• Title/Summary/Keyword: validation study

Search Result 4,757, Processing Time 0.034 seconds

Comparative Study for the Validation of TPNSim++ and its Applicability to Military Simulation (TPNSim++의 검증 및 군사 시뮬레이션 분야의 활용성)

  • 최상영;김대운
    • Journal of the military operations research society of Korea
    • /
    • v.23 no.2
    • /
    • pp.1-14
    • /
    • 1997
  • TPNSim++ is the object-oriented framework for the discrete event simulation of military systems, developed by authors. The simulation world view of TPNSim++ is on the basis of activity scanning. TPNSim++ is implemented as C++ class library under Windows 95/NT. It uses the extended timed Petri nets which are called TPNSim nets for simulation modeling tool. The aim of this study is to conduct a comparative study of TPNSim++ and SLAM II in the simulation of military maintenance systems for the validation and the applicability of TPNSim++. From this study, TPNSim++ and SLAMII have given the same results under the equivalent assumption. Thus we can get the validation of TPNSim++ and its applicability to the simulation of maintenance systems.

  • PDF

Development and Validation of the Hospice Palliative Care Performance Scale (호스피스완화의료서비스 성과평가 도구개발)

  • Kwon, So-Hi
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.3
    • /
    • pp.374-381
    • /
    • 2011
  • Purpose: The purpose of this study was to develop and validate a hospice palliative care performance measure which would cover more than just physical symptoms or quality of life. Methods: Through an intensive literature review, the author chose questions that measured aspects of physical, emotional, spiritual, social, or practical domains pertinent to hospice palliative care for inclusion in the scale. Content validation of the questions was established by 15 hospice palliative care professionals. A preliminary Hospice Palliative Care Performance Scale (HPCPS) of 20 questions was administered to 134 pairs of terminal cancer patients from 5 hospice palliative care units and their main family caregiver. A validation study was conducted to evaluate construct validity and internal consistency. Results: Factor analysis showed 14 significant questions in five subscales; Physical, Emotional, Spiritual, Social, and Patient' rights. There were no significant differences between the ratings by patients and family members except for three out of the 14 questions. The measure demonstrated construct validity, and Cronbach's ${\alpha}$ of the subscales ranged from .73 to .79. Conclusion: The HPCOS demonstrated acceptable validity and reliability. It can be used to assess effectiveness of hospice palliative care for terminal cancer patients in practice and research.

Study on Improvement of Calibration/Validation of SWAT for Spatio-Temporal Analysis of Land Uses and Rainfall Patterns (강수패턴과 토지이용의 시공간적 분석을 위한 SWAT모형의 검보정 개선방안 연구)

  • Lee, Ji-Won;Kum, Donghyuk;Kim, Bomchul;Kim, Young Sug;Jeong, Gyo-Cheol;Kim, Ki-Sung;Choi, Joong-Dae;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.3
    • /
    • pp.365-376
    • /
    • 2013
  • The purpose of this study was to evaluate effects of spatio-temporal changes in land uses and rainfall magnitude using the Soil and Water Assessment Tool (SWAT). Prior of application of the model to real-world problem, the model should be calibrated and validated properly. In most modeling approaches, the validation process is done assuming no significant changes occurring at the study watershed between calibration and validation periods, which is not proper assumption for agricultural watersheds. If simulated results obtained with calibrated parameters match observed data with higher accuracy for validation period, this does not always mean the simulated result represents rainfall-runoff, pollutant generation and transport mechanism for validation period because temporal and spatial variables and rainfall magnitude are often not the same. In this study SWAT was applied to Mandae study watershed in Korea to evaluate effects of spatio-temporal changes in landuses using 2009 and 2010 crop data for each field at the watershed. The Nash-Sutcliffe model efficiency (NSE) values for calibration and validation with either 2009 or 2010 was evaluated and the NSE value for calibration with 2009 and calibration with 2010 were compared. It was found that if there is substantial change in land use and rainfall, model calibration period should be determined to reflect those changes. Through these approaches, inherent limitation of the SWAT, which does not consider changes in land uses over the simulation period, was investigated. Also, Effects of changes in rainfall magnitude during calibration process were analyzed.

