• Title/Summary/Keyword: unit time

Search Result 5,653, Processing Time 0.032 seconds

Effects of Various Packaging Systems on the Quality Characteristic of Goat Meat

  • Morales-delaNuez, A.;Moreno-Indias, I.;Falcon, A.;Arguello, A.;Sanchez-Macias, D.;Capote, J.;Castro, N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.3
    • /
    • pp.428-432
    • /
    • 2009
  • 40 goat kid ribcages were held for 7 days in storage conditions ($4^{\circ}C$) and used to determine the effects of three different packaging methods (atmospheric air, vacuum and modified atmosphere package (MAP) 10:70:20 mixture of $N_2:O_2:CO_2$) on meat quality of the chops. L* was affected by the packaging method being lighter than MAP chops. The coordinate a* significantly increased during storage time. For MAP-packed chops and those kept in atmospheric air, b* increased markedly during storage time whereas it remained unaffected throughout storage when in vacuum packages. Final pH values ranged from 5.6 to 5.8 and no effects were found for either storage time or packaging method. WHC means were lowest for the three packaging methods on day 7 of storage and highest on day 1. Storage time increased water loss in vacuum treatments. Trained panel colour acceptability was lower at 3, 5 and 7 days than on day 1 of storage for atmospheric air treatment and vacuum packaging, while for the MAP treatment average values on days 5 and 7 were lower than those observed on days 1 or 3. Trained panel odour was lower for atmospheric air and vacuum packages at 3, 5, and 7 days storage than at 1 day, while no differences were found in trained panel odour acceptability for MAP packages. With reference to consumers, the MAP proposed in the present study is the chosen method for storing goat meat, rather than vacuum or atmospheric air packaging.

Load Balancing Based on Transform Unit Partition Information for High Efficiency Video Coding Deblocking Filter

  • Ryu, Hochan;Park, Seanae;Ryu, Eun-Kyung;Sim, Donggyu
    • ETRI Journal
    • /
    • v.39 no.3
    • /
    • pp.301-309
    • /
    • 2017
  • In this paper, we propose a parallelization method for a High Efficiency Video Coding (HEVC) deblocking filter with transform unit (TU) split information. HEVC employs a deblocking filter to boost perceptual quality and coding efficiency. The deblocking filter was designed for data-level parallelism. In this paper, we demonstrate a method of distributing equal workloads to all cores or threads by anticipating the deblocking filter complexity based on the coding unit depth and TU split information. We determined that the average time saving of our proposed deblocking filter parallelization method has a speed-up factor that is 2% better than that of the uniformly distributed parallel deblocking filter, and 6% better than that of coding tree unit row distribution parallelism. In addition, we determined that the speed-up factor of our proposed deblocking filter parallelization method, in terms of percentage run-time, is up to 3.1 compared to the run-time of the HEVC test model 12.0 deblocking filter with a sequential implementation.

The Network Implementation on Data Communication of TCMS in case of multiple configuration of EMU(Electric Multiple Unit) (전동차의 중련연결시 TCMS장치의 데이터 통신에 관한 네트워크 구현)

  • Seo Sang-Jun;Han Jeong-Soo;Choi Jong-Muk
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.744-749
    • /
    • 2005
  • The train configuration is based on one unit like basic 4 cars to multiple unit operation. Each unit has unique node such as train formation number. Some equipments(TC, CC) of TCMS are connected to the master TC through the LonWorks network. When the train is consist of multiple unit, TCMS has to implement quick network for data communication overall train. But a variable time delay is generated when it is performed communication with point to point type using train formation number. In this paper we propose new method to know the node information of adjacent unit. that is to add digital input signals notifying cab direction at any cabin. Also, we provide the optimized screen design that all collected information via network is displayed by each unit.

  • PDF

A Study on the Design of the Automatic Cutting Mechanism of the Perforation Pipes in an Automobile Muffler (차량 소음기용 다공파이프 자동절단 메커니즘 설계에 관한 연구)

  • Kim, Yong-Seok;Jeong, Chan-Se;Yang, Soon-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.3
    • /
    • pp.350-356
    • /
    • 2011
  • In this paper, we proposed the automatic cutting mechanism of the perforation pipes in an automobile muffler. This cutting mechanism makes continuous work possible, because it performs the batch work via the sequential operation of loading, feeding, cutting, and discharging. The proposed cutting mechanism consists of the frame unit, escape unit, turning unit, feeding unit, vision system, clamping unit, spindle/cutting unit and cooling unit. And, these mechanisms have been modularized through mechanical, dynamical and structural optimized design using the SMO (SimDesigner Motion) analysis module. Also, the virtual prototype was carried out using the 3-D CAD program. The cutting process cycle is performed in the order of loading, vision processing, feeding, clamping, cutting and discharging. And the cycle time for cutting one piece was designed to be completed in four seconds.

