• Title/Summary/Keyword: value contrast

Search Result 1,405, Processing Time 0.027 seconds

The Comparative Analysis Study and Usability Assessment of Fat Suppressed 3D T2* weighted Technique and Fat Suppressed 3D SPGR Technique when Examining MRI for Knee Joint Cartilage Assesment (슬관절 연골 평가를 위한 자기공명영상 검사 시 지방 신호 억제 3D T2* Weighted 기법과 지방 신호 억제 3D SPGR 기법의 비교 및 유용성 평가)

  • Kang, Sung-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.6
    • /
    • pp.219-225
    • /
    • 2016
  • In this study, for assessment of degenerative knee joint cartilage disease we acquired images by fat suppressed 3D spoiled gradient recalled (SPGR) and fat suppressed 3D $T2^*$ weighted imaging techniques. To do a quantitative evaluation, the knee joint cartilage was divided into medial femoral cartilage (MFC), medial tibial cartilage (MTC), lateral femoral cartilage (LFC), lateral femoral cartilage (LFC) and patella cartilage (Pat) to measure their respective signal intensity values, signal-to-noise ratio, and contrast-to-noise ratio. As for the measured values, statistical significance between two techniques was verified by using Mann-Whitney U-Test. To do a qualitative evaluation, two radiologists have examined images by techniques after which image artifact, cartilage surface, tissue contrast, and depiction of lesion distinguishing were evaluated based on 4-point scaling (1: bad, 2: appropriate, 3: good, 4: excellent), and based on the result, statistical significance was verified by using Kappa-value Test. 3.0T MR system and HD T/R 8ch knee array coil were used to acquire images. As a result of a quantitative analysis, based on SNR values measured by using two imaging techniques, MFC, LFC, LTC, and Pat showed statistical significance (p < 0.05), but MTC did not (p > 0.05). As a result of verifying statistical significance for measured CNR value, MFC, LFC, and Pat showed statistical significance (p < 0.05), while MTC and LTC did not show statistical significance (p > 0.05). As a result of a qualitative analysis, by comparing mean values for evaluated image items, 3D $T2^*$ weighted Image has indicated a slightly higher value. As for conformance verification between the two observers by using Kappa-value test, all evaluated items have indicated statistically significant results (p < 0.05). 3D $T2^*$ weighted technique holds a clinical value equal to or superior to 3D SPGR technique with respect to evaluating images, such as distinguishing knee joint cartilages, comparing nearby tissues contrast, and distinguishing lesions.

Evaluation of the Solitary Pulmonary Nodule by Spiral Computed Topography with Contrast Enhancement (고립성 폐결절의 감별에 있어서 나선형 흉부 전산화 단층촬영시 조영증강의 의의)

  • Song, Kwang Seon;Shin, Kye Chul;Yong, Suk Joong;Ryu, Jeong Seon;Kang, Sin Goo;Kim, Chong Ju;Sung, Ki Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.519-526
    • /
    • 1996
  • Background : Clinical and Radiographic studies to differentiate benign from malignant pulmonary nodules have previously focused on clinical status and the morphologic and the computed tomographic attenuation characteristics of the lung nodules. Distinctive differences in the vascularity and pathophysiology of malignant versus benign pulmonary nodules were identified. We evaluated the diagnostic method for differentiating malignant from benign solitary pulmonary nodule by contrast enhancement on the spiral CT. Method : Sixteen patients with solitary pulmonary nodule were examined(Tuberculoma 8, primary lung cancer 8). Serial thin section on the spiral CT was performed before and after(45second, 2min, 5min) the onset of the injection of 100mL of nonionic contrast material(2mL/sec). Results : There was no difference in size of nodule and pre-contrast CT number (Hounsfield unit) between benign and malignant nodules. At forty-five second after the onset of the injection, malignant neoplasms($19.6{\pm}7.9$ HU) enhanced significantly more than tuberculomas($4.9{\pm}9.4$ HU, p=0.008). At 2minute and 5 minute after, malignant neoplasms($34.0{\pm}19.2$HU, $34.0{\pm}15.4$HU) enhanced significantly more than tuberculomas ($6.7{\pm}9.7$HU, p=0.007 and $7.7{\pm}11.5$HU, p=0.011). On cut-off value 20HU(contrast enhancement) 2minute after the injection of contrast media, sensitivity was 87% and specificity was 87%. No correlation between the contrast enhancement and size of the nodules was observed. Conclusion : Studies with the use of an intravenously administered noniodinated contrast medium in examining the enhancement properties of lung nodules was performed. The contrast enhancement was useful in differential diagnosis of solitary pulmonary nodules.

