• 제목/요약/키워드: value contrast

검색결과 1,405건 처리시간 0.033초

Equity Financing for Innovation and Firm Value: International Evidence

  • Jin-Young Yang
    • 아태비즈니스연구
    • /
    • 제14권4호
    • /
    • pp.23-36
    • /
    • 2023
  • Purpose - This study investigates the impact of equity financing on the valuation of R&D investments using a sample of firms from 33 countries from 1997 to 2018. Design/methodology/approach - I use a modified version of the valuation regression widely used in the literature. Findings - I find evidence that R&D investments are more highly valued when financed through equity. In contrast, debt financing does not affect the valuation of R&D investments. I also document that the impact of equity financing on R&D investment valuation weakens during the financial crisis. Research implications or Originality - In light of the distinctive characteristics of innovative investment, previous research investigates its relationship with financing. What remains unexamined, however, is how financing choices impact the way investors value innovative investments. This study seeks to bridge this gap in the existing body of research using a sample of firms from 33 countries from 1997 to 2018, for 22 years.

요로결석 환자의 경정맥 요로조영 검사 시 압박 유무에 따른 영상평가 (Image Measurement on Influence from Application of Compression Band on Intravenous Urography for Urolithiasis Patient)

  • 김형균;홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.261-266
    • /
    • 2015
  • 요로결석으로 인한 경정맥 요로조영 검사는 방사선 비 투과성 물질인 요오드 조영제를 사용하여 요관의 경로에 있는 결석을 진단하는 방사선학적 검사법이다. 그 검사 방법 중 엉덩뼈 능선 상단에 대한 압박으로, 조영제가 방광으로 배출되는 것을 막아, 상부요로의 묘출을 용이하게 하는 압박대 사용 유무는 병원마다 다른 방법을 적용하고 있다. 연구자들은 실험을 통하여 압박 과 압박을 하지 않은 상태에서 조영제 진행의 특이도를 관찰하여 상호 비교하고자 하였다. 본 연구는 조영제의 종류, 용량, 검사진행 기준이 동일한 일 병원에서 실시한 경정맥 요로조영 검사 60 례를 후향적 영상평가 방법으로 실시하였다. 영상평가는 5 분 영상으로 제한하여 압박 유무에 대한 조영제의 해부학적 주행 위치가 용이한 시간대로 하였으며, 콩팥 피라미드에서 콩팥깔때기까지를 "RP", 콩팥깔때기에서 요추 3 번째 종판까지를 "PL", 양쪽 엉덩뼈 능선을 기준으로 상부와 하부를 "IU"와 "IL"으로 해부학적 영역을 설정하였다. 분석방법은 피셔의 정확 검정에 의한 통계적 방법으로 압박과 압박을 하지 않은 상태에서 해부학적 위치의 분포차이가 있는지를 분석하였다. 압박그룹과 압박을 하지 않은 그룹 각 30 례의 영상평가에서 P 값이 왼쪽 0.580, 오른쪽 0.711, 양쪽에서 0.960 등으로 나타나 통계적으로 유의한 분포의 차이가 없음을 확인하였다. 이로서 요로결석 환자의 경 정맥 요로조영 검사 시 압박 대 사용유무는 조영제 진행에 차이를 주지 않는다는 통계적 결론을 얻었다.

뇌영역의 동적 자화율 대조도 영상에서 Gd-DTPA 조영제의 비투과성 조사: 새로운 비선형 곡선조화 알고리즘 개발의 예비연구 (Assessment of Non-permeability of Gd-DTPA for Dynamic Susceptibility Contrast in Human Brain: A Preliminary Study Using Non-linear Curve Fitting)

  • 윤성익;장건호;강현수;김영주;최보영
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권2호
    • /
    • pp.103-109
    • /
    • 2007
  • 목적: 정상인의 뇌영역의 동적 자화율 대조도 (dynamic susceptibility contrast)에서 새로운 비선형 곡선조화 알고리즘을 사용한 Gd-DTPA의 비투과성 (non-permeability)을 조사하고자 한다. 대상 및 방법: 전반적인 혈관내의 이동에 대한 전달함수($K^{trans}$)에 대하여 첫 번째 통과된 조합변수인자의 화소에 대한 정량적인 분석을 실시하였다. 정확한 복셀값의 산출을 위하여 개선된 알고리즘에 의한 경계값을 적용하여 최적화 과정을 반복수행하였다. 결과: 비선형 곡선조화 알고리즘을 적용함으로서, 뇌혈류와 뇌혈류량 측정은 $T2^*$-강조 dynamic contrast enhanced (DCE)에서 상당히 개선 되었다. 재산출된 인자들로부터 뇌관류 강조영상의 형성은 수정된 비선형 곡선조화 알고리즘을 사용하여 획득하였다. 가상공간의 계산과 데이터 입력은 $T2^*$-강조 DCE 영상에서 조영제 포화도를 산출하였다. 결론: 본 연구에서 개발한 새로운 비선형 곡선조화 알고리즘을 사용하여 DCE-$T2^*$ 강조 자기공명영상 데이터를 얻은 후에 역동학적 인자들의 정확성 및 효율성을 개선시키는데 도움을 주는 것으로 확인되었다.

