Evaluation and Design of Infiltration and Filtration BMP Facility (침투 여과형 비점오염저감시설의 설계 및 평가)

  • Choi, Ji-Yeon;Maniquiz, Marla Chua;Lee, So-Young;Kang, Chang-Guk;Lee, Jung-Yong;Kang, Hee-Man;Kim, Lee-Hyung
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.5
    • /
    • pp.475-481
    • /
    • 2010
  • Lots of pollutants typically originating from urban transportation are accumulating on the paved surfaces during dry periods and are washed-off directly to the river during a storm. Also, paved surfaces are contributing to increase in peak flows and volume of stormwater flows. These are the main reasons why the water quality of rivers and lakes remain polluted and still below standards. Currently, several management practices are being applied in developed countries but the design standards are still lacking. This research was conducted to develop a treatment technology that can be useful to address the problems concerning runoff quality and quantity. A lab scale infiltration device consisting of a pretreatment tank and media zone was designed and tested for various flow regimes characterizing the low, average and high intensity rainfall. Based on the experiments, the high intensity flow resulted to increase in outflow event mean concentration (EMC) of pollutants, about twice as much as the average outflow EMC. However, 78 to 88% of the total suspended solids were captured and retained in the pretreatment tank because of sedimentation. The removal of heavy metals such as zinc and lead was greatly affected by the vertical placement of woodchip layer prior to the media zone. It was observed that the high carbon content (almost 50%) in the woodchip provided opportunity for enhancing its uptake of metal by adsorption. The findings implied that the reduction of pollutants can be greatly achieved by means of proper pretreatment to allow for settling of particles with a combination of using high carbon source media like woodchip and a geotextile mat to reduce the flow before filtering into the media zone and finally discharging to the drainage system.

A Derivation of Rainfall Intensity-Duration-Frequency Relationship for the Design of Urban Drainage System in Korea (우리나라 도시배수시스템 설계를 위한 확률강우강도식의 유도)

  • Lee, Jae-Jun;Lee, Jeong-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.4
    • /
    • pp.403-415
    • /
    • 1999
  • This study is to derive the rainfall intensity formula based on the representative probability distribution in Korea. The 11 probability distributions which has been widely used in hydrologic frequency analysis are applied to the annual maximum rainfall. The parameters of each probability distribution are estimated by method of moments, maximum likelihood method and method of probability weighted moments. Four tests such as $x^2$-test, Kolmogorv-Smirnov test, difference test and modified difference test are used to determine the goodness of fit of the distributions. The homogeneous tests (Mann-Whitney U test, Kruskal-Wallis one-way analysis of variance of nonparametric test) are applied to find the stations with rainfall homogeneity. The results of homogeneous tests show that there is no representative appropriate distribution for the whole duration in Korea. The whole region could be divided into five zones for 12-durations. The representative probability distribution of each divided zone for 12-durations was determined. The GEV distribution for I,II,V zones and the 3-parameter Weibull distribution for III,IV zones were determined as the representative probability distribution. The rainfall were obtained from representative probability distribution for the selected return periods. Rainfall intensity formula was determined by linearization technique for the rainfall.

  • PDF

A Study on Rainfall-Pattern Analysis for determination of Design flow in small watershed (소유역의 설계유량 산정을 위한 강우현상 분석에 관한 연구)

  • 박찬영;서병우
    • Water for future
    • /
    • v.14 no.4
    • /
    • pp.13-18
    • /
    • 1981
  • The rainfall pattern analysis on time distribution characteristics of rainfall rates in important in determination of design flow for hydraulic structures, particularly in urban area drainage network system design. The historical data from about 400 storm samples during 31 years in Seoul have been used to investigate the time distribution of 5-minute rainfall in the warm season. Time distribution relations have been deveolped for heavy stroms over 20mm in total rainfall and represented by relation percentage of total storm rainfall to percentage of total storm time and grouping the data according to the quartile in which rainfall was heaviest. And also time distribution presented in probability terms to provide quantitative information on inter-strom variability. The resulted time distribution relations are applicable to construction of rainfall hyetograph of design storm for determination of design flow hydrograph and identification of rainfall pattern at given watershed area. They can be used in conjuction with informations on spatstorm models for hydrologic applications. It was found that second-quartile storms occurred most frequently and fourth-quartile storms most infrequently. The time distribution characteristics resulted in this study have been presented in graphic forms such as time distribution curves with probability in cumulative percent of storm-time and precipitation, and selected histograms for first, second, third, and fourth quartile stroms.

  • PDF

A Study on the Experts' Perception for Effective Application of Low Impact Development (저영향개발 기법의 효율적인 적용을 위한 전문가 인식 유형에 관한 연구)

  • Lee, HyunJi;Lee, Junga;You, Soojin;Chon, Jinhyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.3
    • /
    • pp.65-78
    • /
    • 2016
  • LID(Low-Impact Development) has received a great deal of attention in the field of urban water management. The spread of LID technologies as a natural drainage system has led to a rise in consideration of the applicability of policy in Korea. In this respect, the purpose of this study is to analyze experts' perception about utilization, applicability of policy, and improvements of LID by using Q-methodology. The sample included 31 experts who were government employees, landscape architects, researchers, and professors related to LID. All participants completed a 28-statement Q-sort task. Data was analyzed by using QUANL computer software. As a result of this study, four distinct experts' perceptions about LID are identified: Policy Enforcement Oriented Type, Expert Understanding Oriented Type, Manual Oriented Type, and Effectiveness Oriented Type. This study suggested appropriate directions related to LID technologies, and it is helpful to apply the domestic type's LID and increase the efficiency of LID in Korea. However, this study has a limit in which the viewpoint of the researcher intervenes: a complementary searcher is needed to verify the validity by type in policy decision-making.

A Study on Process Optimization for CSOs Application of Horizontal Flow Filtration Technology (수평흐름식 여과기술의 CSOs 적용을 위한 공정 최적화 연구)

  • Kim, Jae-Hak;Yang, Jeong-Ha;Lee, Young-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.56-63
    • /
    • 2018
  • The management of Combined Sewer Overflows(CSOs) and Separated Sewer Overflows(SSOs) discharge directly to the effluent system in an untreated state, which occurs when the facility capacity is exceeded due to heavy rain, has become an important issue in recent years as the heavy rain becomes a regular phenomenon. Despite the continuous development of filtration technology, targeting densely populated urban areas, CSOs are rarely applied. Therefore, this study was carried out to optimize the process to apply CSOs in a pilot-scale horizontal flow filtration system with a rope-type synthetic fiber. The research was carried out in two steps: a preliminary study using artificial samples and a field study using sewage. In the preliminary study using an artificial sample, head loss of the filter media itself was analyzed to be approximately 1.1cm, and the head loss was increased by approximately 0.1cm as the linear velocity was increased by 10m/hr. In addition, the SS removal efficiency was stable at 81.4%, the filtration duration was maintained for more than 6 hours, and the average recovery rate of 98% was obtained by air backwashing only. In the on-site evaluation using sewage, the filtration duration was approximately 2 hours and the average removal efficiency of 83.9% was obtained when belt screen (over 450 mesh) was applied as a pre-treatment process to prevent the premature clogging of filter media. To apply the filtration process to CSOs and SSOs, it was concluded that the combination with the pre-treatment process was important to reinforce the hydraulic dimension for the stable maintain of operation period, rather than efficiency. Compared to the dry season, the quality of incoming sewage was lower in the rainy season, which was attributed to the characteristics of the drainage area with higher sanitary sewerage. In addition, the difference in removal efficiency according to the influent quality of the wet season and dry season was small.