  • PDF

Usefulness of Low Dose Oral Contrast Media in $^{18}F-FDG$ PET/CT ($^{18}F-FDG$ PET/CT에서 저용량 경구용 조영제의 유용성)

  • An Young-Sil;Yoon Joon-Kee;Hong Seon Pyo;Joh Chul-Woo;Yoon Seok-Nam
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.257-262
    • /
    • 2006
  • Purpose: The standard protocol using large volume of oral contrast media may cause gastrointestinal discomfort and contrast-related artifacts in PET/CT. The aim of this study was to evaluate the usefulness of low dose oral contrast in $^{18}F-FDG$ PET/CT. Materials and Methods: We retrospectively reviewed the whole-body PET/CT images in a total of 435 patients. About 200 ml of oval contrast agent (barium sulfate) was administered immediately before injection of $^{18}F-FDG$. The FDG uptake of intestines was analyzed by visual and semi- quantitative method on transaxial, coronal and saggital planes. Results: Seventy (16%, 113 sites) of 435 images showed high FDG uptake (peak SUV > 4); 50 (74%, 84 sites) with diffuse and 20 (15%, 29 sites) with focal uptake. The most commonly delivered site of oral contrast media was small bowel (n=27, 39%). On PET/CT images, FDG uptake coexisted with oral contrast media in 26 patients (54%, 38 sites) with diffuse pattern and 9 (45%, 9 sites) with focal pattern, and by sites, those were 38 (45%) and 9 (31%), respectively. In small bowel regions, the proportion of coexistence reached as high as 61% (29/47 sites). A visual analysis of available non-attenuation corrected PET images of 27 matched regions revealed no contrast-related artifact. Conclusion: We concluded that the application of low dose contrast media could be helpful in the evaluation of abdominal uptake in the FDG PET/CT image.

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.

A High-performance Lane Recognition Algorithm Using Word Descriptors and A Selective Hough Transform Algorithm with Four-channel ROI (다중 ROI에서 영상 화질 표준화 및 선택적 허프 변환 알고리즘을 통한 고성능의 차선 인식 알고리즘)

  • Cho, Jae-Hyun;Jang, Young-Min;Cho, Sang-Bok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.148-161
    • /
    • 2015
  • The examples that used camera in the vehicle is increasing with the growth of the automotive market, and the importance of the image processing technique is expanding. In particular, the Lane Departure Warning System (LDWS) and related technologies are under development in various fields. In this paper, in order to improve the lane recognition rate more than the conventional method, we extract a Normalized Luminance Descriptor value and a Normalized Contrast Descriptor value, and adjust image gamma values to modulate Normalized Image Quality by using the correlation between the extracted two values. Then, we apply the Hough transform using the optimized accumulator cells to the four-channel ROI. The proposed algorithm was verified in 27 frame/sec and $640{\times}480$ resolution. As a result, Lane recognition rate was higher than the average 97% in day, night, and late-night road environments. The proposed method also shows successful lane recognition in sections with curves or many lane boundary.

