• Title/Summary/Keyword: vacuum valve

Search Result 84, Processing Time 0.028 seconds

Study of Mechanical Characteristics of Electric Cupping Apparatus in Korea for Suggestion of its Assessment Guideline (국내 평가 가이드 라인 제시를 위한 전동식 부항기의 특성 조사에 관한 연구)

  • Yi, Seung-Ho;Kim, Eun-Jung;Shin, Kyung-Hoon;Nam, Dong-Woo;Kang, Jung-Won;Lee, Seung-Deok;Lee, Hye-Jung;Lee, Jae-Dong;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Objectives : The mechanical properties of Korean electric cupping systems are studied via experimental measurements. The study aimed at establishing the fundamentals of industrialization and systemization of oriental medicine device industry, as well as improving the quality of life for many Koreans. Methods : We reviewed the studies on traditional cupping as well as modern one to fine necessary factors for electric cupping systems. To characterize the mechanical properties of Korean electric cupping systems, we measured the pressure characteristics of commercially available electric cupping system by using an automatic pressure acquisition system and a standard cup. The pumping capability was checked at 40 seconds, and the stability of the suction cup was checked at 600 seconds. We also acquired the noise level of each system in clinical setting. To check the portability of each system, we also measured its physical dimensions. We scrutinized system manuals provided by the system manufacturers. Results : It took less than 5 second to reach the pressure if the connection between the air hose and the vacuum valve of the cupping system was secure. Pressure diminished to no more than 10% for 600s for all systems. Noise levels were 55~70 dB. Increase in pressure was too fast to control for a designated vacuum level except for one product. Conclusions : The Pumping ability of the systems is impressive and reliable. Pressure retention ability of each cup is quite reliable and reproducible. Therefore, their mechanical performances were worthy of recommendation. Some of them had noise level higher than 60 dB and they were bothersome. It was also suggested that the control for low to middle pressure needed to be accomplished by the cupping system.

Changes in Flavor Characteristics and Shelf-life of Roasted Coffee in Different Packaging Conditions during Storage (포장 조건에 따른 저장 중 커피의 향미 특성의 변화와 보존 기간)

  • Moon, Jun-Woong;Cho, Jae-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.441-447
    • /
    • 1999
  • Changes in flavor characteristics of roasted coffee in 6 package models during storage were investigated by GC/MS analysis and sensory evaluation to establish the criteria of the shelf-life of the roasted coffee in three flavor quality-'fresh', 'satisfying' and 'minimally acceptable' levels. In direct headspace method of GC/MS, 47 volatile compounds were analyzed and the light volatile compounds were reduced sharply at initial stage of storage and faster in the package with air. The correlation between % retention of 2,3-butanedione and overall aroma of roasted coffee showed good linear-relation, of which correlation coefficient (R) were from 0.999 to 0.904 depending on package models, indicating that 2,3-butanedione would be an index chemical for evaluating the freshness of roasted coffee. In sensory evaluation of 6 package models during storage, roasted whole beans (RB) and roasted and ground (RG) coffee in air-package were preserved in 'fresh quality' for $0.5{\sim}1$ week, 'satisfying quality' for $2{\sim}3$ weeks and 'minimally acceptable quality' for 12 weeks, while roasted whole beans in valve-package and roasted and ground coffees in vacuum-package, nitrogen-package and oxygen absorbent-package were preserved in 'fresh quality' for $2{\sim}4$ weeks, 'satisfying quality' for $12{\sim}24$ weeks and 'minimally acceptable quality' for 52 weeks. The oxygen absorbent-package was slightly less effective than other three methods.

  • PDF

Magnetoresistive Properties of Array IrMn Spin Valves Devices (어레이 IrMn 스핀밸브 소자의 자기저항특성 연구)

  • Ahn, M.C.;Choi, S.D.;Joo, H.W.;Kim, G.W.;Hwang, D.G.;Rhee, J.R.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.156-161
    • /
    • 2007
  • To develop array magnetic sensors, specular-type giant magnetoresistive- spin valve (GMR-SV) film of Glass/Ta(5)MiFe(7)/IrMn(10)NiFe(5)/$O_2$/CoFe(5)/Cu(2.6)/CoFe(5)/$O_2$/NiFe(7)/Ta(5)(nm) was deposited by using a high-vacuum sputtering system. One of 15 way sensors in the area of $8{\times}8mm^2$ was Patterned a size of $20{\times}80{\mu}m^2$ in multilayer sample by Photo-lithography. All of 15 sensors with Cu electrodes were measured a uniform magnetic properties by 2-probe method. The highest magnetic sensitivity of MR and output voltage measured nearby an external magnetic field of 5 Oe were MS = 0.5%/Oe and ${\triangle}$V= 3.0 mV, respectively. An easy-axis of top-free layers of $CoFe/O_2/NiFe$ with shape anisotropy was perpendicular to one of bottom-pinned layers $IrMn/NiFe/O_2/CoFe$. When the sensing current increased from 1 mA to 10 mA, the output working voltage uniformly increased and the magnetic sensitivity was almost stable to use the nano-magnetic devices with good sensitive properties.