  • PDF

Brain Angiography 검사 시 Scan Time에 따른 Contrast Media Volume에 대한 연구 (Study on the Contrast Media Volume according to Scan Time during Brain Angiography Examination)

  • 이주련;김동현
    • 한국방사선학회논문지
    • /
    • 제15권1호
    • /
    • pp.29-35
    • /
    • 2021
  • 본 연구의 목적은 주기적으로 follow up CT를 촬영하는 뇌출혈 환자에게 조영제의 양을 줄임으로써 줄이기 전과 후의 영상의 화질의 차이가 있는지에 관하여 조사하는 것이었고, 줄이기 전과 후의 영상을 검사한 후 MMWP 프로그램을 이용하여 각각의 혈관 위치에 ROI를 설정하여 화질을 평가하였다. 먼저 Rt. CCA, Lt.CCA. Rt.MCA, Lt.MCA, Basilar artery에 각각 ROI를 잡았다. 둘째, 잡은 ROI에 대한 평균값과 표준편차값을 구하였다. 셋째, 구해진 평균값과 표준편차 값을 통하여 SNR과 CNR을 구하였다. 구하여진 SNR값과 CNR값을 T-test 통계를 구한 결과 SNR에 대한 결과 값은 Rt.CCA 0.765, Lt.CCA 0.871, Rt.MCA 0.343, Lt.MCA 0.235, Basilar artery 0.916이며, CNR에 대한 결과 값은 Rt.CCA 0.088, Lt.CCA 0.069, Rt.MCA 0.818, Lt.. MCA 0.579, Basilar artery 0.878로 나타났다. 구해진 SNR값과 CNR값을 통하여 통계를 구한 결과값이 조영제를 줄이기 전과 후의 영상의 화질에 차이가 없는 것으로 나타났다. 따라서 본 연구가 주기적으로 CT검사를 하는 환자들에게 조영제에 대한 부담이 덜어질 수 있는 지표가 되기를 바랍니다.

영상 정보 손실을 최소화하는 방사선 차폐체 연구 (Radiation Shielding to Minimize Image Information Loss)

  • 장수한;박상현;주명식
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.449-457
    • /
    • 2023
  • 방사선 감수성이 높은 부위의 방사선 검사 시 피폭선량 감소를 위해 사용하는 차폐체가 조사야에 포함될 경우 방사선 영상에서 밝게 표현되며 영상 정보의 손실이 발생한다. 영상 정보의 손실은 진단과 치료에 제한점을 주며 재촬영이 필요할 경우, 불필요한 방사선에 노출될 수 있다. 본 논문에서는 수용성 요오드 조영제와 물을 혼합한 다양한 농도의 차폐체를 제작하여 영상 손실을 최소화하면서 기존 차폐체와 동등한 차폐 효과를 발생하는 방사성 방호 차폐체를 연구하고자 하였다. 차폐체는 물 100 ml, 수용성 요오드 조영제 100 ml, 수용성 요오드 조영제와 물을 20 : 80, 40 : 60, 60 : 40, 80 : 20 비율로 각각 100 ml를 제작했다. 차폐 효율을 측정하기 위해서 차폐체를 가로 9.5 cm, 세로 9.5cm의 플라스틱 용기에 약 1.5 cm 높이로 담고 흡수선량 감쇠율을 평가하였다. 조사 조건은 골반 촬영 조건을 기준으로 5회 반복 측정하였고 측정한 조사선량 값을 흡수선량 값으로 변환한 뒤 평균값을 산출 비교하였다. 영상 정보 손실 정도는 팬텀의 골반강 부위를 차폐하고 획득한 영상을 근골격 전문의 2명과 방사선사 8명이 주요 해부학적 구조물의 관찰 정도를 평가 후 선택하였다. 또한 차폐한 부위의 영상에서 표현되는 골격과 가스의 신호 강도 차이를 분석한 결과 방사선 감쇠 효율성은 수용성 요오드 조영제의 비율이 높을수록 높은 차폐 효율을 나타냈다. 영상 정보의 손실 평가에서 평가자들은 수용성 요오드 조영제 20 ml 혼합물에서 해부학적 구조물의 관찰이 용이하다 평가하였으며 60 ml 이상의 혼합물에서는 구조물의 관찰이 불가능하였다. 골격과 가스의 신호강도 차이는 p < 0.001로 평균값의 차이가 유의미한 차이가 있었으며, 조영제의 농도가 높을수록 신호 강도의 차이는 적었다. 수용성 요오드 조영제 차폐체는 방사선 감쇠 효율이 기존의 차폐체 보다 떨어지지만, 차폐체가 관찰하는 목적부위 이거나 가까이 위치하여 차폐체를 적용하지 못하는 경우에 사용한다면, 영상 손실을 최소화하며 보다 더 적극적인 방사선 방호의 역할을 수행할 수 있다.