Effect of the Water Extract of Cultured Wild Ginseng on the Acute and Subacute Toxicities Induced by Doxorubicin in Mice (산양산삼이 Doxorubicin의 급성 및 아급성 독성에 미치는 영향)

  • Lee, Hyun-Ju;An, Dea-Young;Kim, Ho-Hyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.1025-1034
    • /
    • 2009
  • This study was carried out to examine the protective effect of Cultured Wild Ginseng(CWG) on the acute and subacute toxicities induced by doxorubicin(Doxo) in mice. Heart and liver weight was decreased following Doxo administration. In contrast, such a decrease was significantly attenuated by CWG administration. The value of serum CPK in Doxo group was increased compared with normal group. But the value of CWG group were decreased significantly compared with the values of Doxo group in the liver of the Doxo group, cloudy swelling of hepatic cells and narrowing of sinusoids were observed. Whereas in the CWG group, well oriented hepatic cell cords and sinusoids were observed. In the testis of the Doxo group, necrotic and degenerative changes of the seminiferous tubules, especially beneath testicular membrane were observed. But those lesions were alleviated in CWG group. Cross sectional area of testis and diameter of semineferous tubule were significantly increased in CWG group compared with Doxo group. Body weight was reduced in Doxo group compared with normal group. In contrast, such a decrease was significantly attenuated by CWG administration atwa5th day. Spermatogenetic cells in seminiferous tubules were necrotic and desquamated and the cellularity of seminiferous epithelia was reduced in Doxo group. But those lesions were attenuated by CWG administration. Cross sectional area of testis and diameter of seminiferous tubule were significantly increased in CWG group compared with Doxo group. In addition, the increase in lipid peroxidation(LPO) in testis was inaddition, the, iout such a increased was significantly inhibited in CWG group. BrdU labelled cells in the seminiferous tubules were remarkably decreased in Doxo group. Whereas the number of seminiferous tubules labelled with BrdU in spermatogonia was increased by CWG administration. The obtained results suggest that CWG has protective effect on doxorubicin-induced toxicity. This effect might be mediated through the supplementation of vital energy.

Usefulness of New GAGG Scintillation Detector for Gamma Camera : A Monte Carlo Simulation Study (GAGG 섬광체 물질을 적용한 감마카메라 영상의 유용성 평가: 몬테카를로 시뮬레이션 연구)

  • Kim, Jung-Soo;Park, Chan Rok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.511-515
    • /
    • 2020
  • In this study, we evaluated image quality for new Gadolinium Aluminum Gallium Garnet (GAGG) scintillation material based on the Geant4 Application for Tomographic Emission (GATE) simulation tool. The gamma camera detectors with GAGG and NaI scintillation were designed. In particular, we modeled modified body phantom by National Electrical Manufacturers Association International Electrotechnical Commission to evaluate the simulated images. To analysis the image performance, the contrast to noise ratio (CNR) and coefficient of variation (COV) were used by drawn the region of interests, respectively. Based on the CNR and COV results, the CNR value for GAGG material is higher approximately 17 % than NaI material. In addition, the COV value for GAGG material is lower approximately 17 % than NaI material. In conclusion, we confirmed the performnace of GAGG based gamma camera is useful to improve the image quality for the nuclear medicine instrumentation.

Analysis of Attenuation Differences According to Radiolucent and Radiopague Materials : Based on DECT (Dual Energy Computed Tomography) (방사선 투과 및 불투과성 물질에 따른 감약 차이의 분석 : DECT 검사 중심으로)

  • Jang, Hyon-Chol;Kim, Yoon-Shin;Kim, Hyeon-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1584-1589
    • /
    • 2014
  • This study analyzed CT values of radiolucent and radiopaque materials by energy region after selecting radiolucent and radiopaque materials at random using GE's DECT((Dual Energy Com-puted Tomography) at S University Hospital located in Gyeonggi-province from July through August in 2013. Besides, it drew out the most analogous energy region to the value of 120kVp CT, which is applied to existing SECT(Single Energy Computed Tomography), by utilizing the analysis method of CT values and tried to find out the most useful and appropriate materials when contrast was applied within visible area in clinical application. As a result, there was little decrease of CT value after 90KeV in the case of materials with low density and high moisture content such as normal saline, methyl-cellulose and gels used in ultra-sonic waves test; energy does not influence much on materials with extremely low or high density such as air and contrast medium; methyl-cellulose and gels used in ultra-sonic waves test are considered to be the most useful materials for clinical applications.