Post-annealing Effect of Giant Magnetoresistance-Spin Valve Device for Sensor (센서용 거대자기저항 스핀밸브소자의 열처리 효과)

  • Lee, Sang-Suk;Park, Sang-Hyun;Soh, Kwang-Sup;Joo, Ho-Wan;Kim, Gi-Wang;Hwang, D.G.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.172-177
    • /
    • 2007
  • In order to detect of the magnetic property in the cell unit, we studied the GMR-SV (giant magnetoresistance-spin valves) biosensor, which was depended on the micro patterned features according to two easy directions of longitudinal and transversal axes. Here, the multi layer structure was glass/NiO/NiFe/CoFe/Cu/CoFe/NiFe. The uniaxial anisotropy direction was applied to the patterned biosensor during the deposition and vacuum post-annealing at $200^{\circ}C$ under the magnitude of 300 Oe, respectively. Considering the magnetic shape anisotropy effect, the size of micro patterned biosensor was a $2{\times}5{\mu}m^2$ after the photo lithography process. By our experimental results, we confirmed that the best condition of GMR-SV biosensor should be the same direction of the axis sensing current and the easy axis of pinned NiO/NiFe/CoFe triple layer oriented to the width direction of device, and the direction of the easy axis of free CoFe/NiFe bilayer was according to the longitudinal direction of device.

Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer (국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선)

  • Park, Jun-Hyung;Im, Ki-Seop;Lee, Hong-Jin;Jeong, Kyung-Il;Lee, Byung-Chul;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF

UHV Materials (초고진공계재료)

  • 박동수
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.24-24
    • /
    • 1998
  • 반도체장비를 포함하는 초고진공장비의 園훌化가 급속히 그리고 절실히 요구되고 있는 것이 현실정이다. 當面해서 실현할 국산진공장비의 대상은 廣範圍하다. 즉, 각종 진공 pump ( (rotary, dry, diffusion, cryo, ion, turbo melecular pump), 진공 chamber, 진공 line, gate valve 를 위 시 한 진공 V머ve, flange, gasket, fl않d야lU, mainpulater 퉁 진공 部品이 다. 진공계 의 핵심 은 適切하고 優良한 진공재료의 선태파 사용이다. 진공장비는 사용자가 원하는 진공도를 원하 는 시간 동안 륨空度를 유지해 주어야 한다. 진공재료 선태의 기준사항은:(1) 기체의 透過성 (2) 薰했훌 (3) 혔體放出특성 - -outgassing과 degassing- (4) 機械的 량훌度 (5) 온도 의존성 (6) 化學톡성 (7) 加I성 및 鎔接 성 (8) 課電특성 (9) 磁氣특성 (10) 高速함子 및 放射線 특성 (11) 經濟성 및 調達생 둥이 다. 우량한 초고진공계재료는 풍부하게 개발되어 왔고, 또 新材料들이 개발되고 있다. 여기에서는 주로 초고진공 내지는 극고진공계의 構造材料, 機能材料, 部品材料 일반파 몇가지 신재료의 특 성에 관해서 記述한다. M Mild SteeHSAE, 1112, 1010, 1020, 1022, etc)., S Stainless SteeHAlSI, 304, 304L, 310, 316, 321, 347): 구조재료, chamber, fl하1ges A Aluminum과 Alloys (1060, 1100, 2014, 4032, 6(뻐1): 구조재료, chamber, flanges, gaskets A AI, Al 떠loy는 SS에 代替하는 역 할올 시 작하고 있다. C Copper, Copper Alloys(C11$\alpha$)0, C26800, C61400, Cl7200): 내장인자, gasket, cryopanel, tubing T Titanium, Ziriconium, Haf띠um 및 Alloys: 특히 Ti은 10n pump 용 getter material 이 외 에 U UHV,XHV용 chamber계로서 관심올 끌고 있다. N Nickel, Nickel Alloys (200, 204, 211, monel, nichrome): 부식 방지 , 전자장치 , 자기 장치 귀 금속(Ag, Au, Pt, Pd, Rh, Ir, Os, Ru): 보조부품, gasket, filament, coating, thermocouple, 접 합부위 T TiC, SiC, zrC, HfC, TaC 둥의 탄화물과, BN, TiN, AlN 동의 질화물, 붕화물이 둥장하고 었 다. 유리: Soda Lime, Borosilicate, Potash Soda Lead: View Port, Chamber envelope C Ceramics: AlZ03, BeO, MgO, zrOz, SiOz, MgOzSiOz, 3Alz032SiOz, Z$textsc{k}$hSiOz S상N4: e electrical, thermal insulators, crucibles, boats, single crystals, sepctr려 windows 저자는 최근 저자들이 발견한 Zr-Ti-Cu-Ni-Be amorphous alloys coated cham뾰r가 radiation p proof로 이용될 수 있는 사실을 점검하고 었다 .. Z.Y. Hua 들은 Cs3Sb를 새로운 photocathode 재료로 보고하고 있다.

