냉.난방 및 조명에너지를 통합 고려한 DSSC BIPV창호의 사무소건물 적용 효과 연구 (A Study on the Application Effect of DSSC BIPV Window System in Office Building Considering Cooling.Heating.Lighting Energy)

  • 심세라;윤종호;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.67-72
    • /
    • 2011
  • The aim of this study is to evaluate how much would the building energy consumption be saved by applying DSSC BIPV window which is possible to control the transmittance and express the color in the office building. For this, physical characteristics such as transmittance and reflectance, U-factor of DSSC areanalyzed and an annual energy consumption that is connected to dimming control is calculated when DSSC BIPV window is applied by alternate clear window system. As a result, It is possible to reduce the anannual energy consumption as much as4.1% by just change the clear double window system to DSSC BIPV double window system because the major factor to reduce energy consumption in the office that has much cooling load than other building is SHGC. When the thermal insulation properties of DSSC BIPV window with low-e coating and making triple window are improved, energy saving ratio is about 9%. Plus, energy saving ratio of 25~28% in lighting energy consumption is possible when the dimming control system with DSSC BIPV window is adopt.

건축물의 외피성능 및 실내온도에 따른 에너지 사용량에 관한 연구 (Study on Energy Consumption according to Building Envelope Performance and Indoor Temperature)

  • 유호천;강현구
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.101-108
    • /
    • 2011
  • This study aims to suggest an energy consumption improvement plan for university buildings through an analysis of energy consumption. Upon a simulation of subject building to interpret energy consumption, it was found that 154.07kWh/$m^2$ of energy is consumpted annually. Improvement of design elements can cut down the energy consumption to 135.61kWh/$m^2$ according to an energy reduction analysis related to envelope performance improvement. Additional improvement of lights and heat exchanger can curtail annual energy consumption to 108.32kWh/$m^2$. Also, an analysis of energy consumption while increasing indoor temperature gradually showed that the two factors are in proportion. $6^{\circ}C$ higher temperature requires over twice of the current energy. Based on this survey result, performance improvement due to building management and envelope elements which influence to building cooling and heating loads can curtail building energy consumption.

Envi-met 모델을 이용한 도심지역 대기오염측정망 주변의 바람장 분석 (An Analysis of Wind Field around the Air Quality Monitoring Station in the Urban Area by Using the Envi-met Model)

  • 김민경;이화운;도우곤;정우식
    • 한국환경과학회지
    • /
    • 제18권9호
    • /
    • pp.941-952
    • /
    • 2009
  • The urban microscale wind field around the air quality monitoring station was investigated in order to check how a building complex influences it. For this study as the high density areas Jwa-dong and Yeonsan-dong monitoring sites in Busan were chosen. As the direction of inflow which is perpendicular to the building of the monitoring station was expected to cause the considerable variation of the wind field, that direction was selected. The model Envi-met was used as the diagnostic numerical model for this study. It is suitable for this investigation because Envi-met has the microscale resolution. After simulating it, on the leeward side around a building complex the decrease of flow velocity and some of vortexes or circulation area were discovered. In addition, on the edge of the top at the building and at the back of the building the upward flow was developed. If the sampling hole of monitoring site were located in this upward flow, it would be under the influence of upward flow from the near street.

Comparison of the Frequency Bands for the Wireless Sensor Networks in the Building Environment

  • Lee, Eunae;Lee, Jeongmin;Kim, Dong Sik
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제8권2호
    • /
    • pp.23-30
    • /
    • 2016
  • In this paper, for the pratical building envoronments, the propagation properties of the electromagnetic waves of the sub-1GHz bands, including the 447MHz, 868MHz, and 715MHz, and the 2.4GHz band are experimentally observed in therms of the received signal strength indicator (RSSI) value. The compasion of the frequency bands can be utilized to efficiently construct the wireless sensor networks (WSN) for the building automation control. In order to measure the RSSI values in the building, an RSSI measurement system is first designed, in which the master part can transmit data packets and measure the corresponding RSSI values, and the slave part can respond the received data packets. Using the measurement system, the RSSI values are then experimentally measured at four types of building enviroments. From the experimental result analysis, we could notice that the sub-1GHz, especially the 447MHz band, showd a good communication performance for the building environment and could provide an efficient WSN construction when the data rate is relatively low.

발파해체현장에서 발생하는 순간분진의 입경분포 특성 (Characteristics of Particle Size Distributions Generated in the Vicinity of Building Blasting Demolition Sites)

  • 이경희;김효진;박찬규;고광백
    • 한국환경과학회지
    • /
    • 제18권1호
    • /
    • pp.41-47
    • /
    • 2009
  • In building demolition work, major dust-generating activities are blasting concrete and rock. The aim of this study was to find the characteristic of particle size of dusts which were generated during building demolition work using explosion. The DustMate of the Turnkey-Instruments Ltd. was used for particulate size-selective sampling of the four sites. TSP(Total Suspended Particle), PM10(Particle Matter $10{\mu}m$), PM2.5(Particle Matter $2.5{\mu}m$), and PM1.0(Particle Matter $1.0{\mu}m$) were measured during building demolition work using explosion. The large particulate (higher than the diameter $10{\mu}m$) showed to be higher than 50%. The particulate ranged from $10{\mu}m\;to\;2.5{\mu}m$ showed about 30-40%. PM2.5 was not scarcely detected in the samples collected for building demolition work using explosion. We conclude that the dust generated during building demolition work using explosion has not most respirable particulate.

