• Title/Summary/Keyword: unit volume

Search Result 1,258, Processing Time 0.025 seconds

Analytical Study for the Plan of Unit Household in National Housing Scale - Oriented on the cases of Korea housing corporation since 2005 ; Focused on analysing area (국민주택규모 단위세대 평면 분석 연구 - 2005년 이후 대한주택공사 사례를 면적분석 중심으로 -)

  • Lee, Jeong-Ho;Lee, Chan
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.1
    • /
    • pp.180-189
    • /
    • 2010
  • Since collective houses are started to be supplied, the housing market has been transformed from supplier to demander oriented, and various type with same area of unit households have been deigned and started to be distributed. It can be expected that such transfer phenomenon would be continuously sped-up, and unit household will be more subdivided and varied. Thus, we analysed and studied the planes with subject of unit households in national housing scale ($85m^2$) that is treated as supply standard and has biggest volume in construction by Korean housing corporation. The analysing method is investigating the area of each room within unit household, calculating their minimum, maximum, and average values, studying the efficiency of unit household plane according to the structure of each room by comparative analysis these values, and analysing changing matter by investigating any change of each room area. The analysing results of which are followings. At first, number of BAY on face is increasing. Second, allocation of each room has been vary. Third, area ratio among bedroom1, livingroom, diningroom/kitchen become similar. Fourth, the area of diningroom/kitchen become somewhat bigger. Fifth, the space for passage way is efficiently allocated. Sixth, service area is reduced, Seventh, stereotyped phenomenon Is appeared. Based on many studies so far, any improvements of unit householder in national housing scale are followings. First, in terms of forming style, unit householder in national housing scale is unfolded in various way though, the form of each room is not more than typical style. Second, it shows stereotyped phenomenon. Especially, bathroom 1, 2 show stereotyped feature in terms of their type and area across entire research years, also LDK allocation method is stereotyped, as well as stereotyped trend in bedroom 2, 3, allocation for 4 BAY type.

Prognostic factors and predictive models in hot gallbladder surgery: A prospective observational study in a high-volume center

  • Giovanni Domenico Tebala;Amanda Shabana;Mahul Patel;Benjamin Samra;Alan Chetwynd;Mickaela Nixon;Siddhee Pradhan;Bara'a Elhag;Gabriel Mok;Alexandra Mighiu;Diandra Antunes;Zoe Slack;Roberto Cirocchi;Giles Bond-Smith
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.28 no.2
    • /
    • pp.203-213
    • /
    • 2024
  • Backgrounds/Aims: The standard treatment for acute cholecystitis, biliary pancreatitis and intractable biliary colics ("hot gallbladder") is emergency laparoscopic cholecystectomy (LC). This paper aims to identify the prognostic factors and create statistical models to predict the outcomes of emergency LC for "hot gallbladder." Methods: A prospective observational cohort study was conducted on 466 patients having an emergency LC in 17 months. Primary endpoint was "suboptimal treatment," defined as the use of escape strategies due to the impossibility to complete the LC. Secondary endpoints were postoperative morbidity and length of postoperative stay. Results: About 10% of patients had a "suboptimal treatment" predicted by age and low albumin. Postop morbidity was 17.2%, predicted by age, admission day, and male sex. Postoperative length of stay was correlated to age, low albumin, and delayed surgery. Conclusions: Several predictive prognostic factors were found to be related to poor emergency LC outcomes. These can be useful in the decision-making process and to inform patients of risks and benefits of an emergency vs. delayed LC for hot gallbladder.

A Case Study on Development of Stormwater Retention and Infiltration Pond System (우수저류 및 침투연못 시스템개발 사례연구 - 우수 저류 및 침투 효과를 중심으로 -)

  • Lee, Jae Chul;Yoon, Yeo Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.4
    • /
    • pp.52-61
    • /
    • 2003
  • This study was carried out to analyze the effects of stormwater retention and infiltration pond on reduction of flood peak and volume in a experimentally developed ecological pond. The experimental site has 542$m^2$ watershed area, 1,310mm yearly-averaged rainfall. And the area of the retention pond is 60$m^2$, the maximum water depth is 0.5m, the maximum and average storage is 15$m^3$and 9.3$m^3$d. And the area of infiltration pond is 58$m^2$, and the water depth varies 0.2m~0.5m. The monitoring system consists of one rainfall gage, one Parshall flume and acoustic water level gage, two rectangular weirs and acoustic water level gage for discharge gaging, and one data recording unit. Data from ten storm events in total, three storm events in year 2000 and seven storm events in year 2001, were collected. From the data the evaporation rate was achieved with the water balance equation, and the result shows 5.0mm/day in average. The result from the analysis of the effects on reduction of flood peak and volume, is that 14% reduction of flood volume and 15% reduction of flood peak in retention pond and 49% reduction of flood volume in infiltration pond.

