• Title/Summary/Keyword: unit time

검색결과 5,683건 처리시간 0.033초

분산형 사고파형저장 시스템에 대한 연구 (The Study of Distributed Disturbance Recording System)

  • 박종찬;이세인
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.30-35
    • /
    • 2008
  • In this paper, the application of power Quality monitoring based on Sampled Value(SV) which is introduced in the IEC61850 International Standard for substation communication are discussed. Firstly, while Merging Unit(MU) is designed as a process level device transmitting sensor data, the practical problems such as time delay compensation and optical fiber communication are encountered. Secondly, the Sampled Value message which is proper to a power quality monitoring system is presented. Because the power quality monitoring system requests less time-critical service compared to protection and control applications, the Sampled Value service message structure is introduced to improve efficiency. Lastly, the power quality monitoring server having various power quality analysis functions is suggested to verify the performance of Merging Unit With the diverse experiments, it is proved that the process bus distributed solution is flexible and economic for the power quality monitoring.

Tabu 탐색법을 이용한 화력 발전기의 기동정지계획 (Thermal Unit Commitment using Tabu Search)

  • 천희주;김형수;황기현;문경준;박준호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권2호
    • /
    • pp.70-77
    • /
    • 2000
  • This paper proposes a method of solving a unit commitment problem using tabu search (TS) which is heuristic algorithm. Ts is a local search method that starts from any initial solution and attempts to determine a better solution using memory structures. In this paper, to reduce the computation time for finding the optimal solution, changing tabu list size as intensification strategy and path relinking method as diversification strategy are proposed. To show the usefulness of the proposed method, we simulated for 10 units system and 110 units system. Numerical results show improvements in the generation costs and the computation time compared with priority list, genetic algorithm(GA), and hybrid GA.

  • PDF

무상수리 정책에서 응급수리 적용의 비용분석 모델 (Cost Analysis Model for Minimal Repair in Free-Replacement Policy)

  • 김재중;김원중
    • 산업경영시스템학회지
    • /
    • 제20권43호
    • /
    • pp.241-247
    • /
    • 1997
  • This paper is concerned with cost analysis model in free-replacement policy. The free-replacement policy with minimal repair is considered as follows; in a manufacturer's view point operating unit is periodically replaced, if a failure occurs between minimal repair and periodic maintenance time, unit is remained in a failure condition. Also unit undergoes minimal repair at failures in minimal-repair interval. Then total expected cost is calculated according to the parameter of failure distribution in a view of consumer's. The expected costs are included repair cost and usage cost: operating, fixed, minimal repair and loss cost. Numerical example is shown in which failure time of item has weibull distribution.

  • PDF

IEC61850 프로세서 버스 기반 분산형 전력품질감시 (IEC61850 Process Bus Based Distributed Power Quality Monitoring)

  • 박종찬;김병진
    • 전기학회논문지P
    • /
    • 제56권1호
    • /
    • pp.13-18
    • /
    • 2007
  • In this paper, authors deal with an application of power quality monitoring using the Sampled Value which is described in the IEC61850 International Standard for substation communication. Firstly, while Merging Unit is designed as a process level device transmitting sensor data, the practical problems such as time delay compensation and optical fiber communication are issued. Secondly, the Sampled Value message which is proper to a power quality monitoring system is presented. Because the power quality monitoring system requests non time critical service comparing to protection and control applications, the Sampled Value service message structure is introduced to improve efficiency. At last, the power quality monitoring server having various power quality analysis functions is suggested to verify the performance of Merging Unit. With the diverse experiments, it is proved that the process bus distributed solution is flexible and economic for the power quality monitoring.

Gated recurrent unit (GRU) 신경망을 이용한 적혈구 침강속도 예측 (Forecasting of erythrocyte sedimentation rate using gated recurrent unit (GRU) neural network)

  • 이재진;홍현지;송재민;염은섭
    • 한국가시화정보학회지
    • /
    • 제19권1호
    • /
    • pp.57-61
    • /
    • 2021
  • In order to determine erythrocyte sedimentation rate (ESR) indicating acute phase inflammation, a Westergren method has been widely used because it is cheap and easy to be implemented. However, the Westergren method requires quite a long time for 1 hour. In this study, a gated recurrent unit (GRU) neural network was used to reduce measurement time of ESR evaluation. The sedimentation sequences of the erythrocytes were acquired by the camera and data processed through image processing were used as an input data into the neural network models. The performance of a proposed models was evaluated based on mean absolute error. The results show that GRU model provides best accurate prediction than others within 30 minutes.

수.화력 발전기의 일간 기동정지계획 (Optimal Daily Hydrothermal Unit Commitment)

  • 유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.97-100
    • /
    • 1987
  • An improved hydrothermal unit commitment algorithm is proposed for the purpose of optimal operation of electric power system. Especially, Dynamic Programming Method which is main scheme of the algorithm is modified to assure the feasible solution all the time. The effectiveness of the algorithm has been demonstrated by applying to a sample system.

