• Title/Summary/Keyword: utility detection

Search Result 226, Processing Time 0.029 seconds

Onset Date of Forest Canopy Detected from MODIS Leaf Area Index

  • Kim, So-Hee;Kang, Sin-Kyu;Lim, Jong-Hwan
    • Journal of Ecology and Environment
    • /
    • v.31 no.2
    • /
    • pp.153-159
    • /
    • 2008
  • The timing of the canopy phenology onset (CPO hereafter) indicates the initiation of the growing season, with rapid increases in exchange rates of carbon dioxide and water vapor between vegetation and atmosphere. The CPO is regarded as a potential indicator of ecosystem responses to global warming, but the CPO shows considerable spatial variation depending on the species composition and local temperature regime. at a given geographic location. In this study, we evaluated the utility of satellite observation data for detection of the timing of the CPO. Leaf area indices (LAI) obtained from the Moderate Resolution Imaging Spectrora-diometer (MODIS) were utilized to detect and map the onset dates from 2001 to 2006. The reliability of MODIS-based onset dates was evaluated with ground measured cherry blossom flowering data from national weather stations. The MODIS onset dates preceded the observed flowering dates by 8 days and were linearly related with a correlation coefficient of 0.58 (p < 0.05). In spite of the coarse spatial (1 km) and temporal (8 days) resolutions of MODIS LAI, the MODIS-based onset dates showed reasonable ability to predict flowering dates.

Satellite-detected red tide algal blooms in Korean and neighboring waters during 1999-2004

  • Ahn Yu-Hwan;Shanmugam Palanisamy
    • Proceedings of the KSRS Conference
    • /
    • 2006.03a
    • /
    • pp.95-100
    • /
    • 2006
  • Measurements of ocean color from space since 1970s provided vital information with reference to physical and biogeochemical properties of the oceanic waters. The utility of these data has been explored in order to map and monitor highly toxic/or harmful algal blooms (HABs) that affected most of coastal waters throughout the world due to accelerated eutrophication from human activities and certain oceanic processes. However, the global atmospheric correction and bio-optical algorithms developed for oceanic waters were found to yield false information about the HABs in coastal waters. The present study aimed to evaluate the potential use of red tide index (RI) method, which has been developed by Ahn and Shanmugam (2005), for mapping of HABs in Korean and neighboring waters. Here we employed the SSMM to remove the atmospheric effect in the SeaWiFS image data and the achieved indices by RI method were found more appropriate in correctly identifying potential areas of the encountered HABs in Korean South Sea (KSS) and Chinese coastal waters during 1999-2004. But the existence of high absorbing and scattering materials greatly interfered with the standard OC4 algorithm which falsely identified red tides in these waters. In comparison with other methods, the RI approach for the early detection of HABs can provide state managers with accurate identification of the extent and location of these blooms as a management tool.

  • PDF

Determination of Phthalate Metabolites in Human Serum and Urine as Biomarkers for Phthalate Exposure Using Column-Switching LC-MS/MS

  • Jeong, Jee-Yeon;Lee, Ji-Hyun;Kim, Eun-Young;Kim, Pan-Gyi;Kho, Young-Lim
    • Safety and Health at Work
    • /
    • v.2 no.1
    • /
    • pp.57-64
    • /
    • 2011
  • Objectives: Although phthalates like dibutyl phthalate (DBP) and di-2-ethylhexyl phthalate (DEHP) are commonly used as plasticizers and their metabolites are especially suspected of reproductive toxicity, little is known about occupational exposure to those phthalates. The aim of this study was to assess the utility of measuring the metabolite concentrations of DBP and DEHP in serum and urine samples as an indicator of occupational exposure to those phthalates. Methods: Phthalate metabolites were analyzed by using column-switching high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS). Results: We detected phthalate metabolites in serum and urine matrices at approximately 10-fold lower than the limit of detection of those metabolites in the same matrix by LC-MS/MS without column switching, which was sufficient to evaluate concentrations of phthalate metabolites for industrial workers and the general population. Conclusion: The accuracy and precision of the analytical method indicate that urinary metabolite determination can be a more acceptable biomarker for studying phthalate exposure and adverse health outcomes.

