• Title/Summary/Keyword: unit volume

Search Result 1,258, Processing Time 0.024 seconds

The Case Study on The Introduction and Practical Application of the Budget Management System -On the Performance Measurement of Standard Work Unit- (예산관리제도의 도입과 실제적 운용에 관한 사례연구 -표준적인 작업의 성과측정을 중심으로-)

  • 윤용운
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.2 no.2
    • /
    • pp.39-51
    • /
    • 1979
  • In introducing and applying the budget management system, the question of how to establish management structure(skelton) representing budget management responsible unit is significantly related to the degree of accuracy and analysis on the performance measurement of standard work unit. We have the following rational process of establishing performance measurement of budget management System ; 1) Standardization of work method 2) Establishment of management structure 3) Institution of budget management system. Especially, this system is based on a premise of efficiency of objectives management, it is assumed that performance measurement in the standard work unit must be enforced according to the basis and categories of performance evaluation based on the evaluating work unit. Therefore, most of all, the following three detail questions(subjects) are to be determined in order to rationalize these above principles to a maximum possible extent of performance measurement system. First, we established respective performance standard unit with respect to such detailed work unit, performance standard unit of which were accurately applicable directly from using the budget ana objectives account data and their supplementary data of the work measurement techniques. Second, by using the above mentioned question, over all evaluation and suggestion are made based on the study of the recording for each work unit development, budget management and production nit (volume of production) Third, the measurement of performance of budget management system is based on the principle of standard work unit, compared with the standard basis and actual work unit by period and activities unit and calculated percentage effectiveness according to the above procedure. and so evaluated the efficiency of performance measurement on the budget management system.

  • PDF

The Iron Status of Very Low Birth Weight Infants Receiving Multiple Erythrocyte Transfusions during Hospitalization in the Neonatal Intensive Care Unit

  • Park, Sook-Hyun;Kim, Heng-Mi
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.18 no.2
    • /
    • pp.100-107
    • /
    • 2015
  • Purpose: We investigated the iron status of very low birth weight infants receiving multiple erythrocyte transfusions during hospitalization in the neonatal intensive care unit (NICU). Methods: We enrolled 46 very low birth weight infants who were admitted to the Kyungpook National University Hospital between January 2012 and December 2013. Serum ferritin was measured on their first day of life and weekly thereafter. We collected individual data of the frequency and volume of erythrocyte transfusion and the amount of iron intake. Results: A total of 38 (82.6%) of very low birth weight infants received a mean volume of $99.3{\pm}93.5mL$ of erythrocyte transfusions in NICU. The minimum and maximum serum ferritin levels during hospitalization were $146.2{\pm}114.9ng/mL$ and $456.7{\pm}361.9ng/mL$, respectively. The total volume of erythrocyte transfusion was not correlated to maximum serum ferritin concentrations after controlling for the amount of iron intake (r=0.012, p=0.945). Non-transfused infants took significantly higher iron intake compared to infants receiving ${\geq}100mL/kg$ erythrocyte transfusion (p<0.001). Minimum and maximum serum ferritin levels of non-transfused infants were higher than those of infants receiving <100 mL/kg erythrocyte transfusions (p=0.026 and p=0.022, respectively). Infants with morbidity including bronchopulmonary dysplasia or retinopathy of prematurity received a significantly higher volume of erythrocyte transfusions compared to infants without morbidity (p<0.001). Conclusion: Very low birth weight infants undergoing multiply erythrocyte transfusions had excessive iron stores and non-transfused infants also might had a risk of iron overload during hospitalization in the NICU.

A Study on the Laboratory Scale Ultrasound Treatment System for Methyl tert-Butyl Ether Polluted Groundwater (Methyl tert-Butyl Ether 오염 지하수 처리를 위한 실험실 규모 초음파 분해 시스템 연구)

  • Kim, Heeseok;Yang, Inho;Cho, Hyeonjo;Her, Nam Guk;Jeong, Sangjo
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.747-753
    • /
    • 2010
  • A series of experiments with a laboratory scale ultrasound treatment system for MTBE polluted groundwater was performed to increase the efficiency of MTBE degradation in groundwater. This study evaluated several factors to increase the efficiency of MTBE treatment for artificial and natural groundwater. The treated volume of groundwater, ultrasound frequency and power, and pollutant concentrations have been changed to evaluate its effects on the degradation efficiency of MTBE in batch and continuous flow reactor. For the specific experimental conditions on this paper, MTBE degradations are more efficient at 580 kHz than those at 1 MHz. The efficiency of MTBE degradation is proportional to the intensity of ultrasound power per unit volume of MTBE polluted groundwater. The concentration of ions in groundwater does not much affect the efficiency of MTBE degradation. The $1^{st}$ order degradation constant of MTBE for different power per unit volume at 580 kHz shows linear relationship at same concentration. The $1^{st}$ order degradation constant for 0.1 mM MTBE solution is higher than that for 1 mM MTBE solution. These experimental results could be helpful to seek optimal conditions for relatively large volume of polluted groundwater treatment.

