• Title/Summary/Keyword: value position

Search Result 2,217, Processing Time 0.032 seconds

Estimation of p-values with Two Dimensional Null Distributions from Genomic Data Set

  • Yee, Jaeyong;Park, Mira
    • Journal of the Korean Data Analysis Society
    • /
    • v.20 no.6
    • /
    • pp.2711-2719
    • /
    • 2018
  • When an observable is described by a single value, the statistic significance may be estimated by construction of null distribution using permutation and counting the portion of it that exceeds the observed value by chance. Genome-wide association study usually focuses on the association measure between a single or interacting genotypes with a single phenotype. However investigation of common genotypes associated simultaneously on multiple phenotypes may involve the observables that should be described with multiple numbers. Statistical significance for such an observable would involve null distribution in multiple dimensions. In this study, extension of the p-value estimation process using null distribution in one dimension has been sought that may be applicable to two dimensional case. Comparison of the position of points within the set of points they form has been proposed to use a positioning parameter inspired by the extension of the Kolmogorov-Smirnov statistic to two dimensions.

Air Purification System Using Combined Wavelengths of Ultraviolet Light Sources (신경망을 이용한 BLE의 RSSI 예측 기법)

  • Youm, Sungkwan;Lee, Yujin;Shin, Kwang-Seong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.550-551
    • /
    • 2021
  • Positioning technology is performing important functions in augmented reality, smart factory, and autonomous driving. Among the positioning techniques, the positioning method using beacons has been considered a challenging task due to the deviation of the RSSI value. In this study, the position of a moving object is predicted by training a neural network that takes the RSSI value of the receiver as an input and the distance as the target value. To do this, the measured distance versus RSSI was collected.

  • PDF

Effects of Technical Barriers to Trade(TBT) and Sanitary and Phytosanitary Standards (SPS) on Korean Exports: Focusing on Global Value Chain (TBT와 SPS가 한국 수출에 미치는 영향: 글로벌 가치사슬을 중심으로)

  • Jihyun Eum
    • Korea Trade Review
    • /
    • v.46 no.6
    • /
    • pp.1-19
    • /
    • 2021
  • This paper examines the impact of sanitary and phytosanitary standards (SPS) and technical barriers to trade (TBT) on Korean exports, taking global value chains (GVC) participation into consideration. Using product-level import data from 2000 to 2014, we find heterogeneous effects of importers' SPS and TBT on Korean exports depending on the degree and position of GVC participation. According to the results, trade restrictive effects of SPS and TBT are smaller for industries that are more deeply involved in GVC. However, trade restrictive effects are greater for industries located at a relatively upstream production stage in GVC.

The Effect on Appendage muscle strength due to Increase in Occlusal Vertical Dimension (수직적 교합고경의 증가가 사지 근력에 미치는 영향에 관한 연구)

  • An, Su-Jin;Lee, Sung-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.231-244
    • /
    • 2001
  • This study was conducted to observe the effect on appendage muscle strength according to increase in occlusal vertical dimension. For this study, ten males with a mean age of 21 were selected. The subjects had a complete or almost complete set of natural teeth and reported no subjected symptoms of pain or dysfunction in the masticatory system. The tested occlusal splints were made at the position of increased occlusal vertical dimension of 2mm, 3.5mm, and 5mm from the ICP. Before and after wearing occlusal splints, the appendage muscle strength were tested by CybexII Dynamometer in each subject. The results were as follows : 1. When occlusal vertical dimension was increased, most of mean muscular strength values were increased except for those of supination and pronation of forearm at the position of 5mm increased occlusal vertical dimension. 2. The statistical analyses demonstrated that the increased occlusal vertical dimension position to be significantly stronger than intercuspal position for the muscle strength of the flexion and extension of hip, supination of forearm, external and internal rotation of knee, dorsiflexion and plantarflexion of ankle (p<0.05). 3. At the position of 3.5mm increased vertical dimension displayed the highest mean muscluar strength value than other positions. 4. Statistically demonstrated values, except for supination of forearm, internal rotation of shoulder, were related to lower appendage. Therefore splint was more effective on lower appendage than upper appendage to make muscle strength increased. 5. The mean increased rate of muscular strength tested on knee(57%), ankle(42%), and wrist(20%) were higher than hip(31%), elbow(14%), and shoulder(17%).

