• 제목/요약/키워드: unit water test

Search Result 394, Processing Time 0.028 seconds

Strength Characteristics of Light-Weight Cement mind Marine Clay with Foam (경량기포혼합 준설토의 강도특성)

  • 박건태;김주철;윤길림;이종규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.483-490
    • /
    • 2002
  • A massive amount of marine clay produced as dredging of coast and sea bed is often dumped in open sea and filled in pond. The treatment of marine clay demand a large area and make fatal environmental problems for echo system. This research work intend to manufacture a light-weight landfill materials which are produced by mixing the dredged marine clay with various amount cement and foam. An extensive Uniaxial and Triaxial compression test are carried out to investigate the strength characteristics of the light-weight cement mixed marine clay with foam under various test conditions. The results indicated that the required unit weight has been achieved with negligible change after 28days curing time in water. It is also recognized that the compressive strength of light-weight landfill materials linearly decrease with increasing initial water content, and the rate of strength decrease with increasing initial water content in water curing was smaller than that of air curing Futhermore, the rate of strength decreased with increasing initial water content, however, the rate become smaller as cement content increased.

  • PDF

Evaluation of the Oxygen Transfer Parameters (α and F) of a Coarse Bubble Aeration System by Off-gas Column Test (Off-gas Column Test를 이용한 하수처리장 심층포기시스템의 산소전달 매개변수(α와 F)의 산정)

  • Kim, Chul Woong;Lee, Se Ho;Shin, Dong Rok;Lee, Ji Yong;Park, Jae Han;Ahn, Yoon Hee;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1119-1122
    • /
    • 2006
  • Aeration by using diffusers usually requires approximately 50~90% of the total electricity needed to operate WWTP (WasteWater Treatment Plant)s. Accurate evaluation of the oxygen transfer efficiency for an aeration system, and recommendation of a better alternative may help saving WWTP operational costs. Appropriate techniques and methods to achieve this purpose have not been introduced in Korea. In this study, in-process analysis was performed for a coarse bubble aeration system by the off-gas method to evaluate its applicability in Korea. To accomplish this analysis, an off-gas test, unsteady-state clean water test and steady-state off-gas column test was conducted and comparisons to other aeration systems were made. The ${\alpha}$ and the F estimated from the results of the unsteady-state clean water test and the steady-state off-gas column test were 0.61 and 0.90 respectively in a coarse bubble aeration system. The comparison of P.E tube diffusers laid out single spiral roll and ceramic dome diffusers laid out full floor coverage showed that the oxygen transfer efficiency of the coarse bubble aeration system was less than or similar to other aeration systems. But, airflow rates per unit area were 4~5 times greater than other aeration systems. In regards to the oxygen transfer efficiency for airflow rates per unit area, a retrofit to higher efficiency diffusers was urgently needed. This study showed proved that off-gas methods can apply to evaluate diffuser performances to estimate operating factors and to compare other aeration systems in Korea.

Numerical analysis to determine fire suppression time for multiple water mist nozzles in a large fire test compartment

  • Ha, Gaghyeon;Shin, Weon Gyu;Lee, Jaiho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1157-1166
    • /
    • 2021
  • In this study, a numerical sensitivity analysis was performed to determine the fire suppression time for a large number of water mist nozzles in a large fire compartment. Fire simulations were performed using FDS (Fire dynamics simulator) 6.5.2 under the same condition as the test scenario 5 of the International Maritime Organization (IMO) 1165 test protocol. The sensitivities of input parameters including cell size, extinguishing coefficient (EC), droplets per second (DPS), and peak heat release rate (HRR) of fuel were investigated in terms of the normalized HRR and temperature distribution in the compartment. A new method of determining the fire suppression time using FDS simulation was developed, based on the concept of the cut-off time by cut-off value (COV) of the heat release rate per unit volume (HRRPUV) and the cooling time by the HRR cooling time criteria value (CTCV). In addition, a method was developed to determine the average EC value for the simulation input, using the cooling time and cut-off time.