  • PDF

A study on electroreflectance in undoped n-GaAs (불순물이 첨가되지 않은 n-GaAs에서의 Electroreflectance에 관한 연구)

  • 김인수;김근형;손정식;이철욱;배인호;김상기
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.2
    • /
    • pp.136-142
    • /
    • 1997
  • An/n-GaAs(100) Schottky barrier diode has been investigated by using electoreflectance(ER). From the observed Franz-Keldysh oscillatins(FKO), the internal electric field(Ei) of the sample is $5.76\times 10^{4}$V/cm at 300 K. As the modulation voltage($V_{ac}$) IS changed, the line shape of ER signal does not change but its amplitude various linerly. For increasing forward and reverse dc bias boltage($V_{bias}$), the amplitude of ER signal decreases. The internal electric field decreased from $19.3\times 10^4\sim4.39\times10^4$V/cm as $V_{bias}$ INCREASES FROM -5.0 V TO 0.6 V. For Au/n-GaAs the valve of built-in voltage($V_{bi}$) determined from the plot of $V_{bias}$ versus $E_i^2$ is 0.70 V. This value agrees with that observed in the plot of $V_{bias}$ versus amplitude of FKO peak. In addition, the carrier concentraion(N) and potential barrier($\Phi$) of the sample at 300 K are found to be about $2.4\times 10^{16}\textrm{cm}^{-3}$ and 0.78 eV, respectively.

  • PDF

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

The history, present status and future perspective of electronics and electronic technologies (전자공학 및 전자기술의 역사, 현황 그리고 미래)

  • 조규심
    • Journal of the Korean Professional Engineers Association
    • /
    • v.24 no.6
    • /
    • pp.106-112
    • /
    • 1991
  • Electronics has different meanings to different people and in different countries. Hence, let me difine the term in the sense that it is used here. Electronics in the science and the technology of the passage of charged particles in a gas, in a vacumn, or in a semiconductor. The beginning of electronics came in 1895 when H. A. Lorentz postulated the existence of discrete charges called electrons. Two years later J.J. Thompson found these electrons experimentally. In the same year (1897) Braun built what was probaly the first electron tube, essentially a primitive cathode-ray tube. It was not until the start of the 20th century that electronics began to take technological shape. In 1904 Fleming invented the diode which he called a valve. This era begins with the invention of the transistor about 30 years ago. The history of this invention is interesting. M.J. Kelly, director of research(and later president of Bell Laboratories), had the foresight to realize that the telephone system needed electronic switching and better amplifiers. Vacuum tubes were not very reliable, principally because they generated a great deal of heat even when they were not being used, and, particularly, because filaments burned out and the tubes had to be replaced. In 1945 a solid-state physics group wa formed. The foregoing completes the history of electronics and electronic industries up to 1978. There is already a start toward a merging of the computer and the communication industries which might be called information manipulation. This includes storage of information, sorting, computation, information retrieval, and transmission of data. This combination of the computer and the communication fields will penetrate many disciplines. Applications will be made in the fields of law, medicine, biological sciences, engineering, library services publishing banking, reservation systems, management control, education, and defense.

  • PDF

Property Prediction of Rupture Disc by Using Finite Element Analysis (유한요소해석을 이용한 파열판의 특성 예측)

  • Han, Chang-Yong;Lee, Seong-Beom;Jung, Hee-Suk;Kim, Tae-Gu
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.3
    • /
    • pp.1-6
    • /
    • 2009
  • High pressure devices are used widely. Interest in rupture disc to people is the increases in protect of facilities and people. A rupture disc consists of mainly three parts: holder, plate and vacuum support. Rupture discs are rusted or destroyed by diverse environments. Rupture discs are made from STS 316L stainless steel because of its high corrosion resistance and yield strength. In this study, modeling of a rupture disc by CATIA V5 and finite element analysis by ANSYS were carried out. The finite element analysis results executed to predict properties of the rupture disc with thickness and height.

  • PDF