• 제목/요약/키워드: vacuum valve

검색결과 84건 처리시간 0.029초

$Permalloy/Al_{2}O_{3}/Co$ 접합의 자기터널 효과 (Magnetic Tunneling Effects in $Permalloy/Al_{2}O_{3}/Co$ Junction)

  • 이민숙;송현주;장현숙;김미양;이장로;이용호
    • 한국자기학회지
    • /
    • 제3권1호
    • /
    • pp.29-33
    • /
    • 1993
  • $1{\times}10^{-6}$Torr의 진공에서 열저항 가열식 진공증착 방법으로 제작한 $Permalloy/Al_{2}O_{3}/Co$ 강자성 터널집합의 자기저항 효과를 조사하였다. 이 논문에서는 제작한 강자성 터널접합 시료의 전류-전압 특성과 자기 valve 효과를 측정하고, 시료진동형자기계로 측 정한 자기이력곡선을 통하여 터널저항의 히스테리시스성 자장 의존성을 조사하였다. 터널링은 전류-전압 특성을 측정함으로써 확인 되어진다. 자기저항의 히스테리시스 곡선은 자화의 히스테 리시스 곡선과 잘 대응한다. 측정한 자기저항비 ${\Delta}R/R$은 실온에서 약 0.6% 였다.

  • PDF

Uniaxial Magnetic Anistotropy of a NiO-Spin Valve Device

  • Lee, Won-Hyung;Hwang, Do-Guwn;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제14권1호
    • /
    • pp.18-22
    • /
    • 2009
  • The shape anisotropy effect of a giant magnetoresistance-spin valves (GMR-SV) device with a glass/NiO/NiFe/CoFe/Cu/CoFe/NiFe layered structure for use in the detection of magnetic property of molecules within a cell was investigated. The patterned device was given uniaxial anisotropy during the sputtering deposition and vacuum post-annealing, which was performed at $200^{\circ}C$ under a 300 Oe magnetic field. The pattern size of the device, which was prepared through the photolithography process, was $2{\times}15\;{\mu}m^2$. The experimental results confirmed that the best design for a GMR-SV device to be used as a biosensor is to have both the axis sensing current and the easy axis of the pinned NiO/NiFe/CoFe triple layer oriented in the direction of the device's width, while the easy axis of the free CoFe/NiFe bilayer should be pointed along the long axis of the device.

기체연료주입계의 긴 원형도관에서 기체 흐름의 유형 (Gas flow pattern through a long round tube of a gas fueling system (I))

  • 인상렬
    • 한국진공학회지
    • /
    • 제15권5호
    • /
    • pp.465-474
    • /
    • 2006
  • 기체저장용기, 단순 개폐밸브 및 기체 공급 관으로 구성된 기체연료 주입계는 가장 간단하게 사전에 기체 도입유형을 정할 수 있다는 장점이 있다. 장치의 동작특성을 알아보기 위해 기체 흐름에 관한 일차원 동특성 방정식을 세우고 수치적으로 풀었다. 이 계산의 목적은 저장기체 압력, 저장용기 체적, 공급관의 굵기, 길이 따위의 기계적 요소들과 최대유량까지의 지연시간, 최대유량 값, 기체 펄스폭 따위의 기체 흐름의 유형을 결정하는 인자들 사이의 관계를 정립하려는 것이다.

Characterization of electron beam (EB) welds for SUS310S

  • Kim, Hyun-Suk;Castro, Edward Joseph D.;Lee, Choong-Hun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.360-360
    • /
    • 2011
  • In this work, SUS310S used for valve plate assembly was electron beam (EB) welded to determine the influence of the parametric conditions on the characteristics of the weld and to minimize porosity and micro-fissures among others. The evolution in the weld geometry and microstructure was examined as a function of the process conditions such as beam current and focusing current under a constant welding speed and accelerating voltage. The integrity of the EB welds in SUS310S was examined for defects (e.g. cracking, porosity, etc.), adequate penetration depth, and tolerable weld width deviation for the various welding conditions. Optical microscopy (OM), x-ray photoelectron spectroscopy analysis (XPS), scanning electron microscopy (SEM) and 3D micro-computed tomography (Micro-CT) for the cross section analysis of the electron beam welded SUS310S were utilized. The tensile strength and hardness were analyzed for the mechanical properties of the EB weld. At the 6 kV accelerating voltage, it was determined that a satisfactory penetration depth and desirable weld width deviation requires a beam current of 30 mA and a focusing current of 0.687 A at the welding speed of 25 mm/sec.