Analysis of Roadside Soil Characteristics and Tire Wear Particles(TWPs) According to Traffic Volume (교통량별 가로변 토양특성 및 타이어 마모 입자(TWPs) 분석)

  • Sun Yeong Lee;Jin Hee Ju;Yong Han Yoon
    • Journal of Environmental Science International
    • /
    • v.32 no.9
    • /
    • pp.627-634
    • /
    • 2023
  • Tire wear particles(TWPs), regarded as a microplastic, is generated in significant quantities each year and exist in various spaces and have a negative impact on the surrounding environment. Particularly, roadside environments fall within the direct influence of TWPs, necessitating proactive investigation for contamination management and response. Therefore, this study aimed to investigate the soil acidity and electrical conductivity(EC) and TWPs in the roadside soil of six sites based on traffic volume. The analysis revealed that the soil in all sites exhibited subacidity, and there were no significant differences in EC. Microscopic and FT-IR analysis revealed the presence of microscopic particles in soil samples that exhibited common visual characteristics of TWPs. In the road with the highest traffic volume, 48,300 TWPs were detected per unit area. Furthermore, a proportional relationship between traffic volume and TWPs particles was established. However, influences other than traffic volume on TWPs particle count within the soil were observed. Therefore, for the management of TWPs contaminated roadside soil, a proactive response is necessary in areas with high traffic volumes. However, in order to effectively address the factors contributing to the generation and dispersion of TWPs, further research is required with a multidimensional approach.

The Study on Compressive-Strength Property of the Aerated Concrete using Glass Fiber by Mixing Ratio (유리섬유 혼입 기포콘크리트의 배합변화에 따른 ,압축강도 특성에 관한 연구)

  • Her Jae-Won;Kim Hyo-Youl;Lim Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.93-98
    • /
    • 2005
  • The purpose of this study was to analyze the compression strength research by aerated concrete as mixing ratio This Study used foaming-agent and produced aerated concrete by pre-foam way that is used in construction site. An experiment changes unit cement amount, w/c and the glass fiber mixing rate and 'measured capacity change, unit capacity weight and compressive strength. The results obtained from experimental study are as following; Research to reduce unit capacity weight in condition more than unit cement amount 500kgf is considered should be gone side by side. The highest compressive strength result appeared in aerated concrete that cement amount 600kgf and w/c ratio $45\%$, $50\%$. compressive strength was increased maximum $34%$ when glass fiber $0.7\%$ addition cause by coherence enlargement to enlargement of cement paste and glass fiber addition per unit volume

  • PDF

A Study on the Analysis of Architectural Interior Space through Movement System focused on Hyangdan and Kwankajung (운동체계에 의한 건축공간 분석에 관한 연구 -향단과 관가정의 안채$\cdot$사랑채 실내공간분석 -)

  • Lee Kum-Jin;Choi Dong Hyeog
    • Journal of the Korean housing association
    • /
    • v.16 no.2
    • /
    • pp.55-65
    • /
    • 2005
  • 'Movement System' is made of the interaction of user and architectural spaces related to each other in order. 'Movement' meant in movement system is possible only in the status of user and architectural space together. Movement created and disappeared by the user is not subordinated to the existing architectural space but becomes the main element of formating movement system. It is required that movement conception applied to architecture should be derived from the essence of movement and this study presents the movement system. To explain the formating process of movement system, A. N. Whitehead's process philosophy theory is at the basis and transformed in architectural aspects. On basis of these theoretical backgrounds, the process of making movement system can be explained. There are unit movement, unit object, and elements for movement process as the basic requirements for movement system, each unit is apprehended by individual operation and the nexus is composed by associative operation of apprehended units. This nexus becomes the object of a new subject and forms multiple nexus. Relation of unit movement and unit object and nexus are apprehended as the continuation and extensive continuum is made. At that time, movement with multiple phases set inbetween systems and extended multiplied. Through above study, movement system is applied to Korean traditional houses.

Wire frame drive unit ofa SMA-based 3D shape display (SMA을 이용한 3차원 형상제시기의 와이어프레임 구동 유닛)

  • Chu Y.J.;Kim Y.M.;Song J.B.;Park S.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.439-440
    • /
    • 2006
  • This research proposes a novel method of shape display to present 3-dimensional objects. Shape displays allow us to feel the actual volume of the object, unlike conventional 2D visual displays of 3D objects. The proposed method employs a wire frame structure to present 3D objects. The wire frame is composed of small units driven by shape memory alloy(SMA) actuators. The drive unit is analogous to the agonist-antagonist system of animal musculoskeletal systems, where the SMA actuators serve as agonist and antagonist muscles. The force in the SMA actuator is controlled by electrical current. The drive unit is equipped with the locking mechanism so that it can sustain the external force exerted by the user as well as the own weight of the wire frame structure. By controlling the current into the SMA actuator and locking mechanism, we call control the angle of the drive unit. A chain of drive units enables presentation of 2 dimensional objects. 3 dimensional presentations are possible by collecting the chains of drive units.