Incidence of Venous Thromboembolism in Pelvic and Acetabular Fractures in the Korean Population (한국인의 골반과 비구 골절에서 정맥 혈전색전증의 발병률)

  • Lee, Sang Ki;Lee, Jae Won;Hwang, Jung Joo
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.74-80
    • /
    • 2013
  • Purpose: There are no detailed reports on the incidence of venous thromboembolism (VTE) in pelvic and acetabular fractures in the Asian population. The purpose of this study was to investigate the incidence of VTE in pelvic and acetabular fractures in the Korean population. Methods: The cases of 67 Korean patients with pelvic and acetabular fractures treated at our hospital from January 2009 to February 2012 were analyzed retrospectively. Until May 2010, VTE screening was performed by contrast-enhanced computed tomography (CT) or ultrasonography (US) when the D-dimer value did not decline predictably, still exceeded $20{\mu}g/ml$ at 5 days after trauma and surgery, or increased to greater than $20{\mu}g/ml$ after a period of decline. After May 2010, contrast-enhanced CT and US were performed routinely irrespective of the D-dimer value. Physical prophylaxis was performed on all patients. The effects of the presence of a pelvic and/or acetabular fracture, and the effects of fracture type, accompanying injuries, and screening strategies on the incidences of VTE were investigated. Results: Overall, 26 patients(38.8%) were diagnosed with VTE and PTE in 14(20.9%). All were asymptomatic. Significantly higher incidences of VTE and PTE were observed in trauma patients with pelvic and acetabular fractures than in trauma patients without pelvic and acetabula fractures treated during the same period. No significant differences were observed in the incidences of VTE and PTE between patients with pelvic fractures, and patients with acetabular fractures or between patients with and without accompanying injuries. Compared with the previous screening strategy, the detection rates for VTE and PTE were higher for the newer screening strategy; however, the difference did not reach statistical significance. Conclusion: In the Korean population, we should be vigilant for a high incidence of VTE, especially PTE, in patients with pelvic and acetabular fractures.

Noninvasive Biomarker for Predicting Treatment Response to Concurrent Chemoradiotherapy in Patients with Hepatocellular Carcinoma

  • Chung, Yong Eun;Park, Jun Yong;Choi, Jin-Young;Kim, Myeong-Jin;Park, Mi-suk;Seong, Jinsil
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.4
    • /
    • pp.351-360
    • /
    • 2019
  • Purpose: To investigate noninvasive biomarkers for predicting treatment response in patients with locally advanced HCC who underwent concurrent chemoradiotherapy (CCRTx). Materials and Methods: Thirty patients (55.5 ± 10.2 years old, M:F = 24:6) who underwent CCRTx due to advanced HCC were enrolled. Contrast-enhanced US (CEUS) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) were obtained before and immediately after CCRTx. The third CEUS was obtained at one month after CCRTx was completed. Response was assessed at three months after CCRTx based on RECIST 1.1. Quantitative imaging biomarkers measured with CEUS and MRI were compared between groups. A cutoff value was calculated with ROC analysis. Overall survival (OS) was compared by the Breslow method. Results: Twenty-five patients were categorized into the non-progression group and five patients were categorized into the progression group. Peak enhancement of the first CEUS before CCRTx (PE1) was significantly lower in the non-progression group (median, 18.6%; IQR, 20.9%) than that in the progression group (median, 59.1%; IQR, 13.5%; P = 0.002). There was no significant difference in other quantitative biomarkers between the two groups. On ROC analysis, with a cutoff value of 42.6% in PE1, the non-progression group was diagnosed with a sensitivity of 90.9% and a specificity of 100%. OS was also significantly longer in patients with PE1 < 42.6% (P = 0.014). Conclusion: Early treatment response and OS could be predicted by PE on CEUS before CCRTx in patients with HCC.