소비가치 이론에 의한 병원선택 요인 연구 (A Study of Hospital Choice on the Basis of Consumption Values Theory)

  • 이선희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권2호
    • /
    • pp.413-427
    • /
    • 1997
  • This research is based on the Consumption Values Theory proposed by Sheth(1991). The purpose of this research is finding the factors related to the process of hospital choice. The expectation of six hospital outpatients 600 was analyzed by six consumption values categories: functional value, social value, emotional value, rarity value, condition value, health related values. The main results of this research is as following; 1. In the result of factor analysis 22 consumption value factors which affect the hospital preference were extracted; kindness/clearness, service speed, comfort of space, technical competence in functional values, high income/active social life, low income/blue collar unmarried/man, middle aged/big family, woman/married, introvert in social values, high-class, comfort, reliability in emotional value, newness, classiness in rarity value, social relationship, close to residence, social reputation in conditional values, priority on health, health behavior, active sense of value on health in health related values. 2. The difference of consumption values among hospital types were analyzed. The critical factors in reference for corporate hospitals newly established were kindness/clearness, service speed, convenience, classiness, comfort, and newness. University hospitals were preferred by the factors of reliability, and social reputation. In general hospital, convenience and close to residence were critical factor. 3. In logistic regression, age, marital status, education level and income as socio-demographic variables were significantly related to general hospital choice. Also service speed and close to residence were positively and high income/active social life and high class value were negatively related to general hospital choice. On university hospital choice, age and marital status, education show posive relationship whereas income showing negative relationship. Kindness/clearness, service speed, comfort of space, unmarried/man, comfortable feeling, newness and close to residence showed negative relationship with university hospital selection whereas technical competence, reliability in emotional value, classiness in rarity value, social relationship in functional values showed positive relationship. Lastly kindness/clearness, comfort of space, high income/active social life, unmarried/man, high-class, comfort and newness were positively related to corporate hospitals newly established choice in contrast to negative relationship in reliability in emotional value and classiness. In summary, we found that hospital user also choose to hospital in base of various consumption value. Further studies to investigate the hospital consumer behavior will be needed.

  • PDF

히스토그램 분할과 가중치에 기반한 영상 콘트라스트 향상 방법 (Image Contrast Enhancement based on Histogram Decomposition and Weighting)

  • 김매리;정민교
    • 인터넷정보학회논문지
    • /
    • 제10권3호
    • /
    • pp.173-185
    • /
    • 2009
  • 본 논문에서는 두 가지 영상 콘트라스트 향상 기법인 RSWHE (Recursively Separated and Weighted Histogram Equalization)와 RSWHS (Recursively Separated and Weighted Histogram Specification)를 새롭게 제안한다. RSWHE는 히스토그램 평활화 방법에 히스토그램 분할과 가중치 개념을 적용하였고, RSWHS는 히스토그램 명세화 방법에 히스토그램 분할과 가중치 개념을 적용하였다. 제안 방법은 1) 입력 영상의 평균 명도 값을 기준으로 히스토그램을 분할하고, 2) 분할된 각 서브히스토그램(sub-histogram)이 차지하는 확률밀도 값을 계산하며, 3) 계산된 확률밀도 값을 가중치로 사용하여 각 서브히스토그램을 변형한 후, 4) 변형된 각 서브히스토그램을 독립적으로 평활화 하거나 (RSWHE 방법인 경우) 또는 명세화 하게 (RSWHS 방법인 경우) 된다. 다양한 영상에 대한 실험을 통하여, 제안하는 두 방법이 기존의 다른 방법들에 비하여 콘트라스트 향상과 평균 명도 보존 측면에서 우수한 성능을 나타냄을 알 수 있었다.

