• Title/Summary/Keyword: uplift pressure

Search Result 68, Processing Time 0.025 seconds

An Experimental Study on Suction Force of Plate Anchor Embedded in Bentonite (벤토나이트에 근입된 앵커의 흡입력에 관한 실험적 연구)

  • 이준대
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.97-102
    • /
    • 2001
  • Anchors are often used in construction of foundations such as transmission towers to resist uplifting forces. When plate anchors are embedded in soft clay, they may undergo a deformation under the pressure of sustained load. In soft saturated clays, the suction force can be a large par of the ultimate uplift capacity. This study is to present recent laboratory model test results conducted to evaluate the nature of variation of the suction force for plate anchors with shear strength and embedment ratio. The ratio of F$_{s}$Q$_{n}$ versus H/D in bentonite decreases with the increase of the embedment ratio.o.o.

  • PDF

A Case study and Analysis on the Up-Lift Pressure Treatment Evaluation of Underground Installations for their Efficient Adoption (사례분석을 통한 효율적 상향수압(Up-Lift Pressure) 처리공법 적용방안에 관한연구 - ◯◯ 상업지역 현장사례 중심으로 -)

  • Ko, Ok-Yeol;Kwon, Oh-Chul;Shim, Jae-Kwang;Park, Tae-Eun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.119-129
    • /
    • 2009
  • Building construction trends have been changed dramatically in terms of size and mass. With the need to maximize land usage, there has been an increase in the construction of high-rise buildings. This affects not only the entire construction duration and cost, but also subsequent construction activities, such as work to increase underground facilities and in reclamation land area construction. These types of site conditions require soft ground reinforcement and the proper uplift water pressure treatment. In general, two kinds of methods have been used for uplift water pressure treatment systems. However, there have been some problems arising as the result of a lack of research and analysis on underground construction techniques, and a reliance on experiments over actual survey and analysis of site conditions. This paper focused on the problems of conventional selection procedure, by analyzing drawings and proposing a kind of modeling for a reasonable procedure. The results were applied to OO project as a sample construction case to be verified in this research. The initial plan in the case project was the Rock Anchor System. However, as there were terrible miscalculations of basic site conditions that had an extraordinary influence on the underground water level, such as the site's proximity to the Han-river, it was necessary to change the plan to include apermanent drainage system. This achieved a direct construction cost reduction \ 406,702,000 and a maximum sayings of 4% of operational cost, based on the 50-year building Life Cycle Cost.

Experimental Evaluation of Shear Strength of Surface Soil Beneath Greenhouse Varying Compaction Rate (비닐하우스 기초 토양의 다짐률 변화에 따른 전단강도 특성)

  • Lim, Seongyoonc;Heo, Giseok;Kwak, Dongyoup
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.6
    • /
    • pp.17-26
    • /
    • 2021
  • Greenhouses have been damaged due to the uplift pressure from strong wind, for which rebar piles are often installed near the greenhouse to resist the pressure. For the effective design of rebar piles, it is necessary to access the shear strength of soil on which the greenhouse is constructed. This study experimentally evaluates the shear strength of the soil beneath the greenhouse. Four soil samples were collected from four agricultural sites, and prepared for testing with 75, 80, 85, and 90% compaction rates. One-dimensional unconfined compression test (UC), consolidated-undrained triaxial test (CU), and resonant column test (RC) were performed for the evaluation of shear strength and shear modulus. Generally, the higher shear strength and modulus were observed with the higher compaction rates. In particular, the UC shear strength increases with the increase of #200 sieve passing rate. Resulting from the CU test, the sample with the most of coarse soil had the highest friction angle, but the variation is small among samples. Resulting from the CU and RC tests, the ratio of maximum shear modulus with the major principle stress at failure was the higher at the finer soil. The ratio was two to three times greater than the ratio from the standard sand. This indicates that the shear strength is lower for the fine soil than the coarse soil at the same shear modulus. The results of this study will be a useful resource for the estimation of the pull-out strength of the rebar pile against the uplift pressure.