지진시 저층건물 면진구조의 비선형 동적 거동 (Dynamic Stability Analysis of Base-Isolated Low-level Nonlinear Structure Under Earthquake Excitation)

  • 문병영;강경주;강범수;김계수
    • 대한기계학회논문집A
    • /
    • 제25권11호
    • /
    • pp.1743-1750
    • /
    • 2001
  • This paper presents an analysis of nonlinear response of the seismically isolated structure against earthquake excitation to evaluate isolation performances of a rubber bearing. In the analysis of the vibration of building, the building is modeled by lumped mass system where the restoring force is considered as linear, bilinear and trilinear. Fundamental equations of motion are derived for the base isolated structure, and hysteretic and nonlinear-elastic characteristics are considered for a numerical calculation. The excitation levels are magnified fur the recorded strong earthquake motions in order to examine dynamic stability of the structure. Seismic responses (of the building are compared fur the each restoring force type. As a result, it is shown that the effect of the motion by the nonlinear response of the building is comparatively not so large from a seismic design standpoint. The responses of the isolated structures reduce sufficiently and controled the motion of the building well in a practical range. By increasing the acceleration of the earthquake, the yielding of the farce was occurred in the concrete and steel frame, which shows the necessity of the exact nonlinear dynamic analysis.

건물에너지 저감을 위한 PCM/diatomite composites의 제조 및 특성 분석 (Preparation and characteristic analysis of PCM/diatomite composites for building energy saving)

  • 전지수;정수광;김수민
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.470-474
    • /
    • 2012
  • This paper deals with the thermal performances of PCM/diatomite composites for energy saving. The PCM/diatomite composites were prepared by incorporating PCMs in the pores of diatomite to increase form stability of PCMs. In experiment, we used the hexadecane, octadecane and paraffin as PCM and they have each 254.7 J/g, 247.6 J/g and 144.6 J/g of latent heat capacity, and those melting points are $20.84^{\circ}C$, $30.40^{\circ}C$ and $57.09^{\circ}C$, respectively. Thermal properties of PCM/diatomite composites were determined by using DSC. And PCM/diatomite composites were characterized by SEM and FTIR analysis. The results showed that the PCMs are well infiltrated into the structure of diatomite andt he latent heat capacity of PCM/diatomite composites was obtained by 40% of pure PCMs.

  • PDF

건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가 (A study on the Insulation Performance of the SuperWindow considering the Evaluation of Building Energy Rating)

  • 장철용;김치훈;안병립;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.1-6
    • /
    • 2010
  • Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend.In addition, the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1) The insulation performance of super window system is $1.44\;W/m^2^{\circ}C$ 2) Super Window compared to a normal window reduce heating energy requirements have been 5.3% 3) Compared to a normal window, Super window savings rate was 4.1% lower 4) Building energy efficiency rating was up to 1 rating from 2 rating.

Experimental study of wind-induced pressures on tall buildings of different shapes

  • Nagar, Suresh K;Raj, Ritu;Dev, Nirendra
    • Wind and Structures
    • /
    • 제31권5호
    • /
    • pp.431-443
    • /
    • 2020
  • The modern tall buildings are often constructed as an unconventional plan and as twin buildings. Wind load on the tall building is significantly influenced by the presence of another building in the near vicinity. So, it is imperative to study wind forces on an unconventional plan shaped tall building. Mean wind pressure coefficients of a square and 'H' plan shape tall buildings are investigated using wind tunnel experiments. The experiments were carried out for various wind directions from 00 to 900 at an interval of 300 and various locations of the identical interfering building. The experimental results are presented at the windward face from the viewpoint of effects on cladding design. To quantify the interference effects, interference factors (I.F) are calculated. Mean pressure coefficients of both models are compared for isolated and interference conditions. The results show that pressure reduces with an increase in wind angle till 600 wind direction. The interfering building at full blockage interference condition generates more suction than the other two conditions. The interference factor for both models is less than unity. H-plan building model is subjected to a higher pressure than the square model.

건축물 에너지 시뮬레이션 적용을 위한 목재 열전도율 데이터베이스 구축 (Wood Thermal Conductivity Database Construction for the Application of Building Energy Simulation)

  • 서정기;강유진;김수민
    • 한국가구학회지
    • /
    • 제27권2호
    • /
    • pp.122-127
    • /
    • 2016
  • The increasing interest in the environment and climate change around the globe, while the importance of building energy saving is increasing. The building energy simulation program is used for evaluating of energy performance of buildings. However, an input value of wood thermal conductivity in the programs is different from each other. Therefore, in this study, wood thermal conductivity was measured according to species. Through construction database by species of wood, the error of simulation program are able be decreased. In addition, if used as a structural and interior of buildings, the thermal conductivity and moisture of the wood is difficult to apply to the program because they were changed according to the occupant's lifestyle. In this paper, thermal conductivity and moisture content.of wood confirmed changes in the constant temperature and relative humidity ($25^{\circ}C$, 50% R.H.) condition.