• Title/Summary/Keyword: university building

Search Result 13,274, Processing Time 0.039 seconds

READINESS OF NIGERIAN BUILDING DESIGN FIRMS TO ADOPT BUILDING INFORMATION MODELLING (BIM) TECHNOLOGIES

  • Mu'awiya Abubakar;Yahaya Makarfi Ibrahim;Kabir Bala
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.640-647
    • /
    • 2013
  • Building Information Modelling (BIM) has become the new international benchmark for efficiency in design, construction and maintenance of buildings. It is the platform that brings about collaboration between project stakeholders and improvement of project outcomes. With all its potentials, not much of the impact of BIM technologies has been felt in the Nigerian construction industry. This research aimed at assessing the readiness of the Nigerian building design firms to adopt BIM technologies. The research was exploratory in nature. A field survey was conducted with the use of structured questionnaire, self administered to a sample of building design consultancy firms (architectural, structural, M&E, quantity surveying, and multi-disciplinary design firms) within Abuja and Kaduna. The questionnaire sought the perception of the responding firms on the factors affecting BIM adoption in the Nigerian construction industry, and their level of readiness to adopt BIM technologies in their practices based on the four categories of readiness-management, people, process and technology. 42.26% response rate was achieved and used for analysis. ANOVA and DUNCAN post-hoc tests were used to establish the differences between the responses of the groups of firms, while means and standard deviations were obtained to establish the important factors affecting BIM adoption in Nigeria. The survey revealed that all the groups of Nigerian design firms are appreciably ready for the adoption of BIM technologies in their practice, with slight variations in their respective levels of readiness. 'Lack of awareness of BIM technology among professionals' and clients and 'lack of knowledgeable and experienced partners' were identified as the most important barriers of BIM adoption in Nigeria; while the most significant drivers are 'availability of well trained professionals' and 'cooperation and commitment of professional bodies to the adoption'. Education and training of building design professionals and cooperation of all stakeholders in the design and construction supply chain were recommended as part of measures to ensure successful adoption of BIM in the Nigerian construction industry.

  • PDF

Preparation of Shape Stabilized PCM Using Porous Materials for Application to Buildings (건축적용을 위한 다공성 물질을 이용한 상안정 PCM 제조)

  • Jeong, Su-Gwang;Yu, Seulgi;Jang, Seulae;Park, Jin-Sung;Kim, Taehyun;Lee, Jeong-Hun;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.432-437
    • /
    • 2013
  • The increase of greenhouse gas emission and decrease of fossil fuel are being caused by the indiscreet consumption of energy by people. Recently, green policy has been globally implemented to reduce energy consumption. This paper studied the research to reduce the energy consumption in buildings, by using the heat storage properties of PCM. PCM has to prevent leakage from the liquid state. Therefore, we prepared form stable PCM, by using the vacuum impregnation method. Three kinds of organic PCMs were impregnated into the structure of porous material. The characteristics of the composites were determined by using SEM, DSC, FTIR and TGA. SEM morphology showed the micro structure of silica fume/PCM. Also, thermal properties were examined by DSC and TGA analyses; and the chemical bonding of the composite was determined by FTIR analysis.

A Study on Dwelling and Building (거주와 건립에 관한 한 고찰)

  • Khang, Hyuk
    • Journal of architectural history
    • /
    • v.11 no.4 s.32
    • /
    • pp.71-86
    • /
    • 2002
  • Since Modern period which is characterized by the governing of technology and capitalism, the production and aesthetics of building became a main issue of architectural discourse. Morever, Modern architecture tends to be a kind of media in which the visual image of building plays a far more important role than building itself. Institutionalized discipline of Architecture in modern system set aside the dwelling aspect of building and destructed close relationship between dwelling and building. This study analyzes the essential meaning of dwelling with a viewpoint of building and vise virsa in order to have a deep reflection on contemporary architecture and modern crisis of dwelling. For this purpose this study first reviewed linguistic and mythical narratives on the origin of dwelling and building. Secondly, reviewed the thought of Heidegger on dwelling and building and his thinking on authenticity of dwelling. Thirdly, reviewed drastic change of idea and reality of dwelling recent days, especially from settlement to nomad. Lastly reviewed E. Levinas' thinking on bodily dwelling or primordial mode of dwelling before poetic dwelling of Heidegger. With these review we can figure out following things on dwelling and building. Physical building or its visual image can not take the place of dwelling in itself. Dwelling and Building happens simultaneously and understood as an event in life world. Today's alienation of dwelling from building reduced our conception of architecture to a physical setting and mere technique. Building must be a ontological and cultural phenomenon beyond physical building. Nomad in this age of information and globalization may be a new mode of dwelling. But it can not exclude traditional way of dwelling on concrete space, because human being as a physical being can not abandon dwelling place that gives a primordial comfort with and within our body.