Molar Ratio Control Scheme Based on Hideout Return Test for Ulchin Nuclear Power Plant Unit 3 (울진 3호기 잠복방출시험을 이용한 몰비 조절방안)

  • Kim, Y. H.;Y. N. Suh;Lee, S. S.;Kim, E. K.;Y. J. Pi
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.11a
    • /
    • pp.125-130
    • /
    • 1999
  • Corrosion of steam generator tubes is the major issue affecting selection of secondary water chemistry parameters. The objective of secondary side water chemistry control is to minimize corrosion damage and to thereby maximize the reliability and economic performance of the secondary system. To achieve this objective, the water chemistry has to be compatible with all parts of the system including steam generators.(Omitted)

  • PDF

Development of Weight Type Snowfall Gauge and Observation (중량식 강설량계 개발과 관측)

  • Lee, Bu-Yong
    • Journal of Environmental Science International
    • /
    • v.18 no.3
    • /
    • pp.255-261
    • /
    • 2009
  • We need water equivalent unit data of snowfall for the purpose of forecast and hydrology related research area. This study developed new method of automatic recording snowfall as weight unit. The instrument designed for measuring weight of snowfall by stain-gauge loadcell. Field test of instrument carried out at Daegwallyeong Obs. Station from 22 Jan. to 22 Feb. 2007. During observation period there is 15.3 cm snow depth and 16.0 mm of accumulated water equivalent depth at Daegwallyeong Obs. Station on 13 to 14 Feb. 2007. But the instrument of this study recorded 22.1 mm of water equivalent depth. It is not easy to explain difference between Daegwallyeong and this study. Because this study is only one case of comparison of snow measurement and there is very little amount of snow observation research. The density of snowfall calculated from 0.09 to $0.15g/cm^3$ from the observation data of 13 to 14 Feb. 2007. There is high relation between radar echo and snowfall amount measured by weight unit. It can supports forecast of snowfall and development of numerical model for forecast.

A Study on Improved Operation of Apartment Heating System in a Machine Room (공동주택 기계실 난방설비 운전 개선 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-42
    • /
    • 2017
  • This study proposes an idea for energy saving in apartment machine rooms. A conventional district heating system is equipped with constant-flow pumps and bypass valves to regulate pump differential pressure. Each family unit is equipped with a constant-flow on/off valve. This leads to excessive hot water circulation and a high return temperature. To reduce energy loss, this study assumes that each family unit is renovated with a heating valve which regulates the return temperature at $35^{\circ}C$. The hot water supply pump is also replaced with a pump with an inverter to vary flow rate. Expected energy savings is then estimated from field test data. According to the results, pump electricity consumption was reduced by 6,100 kWh for a family unit building over about half a year. The supply temperature can also be lowered by $5^{\circ}C$, which can contribute to a production of electricity of 10.3 kWh/ton of hot water.

A Soil Mechanical Study for a Practical Application to Forest Road Construction (임도설계(林道設計)에의 응용(應用)을 위한 흙의 토질(土質) 역학적(力學的) 특성(特性))

  • Kim, Ki Weon
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.2
    • /
    • pp.166-177
    • /
    • 1995
  • This study was carried out to discuss how soils in the area planned for a forest road construction can be mechanically tested and practically applied. For this, 16 soil test samples from 8 plots(2 samples per plot) were used. The major tests are focused on unit weight before and after cut, water content, liquid and plastic limits, sieve and hydrometer analysis etc. The total unit weight(${\rho}_t$) before and after cut are $1.69g/cm^3$ and $1.19g/cm^3$, respectively. Their water contents are 21.0% and 20.5%. The coefficient of uniformity U and coefficient of curvature C obtained from sieve and hydrometer analysis are 125 and 0.42, which mean generally not well graded. On the soil classification by USCS, SM(silty sand or silt-sand mixed soil)is a Key soil, but it seems to be not good for fill material. From the standard proctor test are resulted $1.40{\pm}0.065g/cm^3$ for the unit weight(${\rho}$) in the nature and $1.88{\pm}0.049g/cm^3$ for the optimum proctor unit weight(${\rho}pr$) each. With this to say, it is necessary more powerful compaction work at earth filling, with which this soil reachs enough the ${\rho}pr$, and more earth.

