• 제목/요약/키워드: used shortening

검색결과 409건 처리시간 0.021초

Age Prediction in the Chickens Using Telomere Quantity by Quantitative Fluorescence In situ Hybridization Technique

  • Kim, Y.J.;Subramani, V.K.;Sohn, S.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제24권5호
    • /
    • pp.603-609
    • /
    • 2011
  • Telomeres are special structures at the ends of eukaryotic chromosomes. Vertebrate telomeres consist of tandem repeats of conserved TTAGGG sequence and associated proteins. Birds are interesting models for molecular studies on aging and cellular senescence because of their slow aging rates and longer life spans for their body size. In this longitudinal study, we explored the possibility of using telomeres as an age-marker to predict age in Single Comb White Leghorn layer chickens. We quantified the relative amount of telomeric DNA in isolated peripheral blood lymphocytes by the Quantitative Fluorescence in situ Hybridization technique on interphase nuclei (IQ FISH) using telomere-specific DNA probes. We found that the amount of telomeric DNA (ATD) reduced significantly with an increase in chronological age of the chicken. Especially, the telomere shortening rates are greatly increased in growing individuals compared to laying and old-aged individuals. Therefore, using the ATD values obtained by IQ FISH we established the possibility of age prediction in chickens based on the telomere theory of aging. By regression analysis of the ATD values at each age interval, we formulated an equation to predict the age of chickens. In conclusion, the telomeric DNA values by IQ FISH analyses can be used as an effective age-marker in predicting the chronological age of chickens. The study has implications in the breeding and population genetics of poultry, especially the reproductive potential.

Wilshire Grand: Outrigger Designs and Details for a Highly Seismic Site

  • Joseph, Leonard M.;Gulec, C. Kerem;Schwaiger, Justin M.
    • 국제초고층학회논문집
    • /
    • 제5권1호
    • /
    • pp.1-12
    • /
    • 2016
  • The 1100 foot [335 m] tall Wilshire Grand Center tower under construction in Los Angeles illustrates many key outrigger issues. The tower has a long, narrow floor plan and slender central core. Outrigger braces at three groups of levels in the tower help provide for occupant comfort during windy conditions as well as safety during earthquakes. Because outrigger systems are outside the scope of prescriptive code provisions, Performance Based Design (PBD) using Nonlinear Response History Analysis (NRHA) demonstrated acceptability to the Los Angeles building department and its peer review panel. Buckling Restrained Brace (BRB) diagonals are used at all outrigger levels to provide stable cyclic nonlinear behavior and to limit forces generated at columns, connections and core walls. Each diagonal at the lowest set of outriggers includes four individual BRBs to provide exceptional capacities. The middle outriggers have an unusual 'X-braced Vierendeel' configuration to provide clear hotel corridors. The top outriggers are pre-loaded by jacks to address long-term differential shortening between the concrete core and concrete-filled steel perimeter box columns. The outrigger connection details are complex in order to handle large forces and deformations, but were developed with contractor input to enable practical construction.

한국판 5요인 마음챙김 단축형 척도 타당화 연구 (The Validation of Korean Version of Five Facet Mindfulness Questionnaire Short Form)

  • 정문주;채은영;류영수;강형원
    • 동의신경정신과학회지
    • /
    • 제28권3호
    • /
    • pp.207-216
    • /
    • 2017
  • Objectives: To simplify the mindfulness scale and to ensure reliability and validity of the scale. Methods: To develop scale items using the original scale and to identify factor structure of the scale, exploratory factor analysis was conducted based on results of factor analysis, the short-form 5-factor mindfulness scale item was selected. Internal consistency coefficient was calculated and confirmatory factor analysis was conducted to verify reliability of the short-form scale. Finally, to verify validity of the abbreviated scale, we conducted correlation analysis with the abbreviated scale and the mindfulness scale (FFMQ). Results: As with the original scales, scaled scales were composed of 5 factors and consisted of 15 items in total. Factor analysis revealed factor loadings were adequate and reliability and validity were secured. Conclusions: It provided that mindfulness shortening scale validation can be used more simply to measure mindfulness in the clinical scene.