  • PDF

Evaluation of Surface Fatigue Degradation Using Acoustic Nonlinearity of Surface Wave (표면파의 음향비선형 특성을 이용한 표면 피로열화 평가)

  • Lee, Jae-Ik;Lee, Tae-Hun;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.415-420
    • /
    • 2009
  • This paper reports the results of a case study for the evaluation of surface damage by using acoustic nonlinearity of surface wave. In this study, the experimental system was constructed to measure the acoustic nonlinear parameter of surface wave in an Aluminum 6061 T6 specimen of which surface was damaged by the three point bending fatigue test, and magnitudes of nonlinear parameter measured before and after the fatigue test were compared. Especially, since the surface fatigue damage by the three point bending is concentrated at the central position of loading, the change in the nonlinear parameter around this position was monitored. Experimental results showed that the measured nonlinear parameter at the outside of this position after the fatigue test was almost same as the initial value before the fatigue test, since the fatigue damage at this position was little. However, clear increase in the nonlinear parameter was noticed after the fatigue test at the central position of specimen where the surface fatigue damage is expected to be concentrated.

Partial Discharge Position Tracking Method using a GIS Partial Discharge Signal and Arrival Time Difference (GIS 부분방전 신호와 도착 시간차 분석을 통한 PD발생 위치 추적)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1297-1301
    • /
    • 2013
  • This paper analyzes of PD occurrence position through an analysis of the arrival time difference between the GIS partial discharge signal. Because of GIS (Gas Insulated Switchgear) is a facility very important power equipment and as part of the equipment that make up the power system, the stabilization of the power industry, which accounted for 88.5% share of GIS substation in the form of a substation is an important equipment for power supply. In the situation where we are gradually expanding the need for preventive diagnosis in order to improve the efficiency of equipment management and failure prevention for Preventive diagnosis. In this paper as a method for extracting pre-defect of failure of GIS Apply the average value method of calculating the 5 times each using a pulse of the first time of the second pulse (${\Delta}t$) with an oscilloscope generation position PD(Partial Discharge). the results of GIS internal inspection, the partial discharge of the actual the position of the partial discharge was confirmed with an accuracy of about 82% of positions. Arrival time difference in the most effective manner if the partial discharge of GIS internal occurs by applying the averaging method and TOA(Time of arrival) method, the partial discharge occurs you through the measurement and analysis of PD signal occurs was confirmed in the experiment are presented and diagnostic methods location tracking.

A Study on the Position and Length of the Maxillary Central Incisor in Koreans (한국인의 상악중절치 위치 및 길이에 관한 연구)

  • Shin, Sang-Wan;Heo, Yun-Seok
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.5 no.1
    • /
    • pp.1-12
    • /
    • 1996
  • The arrangement of anterior artificial teeth is an important factor on the esthetics in the construction of complete dentures and prostheses. During construction of the complete denture the position of maxillary central incisor plays an important role in the arrangements of artificial teeth. The proper position of maxillary central incisor provides natural appearance of anterior teeth and the anterior reference point of occlusal plane. Many methods have been utilized to eatablish the position of the maxillary central incisor in complete denture prosthodontics. However, there has not been provided for the reference for Korean yet. This study was aimed to extablish a guide for the position of the maxillary central inciosr in Koreans. The horizontal and vertical distance between the maxillary central incisor and incisive papilla in Koreans were measured. 1. The mean value of horizontal distance from the maxillary central incisor to the incisive papilla had significant sexual difference, The average distance was 12.648mm in male and 11.385mm in female. 2. The horizontal distance of the incisive papilla had sexual difference, the average distance was 6.182mm in male and 5.622mm in female. 3. The vertical distance from the maxillary central incisor to the incisive papilla had not sexual difference, the average distance was 7.21mm. 4. The crown length of the maxillary central inciosrs from the distal interdental papilla had not sexual difference, the right central incisor was 6.40mm(mean) and the left central inciosr was 6.43mm(mean). 5. The clinical crown length of the maxillary central incisors had not sexual difference, the right central incisor 10.35mm(mean) and the left central incisor was 10.43mm(mean). 6. The shapes of the incisive papilla were pear(68.4%), oval(16%), triangular(6%), irregular(5%), rectangular(4%), and inverted pear(1%) shape.