A Fluorescence-based cDNA-AFLP Method for Identification of Differentially Expressed Genes

  • Park, Sook-Young;Jwa, Nam-Soo;Chi, Myoung-Hwan;Lee, Yong-Hwan
    • The Plant Pathology Journal
    • /
    • v.25 no.2
    • /
    • pp.184-188
    • /
    • 2009
  • Identification of differently expressed genes under specific tissues and/or environments provides insights into the nature and underlying mechanisms of cellular processes. Although cDNA-AFLP (Amplified Fragment Length Polymorphism) is a powerful method for analyzing differentially expressed genes, its use has been limited to the requirement of radioactive isotope use and the difficulty of isolating the bands of interest from a gel. Here, we describe a modified method for cDNA-AFLP that uses a fluorescence dye for detection and isolation of bands directly from a small size polyacrylamide gel. This method involves three steps: (i) preparation of cDNA templates, (ii) PCR amplification and differential display, and (iii) identification of differentially expressed genes. To demonstrate its utility and efficiency, differentially expressed genes during vegetative growth and appressorial development of Magnaporthe oryzae were analyzed. This method could be applied to compare gene expression profiles in a diverse array of organisms.

Anamorphic Infrared Camera with Wide Field of View and Optomechanical Automatic Athermalization Mechanism (광기구적 자동 비열화가 적용된 비정형 적외선 광각 카메라)

  • Kim, Hyunsook;Ok, Chang Min
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.4
    • /
    • pp.187-194
    • /
    • 2015
  • A system of infrared camera optics with wide field of view and anamorphic lenses is proposed, and its validity verified through manufacture. The infrared camera produced provides a wide field of view of over 100 degrees in the horizontal direction, and an even greater magnification in the vertical direction. As a result, the system can have a wider surveillance range and improved detection ability at the same time. In addition, a new optomechanical automatic athermalization mechanism is proposed and applied to the infrared camera. Its performance and utility is proved through testing.

Modified Glassy Carbon Electrode with Polypyrrole Nanocomposite for the Simultaneous Determination of Ascorbic acid, Dopamine, Uric acid, and Folic Acid

  • Ghanbari, Khadijeh;Bonyadi, Sepideh
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.68-83
    • /
    • 2020
  • A fast and simple method for synthesis of CuxO-ZnO/PPy/RGO nanocomposite by electrochemical manner have been reported in this paper. For testing the utility of this nanocomposite we modified a GCE with the nanocomposite to yield a sensor for simultaneous determination of four analytes namely ascorbic acid (AA), dopamine (DA), uric acid (UA), and folic acid (FA). Cyclic voltammetry (CV) and Differential pulse voltammetry (DPV) selected for the study. The modified electrode cause to enhance electron transfer rate so overcome to overlapping their peaks and consequently having the ability to the simultaneous determination of AA, DA, UA, and FA. To synthesis confirmation of the nanocomposite, Field emission scanning electron microscopy (FE-SEM), Raman spectroscopy, and electrochemical impedance spectroscopy (EIS) were applied. The linearity ranges were 0.07-485 μM, 0.05-430 μM, 0.02-250 μM and 0.022-180 μM for AA, DA, UA, and FA respectively and the detection limits were 22 nM, 10 nM, 5 nM and 6 nM for AA, DA, UA, and FA respectively Also, the obtained electrode can be used for the determination of the AA, DA, UA, and FA in human blood, and human urine real samples.