An Experimental Study on the Accuracy of Concrete Unit-Water Content Using High-frequency Water Fraction Sensors (고주파수분센서를 이용한 콘크리트 단위수량 평가 정확도에 관한 실험적 연구)

  • Youn, Ji-Won;Lee, Seung-Yeop;Yu, Seung-Hwan;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.61-62
    • /
    • 2022
  • The unit quantity is an important factor influencing the durability, workability, and quality of concrete. Methods for measuring the unit quantity include a high frequency heating method, a unit volume mass method, a capacitance method, and a microwave method. However, these methods have disadvantages of poor measurement method, time required, and accuracy, and a relatively experimental method compensating for these disadvantages was used to measure the unit quantity using a high frequency main sensor (FDR) capable of simple and fast measurement. In addition, the unit quantity was evaluated by analyzing the measurement data through deep learning.

  • PDF

An Experimental Study on the Evaluation of Unit-Water Content Acoording to Concrete Aggregate Variables through FDR Sensor (FDR 센서를 통한 콘크리트 골재 변수에 따른 단위수량 평가에 관한 실험적 연구)

  • Youn, Ji-Won;Yu, Seung-Hwan;Yang, Hyun-Min;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.70-71
    • /
    • 2021
  • The unit quantity that affects the workability, shrinkage cracking, and durability of concrete is an important factor. Methods for measuring the unit quantity include a high frequency heating method, a capacitance method, a unit volume mass method, and a simple method. However, these methods have the disadvantage of poor measurement method, time required, and precision. To solve this problem, a relatively simple and fast measurement method was adopted to compensate for the shortcomings through a Frequency Domain Reflection (FDR) sensor, and the unit quantity was used. In addition, the measurement data was analyzed by deep learning to evaluate the unit quantity of concrete.

  • PDF

Assessing Unit Hydrograph Parameters and Peak Runoff Responses from Storm Rainfall Events: A Case Study in Hancheon Basin of Jeju Island

  • Kar, Kanak Kanti;Yang, Sung-Kee;Lee, Jun-Ho
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.437-447
    • /
    • 2015
  • Estimation of runoff peak is needed to assess water availability, in order to support the multifaceted water uses and functions, hence to underscore the modalities for efficient water utilization. The magnitude of storm rainfall acts as a primary input for basin level runoff computation. The rainfall-runoff linkage plays a pivotal role in water resource system management and feasibility level planning for resource distribution. Considering this importance, a case study has been carried out in the Hancheon basin of Jeju Island where distinctive hydrological characteristics are investigated for continuous storm rainfall and high permeable geological features. The study aims to estimate unit hydrograph parameters, peak runoff and peak time of storm rainfalls based on Clark unit hydrograph method. For analyzing observed runoff, five storm rainfall events were selected randomly from recent years' rainfall and HEC-hydrologic modeling system (HMS) model was used for rainfall-runoff data processing. The simulation results showed that the peak runoff varies from 164 to 548 m3/sec and peak time (onset) varies from 8 to 27 hours. A comprehensive relationship between Clark unit hydrograph parameters (time of concentration and storage coefficient) has also been derived in this study. The optimized values of the two parameters were verified by the analysis of variance (ANOVA) and runoff comparison performance were analyzed by root mean square error (RMSE) and Nash-Sutcliffe efficiency (NSE) estimation. After statistical analysis of the Clark parameters significance level was found in 5% and runoff performances were found as 3.97 RMSE and 0.99 NSE, respectively. The calibration and validation results indicated strong coherence of unit hydrograph model responses to the actual situation of historical storm runoff events.

