• 제목/요약/키워드: uv test

검색결과 671건 처리시간 0.031초

Interactive Effects of UV-B and Pesticides on Photosynthesis and Nitrogen Fixation of Anabaena doliolum

  • Chandrai, Lar;Vandana, Pandey
    • Journal of Microbiology and Biotechnology
    • /
    • 제12권3호
    • /
    • pp.423-430
    • /
    • 2002
  • The effects of UV-B and commercial grade pesticides (butachlor and carbofuran), individually and in combination, were studied on a variety of physiological processes of rice field cyanobacterium Anabaena doliolum. Butachlor was found to be $2-12\%$ more toxic than carbofuran and $4-24\%$ than UV-B on the growth, photosynthesis, lipid peroxidation, membrane permeability, and nitrogenase activity of the test cyanobacterium. Of the three photosynthesis inhibitors, the butachlor-induced inhibition of whole chain was approximately 3 and $21\%$ higher than carbofuran and UV-B, respectively. Although the interaction of the stress factors caused a significant inhibition (P<0.01), it was still less than the additive effect on the parameters investigated, except for PSI.

Measurement Technique of Ozone Density by Using UV Sensor System

  • Trung, Nguyen Huu;Van Men, Le;Van Hieu, Nguyen
    • 전기전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.80-86
    • /
    • 2015
  • There are many studies and products using a test paper impregnated with chemical solution can react with ozone. The color of a test paper can indicate the concentration of ozone. The purpose of this research is to design and manufacture a system using ultraviolet light source to measure the ozone density. This new technique is based on the characteristic of decomposition from ozone into oxygen under ultraviolet light. We used two sources of ultraviolet light including UV lamp and UVLED to determine the decomposition of ozone. This system is built with the electronic components, sensors and sealed pump tube to measure the ozone density in units of $g/cm^3$,ppm,ppb. In this paper,, we present some initial results of measuring the ozone density from ozone generator after completing inspection for safety.

폰 카메라 모듈 자동 조립.평가시스템 설계 (Design of Automatic Assembly & Evaluation System for Phone Camera Module)

  • 송준엽;이창우;하태호;정연욱;김영규;이명철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.71-72
    • /
    • 2006
  • In this study, automatic assembly and evaluation system fer phone camera module is conceptually designed. The designed core(Auto focus & UV curing, Image Test) equipments adopts a clustering mechanism and compactible structure using index table for minimum tact time. Using a ball screw actuator and absolute encoder in each axis, we can verifies the repeatability and position accuracy of system within ${\pm}3{\mu}m$. In result of simulation test, the proposed system is expected up to 30% in productivity than manual operation.

  • PDF

네가티브 포토레지스트용 아크릴레이트계 바인더 합성 (Synthesis of Acrylate Binders for Negative Photoresist)

  • 김난수;남병욱
    • 반도체디스플레이기술학회지
    • /
    • 제8권3호
    • /
    • pp.25-30
    • /
    • 2009
  • In this study, we synthesized novel UV-curable binders and applied for negative photoresist of display device. First, we synthesized UV-curable binders by radical polymerization with a mixture of Styrene/Methyl methacrylate/Methacrylic acid/Glycidyl methacrylate/N-Cyclohexylmaleimide at a fixed composition. Following the first step, we prepared a negative photoresist mixture optimized with photo sensitive initiator and others for the litho test. And then, we studied resolution and film retention with molecular weight of each binders and numerical value of Alkaline Desolution Rate(ADR). As a result of the litho test, we found that if the novel polymers have same numerical value of ADR, the resolution decreased and the film retention increased with the increasing of molecular weight of photoresist binder.

  • PDF

UV 투과율 향상 필터 기술을 이용한 전력설비 방전 검출용 자외선 코로나 카메라 개발 (Development of UV Corona Camera for the Detecting of Discharge on Power Facility using UV Transmittance Improvement Filter)

  • 김영석;최명일;김종민;방선배;송길목
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1656-1661
    • /
    • 2012
  • UV inspection technology is being used for predictive maintenance of power facility together with IR-thermography and ultrasonic devices. In this paper, the UV corona camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. The UV corona camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The transmission between 250 to 280nm was 11% ($12.5%{\times}88%{\times}98%$) by combing the transmission on absorption film, window and other filter(UG 5, nickel sulphate and so on). In a distance of 5m with the UV corona camera it is possible to detect partial discharge with a PD level of 2.5pC and a RIV level of $3.6dB{\mu}V$.

가감자운액(加減紫雲液) 도포가 자외선으로 유발된 피부 홍반에 미치는 영향 (Effects of Gagam-Jawoonaek about Erythema by UV Exposure)

  • 김태연;김용민
    • 동의생리병리학회지
    • /
    • 제28권1호
    • /
    • pp.94-101
    • /
    • 2014
  • We studied to investigate the erythema reduction effects generated by Gagam-Jawoonaek(GJ) application(appl.) after UV exposure. Twenty women in their twenties to fifties with no skin diseases were recruited. We exposed UV as a 6 subsites on the left upper arm of subjects using multi-port solar simulator. After setting Gagam-Jawoonaek(GJ) application(appl.) subsites and non-appl. subsites, we measured erythema degrees($a^*$ values) of the subsites using spectrophotometer. We measured $a^*$ values four times(before UV exposure, before application of GJ, twenty-four and forty-eight hours after first application of GJ). We analyzed data using student's t-test. After UV exposure, $a^*$ values on the left upper arm increased. Twenty-four hours after first GJ treat., the changes of $a^*$ value on GJ treat. subsites($1.22{\pm}0.13AU$) were bigger than GJ non-treat. subsites($1.04{\pm}0.12AU$), but there was no statistically significance. Forty-eight hours after first GJ treat., the changes of $a^*$ value on GJ treat. subsites($1.95{\pm}0.11AU$) were bigger than GJ non-treat. subsites($1.58{\pm}0.13AU$), a statistically significance. Gagam-Jawoonaek could decrease erythema by UV exposure.

