• Title/Summary/Keyword: utilities

Search Result 851, Processing Time 0.025 seconds

Application of System Dynamics Methodology for Comprehensive Analysis of the Water Business System (수도시스템 사업성과의 통합적 분석을 위한 시스템 다이나믹스 방법론 적용)

  • Lee, Sangeun;Park, Hyeyeon;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.65-73
    • /
    • 2007
  • To consider business-based requirements beyond the existing roles of water supply, water utilities need enough methodology to integrate lots of related issues and to introduce effective decision-makings. On these grounds, this study modeled and simulated water business system using system dynamics approach. It is expected that formalised model can describe the actual system structurally and statistically, help utilities to predict their business performance and make decisions to solve chronic issues. Moreover, the case study of Y city gave political measures objectively and practically.

Economic Analysis of Plant Utilities Under Environment Factor (환경요소를 고려한 발전설비의 경제성 평가에 관한 연구)

  • 정석재;송일윤;김경섭;박진원
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2003.06a
    • /
    • pp.149-154
    • /
    • 2003
  • 경제성장과 더불어 발생되는 환경오염물질 배출의 증가로 인해 이를 규제하려는 세계적인 동향이 강화되어 이러한 환경문제를 경제 내적인 문제로 발전하고 있다. 특히 전력부문에 있어서 여러 가지 투자대안들이 환경에 미치는 영향을 고려할 경우, 각 대안들이 전력을 생산하기 위해 필요한 비용은 사회적 비용을 고려치 않는 사적인 비용과 커다란 차이가 생길 수 있다. 이에 본 연구에서는 균등화발전 원가법으로 유연탄과 LNG화력 발전의 경제성을 분석하였는데. 환경 규제상황에서 발전원간 평가를 위해 저감설비 도입비용, 탄소세, 연료비 인상, 할인율 변동에 따른 경제성 비교를 통하여 유연탄 및 LNG발전의 발전원가를 컴퓨터 시뮬레이션에 의한 민감도 분석을 통해 비교하였다.

  • PDF

Development of A GIS-based Tunnelling-induced Building/Utility Damage Assessment System (GIS 기반의 터널굴착시 건물/매설관 손상평가 시스템 개발)

  • 유충식;김재훈;박영진;유정훈
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.311-318
    • /
    • 2002
  • A GIS-based tunnelling risk management system (GIS-TURIMS) has been developed in this study, The developed system uses ArcView 8.2 as a basic platform and the built-in interface (VBA) has been used to perform first-order simplified analyses for prediction of tunnelling-induced ground movements and building damage assessment. The main emphasis in this study was to develop a working framework that can be used in the perspective of tunnelling risk management. The developed system is capable of carrying out computationally intensive analyses for ground movement prediction as well as building/utilities damage assessment with fully taking advantage of the GIS technologies. This paper describes the concept and details of the GIS-TURIMS development and implementation

  • PDF

A Study on the Signal Analysis of Corona Discharge on the Polymer Insulator using UV Sensor Array (UV 센서 어레이를 이용한 폴리머 애자의 코로나 방전 신호분석 연구)

  • Choi, Myeong-Il;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.16-20
    • /
    • 2014
  • To prevent any accident in electric power utilities, many researches for inspection and diagnosis deteriorations occurring by corona discharges have been continuously studying. Inspection and diagnosis of electric power utility is very important to prevent an accident. This paper studies a measurement of ultra-violet(UV) ray of corona discharges on polymer insulators using an UV sensor array with an optic lens. The detection of an UV signal begins at 60kV, which is about 37.5% of the breakdown voltage of the polymer insulator and the stronger the high voltage increased to the polymer insulator was. It can be determined that the polymer insulator mounted on a live part must be examined when the discharge risk exceeds approximately 40%. In conclusion, the status of power utilities can be checked using an UV sensor.

A Study on AMI System of KEPCO (KEPCO의 지능형 원격검침 시스템에 대한 연구)

  • Myoung, No-Gil;Kim, Young-Hyun;Lee, Sang-Yeum
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.8B
    • /
    • pp.1251-1258
    • /
    • 2010
  • Major utilities have been focusing on R&D and business of AMI system which plays a vital role in SmartGrid whose concept is to optimize energy efficiency with exchanging real time information between utilities and consumers based on IT technologies in power grid. In this paper, we introduce KEPCO's AMI business plan, the AMI System architecture, designed core devices, communication networks and value added services, and also explore technical and business characteristics of KEPCO's AMI system.