  • PDF

PET/CT에서 Phantom을 이용한 Fluorine-18, Gallium-68 방사성 핵종의 PET 영상 평가 (Evaluation of PET Image for Fluorine-18 and Gallium-68 using Phantom in PET/CT)

  • 윤석환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권4호
    • /
    • pp.321-327
    • /
    • 2018
  • The purpose of this study is to compare PET imaging performance with Fluorine-18 ($^{18}F$) and Gallium-68 ($^{68}Ga$) for influence of physical properties of PET tracer. Measurement were performed on a Siemens Biograph mCT64 PET/CT scanner using NEMA IEC body phantom and Flangeless Esser PET phantom containing filled with $^{18}F$ and $^{68}Ga$. Emission scan duration(ESD) was set to 1, 2, 3, 4 and 5min/bed for $^{68}Ga$ and 1min/bed for $^{18}F$. The PET image were evaluated in terms of contrast, spatial resolution. Under same condition, The percentage of contrast recovery measured in the phantom ranged from 16.88% to 72.56% for $^{68}Ga$ and from 27.51% to 74.43% for $^{18}F$ and The FWHM value to evaluate spatial resolution was 10.96 mm for $^{68}Ga$ and 9.19 mm for $^{18}F$. For this study, $^{18}F$ produces better image contrast and spatial resolution than $^{68}Ga$ due to higher positron yield and lower positron energy ($^{18}F$: 96.86%, 633.5 keV, $^{68}Ga$: 88.9%, 1899 keV), The physical properties of PET tracer effect on the PET image. $^{68}Ga$ image applying ESD of 3, 4, 5min/bed were showed similar to $^{18}F$ image with ESD of 1min/bed. This study suggests that increasing ESD for acquiring $^{68}Ga$ PET image seem to be similar to $^{18}F$ image.

4차원 영상기법 Time Resolved Imaging of Contrast Kinetics MRA의 유용성 (Four Dimension(4D) Time Resolved Imaging of Contrast Kinetics(TRICKS) MR Angiography)

  • 임청환;배성진
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.1105-1110
    • /
    • 2009
  • Time Resolved Imaging of Contrast Kinetics 기법을 이용한 4차원 자기공명혈관조영술(TRICKS -MRA)영상과 기존 TOF-MRA영상을 비교하여 임상적 유용성에 대해 알아보고자 하였다. 총 17명 중 뇌 혈관 질환이 의심되는 11명과 뇌 종양을 의심하는 6명을 대상으로 TOF-MRA와 TRICKS -MRA을 시행한 후 17대상자 중 11명에서 DSA를 추가적으로 시행하였다. TOF-MRA는 공간해상력보다 시간해상력이 부족하였고, TRICKS-MRA에서는 TOF-MRA보다 공간분해능은 부족한 점이 많지만 영상판독에 큰 영향은 없었고 모든 대상자에서 동맥과 정맥의 구별이 가능하여 시간분해능이 우수 한 것을 나타났다. 또한 종양과 혈관과의 관계성 평가에서 TOF-MRA보다 좋은 것으로 나타났다. TRICKS-MRA방법은 시간대별로 동맥, 모세혈관, 정맥기를 신속하면서 쉽게 4차원적으로 영상화가 가능하여 앞으로 임상에서 이용도가 더욱 증가 할 것으로 사료된다.

  • PDF

히스토그램 변형을 이용한 HDR 영상 렌더링을 위한 인지기반 톤 맵핑 기법 (Perception-Based Tone Mapping Technique for Rendering HDR Image Using Histogram Modification)

  • 김원균;하창우;정제창
    • 한국통신학회논문지
    • /
    • 제38A권11호
    • /
    • pp.919-927
    • /
    • 2013
  • 본 논문에서는 HDR (high dynamic range) 영상 렌더링을 위한 히스토그램 변형 기법을 이용한 인지기반 톤 맵핑(tone mapping) 기법을 제안한다. HDR 톤 맵핑 알고리듬은 넓은 동적 영역을 갖는 영상을 LDR (low dynamic range) 영상 장치에 표현하기 위해 사용된다. 인간의 시각특성을 이용한 톤 맵핑 알고리듬은 상당히 효과적이지만 고정된 형태의 맵핑 함수를 사용하기 때문에 모든 영상에서 동일한 성능을 얻지 못한다. 제안하는 방법은 인지기반 톤 맵핑 함수와 히스토그램 변형기법을 적용하여 HDR 영상의 동적 영역을 압축한다. 인지기반 톤 맵핑 함수를 이용해서 원 영상의 히스토그램을 제한하고 보상과정을 통해서 적응적인 톤 맵핑 함수를 얻을 수 있다. 이는 화소값에 따라 서로 다른 제약조건들을 사용함으로써 contrast를 향상시킬 뿐만 아니라 원 영상의 디테일도 보존한다. 또한, 히스토그램 변형기법을 사용함으로써 과도한 히스토그램 평활화로 인한 왜곡을 개선할 수 있고, 더욱이 제어파라미터를 이용하여 영상의 contrast를 조정할 수 있다. 시뮬레이션 및 실험을 통해 주관적 및 객관적 성능을 비교하고 기존 방법에 비해 제안한 방법이 우수함을 입증한다.