mentally and p.hysically. Vital signs were gradually worsen with peripheral cyanosis and oliguria, and cardiac activity was arrested 1485 minutes after operation. Autopsy was performed to find the sutured window and massive edema of the brain.
Kim Woo-Shik;An Jae-Bum;Song Chang-Min;Kim Mi-Jung;Jung Sung-Chol;Shin Yong-Chul;Kim Byung-Yul;Kim In-Sub
Journal of Chest Surgery
/
v.39
no.8
s.265
/
pp.633-636
/
2006
The partial endocardial cushion defect including ostium primum atrial septal defect and anterior mitral leaflet cleft, presents less significant clinical symptoms than complete endocardial cushion defect. But, as mitral insufficiency develops, cardiomegaly, congestive heart failure, pulmonary arterial hypypertension appear. So, partial endocardial cushion defect has poor prognosis and is rarely seen in elderly patients. A 67 years old woman admitted at our hospital for operative treatment with partial endocardial cushion defect. She had increased pulmonary pressure of 45/22 mmHg, mean 32 mmHg. She had repair of ostium primum defect with patch, and the mitral valve was treated with valve replacement. Because advanced atrioventricular block developed postoperatively, she received permanent pacemaker.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.