  • PDF

사지에 발병한 카포시육종의 방사선치료를 위한 물볼루스 기구의 유용성 고찰 (Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients)

  • 안승권;김용배;이익재;송태수;손동민;장영재;조정희;김주호;김동욱;조재호;서창옥
    • Radiation Oncology Journal
    • /
    • 제26권3호
    • /
    • pp.189-194
    • /
    • 2008
  • 목 적: 본 연구팀은 사지에 발병한 카포시육종의 방사선치료를 위하여, 물볼루스를 사용할 수 있는 기구를 고안하였고, 쌀볼루스 사용시와 비교하여 유용성을 평가하고자 하였다. 대상 및 방법: 환자가 앙와위 자세에서 하지를 삽입 할 수 있는 폴리스틸렌 상자를 만들고 비닐 재질의 진공비닐을 집어 넣어 물이 누수 되지 않도록 결합하였으며, 진공비닐안에 하지와 물 사이의 공기를 없애기 위해 진공 밸브와 진공 펌프를 연결하여 공기를 제거하였다. 본 연구에서 제작한 물기반 볼루스의 선량 균질도를 비교 평가하기 위해 진공비닐에 하지 팬텀을 삽입한 후 폴리스틸렌 상자에 직접 쌀을 채운 경우, 비닐봉지에 쌀을 담아서 넣은 경우, 그리고 물을 직접 채운 경우에 대해 전산화단층촬영을 시행하였다. 방사선치료계획시스템을 사용하여 공기층의 부피에 의한 밀도의 변화를 분석하였다. 또한 선형가속기를 사용하여 전산화단층 모의치료기와 동일한 셋업에서 하지 팬텀에 필름을 감고, 열형광선량계 6개를 조사야 안에 균등하게 붙여서, 대향이문 조사하여 선량의 균질도 및 선량 값을 측정하였다. 결 과: 각 세 종류 실험의 밀도 측정결과 물볼루스를 기준으로 쌀을 직접 넣은 경우는 14% 감소했으며, 쌀을 비닐 봉지에 나누어 넣은 경우는 18% 감소하였다. 필름의 분석 결과 물볼루스가 쌀볼루스보다 균질도가 $4{\sim}4.4%$ 정도 우수한 것으로 나타났다. 열형광선량계 측정 평균값 분석결과 물볼루스를 기준으로 쌀을 직접 넣은 경우는 3.4% 증가했으며, 쌀을 비닐봉지에 나누어 넣은 경우는 4.3% 증가하였다. 결 론: 자체 제작한 물볼루스 기구는 육안으로 치료 조사야를 확인할 수 있어 셋업의 정확성을 높였으며, 진공 밸브와 진공 펌프를 사용하여 공기층을 감소시켜 치료의 정확성을 높이는 동시에 목적 종양에 균질도가 높은 선량을 부여 할 수 있는 좋은 방안이라 할 수 있다.

WS$_2$ 고체윤활제의 양산 및 적용 (Mass-production of WS$_2$ Solid Lubricant and Its applications)

  • 신동우;최인혁;윤대현;김경도
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제28회 추계학술대회
    • /
    • pp.221-226
    • /
    • 1998
  • The processing conditions for the mass production of platelet WS$_2$ lubricant powder were optimized. The mixture of tungsten and sulfur powders was sealed in a vacuum of 10$^{-3}$ torr and heat-treated at 850$\circ$C for 2 h. The internal pressure of reaction chamber was maintained at certain level by controlling the release valve automatically. The reaction product was the platelet WS$_2$ powder with an average size of 15 $\mu$m. The synthesized WS$_2$ powder was then coated on the wiper-blade of automobiles and the commercial deep-grooved ball bearing using wet and dry coating methods, respectively. High lubricity and wear resistance of wet coated wiper-blade were confirmed by the life test of 70,000 cycles. The life-time of the ball bearing assembled after WS$_2$ coating onto each part increased 50 times compared to the non-coated ball bearing.

