• Title/Summary/Keyword: using an analogy

Search Result 162, Processing Time 0.022 seconds

The analysis of planar optical waveguide using transmission line analogy (전송선 이론을 이용한 평면 광 도파관의 전파특성 해석)

  • Kwon, Bum;Park, Yong-Tae;Son, Tae-Ho;Lee, Sang-Seol
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.457-460
    • /
    • 1988
  • We present here a numerical solution for obtaining propagation characteristics including lossess for various modes of an multi-layered optical waveguide structure. The method is based on transmission line analogy. A comparison with other method shows the our results are accurate and simple.

  • PDF

Effective Thermal Conductivities of Fiber-Reinforce Composites Using a Thermal-Electrical Analogy (열-전기 유사성을 이용한 복합재료의 열전도도 예측)

  • 조영준;강태진;윤재륜
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.81-84
    • /
    • 2002
  • An approach for predicting the effective thermal conductivities of fiber-reinforce composite has been developed based on a thermal-electrical analogy. The unit cell of the composite laminate is divided into regular volume elements and the material properties have been given to each element. By constructing the series-parallel thermal resistance network, the thermal conductivities of composite both in-plane and out-of-plane direction have been predicted. Graphite/Epoxy composite is used for a balanced plain-weave composite laminate. By comparing the predicted results and the previous works, good agreement has been found.

  • PDF

Turbulence-induced noise of a submerged cylinder using a permeable FW-H method

  • Choi, Woen-Sug;Choi, Yoseb;Hong, Suk-Yoon;Song, Jee-Hun;Kwon, Hyun-Wung;Jung, Chul-Min
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.3
    • /
    • pp.235-242
    • /
    • 2016
  • Among underwater noise sources around submerged bodies, turbulence-induced noise has not been well investigated because of the difficulty of predicting it. In computational aeroacoustics, a number of studies has been conducted using the Ffowcs Williamse-Hawkings (FW-H) acoustic analogy without consideration of quadrupole source term due to the unacceptable calculation cost. In this paper, turbulence-induced noise is predicted, including that due to quadrupole sources, using a large eddy simulation (LES) turbulence model and a developed formulation of permeable FW-H method with an open source computational fluid dynamics (CFD) tool-kit. Noise around a circular cylinder is examined and the results of using the acoustic analogy method with and without quadrupole noise are compared, i.e. the FW-H method without quadrupole noise versus the permeable FW-H method that includes quadrupole sources. The usability of the permeable FW-H method for the prediction of turbulence-noise around submerged bodies is shown.

Students' Alternative Conceptions of Plate Boundaries and Their Conception Revision According to Their Reasoning Patterns

  • Park, Su-Kyeong
    • Journal of the Korean earth science society
    • /
    • v.35 no.5
    • /
    • pp.385-398
    • /
    • 2014
  • This study investigated students' alternative conceptions of plate boundaries and their conception revision according to the pattern of students' reasoning. Participants were twenty-two 10th grade high school students. All participants were asked to draw the three types of plate boundaries and to explain their drawings. Nine students participated in the reasoning activity. To this end, a semi-structured interview was conducted during which key questions were asked for the students to individually answer. The key questions used in the reasoning activity were created, by utilizing questions used in the previous studies. The findings revealed that the alternative conceptions of plate boundaries were classified into three levels based on established criteria. Students who attempted a variety of reasoning strategies such as causal reasoning, using an analogy, abductive reasoning, data reconstruction and concept combination, revised their alternative conception to a scientific conception after the reasoning activity. On the other hand, some students could not revise their alternative conceptions because they only conducted an incomplete reasoning strategy. The study also found that they were unable to use other reasoning strategies, either.

Solubility and Diffusivity of CS2 in DEA Solution

  • Park, Moon-Ki;Moon, Yung-Soo;Park, Jong-Kil
    • Journal of Environmental Science International
    • /
    • v.12 no.5
    • /
    • pp.551-557
    • /
    • 2003
  • An experimental study of the absorption of CS$_{2}$ in the secondary amine diethanolamine(DEA) was performed in this work. The primary objectives were to investigate an analogy between N2O and CS$_{2}$ permitting estimation of the physical solubility and diffusivity of the sulfur gases in the reacting amino solutions. The solubilities of CS$_{2}$ in water at 25, 40 and 6$0^{\circ}C$ has been measured. The data show fair agreement with previous literature values. The solubility of CS$_{2}$ in 5-25 weight % polyethylene glycol has been measured in order to investigate a possible analogy between CS$_{2}$ and N$_{2}$O The diffusivities of CS$_{2}$ in water and the reaction rate between CS$_{2}$ and DEA has been measured at 25 and 4$0^{\circ}C$, using a wetted sphere apparatus operated at approximately 1/3 atmospheres pressure, which is a previously untried method.

