• Title/Summary/Keyword: university building

Search Result 13,274, Processing Time 0.055 seconds

An Analysis of the Impact of Building Wind by Field Observation in Haeundae LCT Area, South Korea: Typhoon Omais in 2021

  • Byeonggug Kang;Jongyeong Kim;Yongju Kwon;Joowon Choi;Youngsu Jang;Soonchul Kwon
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.380-389
    • /
    • 2022
  • In the Haeundae area of Busan, South Korea, damage has continued to occur recently from building wind from caused by dense skyscrapers. Five wind observation stations were installed near LCT residential towers in Haeundae to analyze the effect of building winds during typhoon Omais. The impact of building wind was analyzed through relative and absolute evaluations. At an intersection located southeast of LCT (L-2), the strongest wind speed was measured during the monitoring. The maximum average wind speed for one minute was observed to be 38.93 m/s, which is about three times stronger than at an ocean observation buoy (12.7 m/s) at the same time. It is expected that 3 to 4 times stronger wind can be induced under certain conditions compared to the surrounding areas due to the building wind effect. In a Beaufort wind scale analysis, the wind speed at an ocean observatory was mostly distributed at Beaufort number 4, and the maximum was 8. At L-2, more than 50% of the wind speed exceeded Beaufort number 4, and numbers up to 12 were observed. However, since actual measurement has a limitation in analyzing the entire range, cross-validation with computational fluid dynamics simulation data is required to understand the characteristics of building winds.

Application of Hydro-Cartographic Generalization on Buildings for 2-Dimensional Inundation Analysis (2차원 침수해석을 위한 수리학적 건물 일반화 기법의 적용)

  • PARK, In-Hyeok;JIN, Gi-Ho;JEON, Ka-Young;HA, Sung-Ryong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.2
    • /
    • pp.1-15
    • /
    • 2015
  • Urban flooding threatens human beings and facilities with chemical and physical hazards since the beginning of human civilization. Recent studies have emphasized the integration of data and models for effective urban flood inundation modeling. However, the model set-up process is tend to be time consuming and to require a high level of data processing skill. Furthermore, in spite of the use of high resolution grid data, inundation depth and velocity are varied with building treatment methods in 2-D inundation model, because undesirable grids are generated and resulted in the reliability decline of the simulation results. Thus, it requires building generalization process or enhancing building orthogonality to minimize the distortion of building before converting building footprint into grid data. This study aims to develop building generalization method for 2-dimensional inundation analysis to enhance the model reliability, and to investigate the effect of building generalization method on urban inundation in terms of geographical engineering and hydraulic engineering. As a result to improve the reliability of 2-dimensional inundation analysis, the building generalization method developed in this study should be adapted using Digital Building Model(DBM) before model implementation in urban area. The proposed building generalization sequence was aggregation-simplification, and the threshold of the each method should be determined by considering spatial characteristics, which should not exceed the summation of building gap average and standard deviation.

Reviewing Countermeasures of Building Equipment Part Due to the Expansion of the Remodeling Project (리모델링사업 확대에 따른 설비분야의 대응방안에 관한 연구)

  • Lee, Chul-Goo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.2
    • /
    • pp.1-6
    • /
    • 2014
  • As Korea's economy is entering a period of gradual growth, rate of growth on the construction market is becoming slow like that in developed countries. Remodeling construction market will be gradually expanded due to change in the social environment and diversification of individual demand. This study aims to promote the status of building equipment field with corresponding strategies based on the current situation that the importance of building equipment field is emphasized. Although it is desirable that building equipment construction companies lead remodeling construction, the building equipment part of general construction companies take the important role may be a advisable way, because the technology of building equipment construction companies is a little insufficient. Though building equipment field has become more important, the number of credits and professor of the field is still small than other fields of architectural engineering. More practical curriculums are necessary to meet the expectation of companies. Mechanical part of building equipment construction does not have independent law otherwise the other parts of building equipment construction. Establishing the independent law is urgent to promote the remodeling construction technology.

3D finite element analysis of the whole-building behavior of tall building in fire

  • Fu, Feng
    • Advances in Computational Design
    • /
    • v.1 no.4
    • /
    • pp.329-344
    • /
    • 2016
  • In this paper, a methodology to simulate the whole-building behaviour of the tall building under fire is developed by the author using a 3-D nonlinear finite element method. The mechanical and thermal material nonlinearities of the structural members, such as the structural steel members, concrete slabs and reinforcing bars were included in the model. In order to closely simulate the real condition under the conventional fire incident, in the simulation, the fire temperature was applied on level 9, 10 and 11. Then, a numerical investigation on the whole-building response of the building in fire was made. The temperature distribution of the floor slabs, steel beams and columns were predicted. In addition, the behaviours of the structural members under fire such as beam force, column force and deflections were also investigated.

Influence of Capacity Building and Attitude to Work of librarians in Edo State Public Libraries, Nigeria

  • Omigie, Christopher Agbeniaru;Bosah, Gabriel Ejiobi
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.10 no.1
    • /
    • pp.35-45
    • /
    • 2020
  • This study is on capacity building and attitude to work of librarians in Edo State public libraries, Nigeria. Investigation was on the capacity building programs in the Edo State public libraries, the levels of librarians' awareness and participation in the programs, methods of building the capacity programs, influence on the librarians' attitudes to work and factors militating against the programs. Descriptive survey design was adopted for the study and the entire population of 23 librarians were used. Results indicate that the capacity building programs in the library include computer literacy skills, online public access catalogue (OPAC), Internet collection management and general trends in librarianship. The methods used in building the capacity programs in the library include conferences, workshops/seminars, on-the-job and internally organized courses. Respondents indicated very low level of participation in the programs and a negative influence of the programs on their attitudes to work. Various problems were identified as militating against the capacity building programs and solutions were suggested.

