• 제목/요약/키워드: unreinforced anchor

검색결과 11건 처리시간 0.019초

Dynamic shear strength of unreinforced and Hairpin-reinforced cast-in-place anchors using shaking table tests

  • Kim, Dong Hyun;Park, Yong Myung;Kang, Choong Hyun;Lee, Jong Han
    • Structural Engineering and Mechanics
    • /
    • 제58권1호
    • /
    • pp.39-58
    • /
    • 2016
  • Since the publication of ACI 318-02, the concrete capacity design (CCD) method has been used to determine the resistance of unreinforced concrete anchors. The regulation of steel-reinforced anchors was proposed in ACI 318-08. Until ACI 318-08, the shear resistance of concrete breakout for an unreinforced anchor during an earthquake was reduced to 75% of the static shear strength, but this reduction has been eliminated since ACI 318-11. In addition, the resistance of a hairpin-reinforced anchor was calculated using only the strength of the steel, and a regulation on the dynamic strength was not given for reinforced anchors. In this study, shaking table tests were performed to evaluate the dynamic shear strength of unreinforced and hairpin-reinforced cast-in-place (CIP) anchors during earthquakes. The anchors used in this study were 30 mm in diameter, with edge distances of 150 mm and embedment depths of 240 mm. The diameter of the hairpin steel was 10 mm. Shaking table tests were carried out on two specimens using the artificial earthquake, based on the United States Nuclear Regulatory Commission (US NRC)'s Regulatory Guide 1.60, and the Northridge earthquake. The experimental results were compared to the current ACI 318 and ETAG 001 design codes.

선설치앵커의 동적 전단하중에 대한 저항강도: 비보강 앵커 (Shear Resistance of CIP Anchors under Dynamic Loading: Unreinforced Anchor)

  • 박용명;강문기;김동현;이종한;강충현
    • 한국강구조학회 논문집
    • /
    • 제26권1호
    • /
    • pp.11-20
    • /
    • 2014
  • 2001년 이후 앵커의 설계는 Concrete Capacity Design(CCD) 방법이 적용되고 있는데, 국내 기준에서는 지진하중에 대한 콘크리트의 파열파괴강도를 정적 파괴강도의 75%로 제한하고 있다. 본 연구에서는 무근콘크리트에 매입된 선설치앵커의 동적 전단하중에 대한 콘크리트 파열파괴강도 평가하기 위한 실험을 수행하였다. 이를 위해 직경 20 mm의 앵커에 대해 정적 하중과 동적 편진하중에 대한 실험을 각각 3개의 시험체에 대해 수행하였으며, 앵커의 연단거리는 120 mm를 적용하였다. 동적 실험은 15 cycle의 편진하중을 1 Hz의 속도로 재하하였으며 반복하중단계의 크기를 키워가면서 최종 파괴 시까지 가력하였다. 실험으로부터 동적 전단하중에 의한 콘크리트 파열파괴강도는 정적하중에 의한 것과 거의 같은 파괴강도를 보였다.

비균열·무근콘크리트의 단일앵커 전단내력 평가 (Shear Strength of Single Anchors in Uncracked and Unreinforced Concrete)

  • 김성용;김규석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.171-181
    • /
    • 2003
  • 비균열 무근 콘크리트에 매입된 단일앵커는 연단거리와 콘크리트 강도에 따라 콘크리트 단부파괴, 콘크리트 부서짐파괴, 앵커파괴가 발생한다. 본 연구에서는 연단거리와 콘크리트 강도에 따라 콘크리트 단부파괴, 콘크리트 부서짐파괴, 앵커파괴 발생시 단일앵커의 전단내력평가를 목적으로 한다. 이를 위하여 ACI 318-02와 EOTA 기준의 근거인 CCD (Concrete Capacity Design) 방법과 기존의 앵커 설계기준인 ACI 349-90(45-Degree Cone Method)에 의한 예측값과 실험값을 서로 비교 평가하였다.

앵커간격 및 하중방향에 따른 앵커의 전단내력 (Shear Strength of Anchors under Load Applied Angle and a Group Anchors at an Edge)

  • 김성용
    • 한국방재학회 논문집
    • /
    • 제3권3호
    • /
    • pp.133-141
    • /
    • 2003
  • 본 연구는 비균열 무근콘크리트에 매입된 앵커의 앵커간격 및 하중방향에 따른 전단내력 평가를 목적으로 하고 있다. 이를 위하여 앵커의 전단내력 설계식을 비교 평가하였으며, 실험값과 기존의 설계식의 예측값을 비교 분석하였다. 그 결과, 앵커간격 및 하중방향에 따른 CCD 방법 및 EOTA 설계식은 합리적인 설계방법임을 알 수 있었다.