Interlaboratory Validation Study of In Vitro Alternatives to the Draize Eye Irritation Test : HET-CAM Test and Cytotoxicity Test for 20 Cosmetic Ingredients

  • Lee, Ho;Kim, Ju-Hyun;Hong, Jin-Cheon;Kim, Gi-Mun;Park, Mun-Eok;Ryu, Chang-Seok;Jeong, Min-Seok;Kim, Jong-Il
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.25 no.2
    • /
    • pp.129-138
    • /
    • 1999
  • 피부 전용 제재 개발을 위해 요구되는 동물 대체 시험법 중 가장 적극적으로 연구가 행하여지곤 실제 실용화가 예상되는 것은 안점막 자극 시험으로 지금까지 여러 가지 방법이 개발되었지만 그 중 계란 유정란의 응모요막(CAM)을 이용한 방법이 현재 가장 활발히 진행되고 있다. 이 방법이 일부 국가에서 이미 안점막 자극 시험 동물 대체 시험법으로 공인되었으며 현재까지도 validation 연구를 활발히 진행하고 있다. 본 연구에서도 국내에 적합한 안점막 자극 시험 동물 대체 시험법의 공인 시험법 개발 및 validation study를 목표로 계란 유정란의 응모요막을 이용한 방법 중 HET-CAM 방법을 시행하였으며 안점막 동물 대체 시험법으로 확립하고자 하였다. 틴ET-CAM 방법의 보완을 위해 배양된 세포를 통해 자극도를 측정할 수 있는 방법인 Cytotoxicity test를 도입하여 시행하였으며 두 방법의 data들을 분석하여 validation study를 수행하였다. 국내 유수의 6개 장업사가 본 연구에 참가하여 20가지의 화장품 전용제재를 대상으로 1차, 2차 validation study 를 진행하였다. HET-CAM test, Draize eye irritation test, Cytotoxicity test 측정 결과 HET-CAM 의 “Q” 수치는 대부분 강자극 수치인 2 이상이었고 10% sodium hydroxide가 가장 높은 수치를 보였으며 Tween 20(sorbitanpolyoxyethylene monolaurate) 100%가 가장 낮은 수치를 보였다. In vi패의 경우 10% sodium hydroxide가 가장 높은 수치를 보였으며 30군 propylene glycol 이 가장 낮은 자극수치를 보였다. HET-CAM test 와 Draize eye irritation test, Cytotoxicity test 간의 상관성 분석은 linear correlation coefficient 와 rank correlation coefficient를 구하여 비교하였으며 6개 장업사(A-F)의 실험실에서의 HET-CAM test 결과를 취합하여 각각 두 실험실간의 상관관계(linear correlation)를 분석하였다. Linear correlation coefficient 분석 결과를 보면 전반적으로 상관관계가 0.589 - 0.954의 범위였으며, 특히 A사와 B사 사이의 경우 0.954이었으며, E사와 D사 사이의 경우 0.942로 높은 상관관계를 보였다. 그 외에도 A사와 D사 사이의 경우(0.589)와 B사와 D사 사이의 경우(0.638)를 제외하고는 대체로 높은 상관관계를 나타내었다.

  • PDF

A Comprehensive Information System Validation Model

  • Choi, Kyung-Sub
    • 한국경영정보학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.557-561
    • /
    • 2007
  • Along with the significance of information systems in today s global business operation, the significance of information systems control and audit is ever increasing in the effort to secure accuracy and integrity of vital business data. A study is undertaken to integrate Food and Drug Administration computerized systems validation regulations. Securities & Exchange Commission Sarbanes-Oxley Act of 200 and other significant regulations, and lastly, People Capability Maturity Model into one comprehensive information system validation model. The initial benefits to this comprehensive model are convenience, time-saving, and synchronization of the regulations. An organization that is striving for a high level of quality system in its essential operating areas of organization may opt for this model. After the complete development of the model, a field test would be scheduled to test its efficacy and validity.