  • PDF

A Comparative Study of Unit Hydrograph Models for Flood Runoff Estimation for the Streamflow Stations in Namgang-Dam Watershed (남강댐유역 내 주요 하천관측지점의 홍수유출량 추정을 위한 단위도 모형 비교연구)

  • Kim, Sung-Min;Kim, Sung-Jae;Kim, Sang-Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.3
    • /
    • pp.65-74
    • /
    • 2012
  • In this study, three different unit hydrograph methods (NRCS, Snyder and Clark) in the HEC-HMS were compared to find better fit with the observed data in the Namgang-Dam watershed. The Sancheong, Shinan, and Changchon in Namgang-Dam watershed were selected as the study watersheds. The input data for HEC-HMS were calculated land use, digital elevation map, stream, and watershed map provided by WAter Management Information System (WAMIS). Sixty six storms from 2004 to 2011 were selected for model calibration and validation. Three unit hydrograph methods were compared with the observed data in terms of simulated runoff volume, and peak runoff for the selected storms. The results showed that the coefficient of determination ($R^2$) for the peak runoff was 0.8295~0.9999 and root mean square error (RMSE) was 0.029~0.086 mm/day for calibration stages. In the model validation, $R^2$ for the peak runoff was 0.9061~0.9916 and RMSE was 0.030~0.088 mm/day which were more accurate than calibrated data. Analysis of variance showed that there was no significant difference among the three unit hydrograph methods.

Morphometric Study of Seminiferous Tubules in Pigeon, Pheasant, and Chicken (비둘기, 꿩 및 닭의 곱슬정세관에 관한 형태계측학적 연구)

  • 김인식;김지현;이영훈;정옥봉;양홍현
    • Korean Journal of Poultry Science
    • /
    • v.27 no.1
    • /
    • pp.63-71
    • /
    • 2000
  • The testis is an extremely heterogeneous organ, containing numerous compartments types. Morphometric studies were performed of 3 avian species (pigeon, pheasant and chicken) to determine volume density absolute volume, numerical density, total number of serminiferous tubule components, and sperm production, especially those related to the Sertoli cell, and to make comparisons among the species. Volume density of seminiferous tubule components per testis was determined by point counting method. Testis volume and sperm production were measured by routine techniques. Numerical density (the number of cells per unit volume of testis) of seminiferous tubule components per testis was determined by morphometry (Floderus method). The volume density of seminiferous tubules per testis was 91.58, 92.18 and 94.21% in pigeon, pheasant, and chicken, respectively. The volume density of spermatogonium, spermatocyte, spermatid, spermatozoon, and Sertoli cell did not produce significant changes in the three species. The absolute volume of spermatogonium, spermatocyte, spermatid, and Sertoli cell showed significant changes in the three species (p<0.05). The average volume of Sertoli cell ranged from 758.34(pheasant) to 1,212.9 ㎛$^3$(chicken) and was not significantoy different in the three species(p>0.05). The number of Sertoli cells per testis showed significant differences in the three species : 34.52 $\times$10(sup)6, 186.82$\times$10(sup)6, 810.62$\times$10(sup)6 in pigeon, pheasant, and chicken, respectively(p<0.05). The sperm production was significantly different in the three species : 3,018$\times$10(sup)6, 993.9$\times$10(sup)6, and 8.9$\times$10(sup)6 in chicken, pheasant, and pigeon, respectively(p<0.05). These results suggest that number of Sertoli cells may be more important than Sertoli cell size in explaining the difference in sperm production among the three species.

  • PDF

Mechanical Characteristics of Reinforced Soil(I) -Cement Reinforced Soil- (보강 혼합토의 역학적 특성(I) -시멘트 혼합토-)

  • Song, Chang-Seob;Lim, Seong-Yoon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.5 no.6
    • /
    • pp.9-13
    • /
    • 2002
  • This study has been performed to investigate the physical and mechanical characteristics of compaction, volume change and compressive strength for reinforced soil mixed with cement. And confirm the reinforcing effects with admixture such as cement. To this end, a series of compaction test and compression test was conducted for clayey soil(CL) and cement reinforced soil. In order to determine proper moisture content and mixing ratio, pilot test was carried out for soil and cement reinforced soil. And the mixing ratio of cement admixture was fixed 3%, 6%, 9% and 12% by the weight of dry soil. As the experimental results, the maximum dry unit weight(${\gamma}_{dmax}$) was increased with the mixing ratio and then shown the peak at 10% reinforced soil, but the optimum moisture content(OMC) and the volume change was decreased with the ratio increase. And the compressive strength volume change was decreased with mixing ratio increased.