선설치앵커의 동적 전단하중에 대한 저항강도: 철근보강 앵커 (Shear Resistance of CIP Anchors under Dynamic Loading: Reinforced Anchor)

  • 박용명;강문기;노진경;주호중;강충현
    • 한국강구조학회 논문집
    • /
    • 제26권1호
    • /
    • pp.21-30
    • /
    • 2014
  • 본 연구에서는 헤어핀 보강 및 스트럽 보강 선설치앵커의 정적 및 동적 전단하중에 대한 저항강도 평가를 위한 실험을 수행하였다. 보강철근은 D6 이형철근을 사용하였으며 연단거리 120mm의 직경 20mm 앵커에 대해 정적 하중과 1Hz의 편진하중으로 각각 3개의 시험체에 대해 실험을 수행하였다. 헤어핀 보강 앵커는 헤어핀의 덮개가 강도에 직접 영향을 미치는 것으로 확인되었으며, 정적 대비 동적하중에서 강도의 저하는 없는 것으로 평가되었다. 스트럽 보강 앵커는 비보강 앵커에 비해 저항강도의 증가는 미소하였으며 동적하중에 의한 강도는 정적하중에 의한 강도와 거의 같은 값을 보였다.

스마트 건설기반의 강봉앵커 수동저항 효과를 고려한 단기 안전율 (The Short-term Safety Factor Considering Passive Resistance Effect of Bar Anchor Based on Smart Construction)

  • 이동혁;백두현
    • 한국지반환경공학회 논문집
    • /
    • 제25권4호
    • /
    • pp.29-35
    • /
    • 2024
  • 본 연구는 강봉앵커의 프리스트레스 도입 전 수동저항 효과를 확인하기 위한 해석적 연구이다. 영구앵커로 강봉을 사용하는 경우 두부 하중 재하 전에도 비탈면 내 변위 발생 시 강봉, 그라우트, 주변 지반사이 상호작용에 따른 수동저항효과로 변위가 억제된다. 이에 실제 강봉앵커가 적용된 현장을 대상으로 한계평형해석 및 유한요소해석을 이용하여 파괴면의 형상 및 안전율 변화를 검토하였다. 검토결과, 강봉앵커가 보강된 비탈면의 안전율은 유한요소해석결과 2.02이며, 한계평형해석결과 2.14에 비해 약 5.9% 작게 발생하였고 활동면의 위치도 더 깊게 발생하였다. 이는 보강 전 비탈면에 비해 안전율이 한계평형해석은 163%, 유한요소법은 153% 증가된 것이다. 또한, 최대발생 변위는 비탈면 내 하부 무보강구간에서 발생하였으며, 강봉앵커가 설치된 위치에서는 변위가 42~83% 감소되는 것으로 나타났다.

콘크리트 CIP 앵커시스템의 파괴 거동에 관한 연구 (Fracture behavior of Cast-in-place Headed Anchors to Concrete)

  • 박성균;김호섭;윤영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권3호
    • /
    • pp.141-152
    • /
    • 2001
  • This paper presents the evaluation of behavior and the prediction of tensile capacity of anchors that can cause a failure of the concrete on the basis of the design for anchorage. Tests of cast-in-place headed anchors, domestically manufactured and installed in uncracked and unreinforced concrete member are conducted to test the effected of embedment length and edge distance. The failure modes and the load-deformation responses of the anchors are discussed and then the concrete failure data are compared with capacities by the two present methods : the 45 degree cone method of ACI 349, 318 and the concrete capacity design (COD) method. Differences between the results by test and by two prediction methods are analyzed Finite Element Method (FEM).

  • PDF

지진모의실험에 의한 비균열 및 균열콘크리트에 매입된 비보강 선설치앵커의 전단 저항강도 평가 (Shear Resistance of Unreinforced Cast-In-Place Anchors in Uncracked and Cracked Concrete by Seismic Qualification Tests)

  • 박용명;김태형;김동현;조성훈;이종한
    • 한국강구조학회 논문집
    • /
    • 제27권3호
    • /
    • pp.347-357
    • /
    • 2015
  • 본 연구에서는 지진모의실험으로 비보강 선설치앵커의 전단에 대한 콘크리트 파열파괴강도를 평가하기 위한 실험 연구를 수행하였다. 이를 위해 앵커 직경 30mm, 연단거리 150mm, 매입깊이 240mm인 비균열 시험체와 전단하중에 수직 및 수평 방향 균열콘크리트 시험체들에 대해 각각 실험을 수행하였다. 지진모의실험 시 동적 가력은 CSA N287.2, ACI 355.2와 ETAG 001 기준을 참조하여 결정하였으며 이후 파괴 시까지 정적 재하를 실시하였다. 비균열 및 균열콘크리트 모두 지진모의실험에 의한 저항강도는 각각 정적 강도와 거의 동등한 수준이었다. 한편, 콘크리트 파괴단면의 깊이는 $8d_0$에 모두 미치지 못하였으며 이로부터 기존 강도식에 비해 유효지압길이를 고려하지 않는 ACI 318-11의 수정강도식이 콘크리트 파열파괴강도를 적절하게 평가하는 것으로 분석되었다.

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 전단 거동 분석 (Analysis on the Shear Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;하수경
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.105-117
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.