• Title/Summary/Keyword: unit time

Search Result 5,683, Processing Time 0.029 seconds

Sequential Catalytic Combustion System (순차식 촉매연소 시스템)

  • 유상필;정남조;이승재;류인수;강성규;송광섭
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2004.05a
    • /
    • pp.197-200
    • /
    • 2004
  • Compared to conventional flame combustion, catalytic combustion had the advantage of oxidation of V.O.C. gas which was high voluminous, low caloric mixture flow. However, the temperature of mixture gas should be over the one of catalytic reaction start and the control of reaction on the catalytic surface tends to be vulnerable. To overcome these obstacles, composition of both catalytic combustor and heat exchanger was devised and named the sequential catalytic combustion system. In this system, only trigger unit needed preheating process for transient starting time. Once trigger unit was ignited, the next unit w3s supplied heat to ignite from that and same process was performed to the last one sequentially. When it come to steady state, whole mixture gas was oxidated at each unit simultaneously and preheating for trigger unit was not needed any more. System of 100 kcalh/hr capacity was devised and operated successfully.

  • PDF

Electric-optical Characteristics of Backlight Unit with LED Light Source in Low Temperature Condition

  • Han, Jeong-Min;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.2
    • /
    • pp.93-96
    • /
    • 2007
  • LCD (liquid crystal display) industry is needed to goods of high reliability and is interested in products without harmful material. In this experiment, we made the LED backlight unit for Automotive-navigation. And for making this backlight unit we used to eight side emitting type white LEDs with 1 W high power of the lumileds company. We could know that this backlight unit releases to 6500 nit in 14 W power consumption and start up voltage time is under the 15ms in the ambient temperature $-20\;^{\circ}C$.

An Experimental Study on the Rule Based Fault Detection and Diagnosis System for a Constant Air Volume Air Handling Unit (룰 베이스를 이용한 정풍량 공조기 고장 검출 및 진단 시스템의 실험적 연구)

  • Han, Do-Young;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.872-880
    • /
    • 2004
  • The fault detection and diagnosis technology may be applied in order to decrease the energy consumption and the maintenance cost of the air-conditioning system. In this study, an air handling unit fault test apparatus was built and fault diagnosis algorithms were applied to diagnose various faults of an air handling unit. Test results showed the good diagnosis for applied faults. Therefore, these algorithms may be effectively used to develope the real time fault detection and diagnosis system for the air handling unit.

FRONT-END TELEMETRY DATA ACQUISITION UNIT FOR KSLV-I UPPER STAGE

  • Jung Hae-Seung;Kim Joonyun;Lee Jae-Deuk
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.337-340
    • /
    • 2004
  • Upper stage telemetry system of KSLV- I (Korea Space Launch Vehicle I) is composed of MDU (Master Data Unit), RDU (Remote Data Unit), SRU (Shock Recorder Unit) and Transmitter. RDU is the front-end telemetry data acquisition unit which gathers analog/discrete signals from various sensors and other units, and transmits the processed data to MDU via MIL-STD-I553B data bus. In order to acquire useful data from analog signal, signal conditioning circuits, such as anti-aliasing or amplifying, should be implemented. For this purpose, SCM (Signal Conditioning Module) had been developed. This paper describes hardware structure of SCM and analog signal conditioning circuits for various sensors. Also, sampling time scheme for different sampling rates were designed and tested.

  • PDF

Advanced JTAG-based On-Chip Debugging Unit Design for SoC

  • Yun Yeonsang;Kim Seungyoul;Kim Youngdae;You Younggap
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.61-65
    • /
    • 2004
  • An on-chip debugging unit is proposed aiming performance enhancement of JTAG-based SoC systems. The proposed unit comprises a JTAG module and a core breaker. The IEEE 1149.1 standard has been modified and applied to the new JTAG module. The proposed unit eliminates redundant clock cycles included in the TAP command execution stage reducing overall debugging time. TAP execution commands are repeatedly issued to perform debugging of complicated SoC systems. Simulation on the proposed unit shows some $14\%$ performance enhancement and $50\%$ gate count reduction compared to the conventional ones.

  • PDF

A Design of 24-bit Floating Point MAC Unit for Transformation of 3D Graphics (3차원 그래픽의 트랜스포메이션을 위한 24-bit 부동 소수점 MAC 연산기의 설계)

  • Lee, Jungwoo;Kim, Woojin;Kim, Kichul
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • This paper proposes a 24-bit floating point multiply and accumulate(MAC) unit that can be used in geometry transformation process in 3D graphics. The MAC unit is composed of floating point multiplier and floating point accumulator. When separate multiplier and accumulator are used, matrix calculation, used in the transformation process, can't use continuous accumulation values. In the proposed MAC unit the accumulator can get continuous input from the multiplier and the calculation time is reduced. The MAC unit uses about 4,300 gates and can be operated at 150 MHz frequency.

  • PDF

A Usability Evaluation Method Based on the Lostness of Unit Action for Coding Education Software (코딩 교육용 소프트웨어에 대한 단위 행동 손실률 기반의 사용성 평가 방법)

  • Park, Hee Sung;Park, Kwang-Hyun
    • The Journal of Korea Robotics Society
    • /
    • v.10 no.2
    • /
    • pp.96-103
    • /
    • 2015
  • In this paper, we first point out the limitation of the existing methods in usability evaluation, and propose a new method to find tasks and users that can cause problems in the use of software applications. To deal with object-based applications, we define unit actions and divide a given task into the sequence of unit actions. Then, we propose a new measure to calculate the degree of lostness for the unit actions. In several experiments, we show the proposed method can represent the usability well while the previous method has a problem in object-based applications. We also find that the user's evaluation is more related to the proposed method than the previous method based on execution time through correlation analysis.

An Experimental Study on the Evaluation of Unit-Water Content in Mortar Using High Frequency Moisture Sensor (고주파 수분 센서를 이용한 모르타르의 단위수량 평가에 관한 실험적 연구)

  • Cho, Yang-Je;Yu, Seung-Hwan;Yang, Hyun-Min;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.17-18
    • /
    • 2021
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data.

  • PDF

An Fundamental Study on the Measurement of Cement Mortar Unit-Water Content Using High Frequency Moisture Sensor (고주파 수분 센서를 이용한 시멘트 모르타르의 단위수량 측정에 관한 기초적 연구)

  • Cho, Yang-Je;Kim, Min-Seo;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.6-7
    • /
    • 2020
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data.

  • PDF

Halo, Reversed Halo, or Both? Atypical Computed Tomography Manifestations of Coronavirus Disease (COVID-19) Pneumonia: The "Double Halo Sign"

  • Antonio Poerio;Matilde Sartoni;Giammichele Lazzari;Michele Valli;Miria Morsiani;Maurizio Zompatori
    • Korean Journal of Radiology
    • /
    • v.21 no.10
    • /
    • pp.1161-1164
    • /
    • 2020
  • The epidemic of 2019 novel coronavirus, later named as coronavirus disease (COVID-19), began in Wuhan, China in December 2019 and has spread rapidly worldwide. Early diagnosis is crucial for the management of the patients with COVID-19, but the gold standard diagnostic test for this infection, the reverse transcriptase polymerase chain reaction, has a low sensitivity and an increased turnaround time. In this scenario, chest computed tomography (CT) could play a key role for an early diagnosis of COVID-19 pneumonia. Here, we have reported a confirmed case of COVID-19 with an atypical CT presentation showing a "double halo sign," which we believe represents the pathological spectrum of this viral pneumonia.