• Title/Summary/Keyword: used shortening

Search Result 409, Processing Time 0.024 seconds

Characterization of Electrochromic Properties of Au Nanoparticles Incorporated Poly (3, 4-ethylenedioxythiphene) Film (Au 나노입자가 함침된 Poly (3, 4-ethylenedioxythiphene) 고분자 박막의 전기변색 특성연구)

  • Lee, Jong-Seok;Koo, Kyoung-Hoe;Park, Hyung-Ho
    • Korean Journal of Materials Research
    • /
    • v.19 no.10
    • /
    • pp.527-532
    • /
    • 2009
  • The electrochromic properties of Au nanoparticles (NPs) incorporating poly (3, 4-ethylenedioxythiphene) (PEDOT) film were investigated. Trisodium citrate was used for stabilizing Au NPs to control the size. The capping molecules of the Au nanoparticles were exchanged from citrate to 2-mercaptoethanol (2-ME). Water was removed by centrifuge and Au NPs were redispersed in methanol (MeOH). Finally, we obtained ca. 11.7 nm diameter of Au NPs. The effects of 0.15 at% of Au NPs incorporation on the optical, electrical, and eletrochromic properties of PEDOT films were investigated. The electrical property and switching speed of Au/PEDOT film was slightly improved over that of PEDOT film because Au NPs play a hopping site role and affect packing density of the PEDOT chain. Through the ultra violet-visible spectra of PEDOT and Au/PEDOT films at -0.7 V (vs Ag/AgCl), blue shift of maximum absorption peak was observed from PEDOT (585.4 nm) to Au/PEDOT (572.2 nm) due to a shortening of conjugated length of PEDOT. The Au NPs interfered with the degree of conjugation and the maximum absorption peak was shifted to shorter wavelength.

Effect of Na, K, Ca and Mg ions on the Action Potential of the Sinoatrial Node in the Rabbit (토끼 동방결절 활동전압에 대한 Na, K, Ca 및 Mg 이온의 영향)

  • Lee, Jeong-Ryeol;Eom, Yung-Ui
    • Journal of Chest Surgery
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 1985
  • Isolated sinus node cells of the rabbit were used to assess the effects of extracellular Na, K, Ca and Mg concentrations on cardiac pacemaker activity. With intracellular glass micro-electrodes spontaneous action potentials of SA node were recorded and the effects of various ions and their blockers were analyzed in terms of the cycle length, the amplitude and the duration of action potentials, the results obtained were as follows. 1. Sodium reduction [up to 30%] decreased the amplitude of action potential and lengthened the cycle length. TTX, specific blocker of Na channel slightly lengthened the cycle length. 2. Increasing potassium ion concentration, the duration of action potential decreased and the frequency increased in 6mM, however, spontaneous action potential was stopped in 24 mM. Barium ion known to be decreasing K conductance increased the duration of action potential but no significant change in the cycle length was noticed. 3. Calcium ion has shortening effect on the duration and the cycle length of action potential but not with dose-dependent manner. Cadmium ion .[0.02mM] lengthened cycle length and the duration of action potential. 4. Increasing the concentration of magnesium ion the cycle length was lengthened, significantly.

  • PDF

Practical Design Issues in a Linear Feedback Control System with a Notch Filter (선형 피드백 제어계의 노치필터 설계에 대한 실제적 문제)

  • Jin, Lihua;Kim, Young-Chol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.176-183
    • /
    • 2010
  • This paper presents some practical design issues that should be carefully considered when a notch filter is included in a linear feedback controller. A notch filter is generally used to compensate the effects of resonant modes that may result in poor performance. It is very common that the practical engineers prefer to add such a notch filter after having previously designed a feedback controller without the filter. It is known that the resulting performance by this approach is not seriously different from when a feedback controller is designed for a plant previously compensated by a notch filter. However, we will point out that there are some cases where both approaches have different performances. In order to show this, a low-order controller design using the partial model matching method has been applied to a linear time invariant (L Tn model. The results suggest that there is a tendency to achieve much better time responses in terms of reducing the overshoot and shortening the settling time, and in the frequency domain characteristics such as the sensitivity function and the stability margins when the design of a feedback controller after including a notch filter is carried out.