  • PDF

Assessment of damages on a RC building after a big fire

  • Ada, Mehmet;Sevim, Baris;Yuzer, Nabi;Ayvaz, Yusuf
    • Advances in concrete construction
    • /
    • v.6 no.2
    • /
    • pp.177-197
    • /
    • 2018
  • This paper presents a case study about the damages on the structural elements of a cast in place reinforced concrete (RC) building after a big fire which was able to be controlled after six hours. The fire broke off at the $2^{nd}$ basement floor of the building, which has five basements, one ground, and two normal floors. As a result of intensely stocked ignitable materials, it spread out to the all of the upstairs. In visual inspection, most of the typical fire damages were observed (such as spalling, net-like cracks, crumbled plasters, bared or visible reinforcement). Also, failures of the $2^{nd}$ basement columns were encountered. It has been concluded that the severity failures of the columns at the $2^{nd}$ basement caused utterly deformation of the building, which is responsible for the massive damages on the beam-column connections. All of the observed damages were categorized related to the types and presented separated regarding the floors. Besides to the visual inspection, the numerical analysis was run to verify the observed damaged on the building for columns, beams, and the connection regions. It is concluded from the study that several parameters such as duration of the fire, level of the temperature influence on the damages to the RC building. Also, it is highlighted by the study that if the damaged building is considered on the overall structural system, it is not able to satisfy the minimum service requirements neither gravity loads nor earthquake conditions.

Dynamic performance of a composite building structure under seismic ground motions

  • Tsai, Meng-Hao;Zhang, Junfei;Song, Yih-Ping;Lu, Jun-Kai
    • Earthquakes and Structures
    • /
    • v.15 no.2
    • /
    • pp.179-191
    • /
    • 2018
  • This study is aimed at investigating the dynamic performance of a composite building structure under seismic ground motions. The building structure is an official fire department building located in southern Taiwan. It is composed of a seven-story reinforced concrete (RC) and an eight-story steel reinforced concrete (SRC) frame. Both frames share a common basement and are separated by expansion joints from the first to the seventh floor. Recorded floor accelerations of the building structure under eight earthquakes occurring during the period from 2011 to 2013 were examined in this paper. It is found that both frames had similar floor acceleration amplifications in the longitudinal direction, while the SRC frame revealed larger response than the RC frame in the transverse direction. Almost invariant and similar fundamental periods under the eight earthquakes in both directions were obtained from their transfer functions. Furthermore, numerical time-history simulations were carried out for the building structure under the most intensive earthquake. It is realized that the seismic response of the composite building was dominated by the first translational mode in each horizontal direction. Higher modes did not significantly contribute to the structural response. The conventional Rayleigh damping model could be appropriately applied to the time-history simulations under bi-directional excitations. Approximate floor acceleration envelopes were obtained with a compound RC and SRC structural model by using the average damping ratios determined from the different structural arrays.

3D BIM-based Building Energy Efficiency Solution for Carbon Emission Reduction (탄소저감을 위한 3D BIM 기반 건물 에너지 효율화 방안)

  • Lee, Dong Hwan;Kwon, Kee Jung;Shin, Ju Ho;Park, Seunghee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1235-1242
    • /
    • 2013
  • This study deals with the BIM (Building Information Modeling)-based energy performance analysis implemented in EnergyPlus. The BIM model constructed at Revit is updated at Design Builder, adding HVAC models and converted compatibly with the EnergyPlus. We can obtain the input values about HVAC system and building environment such as HVAC system efficient, the number of air changes and energy consumption of equipment on applying GAs (Genetic algorithms). After modification about HVAC system, Optimization about HVAC system energy consumption can be analyzed. In order to maximize the building energy performance, a genetic algorithm (GA)-based optimization technique is applied to the modified HVAC models. Throughout the proposed building energy simulation, finally, the best optimized HVAC control schedule for the target building can be obtained in the form of "supply air temperature schedule". Throughout the supply air temperature schedule is applied to energy performance simulation, we obtained energy saving effect result on simulation.

Effect of General Ventilation Rate on Concentrations of Gaseous Pollutants Emitted from Enclosed Pig Building (밀폐형 돈사 작업장의 전체 환기율이 가스상 오염물질 노출 농도 변화에 미치는 영향)