Analysis of Energy Performance and PMV Improvement by Application of Passive Factor for Office Building Renewal (오피스건물 리뉴얼시 패시브 요소적용에 따른 에너지성능 및 PMV 개선에 관한 연구)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.55-64
    • /
    • 2014
  • This paper presents a case study to investigate the monthly calculation method of ISO 13790 applied for a office building. The energy performance analysis according to improvement of insulation and air permeability of windows in K office buildings is investigated by means of building energy efficiency rating tool ($ECO_2-OD$). The K building energy system is tested experimently by the measurement of PMV(predicted mean vote) for the control of indoor thermal environment and heat transmission coefficient of windows and interior walls respectively, before and after the example K office building is remodeled passively. Therefore, Internet based energy assessment program of energy efficiency rating of office building can be applied as a program for the annual energy requirement and for evaluation of energy savings from the experimental and simulation results.

Building Extraction from Lidar Data and Aerial Imagery using Domain Knowledge about Building Structures

  • Seo, Su-Young
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.3
    • /
    • pp.199-209
    • /
    • 2007
  • Traditionally, aerial images have been used as main sources for compiling topographic maps. In recent years, lidar data has been exploited as another type of mapping data. Regarding their performances, aerial imagery has the ability to delineate object boundaries but omits much of these boundaries during feature extraction. Lidar provides direct information about heights of object surfaces but have limitations with respect to boundary localization. Considering the characteristics of the sensors, this paper proposes an approach to extracting buildings from lidar and aerial imagery, which is based on the complementary characteristics of optical and range sensors. For detecting building regions, relationships among elevation contours are represented into directional graphs and searched for the contours corresponding to external boundaries of buildings. For generating building models, a wing model is proposed to assemble roof surface patches into a complete building model. Then, building models are projected and checked with features in aerial images. Experimental results show that the proposed approach provides an efficient and accurate way to extract building models.

Application Research on Mechanical Strength and Durability of Porous Basalt Concrete

  • Zhu, Yuelei;Li, Jingchun;Zhu, He;Jin, Long;Ren, Qifang;Ding, Yi;Li, Jinpeng;Sun, Qiqi;Wu, Zilong;Ma, Rui;Oh, Won-Chun
    • Korean Journal of Materials Research
    • /
    • v.32 no.3
    • /
    • pp.115-124
    • /
    • 2022
  • Porous basalt aggregate is commonly used in roadbed engineering, but its application in concrete has rarely been studied. This paper studies the application of porous basalt in concrete. Porous basalt aggregate is assessed for its effects on mechanical strength and durability of prepared C50 concrete; because it has a hole structure, porous basalt aggregate is known for its porosity, and porous basalt aggregates can be made full of water through changing the content of saturated basalt; after full-water condition is achieved in porous basalt aggregate mixture of C50 concrete, we discuss its mechanical properties and durability. The effects of C50 concrete prepared with basalt aggregate on the compressive strength, water absorption, and electric flux of concrete specimens of different ages were studied through experiments, and the effects of different replacement rates of saturated porous basalt aggregate on the properties of concrete were also studied. The results show that porous basalt aggregate can be prepared as C50 concrete. For early saturated porous basalt aggregate concrete, its compressive strength decreases with the increase of the replacement rate of saturated aggregate; this occurs up to concrete curing at 28 d, when the replacement rate of saturated basalt aggregate is greater than or equal to 40 %. The compressive strength of concrete increases with the increase of the replacement rate of saturated aggregate. The 28 d electric flux decreases with the increase of the replacement rate of saturated aggregate, indicating that saturated porous basalt aggregate can improve the chloride ion permeability resistance of concrete in later stages.

A Study on the Characteristics of the Stack Effect Occurs in Independent Core Type's Office Building (독립코어형 오피스 빌딩의 연돌효과 발생특성에 관한 연구)

  • Song, Cha-Won;Chung, Kwang-Seop;Jang, Hyun-Mun;Youn, Jeung-Eun;Lim, Tae-Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.4
    • /
    • pp.145-152
    • /
    • 2016
  • For a general office building having a center core, the distinction between the outer wall and the compartment should be clear, and it should be set at a stack effect pressure distribution acting on the respective compartment by a relative area ratio of the respective leak compartment. In the case of office buildings with an independent core for core there, some blocks of shares and exterior pressure distribution in buildings and office buildings typically have different characteristics. Therefore, if the stack effect reduction measures, designed on the basis of a general office building are applied to a stand-alone building, the core of the building should reflect the unique pressure distribution characteristics. This study, performed as part of the object corresponding to the flat plan of the building in the diversification trend, analyzed the stack effect that actually occurs in an office building having the properties intended for stand-core construction, and thus on the basis of and tested by the method of using a conventional stack effect reduction measures. Reviewed in the study, an independent cored office building that does not have the air flow path through the specific space with respect to the center core type office building has a feature, and the variation in characteristics of the pressure distribution inside the building according to this air flow path stack effect was reduced by a variety of measures that should be applied to determine the application.