Pullout Characteristics of MC Anchor in Shale Layer (셰일지반에 설치된 MC앵커의 인발특성)

  • Lee, Bongjik;Kim, Josoon;Lee, Jongkyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.1
    • /
    • pp.53-61
    • /
    • 2012
  • In this study, the research on MC anchor has been developed as composite type has done. MC anchor exerts bearing pressure on pre-bored hole where the end fixing device is expanded. Therefore, the uplift capacity is to be increased and it has the characteristics that the anchor body is not eliminated from the ground even if the grouting is not carried out properly. Furthermore, it reduces the loss of tension and raises the construction availability by inserting the reinforced bar as well as the anchor cable, while it can improve the long-term stability because the nail is expected to play the role when the loss of the anchor cable is occurred in a long-term. However, because the resistance mechanism of the compound anchor such as MC anchor is different from friction anchor, the estimation method of the uplift capacity by the frictional force of the ground and the grout is not proper. Particularly, in domestic cases, the problem to overestimate or underestimate the uplift capacity is expected because the design method considering the soil characteristics about the compound anchor has not been developed. Therefore, in this study, in order to evaluate the characteristics of MC anchor and a kind of compound anchor, we measured the uplift, the tension and the creep by nine anchors tests in shale ground that the fluctuation of the strength is great. In addition, we analyzed the test result comparing to the result of the general friction anchor and evaluated the characteristics of MC anchor movement to gather the results. As a result of the test, we found the effect that the uplift capacity is increased in shale ground comparing to the general friction anchor.

Uplift Testing and Load-transfer Characteristics of Model Drilled Shafts in Compacted Weathered Granite Soils (화강풍화토 지반에 타설된 소형 현장 타설 말뚝의 인발시험 및 하중 전이 특성)

  • 임유진;서석현
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.105-117
    • /
    • 2002
  • In the design of foundations for the super-structures such as transmission towers and oil-platforms, the foundations must be considered as a medium to resist cyclic tensile forces. In this study, the uplift capacity of the drilled shaft used as the medium resisting to this pattern of forces is investigated by performing cyclic uplift test of a small model-drilled shaft constructed in compacted granite soil in a steel chamber. In this test, the behavioral difference between a pile loaded on the top of the pile and a pile loaded at the bottom of the pile was investigated intensively. The load transfer curves obtained from the test were investigated by changing the confining pressure in the chamber. The load tests also included creep test and cyclic test. It is found from the tests that uplift capacity of the shaft loaded at the bottom is greater than that of the shaft loaded on the top of the pile. It is found also from the creep test that the pile loaded at the bottom was more stable than the shaft loaded on the top. If a pile loaded at the bottom is pre-tensioned, the pile will be most effective to the creep displacement. It is found also from the cyclic tests that apparent secant modulus obtained in a cycle of the load increases with the number of cycles.

An analysis of the Behaviour of Uplift-Resisting Ground Anchors from Pull-out Tests (현장시험을 통한 부력앵커의 거동분석)

  • Lee, Cheolju;Jun, Sanghyun;Yoo, Namjae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.1
    • /
    • pp.33-40
    • /
    • 2007
  • Engineering behaviour of uplift-resisting ground anchors constructed in weathered rocks has been investigated by carrying out a series of full scale pull-out tests. The anchor was to resist uplift forces (buoyancy) associated with high groundwater table acting on the basement of a rail way station. The study has included the ultimate pull-out capacity of the anchors and shear stress transfer mechanism at the anchor-ground interface. The pull-out tests were conducted by changing bonded lengths of the anchor (2~7 m) and diameter of drilled borehole (108~165 mm) to investigate their effects on the behaviour of the anchor. The measured results showed that the ultimate capacity of the anchors was increased with an increase in the bonded length, diameter of drilled borehole as expected. The ultimate capacity of the anchors deduced from the pull-out tests ranged from 392 to 1,569 kN, depending on the above-mentioned factors. This corresponds to the interface shear strength of about 227~505 kPa. Interface shear stresses deduced from the pull-out test showed that the larger the pull-out force, the larger the mobilisation of the interface shear strength. The failure mode of the anchors heavily depended on the bonded lengths of the anchors. When the bonded length was short (2~3 m), a cone-type failure was observed, whereas when the bonded length increased (5~7 m), failure developed at the grout-ground interface.