자동차용 선도장 베이스코트에서 알루미늄 입자 크기와 배향에 따른 내후성 연구 (A Study on Weatherability with Particle Size and Orientation of Aluminum in Pre-painted Basecoat for Automotive)

  • 이재우;조을룡
    • Elastomers and Composites
    • /
    • 제48권2호
    • /
    • pp.167-171
    • /
    • 2013
  • 자동차용 선도장 베이스코트 도료에서 사용되는 알루미늄의 입자 크기와 배향에 따른 내후성을 연구하였다. UV를 촉진하여 조사할 수 있는 QUV$^{(R)}$ (Q-LAB) 장비를 이용하여 UV 투과율의 차이에 의한 소재의 손상 정도를 관찰하였다. Conflake 형태의 입자 크기가 서로 다른 3종의 알루미늄 paste를 이용하여 자동차용 선도장 조건으로 베이스코트를 도장하고 투명 클리어를 도장하여 필름과 시편을 제조하였다. 작성된 필름을 UV 투과 장비로 측정한 결과 입자 크기가 작고 수평 배향인 EKART사의 #790을 사용 시 낮은 UV 투과율을 나타내었다. 실제 내후성 시편의 단면 조사에서도 #790, #770, #750 순으로 높은 광택 유지율을 나타내었다.

Flame-retardant Coating of Cotton Fabric via UV curing of DMEP

  • Jang, Jin-Ho;Kim, Young-Min;Jeong, Yong-Kyun;Nam, Young Sik
    • 한국염색가공학회지
    • /
    • 제19권5호
    • /
    • pp.1-7
    • /
    • 2007
  • A new UV-curable coating was carried out to impart the flame-retardant property to cotton fabric using Bis[2-(methacryloyloxy)ehtyl]phosphate(DMEP) and 2-hydroxy-2-methyl-1-phenyl-propan-l-one(HMPP) as a UV-curable monomer and a photoinitiator, respectively. The cotton fabrics were applied with various amounts of DMEP and HMPP via padding and UV irradiation, and the optimal concentrations of DMEP and HMPP in the formulation were 40%(w/w) and 7%omp respectively. A limiteed oxygen index(LOI) up to 28.9 was obtained for the UV-cured fabric, which may occur through a condensed phase mechanism as verified by the increased residue number with increased application level. The characterization of the UV-cured coating was made by IR analysis, thermo-gravimetric analysis, LOI test, and scanning electron microscopy.

UV경화에 의한 폴리우레탄/유기화클레이 나노복합재료 제조와 물성 연구 (Preparation and Characterization of Polyurethane/Organoclay Nanocomposites by UV Curing)

  • 신금식;장영욱;김성우
    • 접착 및 계면
    • /
    • 제13권4호
    • /
    • pp.156-162
    • /
    • 2012
  • UV 경화형 우레탄아크릴레이트 수지와 유기화클레이를 혼합한 후 UV를 조사하여 경화시킴으로써 폴리우레탄-클레이 나노복합체를 제조하였다. 유기화클레이로서는 Closite20A (C20A) 및 이를 실란처리하여 표면에 아크릴기를 도입한 아크릴변성 C20A를 사용하였다. XRD와 TEM 분석으로부터 제조된 나노복합체는 삽입형 나노복합체이며, 아크릴 변성시킨 C20A가 변성시키지 않은 C20A에 비해 더 잘 분산되는 것을 알 수 있었다. DMTA, 연필경도분석, PET 필름에의 부착성 시험으로부터 클레이 첨가에 의해 유리전이온도와 저장탄성률 및 연필경도가 증가하고 PET 필름에의 부착성이 향상되며, 이러한 물리적 특성의 증가는 아크릴 변성시킨 C20A를 함유한 나노복합체에서 더 크게 발현됨을 알 수 있었다. 또한, 클레이 첨가에 의해 UV경화 시 수반되는 수축을 저하시킬 수 있음을 알았다. 한편, 제조된 나노복합체는 우수한 광투과도를 나타내었으나, 광택도는 나노입자를 함유하지 않은 경우에 비해 다소 저하되었다.

Electro-Micromechanical 시험법을 이용한 탄소섬유 강화 Epoxyacrylate 복합재료의 UV 및 열경화에 따른 비파괴적 손상 감지능 및 경화 Monitoring (Nondestructive Damage Sensing and Cure Monitoring of Carbon Fiber/Epoxyacrylate Composite with UV and Thermal Curing using Electro-Micromechanical Technique)

  • Kong, Jin-Woo;Kim, Dae-Sik;Park, Joung-Man;Lee, Jae-Rock
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 추계학술발표대회 논문집
    • /
    • pp.261-264
    • /
    • 2002
  • Interfacial evaluation, damage sensing and cure monitoring of single carbon fiber/thermosetting composite with different curing processes was investigated using electro-micromechanical test. After curing, residual stress was monitored by measurement of electrical resistance (ER) and then it was compared to correlate with various curing processes. In thermal curing, curing shrinkage appeared significantly by matrix shrinkage and residual stress due to the difference in thermal expansion coefficient (TEC). The change in electrical resistance (ΔR) on thermal curing was higher than that on ultraviolet (UV) curing. For thermal curing, apparent modulus was the highest and reaching time until same strain was faster. So far thermal curing shows strong durability on the IFSS after boiling test.

  • PDF