  • PDF

XY Recorder에 있어 Noise (XY Recording)

  • 김은배
    • 전기의세계
    • /
    • 제20권5호
    • /
    • pp.40-42
    • /
    • 1971
  • XY recorder는 10여년전부터 널리사용되어 오는 기록계로 2개의 자동평형전위차계로 X, Y축방향에 arm과 pen의 결합으로 양자의 좌표축의 교점에서 pen이 평형정지하는 상태에 기록지자체가 servo motor로 이동되어 기록이 가능하게 된다. 특히 타기록계에 비하여 고감도(Ex. 0.5V/cm), 고정도(Ex. 0.3%)임은 물론 y=f(x)인 x,y의 함수관계가 기록되어 타기록계에서는 얻기 어려운 특징이 있어, analog computer의 해의 기록계로서, 도한 각종 검출변환기를 전설치하여 vacuum tube 혹은 diode transistor의 특성곡선, 전기철판등의 자성재료의 자화곡선, 회전기의 회전수-전압, 전류, 출력, 효율곡선, 금속재료의 온도 혹은 인신장곡선, pipe valve의 유량-압력곡선등 전기.전지.기계.재료.물리.화학등의 다각도용도로서 연구실험은 물론 생산현장에 있어서의 시험. 정리. 감시등의 치용이 활발히 급진하는 경향에 비추어 이 기록계 사용에 고려되어야할 noise제거의 한 방법을 소개하고저 한다.

  • PDF

가스 센서 기반 향 수집기 구현 (Implementation of Gas Sensor-based Scent Collector)

  • 이연성
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 추계학술대회
    • /
    • pp.336-337
    • /
    • 2018
  • 본 논문에서는 다종의 가스 센서를 이용하여 향 정보를 수집하기 위한 향 수집기의 구현 결과를 기술하였다. 제안된 향 수집기는 솔레노이드 밸브, 진공 펌프, 4개의 가스 센서 및 챔버, Raspberry Pi 모듈로 구현되었다. 제안된 향 수집기를 검증하기 위해 5종류의 향에 대한 향 수집 실험을 수행하였다.

  • PDF

Teensy 마이크로 컨트롤러 기반 산소 유량 제어기 개발 및 성능평가 (Development and Evaluation of a Teensy Microcontroller-based O2 Mass Flow Controller)

  • 유민상;장연숙;김무환;조성보
    • 대한의용생체공학회:의공학회지
    • /
    • 제42권4호
    • /
    • pp.193-200
    • /
    • 2021
  • Flowmeter and oxygen sensors are listed in COVID-19 essential medical devices. This article reports a Teensy microcontroller-based Oxygen mass flow controller (MFC), core part of the oxygen respirator or extracorporeal membrane oxygenation (ECMO). The developed MFC consisting of the microcontroller, MEMS flow sensor, and solenoid valve was able to accurately control 0 to 100 sccm of oxygen flow rate. The pressure of vacuum chamber increased proportionally to the flow rate (0.998 of Pearson correlation coefficient). The experimental results proved that the developed MFC exhibits comparable performance to a commercial MFC in accuracy, settling time, linearity with pressure, and repeatability of oxygen mass flow control. It is expected that this simple and cheap MFC is utilized for oxygen therapy against the severe acute respiratory syndrome coronavirus 2.

전동식 부항기에 대한 안전성 및 성능평가 가이드라인 개발연구 (Study on Developing Assessment Guideline for Safety and Performance of Electric Cupping Apparatus)

  • 이승호;김은정;신경훈;남동우;강중원;이승덕;이혜정;이재동;김갑성
    • Journal of Acupuncture Research
    • /
    • 제26권6호
    • /
    • pp.101-110
    • /
    • 2009
  • Objectives : We developed and proposed a guideline for safety and performance assessment of electric cupping apparatus(Class 2 medical device). Methods : We drafted the guideline for safety and performance assessment of electric cupping apparatus by referring the existing standards and guideline, based on online questionnaire for Korean medical doctors and measurement data from commercially available products. Physical dimension of cups and inner vacuum pressure were acquired for the measurement in order to achieve the purposes. Results : This guideline only can be applied to electric cupping apparatus for enhancing blood circulation by employing negative pressure generated by electricity. Seven items of appearance and label, operation test of pump, variation test of input electricity, vacuum level test, vacuum sustain test, cup-size dependent test, noise level test are suggested for evaluation subjects and methods required for electric cupping devices. Requirements for the design and development of electric cupping devices are suggested: vacuum level indicator, vacuum generation rate, pressure control, valve detachment stability, cup comparability, safety measure, surge protection, user friendliness, instruction for use (IFU). Conclusions : We proposed a guideline for safety and performance assessment of electric cupping apparatus to improve the quality of relating products and aid the commercialization of them, by aiming higher industrial competitiveness of the medical device sectors in Korea. Discussion with related institutes such as industry, academy and government is further required. Public hearings also need to be held prior to the establishment of a final guideline and standard.

  • PDF