Forecasting the Korea's Port Container Volumes With SARIMA Model (SARIMA 모형을 이용한 우리나라 항만 컨테이너 물동량 예측)

  • Min, Kyung-Chang;Ha, Hun-Koo
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.6
    • /
    • pp.600-614
    • /
    • 2014
  • This paper develops a model to forecast container volumes of all Korean seaports using a Seasonal ARIMA (Autoregressive Integrated Moving Average) technique with the quarterly data from the year of 1994 to 2010. In order to verify forecasting accuracy of the SARIMA model, this paper compares the predicted volumes resulted from the SARIMA model with the actual volumes. Also, the forecasted volumes of the SARIMA model is compared to those of an ARIMA model to demonstrate the superiority as a forecasting model. The results showed the SARIMA Model has a high level of forecasting accuracy and is superior to the ARIMA model in terms of estimation accuracy. Most of the previous research regarding the container-volume forecasting of seaports have been focussed on long-term forecasting with mainly monthly and yearly volume data. Therefore, this paper suggests a new methodology that forecasts shot-term demand with quarterly container volumes and demonstrates the superiority of the SARIMA model as a forecasting methodology.

Thermal Optimization of a Straight Fin Heat Sink with Bypass Flow (바이패스가 있는 히트 싱크의 열성능 최적화)

  • Kim, Jin-Wook;Kim, Sang-Hoon;Kim, Joong-Nyon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.179-184
    • /
    • 2010
  • This experimental study investigated the effect of tip clearance and bypass flow on the cooling performance of a straight fin heat sink. Both the horizontal and vertical directions of the bypass flow were studied by using a mass flow controller and test sections. The thermal resistance of a heat sink was obtained to elucidate the response of the cooling performance to tip clearance and bypass flow. The thermal resistance of a straight fin heat sink gradually increases with increasing tip clearance. A flow guide unit was employed to reduce the bypass flow. An optimal distance from the leading edge of the heat sink to the flow guide unit was found for the fixed volume flow rate. The contribution of the flow guide unit to the thermal performance of a heat sink increases with increasing volume flow rate.

Clinical Outcomes of Intracranial Nonvestibular Schwannomas Treated with Linac-Based Stereotactic Radiosurgery and Radiotherapy

  • Puataweepong, Putipun;Dhanachai, Mantana;Hansasuta, Ake;Saetia, Kriangsak;Dangprasert, Somjai;Sitathanee, Chomporn;Yongvithisatid, Pornpan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3271-3276
    • /
    • 2016
  • Background: Intracranial nonvestibular schwannomas arising from various cranial nerves excluding CN VIII are uncommon. Recently, stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (SRT) have been widely reported as effective treatment modalities for nonvestibular schwannomas. The purpose of this study was to study the long term clinical outcome for nonvestibular schwannomas treated with both X-Knife and CyberKnife (CK) radiosurgery at one institution. Materials and Methods: From 2004 to 2013, fifty-two nonvestibular schwannoma patients were included in this study, 33 patients (63%) were treated with CK, and 19 (37%) were treated with X-Knife. The majority of the tumors were jugular foramen schwannomas (38%) and trigeminal schwannomas (27%). HSRT was given for 45 patients (86%), whereas CSRT was for 6 (12%) and SRS for 1 (2%). Results: The median pretreatment volume was $9.4cm^3$ (range, $0.57-52cm^3$). With the median follow up time of 36 months (range, 3-135), the 3 and 5 year progression free survival was 94 % and 88%, respectively. Tumor size was decreased in 13 (25%), stable in 29 (56%), and increased in 10 (19%). Among the latter, 3 (30%) required additional treatment because of neurologic deterioration. No patient was found to develop any new cranial nerve deficit after SRS/SRT. Conclusions: These data confirmed that SRS/SRT provide high tumor control rates with low complications. Large volume tumors and cystic expansion after radiation should be carefully followed up with neurological examination and MRI, because it may frequently cause neurological deterioration requiring further surgery.

Increased ERCP volume improves cholangiogram interpretation: a new performance measure for ERCP training?