  • PDF

A Study of High Precision Position Estimator Using GPS/INS Sensor Fusion (GPS/INS센서 융합을 이용한 고 정밀 위치 추정에 관한 연구)

  • Lee, Jeongwhan;Kim, Hansil
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.159-166
    • /
    • 2012
  • There are several ways such as GPS(Global Positioning System) and INS (Inertial Navigation System) to track the location of moving vehicle. The GPS has the advantages of having non-accumulative error even if it brings about errors. In order to obtain the position information, we need to receive at least 3 satellites information. But, the weak point is that GPS is not useful when the 혠 signal is weak or it is in the incommunicable region such as tunnel. In the case of INS, the information of the position and posture of mobile with several Hz~several hundreds Hz data speed is recorded for velocity, direction. INS shows a very precise navigational performance for a short period, but it has the disadvantage of increasing velocity components because of the accumulated error during integration over time. In this paper, sensor fusion algorithm is applied to both of INS and GPS for the position information to overcome the drawbacks. The proposed system gets an accurate position information from experiment using SVD in a non-accessible GPS terrain.

Development of a Precision BLDC Servo Position Controller for Composite Smoke Bomb Azimuth Driving System (복합연막탄 선회구동장치를 위한 정밀 BLDC 서보 위치 제어기 개발)

  • Koo, Bon-Min;Choi, Sung-Jin;Choi, Jung-Keyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.3
    • /
    • pp.467-472
    • /
    • 2006
  • This study has been done to design a precise system and develop position control algorithm to control a Composite Smoke Bomb Azimuth driving apparatus of a BLDC servo motor. Having to Blind the sight of opposite tank. the Smoke Bomb Rotational driving system needs instant response that is able to detect opponent appearance and blast the bomb at a short time. So a design that shows fast current response capability or $300[Hz]\sim500[Hz]$ is proposed. in the MIN-MAX PWM technology is used to increase the operational speed. in order to control the blasting position, a precision position control algorithm that utilizes the integral value of speed trajectory is suggested. Also these characteristics are monitored and assessed by the PC based monitoring program which shows the graphs of current, voltage, position, and speed parameters. The main controller is based on a TMS320VC33 high performance floating-point DSP(Digital Signal Process) and the PWM generator utilizes EPM7128 CPLD.

Effects of Modified Low-Dye Taping on Stroke Patients with an Excessive Pronated Foot (과도하게 엎침된 발을 가진 뇌졸중 환자에게 적용된 수정 발바닥활 지지 테이핑의 효과)

  • Kim, Hyun-Wook;Ryu, Young-Uk
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.2
    • /
    • pp.69-74
    • /
    • 2018
  • PURPOSE: Stroke patients may develop an over-pronated foot, resulting in a lower medial longitudinal arch. This can lead to a structural change of the foot due to deformation of the musculoskeletal system. The purpose of this study was to examine the effects of modified low-dye taping on stroke patients with an excessively pronated foot. The effect of the taping on the foot after light daily activity was also examined. METHODS: The subjects consisted of 21 stroke patients with an excessively pronated foot, as measured by the navicular drop test. First, their navicular heights were measured at a relaxed standing position (measure 1) and while standing in the subtalar neutral position (measure 2). Modified low-dye taping was applied to each subject's affected foot and the navicular height was then measured for the standing posture (measure 3). Finally, each subject walked around for 10 minutes and the navicular height was measured again (measure 4). RESULTS: Statistical analyses showed that the navicular height value at the relaxed standing position (measure 1) was significantly lower than for the other 3 measurements. That is, the modified low-dye taping was effective in maintaining a subtalar neutral position, even after a 10-minute walk, for stroke patients with an excessively pronated foot. CONCLUSION: The results suggest that modified low-dye taping applied to stroke patients with an excessively pronated foot could be an effective way to place the subtalar joint in a neutral position, and that its effect can be sustained for light daily activities.