  • PDF

Characteristics of concrete intensity using high early strength AE water reducing agent (조강형 AE감수제를 사용한 콘크리트의 강도발현 특성)

  • Kim, Jung-Tai;Kim, Seung-Han;Jang, Seck-Soo;Jung, Yong-Wook;Yeo, In-Dong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.793-796
    • /
    • 2008
  • Recently early strength concrete has been required for economical assurance and the prevention of frost damage in winter through air reduction in construction of concrete structures. This study presented the optimum condition revealing compressive strength 5MPa which has the possibility of removal of form in 24 hours, and researched the changes of unit weight of cement types of high early strength AE water reducing agents, characteristic of compressive strength expression as cure temperature conditions and slump or airspace. Test results showed at $15^{\circ}C$ with compressive strength of 5MPa that premature removal of form was possible in case of using highly early strength PC water reducing agent with unit weight of cement 360 ; 22hours faster than 10, unit weight 360 ; 20hours faster than 7, unit weight 390 ; 18 hours faster than 4 comparing with OP water reducing agent. And at $5^{\circ}C$ in case of using highly early strength PC water reducing agent with unit weight of cement 330 ; 32hours faster than 10, unit weight 360 ; 30hours faster than 7, unit weight390 ; 27hours faster than 4 comparing with OP water reducing agent. Therefore as the temperature rises $10^{\circ}C$, compressive strength of 5MPa reaching hour shortens 10 hours.

  • PDF

Degradation and Ecotoxicity Reduction of Reactive Dye by Using Advanced Oxidation Process (고도산화공정을 이용한 반응성 염료의 제거 및 생태독성 저감)

  • Seo, Kyung Ae;Park, Jae Hong;Jung, Soo Jung;Lim, Byung Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.2
    • /
    • pp.204-211
    • /
    • 2013
  • In this study, the deriving optimum conditions for decolorization of Acid Orange II solution was carried using $TiO_2$ advanced oxidation process. After that, on base of the deriving results, the range of dye concentration was estimated. In addition, acute toxicity test was also carried to assess toxicity unit according to decolorization and TOC removal. In case of the blockage of light, 20 mg/L of dye solution, and 0.5 g $TiO_2$, the effect of decolorization at pH 3 was larger than at pH 6 and 10, so it was shown that decolorization is dependent on pH. The use of 5 g $TiO_2$ showed best performance of decolorization, but that of 3 g $TiO_2$ was chosen to optimum condition in considering of economical aspects. Four light sources, sun, fluorescent lamp, BLB lamp, and UV-B lamp, were used and decolorization was 99.4% and 100% at 50 mg/L, 98.6% and 99.7% at 100 mg/L for sun and UV-B lamp, respectively. In spite of the optimum condition of decolorization at pH 3, the evaluation of acute toxicity test showed highly toxic. In conclusion, although the optimum treatment of dye solution is performed, water ecology can be polluted in discharging it into water system. Therefore, it is needed to study of water ecological system with dye water treatment, and it takes all the circumstances into consideration.

Ecotoxicity Assessment of Industrial Effluent in Korea (산업폐수 방류수의 생태독성 평가)

  • Oh, Kyung Taek;Kim, Ji Won;Kim, Woo Kun;Lee, Soon Ae;Yun, Hong Gil;Lee, Sung Kyu
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.37-44
    • /
    • 2006
  • Ecotoxicity assessments of 90 selected effluents of 22 industry types from 2002 to 2004 in Korea were evaluated by a toxic battery of bioassay test using fish Oryzias latipes, invertebrate Daphnia magna, algae Selenastrum capricornutum and bacteria Vibrio fischeri with the physicochemical measurement items and permit concentrations on the present Water Quality Conservation Act in Korea. Total toxic unit (${\Sigma}TU$) of 8 industry types of 22 industry types by the toxic battery appeared in order of the value site as follows; Pigment Dye Manufacturing (${\Sigma}TU$ 217.1) > Textile and Dye (${\Sigma}TU$ 39.3) > Semiconductor Electronic Manufacturing (Small) (${\Sigma}TU$ 25.6) > Wastewater and Sewage Treatment Plants (${\Sigma}TU$ 25.4) > Coating (${\Sigma}TU$ 23.8) > Leather Skin Manufacturing (${\Sigma}TU$ 18.0) > Synthetic Resin Manufacturing (${\Sigma}TU$ 15.6) > Assemble Metal Manufacturing (${\Sigma}TU$ 10.7). Our results demonstrate that ecotoxicity assessment, by bioassay test, is effective and practical for industrial wastewater management for 90 selected effluents with the limitation of the physicochemical permit. Among 90 effluents, 9 samples failed physicochemical permit limitation and 81 passed it. In result of ecotoxicity assessment of 90 effluents by the toxic battery, 76 effluents exhibited ecotoxicity and the others did not. The physicochemical measurement items and permit concentrations on the present Water Quality Conservation Act in Korea were low related to the ecotoxicity value by the toxic battery and appeared limited for water quality management to water-ecosystem and environment-friendly management of water.