  • Kim, Ki Youn;Seo, Sung Chul;Choi, Jeong-Hak
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • Objectives: The principal aim of this study was to compare the concentrations of gaseous pollutants emitted in enclosed pig buildings between different rates of general ventilation and determine the variations in the patterns of gaseous pollutants as affected by ventilation rate. Materials and Methods: The experiment was performed in the growing/finishing room($20.0m{\times}12.0m{\times}3.0m$) of a pig confinement building located on the experimental farm of Seoul National University. The conditions of the general ventilation rate for three treatments were 30%($4.12m^3s^{-1}$), 50%($6.87m^3s^{-1}$) and 70%($9.61m^3s^{-1}$). The data presented in the study were collected overa total of 45 days, 15 days for each of the three treatments from March to May 2011. A total of six air samplings were taken at 1.5m above the floor of the pig building. The environmental agents measured in the pig building were ammonia, hydrogen sulfide and odor concentration index for gaseous pollutants with temperature and hydrogen sulfide for thermal factors. Results: There were significant differences in the ammonia and odor concentration index in the pig building among the three general ventilation rate conditions(p<0.05), whereas hydrogen sulfide did not show a significant difference among three conditions of general ventilation rate(p>0.05). As the general ventilation rate applied to the pig building increases, it appears that all the indoor environmental agents measured in this study simultaneously decrease. Conclusions: The gaseous pollutants significantly affected by the general ventilation rate in pig building were ammonia and odor concentration index(p<0.05). However, it was found that hydrogen sulfide and thermal factors, temperature and relative humidity were not influenced significantly by variation in the general ventilation rate.

The Analysis of the Energy Saving Performances of Building Materials using Phase Change Materials (상변화물질을 적용한 건축자재의 에너지절약 가능성 분석)

  • An, Sang-Min;Hwang, Suck-Ho;Kim, Tae-Yeon;Leigh, Seung-Bok
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.162-167
    • /
    • 2011
  • Thermal storage plays an important role in building energy saving, which is greatly assisted by the incorporation of latent heat storage in building materials. A phase change material is a substance with a high heat of fusion which, melting and solidifying at a certain temperature, can be storing and releasing large amount of energy. Heat is stored or released when the material changes from solid to liquid. Integration of building materials incorporating PCMs into the building envelope can result in increased efficiency of the built environment. The aim of this research is to identify thermal performance of PCMs impregnated building materials which is applied to interior of building such as gypsum and red clay. In order to analyze thermal performance of phase change materials, test-cell experiments and simulation analysis were carried out. The results show that micro-encapsulated PCM has an effect to maintain a constant indoor temperature using latent heat through the test-cell experiments. PCM wallboard makes it possible to reduce the fluctuation of room temperature and heating and cooling load by using EnergyPlus simulation program. Phase change material can store solar energy directly in buildings. Increasing the heat capacity of a building is capable of improving human comfort by decreasing the frequency of indoor air temperature swings so that the interior air temperature is closer to the desired temperature for a long period of time.

  • PDF

Earthquake Direct Economic Loss Estimation of Building Structures in Gangnam-Gu District in Seoul Using HAZUS Framework (HAZUS틀을 사용한 서울시 강남구의 건축물 지진피해에 따른 직접적 경제손실 예측)

  • Jeong, Gi Hyun;Lee, Han Seon;Kwon, Oh-Sung;Hwang, Kyung Ran
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.391-400
    • /
    • 2016
  • For earthquake loss estimation of building structures in Gangnam-Gu district in Seoul, three scenario earthquakes were selected by comparison of the response spectra of these scenario earthquakes with the design spectrum in Korean Building Code (KBC 2009), and then direct losses of the building structures in the Gangnam-Gu district under each scenario earthquake are estimated. The following conclusions are drawn from the results of damage and loss in the second scenario earthquake, which has a magnitude = 6.5 and epicentral distance =15 km: (1) The ratio of building stocks undergoing the extensive and complete damage level is 40.0% of the total. (2) The amount of direct economic losses appears approximately 19 trillion won, which is 1.2% of the national GDP of Korea. (3) About 25% of high-rise (over 10-story) RC building wall structures, were inflicted with the damage exceeding moderate level, when compared to 60% of low-rise building structures. (4) From the economical view point, the main loss, approximately 50%, was caused by the damage in the high-rise RC wall building structures.

Analysis of Heat Transfer Characteristics by Material Based on Closed Conditions Using Acrylic Hemispheres (II): Comparison by Type of Building Structural Materials (아크릴 반구를 이용한 밀폐조건에 따른 재료별 열 이동특성 분석(II): 건축구조재 종류에 따른 비교)

  • YANG, Seung Min;KWON, Jun Hyuck;KIM, Phil Lip;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.710-721
    • /
    • 2020
  • This study used a building model made up of cement, brick, and wood to measure temperature and relative humidity for 3 days in a closed environment with a diameter of 900 mm, and performed a comparative analysis of the effect of types of building materials on the indoor temperature environment and heat transfer characteristics. The water installed inside the building model represented the person in the room and was used to assess how the environment effects the person. Wooden building model showed the lowest heat loss due to the higher thermal insulation properties than cement and brick buildings. The thermal comfort of each building model was calculated using temperature and relative humidity, and the wooden building model created a more pleasant environment than the cement and brick building models.