Short Humeral Stems in Shoulder Arthroplasty

  • Oh, Hwang Kyun;Lim, Tae Kang
    • Clinics in Shoulder and Elbow
    • /
    • 제21권2호
    • /
    • pp.105-110
    • /
    • 2018
  • Since the introduction of shoulder arthroplasty by Neer in 1974, the design of not only the glenoid component but also the humeral component used in shoulder arthroplasty has continually evolved. Changes to the design of the humeral component include a gradually disappearing proximal fin; diversified surface finishes (such as smooth, grit-blasted, and porous coating); a more contoured stem from the originally straight and cylindrical shape; and the use of press-fit uncemented fixation as opposed to cemented fixation. Despite the evolution of the humeral component for shoulder arthroplasty, however, stem-related complications are not uncommon. Examples of stem-related complications include intraoperative humeral fractures, stem loosening, periprosthetic fractures, and stress shielding. These become much more common in revision arthroplasty, where patients are associated with further complications such as surgical difficulty in extracting the humeral component, proximal metaphyseal bone loss due to stress shielding, intraoperative humeral shaft fractures, and incomplete cement removal. Physicians have made many attempts to reduce these complications by shortening the stem of the humeral component. In this review, we will discuss some of the limitations of long-stem humeral components, the feasibility of replacing them with short-stem humeral components, and the clinical outcomes associated with short-stemmed humeral components in shoulder arthroplasty.

Performance of lightweight aggregate and self-compacted concrete-filled steel tube columns

  • AL-Eliwi, Baraa J.M.;Ekmekyapar, Talha;Faraj, Radhwan H.;Gogus, M. Tolga;AL-Shaar, Ahmed A.M.
    • Steel and Composite Structures
    • /
    • 제25권3호
    • /
    • pp.299-314
    • /
    • 2017
  • The aim of this paper is to investigate the performance of Lightweight Aggregate Concrete Filled Steel Tube (LWCFST) columns experimentally and compare to the behavior of Self-Compacted Concrete Filled Steel Tube (SCCFST) columns under axial loading. Four different L/D ratios and three D/t ratios were used in the experimental program to delve into the compression behaviours. Compressive strength of the LWC and SCC are 33.47 MPa and 39.71 MPa, respectively. Compressive loading versus end shortening curves and the failure mode of sixteen specimens were compared and discussed. The design specification formulations of AIJ 2001, AISC 360-16, and EC4 were also assessed against test results to underline the performance of specification methods in predicting the compression capacity of LWCFST and SCCFST columns. Based on the behaviour of the SCCFST columns, LWCFST columns exhibited different performances, especially in ductility and failure mode. The nature of the utilized lightweight aggregate led to local buckling mode to be dominant in LWCFST columns, even the long LWCFST specimens suffered from this behaviour. While with the SCCFST specimens the global buckling governed the failure mode of long specimens without any loss in capacity. Considering a wide range of column geometries (short, medium and long columns), this paper extends the current knowledge in composite construction by examining the potential of two promising and innovative structural concrete types in CFST applications.

사출금형의 냉각회로 종류에 따른 냉각효율의 비교 (Comparison of cooling effects according to cooling methods in injection mold)

  • 노건철;장민규;제덕근;최윤식;정영득
    • Design & Manufacturing
    • /
    • 제8권1호
    • /
    • pp.10-13
    • /
    • 2014
  • Plastic products are producted more than 70% of total processes by the injection molding. The injection molding process has 4 processes such as filling, packing, cooling and ejecting. It spends most of times in the cooling process. Therefore, it is important to control the mold temperature in producing plastic products. The time and system of cooling affect the product's quality and productivity. Especially, cooling time has about 60% of total injection cycle time. Therefore, we can improve a productivity by shortening cooling time. This study shows comparative study about cooling efficiency of spiral channel and baffle and observed the variation of time to freeze of molding As the result of CAE experiments, cooling rate by spiral channel had faster than baffle and as freeze time was decreased. Results of this study will be used widely to design for cooling system of injection mold.