Development of an Electric Circuit Transient Analogy Model in a Vertical Closed Loop Ground Heat Exchanger (수직밀폐형 지중열교환기의 회로 과도해석 상사모델 개발)

  • Kim, Won-Uk;Park, Hong-Hee;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.306-314
    • /
    • 2012
  • Several numerical or analytical models have been proposed to analyze the thermal response of vertical ground heat exchangers (GHEX). However, most models are valid only after several hours of operation since they neglect the heat capacity of the borehole. Recently, the short time response of the GHEX became important in system simulation to improve efficiency. In this paper, a simple new method to evaluate the short time response of the GHEX by using an analogy model of electric circuit transient analysis was presented. The new transient heat exchanger model adopting the concept of thermal capacitance of the borehole as well as the steady-state thermal resistance showed the transient thermal resistance of the borehole. The model was validated by in-situ thermal response test and then compared with the DST model of the TRNSYS program.

A Study on Teaching Methods of Extension of Cosine Rule Using Analogy (유추를 활용한 코사인 법칙의 일반화 지도방안)

  • Kim, Sungsoo;Park, Dal-Won
    • Journal of the Korean School Mathematics Society
    • /
    • v.16 no.4
    • /
    • pp.927-941
    • /
    • 2013
  • In this paper, we investigate and analysis high school students' generalization of cosine rule using analogy, and we study teaching and learning methods improving students' analogical thinking ability to improve mathematical thinking process. When students can reproduce what they have learned through inductive reasoning process or analogical thinking process and when they can justify their own mathematical knowledge through logical inference or deductive reasoning process, they can truly internalize what they learn and have an ability to use it in various situations.

  • PDF

Solubility of Hydrogen Sulfide in Aqueous Solutions of Methyldiethanolamine and diethanolamine

  • Park, Moon-Ki;Moon, Yung-Soo;Kim, Jung-Ho
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.2
    • /
    • pp.131-136
    • /
    • 1999
  • The solubility of H2S is an important parameter for modeling H2S absorption. Since the direct measurement of H2S solubility in aqueous amine solutions is impossible, this work initially attempted to develop an H2S analogy method, however, this was unsuccessful. Consequently, H2S solubilities were measured in aqueous amines which were completely protonated with HCI over a temperature range of 25-60℃. The solvents investigated in this work included 0-50% aqueous solutions of methyldiethanolamine and diethanolamine. Thereafter, a new empirical correlation was developed that can predict Henry's constant for H2S using only the solubility of H2S in water and t도 molecular weight of the aqueous solvent.

  • PDF

Power Flow Analysis for Manufacturing of Planetary Gears in an 8-speed Automatic Transmission (II): 4-8 Speeds (8단 자동변속기의 유성기어 가공을 위한 동력 흐름 해석 (2) : 4-8단)

  • Lee, Kyoung-Jin;Kim, Jeong-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.5
    • /
    • pp.57-65
    • /
    • 2016
  • The power flow of an 8-speed automatic transmission was analyzed using a lever analogy for the manufacturing of planetary gears. From the analysis, we found that the engine power was split between the first and second double-pinion planetary gears (DPPG1 and DPPG2), and was then passed to the DPPG3 for the fourth speed. For the fifth speed, the engine power was split between the DPPG1 and DPPG3. For the speeds 6-8, the engine power was passed only to SPPG2, while the seventh speed contained the power circulation.

A Study on the Analysis and Improvement of the Acoustic Characteristics of the Muffler with Complex Geometry (복잡한 형상의 머플러 음향특성 해석 및 개선에 관한 연구)

  • 오상경;모진용;허만선
    • Journal of KSNVE
    • /
    • v.6 no.6
    • /
    • pp.755-762
    • /
    • 1996
  • An acoustic transmission loss analysis method for mufflers with complex geometry is developed using MSC/NASTRAN on the basis of acoustic-structural analogy and two-microphone method. In this study, mufflers with simple and complex shapes are analyzed using this method and compared with theoretical and experimental results to verify it. Applying this method to design of discharge muffler in a rotary compressor, we obtained 2dB(A) of noise reduction in the range of lower than 1300Hz. Futhermore, adopting this technique for a suction muffler in reciprocal compressor, more than 10dB(A) noise reduction at 500Hz, and in total, 3dB(A) noise reduction is achieved.

  • PDF