  • PDF

Validity of nursing diagnosis : Fluid volume deficit (체액량 부족(Fluid volume deficit) ; 간호진단의 타당도 조사 연구)

  • Byun Young-Soon;Kim Sook-Young
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.1 no.2
    • /
    • pp.207-218
    • /
    • 1994
  • A validation of the nursing diagnosis 'fluid volume deficit' was completed by using the diagnostic content validity method. Articles pertaining to fluid volume depletion were reviewed to identify the signs and symptoms used to describe the nursing diagnosis. The topics addressed in the articles included hypovolemic shock, hemorrhage, trauma, fluid balance, hydration, burn injury, thirst, dehydration. A validation instruments was constructed of 52 signs and symptoms. A validation tool was examined by expert nurses group who work on intensive care unit, kidney transplantation unit, internal medicine and general surgery unit. The study sample rated the signs and symptoms on a scale from one to five, evaluating their relevance to this diagnosis. Of the 52 signs and symptoms on the validation tool, 10 were categorized as critical indicators and 34 were categorized as defining characteristics.

  • PDF

Analytical Validation of the SDL Metrics Set (SDL 메트릭 집합의 분석적 검증)

  • Hong, Ui-Seok;Jeong, Myeong-Hui
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.4
    • /
    • pp.1112-1121
    • /
    • 2000
  • Design metrics that quantify the design phase play an important role in reducing system development cost because the problems in early phases of software development seriously affected the quality of the late products. Real-time systems such as telecommunication systems are so large that design quantification is more important in real-time system design. Although many metrics have been proposed, few of them are correctly validated. This paper revises the SDL metrics set proposed in earlier study [9] and perform an analytical validation o the metrics set. Axiomatic approach and dimensional analysis are used for metrics validation and the old metrics are revised ot satisfy the validation criteria.

  • PDF

A Study on HVAC Parameter Monitoring System (Regarding Computer Validation) (HVAC 파라미터 모니터링 시스템에 대한 고찰 (Computer Validation 중심으로))

  • Kim, Jong-Gu
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.90-95
    • /
    • 2008
  • This article presents practical advice regarding the implementation and management of an impeccable Building Management System. The BMS was introduced to the series of computerized systems including manufacturing, storage, distribution, and quality control. Recently revised GMP regulation is requesting an improvement in drug product quality regulatory system by computer system validation. Quality is critical to guarantee the efficacy and the safety of drugs and is approved in the evaluation process after the audit trail application. HVAC parameter monitoring system will record the identity of operators entering or confirming critical data. Authority to amend entered data should be restricted to nominated persons. Any alteration to an entry of critical data should be authorized in advance and recorded with the reason for the change.

  • PDF

HFFB technique and its validation studies

  • Xie, Jiming;Garber, Jason
    • Wind and Structures
    • /
    • v.18 no.4
    • /
    • pp.375-389
    • /
    • 2014
  • The high-frequency force-balance (HFFB) technique and its subsequent improvements are reviewed in this paper, including a discussion about nonlinear mode shape corrections, multi-force balance measurements, and using HFFB model to identify aeroelastic parameters. To apply the HFFB technique in engineering practice, various validation studies have been conducted. This paper presents the results from an analytical validation study for a simple building with nonlinear mode shapes, three experimental validation studies for more complicated buildings, and a field measurement comparison for a super-tall building in Hong Kong. The results of these validations confirm that the improved HFFB technique is generally adequate for engineering applications. Some technical limitations of HFFB are also discussed in this paper, especially for higher-order mode response that could be considerable for super tall buildings.

A Study on the Railway Safety Authorization for Assuring Safety of Light Rail Transit System (경전철시스템의 안전확보를 위한 안전승인(확인)제도 연구)

  • Lee, Ji-Woong;Shin, Jeong-Beom;Lee, Byung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2539-2547
    • /
    • 2011
  • This paper will introduce the safety authorization system for light rail transit(LRT) through investigating safety certification & safety authorization in foreign country and aviation field in Korea. The safety authorization system proposed by the government these day was also investigated. Korea Transportation Safety Authority(KOTSA) have conducted safety validation process on Busan-Gimhae LRT before its revenue service during three months since Jan. of 2011. We describe the overview of these validation activities, results and safety certification issued. Learning from this process, we propose the standardized safety validation process including checklists which can be applied to common unmanned light rail system. This study will be a basis of railway safety authorization for LRT and will be continually improve its application ability by the future study.

  • PDF