  • PDF

진동 교반기가 있는 미소채널에서 혼합에 대한 Karman 와의 영향 (The Effect of Karman Vortex for Mixing in a Micro-channel with an Oscillating Micro-stirrer)

  • 안상준;맹주성;김용대
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.144-152
    • /
    • 2006
  • In order to consider the effect of Karman vortex for mixing, mixing indices are calculated for 4 models of micro channel flows driven from the combinations of a circular cylinder and a oscillating stirrer. And their results are compared to that of a simple straight micro channel flow(model I). The mixing rate is improved 5.5 times by Karman vortex (model II) and 11.0 times by the stirrer(model III) respectively. In case of successive mixing by the cylinder and the stirrer(model IV), $27\%$ of shortening the channel length for the complete mixing as well as 1.37 times improvement of mixing efficiency then model III. And then, variation of mixing indices are much stable comparing with the others. Thus, it is found that the Karman vortex plays a good role as a pre-mixing method. The D2Q9 Lattice Boltzmann methods are used.

편집자 직접 조판을 위한 CTS설계 (The Design of CTS for an Editor's Composition)

  • 유경택;박홍준;맹기재
    • 한국컴퓨터정보학회논문지
    • /
    • 제3권1호
    • /
    • pp.13-23
    • /
    • 1998
  • 70년대 사식 시스템을 신문 제작에 도입한 이후 CTS(Computerized Typesetting System)에는 많은 변화와 발전이 있어 왔다. CTS는 HT(Hot Plate Type)방식에 비해 제작 시간의 단축, 레이아웃 다양화, 편집 모양의 자유로운 변경, 공해 요인의 제거등 많은 장점을 제공한다. 그러나, 신문은 경쟁 매체의 등장, 이윤 추구라는 경제 원리의 확대등 새로운상황에 직면해 있으며, 이를 교열부의 축소 및 페지를 통한 경비 절감과 신속한 지면 제작을 위한 편집자 직접 조판으로 해결하고자 한다. 본 논문은 편집자 직접 조판을 위한 기본요건과 기술 마크업에 근거한 CTS의 설계에 대하여 기술한다.

  • PDF

사출성형금형에서 직선채널과 배플의 냉각효율 비교 (Comparison of Linear Channel and Baffle for Cooling Rate in Injection Mold)

  • 문영배;최윤식;정영득
    • Design & Manufacturing
    • /
    • 제6권1호
    • /
    • pp.1-4
    • /
    • 2012
  • Plastic products are producted more than 70% of total processes in the injection molding. The injection molding process has 4 processes such as filling, packing, cooling and ejecting. It spends most of times in the cooling process. Therefore, it is important to control the mold temperature in producing plastic products. The time and system of cooling affect the product's quality and productivity. Especially, cooling time has about 60% of total injection cycle time. Therefore, we can improve a productivity by shortening cooling time. In this study, it was made a comparative study about cooling of linear channels and baffles and observed the variation of mold temperature on the coolant's temperature. As the result, the linear channel's cooling rate had faster than baffles and as coolant's temperature was increased, difference of cooling time was increased. Result of this study will be used widely to design for cooling system of injection mold.

  • PDF

요추부 염좌로 진단받은 환자에 대한 Sweet Bee Venom 병행 치료와 단독 침 치료의 효과 비교 (A Clinical Pilot Study Comparing Sweet Bee Venom parallel treatment with only Acupuncture Treatment in patient diagnosed with lumbar spine sprain)

  • 신용진
    • 대한약침학회지
    • /
    • 제14권2호
    • /
    • pp.37-43
    • /
    • 2011
  • Objectives : This study was carried out to compare the Sweet Bee Venom (referred to as Sweet BV hereafter) acupuncture parallel treatment to treatment with acupuncture only for the patient diagnosed with lumbar spine sprain and find a better treatment. Methods : The subjects were patients diagnosed with lumbar spine sprain and hospitalized at Suncheon oriental medical hospital, which was randomly divided into sweet BV parallel treatment group and acupuncture-only group, and other treatment conditions were maintained the same. Then, VAS (Visual Analogue Scale) was used to compare the difference in the treatment period between the two groups from VAS 10 to VAS 0, from VAS 10 to VAS 5, and from VAS 5 to VAS 0. Result & Conclusion : Sweet BV parallel treatment group and acupuncture-only treatment group were compared regarding the respective treatment period, and as the result, the treatment period from VAS 10 to VAS 5 was significantly reduced in sweet BV parallel treatment group compared to the acupuncture-only treatment group, but the treatment period from VAS 5 to VAS 0 did not show a significant difference. Therefore, it can be said that sweet BV parallel treatment is effective in shortening the treatment period and controlling early pain compared to acupuncture-only treatment.