Feed forward Differential Architecture of Analog Parallel Processing Circuits for Analog PRML Decoder (아날로그 PRML 디코더를 위한 아날로그 병렬처리 회로의 전향 차동 구조)

  • Sah, Maheshwar Pd.;Yang, Chang-Ju;Kim, Hyong-Suk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1489-1496
    • /
    • 2010
  • A feed forward differential architecture of analog PRML decoder is investigated to implement on analog parallel processing circuits. The conventional PRML decoder performs the trellis processing with the implementation of single stage in digital and its repeated use. The analog parallel processing-based PRML comes from the idea that the decoding of PRML is done mainly with the information of the first several number of stages. Shortening the trellis processing stages but implementing it with analog parallel circuits, several benefits including higher speed, no memory requirement and no A/D converter requirement are obtained. Most of the conventional analog parallel processing-based PRML decoders are differential architecture with the feedback of the previous decoded data. The architecture used in this paper is without feedback, where error metric accumulation is allowed to start from all the states of the decoding stage, which enables to be decoded without feedback. The circuit of the proposed architecture is simpler than that of the conventional analog parallel processing structure with the similar decoding performance. Characteristics of the feed forward differential architecture are investigated through various simulation studies.

Study on Soft-Switching Transformers Inductor Boost Converter for Fuel Cell Powered Railway Vehicle

  • Jung, No-Geon;Kim, Jae-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2553-2560
    • /
    • 2018
  • In Korea, there are no instances where a hydrogen fuel cell power generation system has been used in a railway vehicle. Only the basic topology has been studied. In the previous study, conventional converters using a single switch were applied to the fuel cell power generation system. Therefore, current stress on the switch at converter on-off transitions would be large when controlling a large-capacity railway vehicle. In addition, since the input side ripple is also large, there is a problem with a shortening of the lifetime of both the fuel cell power generation system and the inductor. In this paper, a soft-switching transformer inductor boost converter for fuel cell powered railway vehicles was proposed. A technique to reduce both the switching current stress generated during on-off transitions, and the input ripple current flowing in the inductor were studied. The soft-switching TIB converter uses a transformer-type inductor to configure the entire circuit in an interleaved method, and reduces both input current ripple and the current ripple of the inductor and switch.

Evaluation of a Possibility of Estimation of Reaction Force of Surgical Robot Instrument using Sliding Perturbation Observer (슬라이딩 섭동 관측기를 이용한 수술용 로봇 인스트루먼트의 반력 추정 가능성 평가)

  • Yoon, Sung-Min;Lee, Min-Cheol;Kim, Chi-Yen;Kang, Byeong-Ho
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.1
    • /
    • pp.20-28
    • /
    • 2012
  • In spite of the difficulties and uncertain characteristic of cable driven method, surgical robot instrument has adopted it as driving mechanism for various reasons. To overcome the problem of cable system, previous research applied SMCSPO (sliding mode control with sliding perturbation observer) algorithm as robust controller to control the instrument and found that the value of SPO (sliding perturbation observer) followed force disturbance, reaction force loaded on the tip very similarly. Thus, this paper confirms that the perturbation observer is sufficient estimator which finds out the mount of loaded force on the surgical robot instrument. To prove the proposition, simulation using the similar model with an actual instrument and experimental evaluation are performed. The results show that it is possible to substitute SPO for sensors to measure the reaction force. This estimated reaction force will be used to realize haptic function by sending the reaction force to a master device for a surgeon. The results will contribute to create surgical benefit such as shortening the practice time of a surgeon and giving haptic information to surgeon by using it as haptic signal to protect an organ by making force boundary.

Electronic Blasting Case Study Method Using Deck Charge (분상장약공법을 이용한 전자발파 시공사례)

  • Kim, Gab-Soo;Son, Young-Bok;Kim, Jae-Hoon;Choi, Hyung-Bin
    • Explosives and Blasting
    • /
    • v.33 no.1
    • /
    • pp.27-34
    • /
    • 2015
  • Recently, the residence complaints have been increased by blast vibration and noise issue due to increased urban blasting works so that the trouble between construction company and residence have been continuously increased. Deck-charge blasting method using electronic detonator provided not only blast vibration and noise control but also minimized residence complaints through shortening of the blasting period. This blasting method will be widely used for maximizing urban blasting productivity.