Diagnostic Utility of p63 (Ab-1) and (Ab-4) Tumor Markers in the Squamous Cell Carcinomas of Head and Neck

  • Khan, Nauman Rauf;Khan, Amna Nauman;Bashir, Saira;Khan, Ayyaz Ali;Suleman, Bilquis A.;Chaudhry, Saima
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.3
    • /
    • pp.975-978
    • /
    • 2012
  • P63 is a gene product required in cell cycle regulation which plays vital roles in tumor differentiation. Aims of the present study were to assess the frequency, pattern, sensitivity and specificity of two p63 protein clones P63 4A4 and P63 4A4+Y4A3 in squamous cell carcinomas (SCCs). Thirty cases of head and neck region SCC diagnosed on the basis of H&E staining were examined along with 60 cases of head and neck region biopsies other than squamous cell carcinoma, negative on H&E staining, were taken as control. Immunostaining was performed on slides according to the Thermo Scientific UltraVision LP detection System. P63 4A4+Y4A3 clone is more sensitive 96.6% in comparison to 86% in P63 4A4 with having greater NPV of 98.3%. The results signify the importance of P63 4A4+Y4A3 marker over the old markers and may be used as a confirmatory marker of squamous cell carcinoma.

Realtime Monitoring System using AJAX + XML (AJAX+XML 기반의 모니터링 시스템)

  • Choi, Yun Jeong;Park, Seung Soo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.4
    • /
    • pp.39-49
    • /
    • 2009
  • Nowadays, according to rapid development of computing environments, information processing and analysis system are very interesting research area. As a viewpoint of data preparation-processing-analysis in knowledge technology, the goal of automated information system is to satisfy high reliability and confidence and to minimize of human-administrator intervention. In addition, we expect the system which can deal with problem and abnormal error effectively as a fault detection and fault tolerance. In this paper, we design a monitoring system as follows. A productive monitoring information from various systems has unstructured forms and characteristics and crawls informative data by conditions and gathering rules. For representing of monitering information which requested by administrator, running-status can be able to check dynamically and systematic like connection/closed status in real-time. Our proposed system can easily correct and processing for monitoring information from various type of server and support to make objective judgement and analysis of administrator under operative target of information system. We implement semi-realtime monitering system using AJAX technology for dynamic browsing of web information and information processing using XML and XPATH. We apply our system to SMS server for checking running status and the system shows that has high utility and reliability.

AN IV CATHETER FRAGMENTS DURING MDCT SCANNING OF HUMAN ERROR: EXPERIMENTAL AND REPRODUCIBLE MICROSCOPIC MAGNIFICATION ANALYSIS

  • Kweon, Dae-Cheol;Lee, Jong-Woong;Choi, Ji-Won;Yang, Sung-Hwan;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.195-199
    • /
    • 2011
  • The use of intravenous catheters are occasionally complicated by intravascular fragments and swelling of the catheter fragments. We present a patient in whom an intravenous catheter fragments was retrieved from the dorsal metacarpal vein following its incidental CT examination detection. The case of demonstrates the utility of microscopy and multi-detector CT in localizing small of subtle intravenous catheter fragments as a human error. A case of IV catheter fragments in the metacarpal vein, in which reproducible and microscopy data allowed complete localization of a missing fragments and guided surgery with respect to the optimal incision site for fragments removal. These reproducible studies may help to determine the best course of action and treatment for the patient who presents with such a case.

An Electrical Installation Failure Signal Detection using Time-Energy Analysis (시간-에너지 분석을 이용한 전기설비 이상신호 검출)

  • Jee S. W.;Lee C. H.;Kim Ch. N.;Lee K. S.;Sim K. Y.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.2
    • /
    • pp.82-87
    • /
    • 2006
  • Most of electric accidents are happened in the place where activities are frequent by common people who has low electric knowledge. Also, accidents are increased in the low voltage electric equipment. So, it is increased to spread the dispersion or non-utility power generation system. It means that ordinary times observation is required for electric equipments by common people. This paper is studied for the diagnosis method of electric equipment that common people can diagnose easily Voltage is generally and exactly measured in the electric and electronic field. We suggest new analysis tools using only electric voltage. It is called the Time-Energy analysis. The Time-Energy analysis is as following First, divide measured voltage waves into same parts, Second, conducted FFT(Fast Fourier Transform) transform for each divided period, Finally, each results are reassembled after graphic treatment. We compared Time-Energy analysis with discharge form by tracking tester. As the result, tracking discharge processes distinguished clearly.