  • PDF

Experimental Investigation of Wave Force on the Pavement behind Crown Wall of Rubble Mound Seawall (경사식 호안 상부구조물 배후 포장체에 작용하는 파력에 대한 실험적 연구)

  • Ko, Haeng Sik;Lee, Jooyeon;Jang, Se-Chul;Oh, Sang-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.34 no.1
    • /
    • pp.19-25
    • /
    • 2022
  • Physical experiments were conducted to establish an empirical formula that predicts the wave force on the upside of the pavement behind crown wall of rubble mound seawall due to wave overtopping as well as the uplift force on the downside of the pavement. The experiments were performed by different conditions of the parapet, water depth, relative freeboard, and thickness of the armour layer. Then, the wave force on the upside and downside of the pavement behind the crown wall was analyzed. The parameters that affect the wave overtopping force and the uplift force were identified and empirical formulae were suggested for evaluating the forces on the pavement.

Spatial extrapolation of pressure time series on low buildings using proper orthogonal decomposition

  • Chen, Yingzhao;Kopp, Gregory A.;Surry, David
    • Wind and Structures
    • /
    • v.7 no.6
    • /
    • pp.373-392
    • /
    • 2004
  • This paper presents a methodology for spatial extrapolation of wind-induced pressure time series from a corner bay to roof locations on a low building away from the corner through the application of proper orthogonal decomposition (POD). The approach is based on the concept that pressure time series in the far field can be approximated as a linear combination of a series of modes and principal coordinates, where the modes are extracted from the full roof pressure field of an aerodynamically similar building and the principal coordinates are calculated from data at the leading corner bay only. The reliability of the extrapolation for uplift time series in nine bays for a cornering wind direction was examined. It is shown that POD can extrapolate reasonably accurately to bays near the leading corner, given the first three modes, but the extrapolation degrades further from the corner bay as the spatial correlations decrease.

Calculation of Expected Sliding Distance of Wave Dissipating Caisson Breakwater (소파케이슨 방파제의 기대활동량 산정)

  • Kim, Dong-Hyawn
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.17 no.4
    • /
    • pp.213-220
    • /
    • 2005
  • An approach to calculate expected sliding distance of wave dissipating caisson breakwater is proposed. Time history of dynamic wave pressure for the calculation of sliding distance is made by extending conventional static wave pressure developed for the wave dissipating caisson breakwater. Construction of impact wave and standing wave was done by using duration time and maximum wave pressures of themselves. In the numerical analysis, the sliding distance for an attack of single wave and expected sliding distance for 50 years of wave dissipating breakwater by proposed method were compared with those by conventional method for uplift caisson breakwater. It was found that the sliding distance of wave dissipating breakwater by the proposed method is smaller than by conventional method.

Hydraulic Characteristics of Two Types of Pyramid-Shaped Artificial Reefs (피라미드형 패조류용 어초의 수리학적 특성)

  • Sohn, Byung-Kyu;Lee, Jeong-Woo;Yi, Byung-Ho;Yoon, Han-Sam
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.725-734
    • /
    • 2010
  • This study conducted hydraulic testing to assess the stability of two types of pyramid-shaped artificial reefs (ARs) constructed to promote the growth of shellfish and seaweed. Previous theoretical and hydraulic experimental studies have clearly demonstrated Froude similitude. The results of this study revealed that some dimensionless design parameters affected the stability of both types of artificial reefs under various wave and current field conditions (e.g., surf similarity parameters, water particle velocity, wave pressure). In the fixed bed condition, the dimensionless water particle velocity based on the surf similarity parameter was large (about 0.4), and in the moveable bed condition, the relative water depth based on the dimensionless wave pressure was low (about 0.11). In addition, horizontal wave pressure and uplift pressure varied by relative water depth, demonstrating the tendency for wave pressure to decrease linearly with increased relative depth. These findings indicate that the development of more stable design technology forartificial reefs should be based on long-term data and additional study of sliding due to wave action. The findings also highlight the importance of hydraulic experiments in solving problems that have emerged in the design and construction of artificial reefs.