An optimum algorithm for the economical construction of underground pipe-lines (지중배전공사의 경제적 시공을 위한 관로배열 최적화 알고리즘)

  • Cho, Seong-Soo;Kim, Jae-Hoon;Lee, Won-Young;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.183-185
    • /
    • 2004
  • Despite high cost, the underground power distribution system has been preferred by utilities and customers due to its stability and good living environment. Utilities, however, are burdened with the cost of installation as the service region of underground power system is getting enlarged. In this paper, a design method is proposed in order to reduce the construction cost of underground distribution system. That is an optimum algorithm, which can increase the total number of pipes in a limited space compared with a conventional design method. As a result, the proposed design method can reduce efficiently the construction cost of underground distribution system.

  • PDF

Residents' Evaluation for Rural Housing Environment (농가 주거환경 평가)

  • 김유일;윤진옥
    • Journal of Korean Society of Rural Planning
    • /
    • v.4 no.2
    • /
    • pp.79-88
    • /
    • 1998
  • The purpose of this study was to identify factors related to residential satisfaction, and to examine the rural housing and village environment which enable to derive what should be considered in the future rural housing improvement. Data were collected by questionnaire survey in 11 rural villages - suburban rural area, plain rural area, intermediate rural area, mountainous rural area. The major findings are as follows: 1) The rural residents rather dissatisfied with'management/maintenance','economic value','facade'in housing level, The overall housing satisfaction level was just medium(neither satisfied nordissatisfied). 2) They also dissatisfied with'playground for children','education condition','medical facilities', 'market'in village level. The overa'll village satisfaction level was just above average(slightly satisfied). 3) Vrom the result of ANOVA test, there are no significant differences in residents evaluation for tiousing and village attributes among 4 rural areas. 4) Factor analysis identified six rural housing environmental factors:'inside utilities','housing size' 'aesthetic aspects','safety','privacy','outside utilities'. 5) For the rural village environments six important factors were derived :'public services','commercial convenience facilities','social interaction','environmental pollution','amenity','agricultural service facilities'.

  • PDF

A Comparative Study of Maintenance Scheduling Methods for Small Utilities

  • Ong, H.L.;Goh, T.N.;Eu, P.S.
    • International Journal of Reliability and Applications
    • /
    • v.4 no.1
    • /
    • pp.13-26
    • /
    • 2003
  • This paper presents a comparative study of a few commonly used maintenance scheduling methods for small utilities that consists solely of thermal generating plants. Two deterministic methods and a stochastic method are examined. The deterministic methods employ the leveling of reserve capacity criterion, of which one uses a heuristic rule to level the deterministic equivalent load obtained by using the product of the unit capacity and its corresponding forced outage rate. The stochastic method simulates the leveling of risk criterion by using the peak load carry capacity of available units. The results indicate that for the size and type of the maintenance scheduling problem described In this study, the stochastic method does not produce a schedule which is significantly better than the deterministic methods.

  • PDF

Analysis of Perception of School Foodservice Facilities and Utilities in Gyeongnam Area by School Nutrition Teachers (Dietitians) -Comparison of School Foodservice Facilities and Improvement of Utilities in Schools- (경남지역 영양(교)사의 급식시설 설비에 대한 인지도 분석 -학교급식시설 현대화 사업 완료 학교와 미완료 학교의 비교를 중심으로-)

  • Jeon, Young;Kim, Hyun-Ah
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.9
    • /
    • pp.1447-1456
    • /
    • 2014
  • The purpose of this study was to compare perception of school foodservice facilities and utilities in dietitians and school nutrition teachers in the Gyeongnam area between schools that improved foodservice facilities and utilities versus those who did not. From July 23 to Aug 31, 2012, 391 questionnaires were distributed, and 289 questionnaires were obtained. A total of 275 questionnaires were used for the final analysis, excluding improper ones. The results of this study were as follows. First, among 275 schools, 90 schools (32.7%) improved school foodservice facilities and utilities while 175 schools (67.3%) did not. Second, schools with improved facilities had a more well-equipped receiving room (P<0.01), preparation room (P<0.001), dishwashing room (P<0.001), storage room for supplies (P<0.001), rest-room for school foodservice employees (P<0.05), locker room (P<0.01), shower room (P<0.001), laundry room (P<0.001), boiler room (P<0.05), and room for serving cart (P<0.05) than schools with no improvement. Third, total perception score of school foodservice facilities area from schools with improved facilities (1.71) was significantly higher than that (1.60) of school without improvement (P<0.001). Fourth, total satisfaction (3.32) of school foodservice facilities and utilities in school with improved facilities was significantly higher than that (2.62) of schools without improvement (P<0.01). Fifth, schools with improved facilities had a better equipped of floor (P<0.05), entrance (P<0.001), drain (P<0.001), water supply (P<0.01), lighting (P<0.001), hand washing (P<0.001), foodservice management room (P<0.001), locker room (P<0.001), rest-room and shower room (P<0.001), and preparation room (P<0.001) than schools without improvement. However, there was no significant difference in terms of walls and ceilings, windows, ventilation, and storage. In conclusion, school foodservice facilities and utilities improvement should conducted as soon as possible.