A Study on the development of high-fiber supplements for the diabetic patients (I) -Effect of Seaweed Supplementation on the Gastrointestinal Function and Diabetic Symptom Control in Streptozotocin-induced Diabetic Rats- (당뇨병 환자를 위한 고식이섬유 보충물의 개발을 위한 연구(I) -해조류 투여가 당뇨쥐의 장기능과 증세호전도에 미치는 영향-)

  • 이혜성
    • Journal of Nutrition and Health
    • /
    • v.29 no.3
    • /
    • pp.286-295
    • /
    • 1996
  • The present study was conducted to evaluate the usefulness of four kinds of seaweeds (mixture of purple laver & sea lettuce, sea tangle, sea mustard, agar agar) as a high- fiber supplment in the therapeutic deit for the diabetic patients. Seven groups of normal and streptozotocin-induced diabetic rats were fed dietary fiber-free control diet or one of experimental diets containing 7% of one of the four seaweeds for 6 weeks. The effect of seaweeds supplementation on the body weight change, gastrointestinal function, and the control of diabetic symptoms were examined and compared with the effect of fiber-free diet or pectin diet used as references. The body weight gains of all the diabetic groups were significantly suppressed compared to the normal group. Feed efficiency ratios and body weight gains of seaweed groups were relatively higher than those of the pectin group. Sea tangle appeared to have an effect of alleviating the typical diabetic symptoms such as polyphasia, polydipsia, polyuria, urinary glucose excretion and hyperglycemia indicating its beneficial acition of improving glucose metabolism even though the degree of effectiveness was less than that with pectin. All the supplemntations of seaweeds and pectin ressulted in the significant changes in gastronitestinal functins ; shortening of GI transit time, increase of fecal volume and the length of intestine. Based on their effects of the significant changes in GI function in may be suggested that seaweeds may influence the process of digestion and absorption of nutrients in diabetic animals.

  • PDF

Mitigation of seismic drift response of braced frames using short yielding-core BRBs

  • Pandikkadavath, Muhamed Safeer;Sahoo, Dipti Ranjan
    • Steel and Composite Structures
    • /
    • v.23 no.3
    • /
    • pp.285-302
    • /
    • 2017
  • Buckling-restrained braced frames (BRBFs) are commonly used as the lateral force-resisting systems in building structures in the seismic regions. The nearly-symmetric hysteretic response and the delayed brace core fracture of buckling-restrained braces (BRBs) under the axial cyclic loading provide the adequate lateral force and deformation capacity to BRBFs under the earthquake excitation. However, the smaller axial stiffness of BRBs result in the undesirable higher residual drift response of BRBFs in the post-earthquake scenario. Two alternative approaches are investigated in this study to improve the elastic axial stiffness of BRBs, namely, (i) by shortening the yielding cores of BRBs; and (ii) by reducing the BRB assemblies and adding the elastic brace segments in series. In order to obtain the limiting yielding core lengths of BRBs, a modified approach based on Coffin-Manson relationship and the higher mode compression buckling criteria has been proposed in this study. Both non-linear static and dynamic analyses are carried out to analytically evaluate the seismic response of BRBFs fitted with short-core BRBs of two medium-rise building frames. Analysis results showed that the proposed brace systems are effective in reducing the inter-story and residual drift response of braced frames without any significant change in the story shear and the displacement ductility demands.

A brief report on a technical description of ultrasound-guided lumbar sympathetic block

  • Moon, Jee Youn;Choi, Jae Kyu;Shin, Ji Yeon;Chon, Sung Won;Dev, Sushmitha
    • The Korean Journal of Pain
    • /
    • v.30 no.1
    • /
    • pp.66-70
    • /
    • 2017
  • The lumbar sympathetic ganglion block (LSGB) is widely used for diagnosing and treating sympathetically maintained pain disorders. The LSGB has been conventionally carried out under fluoroscopy or computed tomography guidance. However, as ultrasound technology improved, ultrasound-guided interventions have been expanding their territory to deeper structures. Ultrasound guidance provides many benefits including protecting vascular injection, shortening procedure time in some cases, and reducing the emission of radiation. In this report, we describe a successful case of a US-guided LSGB without major complications. We expect that US-guided LSGBs can be implemented and furnished in the daily outpatient clinical setting by highly trained pain physicians.