  • PDF

연구용 원자로의 정지봉 장치 성능에 미치는 인자 분석과 성능 시험 (Performance test and factor analysis on the performance of shutoff units with the research reactor)

  • 김경련;김석범;고재명;문균영;박종호
    • 한국유체기계학회 논문집
    • /
    • 제10권2호
    • /
    • pp.41-45
    • /
    • 2007
  • The shutoff unit was designed to provide rapid insertion of neutron absorbing material into the reactor core to shutdown the reactor quickly and also to withdraw the absorber slowly to avoid a log-rate trip. Four shutoff units were installed on the HANARO reactor but the half-core test facility was equipped with one shutoff unit. The reactor trip or shutdown is accomplished by four shutoff units by insertion of the shutoff rods. The shutoff rod(SOR) is actuated by a directly linked hydraulic cylinder on the reactor chimney, which is pressurized by a hydraulic pump. The rod is released to drop by gravity, when triplicate solenoid valves are de-energized to vent the cylinder. The hydraulic pump, pipe and air supply system are provided to be similar with the HANARO reactor. The shutoff rod drops for 647mm stroke within 1.13 seconds to shut down the reactor and it is slowly inserted to the full down position, 700mm, with a damping. We have conducted the drop test of the shutoff rod in order to show the performance and the structural integrity of operating system of the shutoff unit. The present paper deals with the 647mm drop time and the withdrawal time according to variation of the pool water temperature, the water level and the core flow.

강우 시간분포를 고려한 설계홍수량산정 (Estimation of Design Flood Considering Time Distribution of Rainfall)

  • 박재현;안상진;함창학;최민호
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1191-1195
    • /
    • 2006
  • Now days, heavy storm occur to be continue. It is hard to use before frequency based on flood discharge for decision that design water pocket structure. We need to estimation of frequency based on flood discharge on the important basin likely city or basin that damage caused by flood recurrence. In this paper flood discharge calculated by Clark watershed method and SCS synthetic unit hydrograph method about upside during each minute of among time distribution method of rainfall, Huff method choosing Bocheong Stream basin that is representative basin of International Hydrologic Project (IHP) about time distribution of rainfall that exert big effect at flood discharge estimate to research target basin because of and the result is as following. Relation between probability flood discharge that is calculated through frequency analysis about flood discharge data and rainfall - runoff that is calculated through outward flow model was assumed about $48.1{\sim}95.9%$ in the case of $55.8{\sim}104.0%$, SCS synthetic unit hydrograph method in case of Clark watershed method, and Clark watershed method has big value overly in case of than SCS synthetic unit hydrograph method in case of basin that see, but branch of except appeared little more similarly with frequency flood discharge that calculate using survey data. In the case of Critical duration, could know that change is big area of basin is decrescent. When decide time distribution type of rainfall, apply upside during most Huff 1-ST because heavy rain phenomenon of upsides appears by the most things during result 1-ST about observation recording of target area about Huff method to be method to use most in business, but maximum value of peak flood discharge appeared on Huff 3-RD too in the case of upside, SCS synthetic unit hydrograph method during Huff 3-RD incidental of this research and case of Clark watershed method. That is, in the case of Huff method, latitude is decide that it is decision method of reasonable design floods that calculate applying during all $1-ST{\sim}4-TH$.

  • PDF

낸드 플래시 메모리 상에서 효율적인 MR-트리 동작을 위한 지연 연산 기법 (Delay Operation Techniques for Efficient MR-Tree on Nand Flash Memory)

  • 이현승;송하윤;김경창
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제14권8호
    • /
    • pp.758-762
    • /
    • 2008
  • 플래시 메모리 중 저장장치로 사용되는 낸드 플래시 메모리는 유비쿼터스 및 모바일 환경에 적합한 특성으로 다양한 분야의 저장장치로 이용되고 있으며 효율적인 활용을 위한 많은 연구가 진행되고 있다. 모바일 환경에서 이용할 수 있는 멀티미디어 데이타베이스 시스템을 위한 인덱스로써 공간 데이타 액세스가 가능한 R-트리의 검색 성능을 향상시킨 MR-트리는 메인 메모리 데이터베이스 시스템에서 캐쉬 미스를 줄이고 중간 노드의 이용률을 높임으로써 연산 성능을 높일 수 있는 특성을 가진다. 본 논문에서는 검색 성능이 좋은 MR-트리를 활용하여 낸드 플래시 메모리 기반에서 효율적인 동작을 위한 지연 연산 기법을 제안하였다. MR-트리의 노드 크기를 낸드 플래시 메모리의 쓰기 연산 단위에 맞추고 인덱스 수정 연산 시 노드 크기만큼 지연 연산하여 쓰기 연산으로 인한 플래시 메모리에서의 추가적인 비용을 줄이고 연산 횟수를 줄여 인덱스 성능을 향상 시켰다.

Real-time PCR과 Colony forming unit법을 이용한 타액 내 2종의 구강미생물 총량분석 (Analysis of total oral microorganisms in saliva using real-time PCR and colony forming unit)

  • 유수민;정성국;유현준;장종화
    • 한국치위생학회지
    • /
    • 제17권1호
    • /
    • pp.13-25
    • /
    • 2017
  • Objectives: The purpose of this study was to compare colony forming unit (CFU) method and multiplex real-time polymerase chain reaction (MRT-PCR) method for accurate quantitative analysis of bacteria. Methods: We compared the CFU method and the MRT-PCR method, which are still used in Korea, for Prevotella intermedius (P. intermedius), a periodontal disease pathogen selected by MRT-PCR, and Streptococcus mutans (S. mutans), a dental caries causative organism. The subjects of this study were 30 patients who visited the C dental hospital. Results: Total microorganisms in MRT-PCR method were significantly higher in both types of bacteria (p<0.05), since DNA of dead bacteria was also analyzed. This was because the periodontal dise(-) anaerobes, and even dead bacteria contain large amounts of toxic substances called LPS in the extracellular membrane, and fimbriae and pili, which are motility structures, still remain as a strong toxic substance in periodontal tissue. Conclusions: Therefore, in terms of the total amount of bacteria found, the MRT-PCR method will be a useful technique for searching all the bacteria in the oral cavity including live bacteria, as well as sterilization.