  • Shyam Vedantam;Sunil Amin;Ben Maher;Saqib Ahmad;Shanil Kadir;Saad Khalid Niaz;Mark Wright;Nadeem Tehami
    • Clinical Endoscopy
    • /
    • v.55 no.3
    • /
    • pp.426-433
    • /
    • 2022
  • Background/Aims: Cholangiogram interpretation is not used as a key performance indicator (KPI) of endoscopic retrograde cholangiopancreatography (ERCP) training, and national societies recommend different minimum numbers per annum to maintain competence. This study aimed to determine the relationship between correct ERCP cholangiogram interpretation and experience. Methods: One hundred fifty ERCPists were surveyed to appropriately interpret ERCP cholangiographic findings. There were three groups of 50 participants each: "Trainees," "Consultants group 1" (performed >75 ERCPs per year), and "Consultants group 2" (performed >100 ERCPs per year). Results: Trainees was inferior to Consultants groups 1 and 2 in identifying all findings except choledocholithiasis outside the intrahepatic duct on the initial or completion/occlusion cholangiogram. Consultants group 1 was inferior to Consultants group 2 in identifying Strasberg type A bile leaks (odds ratio [OR], 0.86; 95% confidence interval [CI], 0.77-0.96), Strasberg type B (OR, 0.84; 95% CI, 0.74-0.95), and Bismuth type 2 hilar strictures (OR, 0.81; 95% CI, 0.69-0.95). Conclusions: This investigation supports the notion that cholangiogram interpretation improves with increased annual ERCP case volumes. Thus, a higher annual volume of procedures performed may improve the ability to correctly interpret particularly difficult findings. Cholangiogram interpretation, in addition to bile duct cannulation, could be considered as another KPI of ERCP training.

The effect of implant drilling speed on the composition of particle collected during site preparation

  • Jeong, Chang-Hee;Kim, Do-Young;Shin, Seung-Yun;Hong, Jong-Rak;Kye, Seung-Beom;Yang, Seung-Min
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.sup2
    • /
    • pp.253-259
    • /
    • 2009
  • Purpose: This study was aimed to evaluate the effect of implant drilling speed on the composition of particle size of collected bone debris. Methods: $Br{\aa}nemark$ $System^{(R)}$ drills were used to collect bone debris from 10 drilling holes (1 unit) at 1,500 rpm (Group A) and 800 rpm (Group B) in bovine mandible. After separating particles by size into > 500 ${\mu}m$, between 250 ${\mu}m$ and 500 ${\mu}m$, and < 250 ${\mu}m$ fractions, particle wet volume, dry volume, and weight were measured and the proportion of 3 fractions of bone debris to total wet volume, dry volume and weight was calculated as wet volume % , dry volume % and weight %. Results: No significant differences were found between Group A and B in wet volume, dry volume, and weight. However, of >500 ${\mu}m$ fractions, Group B had significantly higher wet volume %(P = 0.0059) and dry volume %(P = 0.0272) than in Group A. Conclusions: The drilling speed influenced the composition of particle size in collected drilling bone debris. The drilling in 800 rpm produced the more percentage of large particles than in 1,500 rpm. However, the drilling speed didn't effect on total volume of and weight of bone debris.

A Proposal for Improving the Measurement and Management of Unit Water Content in In-Situ Concrete (현장 타설 콘크리트의 단위수량 측정 및 관리 개선 방안 제시)

  • Yun, Ja-yeon;Jang, Hyo-Jun;Lee, Taegyu;Choi, Hyeonggil
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.3
    • /
    • pp.319-329
    • /
    • 2024
  • This study examined domestic and international regulations concerning concrete unit weight, along with an evaluation of unit weight in concrete poured on construction sites. Fluctuations in unit weight were observed to correlate with concrete quality issues such as material separation, bleeding, and latency. A word cloud analysis, centered on the concept of concrete quality, further highlighted the significant influence of unit weight. Comparative analysis between Korea and Japan revealed few substantial differences in unit weight management and measurement techniques. However, calculation of concrete unit weight at delivery, using the unit volume mass method, indicated considerable variability among random on-site samples. Notably, the unit weight often exceeded the recommended standard. These findings emphasize the necessity for strict adherence to unit weight standards by all stakeholders involved in concrete production and construction, including ready-mix concrete (REMICON) producers, construction firms, and inspectors. To ensure consistent quality of cast concrete on-site, the establishment of a more comprehensive and practical system is recommended, incorporating measures such as on-site inspections.

A Design of Teaching Unit to Foster Secondary Pre-service Teachers' Mathematising Ability: Inquiry into n-volume of n-simplex (예비중등교사의 수학화 능력을 신장하기 위한 교수단원의 설계: n-단체(simplex)의 n-부피 탐구)

  • Kim Jin-Hwan;Park Kyo-Sik
    • School Mathematics
    • /
    • v.8 no.1
    • /
    • pp.27-43
    • /
    • 2006
  • The objective of this paper is to design teaching units to foster secondary pre-service teachers' mathematising abilities. In these teaching units we focus on generalizing area of a 2-dimensional triangle and volume of a 3-dimensional tetrahedron to n-volume of n-simplex In this process of generalizing, principle of the permanence of equivalent forms and Cavalieri's principle are applied. To find n-volume of n-simplex, we define n-orthogonal triangular prism, and inquire into n-volume of it. And we find n-volume of n-simplex by using vectors and determinants. Through these teaching units, secondary pre-service teachers can understand and inquire into n-simplex which is generalized from a triangle and a tetrahedron, and n-volume of n-simplex which is generalized from area of a triangle and volume of a tetrahedron. They can also promote natural connection between school mathematics and academic mathematics.

  • PDF