The Characteristics of the Repair Unit Cost in Public Rental Housing (공공임대주택 단위 수선비용 특성 분석)

  • Lee, KangHee;Chae, ChangU
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.103-109
    • /
    • 2014
  • Apartment housing should require the systematic maintenance to provide the decent living condition during its life. Each household should participate the maintenance activities and pay for the repair. Therefore, the required cost for repair would be needed to plan in the repair schedule because each household could not pay the much repair money at a time. After apartment constructed, a long term repair plan would be prepared in repair time, repair scope and a required cost. A few studies are said that the repair cost depends on the building deterioration, elapsed year and management factors. The above factors are not be certain to affect the repair management while it may be important to prepare the required money and the repair time. In this paper, it aimed at analyzing the correlation between the repair management and the management factors, especially total area, number of household. This would educe the unit cost per number of household and management area in the individual boiler and elevator with full change and full repair. The unit cost per number of household and area for full change are about 199,000 won/household and $1,954won/m^2$ in the individual boiler respectively. The unit cost of the elevator for full change is 94,000 won/household and $5,429won/m^2$ respectively. Second, this study shows that the elapsed year after construction would not be related the repair unit cost.

A Study on Design and Application of High Response Solenoid for Unit Injector (유닛인젝터용 고속응답 솔레노이드 설계 및 응용에 관한 연구)

  • 황재원;양이진;정영식;이상만;채재우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.43-51
    • /
    • 1998
  • Most of fuel-injection system operated with mechanical methods are difficult to control the injection quantity and injection timing as well as injection rate exactly. Moreover high pressure injection scheme is never be realized with conventional one. On the other hand, serious air pollution can be lessened with injection system equipped with those functions. Therefore, electronically controlled Unit Injuctor(UI) appeared to satify above mentioned desires. However, it is still difficult that the most important part, especially solenoid valve, is analyzed precisely, because of the existence of complex combination of electromagnetics, electrics and dynamic problems. In this study, experimental and theoretical analysis are accomplished for understanding of solenoid valve characteristics and further its design. As the result, the follows are obtained 1) As the increase of wire diameter, the response time became shorter and optimal inductance existed in relative with the response time and wire diameter. 2) According to increasing input voltage, the traction force increased, otherwise the response time was shortened. 3) As the increase of armature stroke, the traction force decreased and the response time became longer.

  • PDF

Change of Clinical Effect upon Use of Glutamine to Critically Ill Patients over Age 60 Receiving TPN (정맥영양 투여 받는 60세 이상 중환자에서 glutamine 사용에 따른 임상 효과의 변화)

  • Lee, Hye Seung;Kim, Sungtae;Min, Young Sil;Sohn, Uy Dong
    • Korean Journal of Clinical Pharmacy
    • /
    • v.24 no.1
    • /
    • pp.9-14
    • /
    • 2014
  • Background: It is known to reduce the mortality when glutamine is supplied to patients during the surgery or in intensive care unit through intravenous nutrition supply. The purpose of this study is to establish the appropriate basis for use of glutamine and guidelines of nutrition supply for critically ill patients in the hospital by examining the clinical effects of administration of glutamine with subjects of elderly critically ill patients receiving intravenous nutrition in one hospital in Korea. Method: Among elderly patients with age of 60 or more hospitalized in Yeuido St. Mary's Hospital from August 2012 to July 2013, those who stayed in the intensive care unit for more than a week and received TPN (Total Parenteral Nutrition) for more than 3 days during staying in the intensive care unit were classified to a test group using glutamine and a control group without glutamine. Duration of use of mechanical ventilator, duration of hospitalization, occurrence of infectious disease and death were compared between two groups. We would like to identify the clinical test figures affected by the use of glutamine by examining changes in SCr, Total Protein, Albumin, AST, ALT, TB, DB and GFR at the time of admission and discharge. Results: At the time of admission to intensive care unit, gender, physical measurement information and clinical test figures did not show any significant difference between 72 subjects in a test group and 24 subjects in a control group. Thus, two groups began in the same condition. There were no significant difference in duration of hospitalization, duration of intensive care unit, use of mechanical ventilator, occurrence of infectious disease and death. As the results of statistical analysis of the average changes of clinical test figures at the time of admission and discharge of intensive care unit, SCr and GFR were significantly changed in the test group. GFR was significantly changed in a control group. As the result of analysis of the clinical test figures at the time of discharge with reflection of average changes after clinical test figures were corrected at the time of admission of intensive care unit, TB and GFR were significantly increased in a test group compared with those in a control group. Other clinical test figures were not significantly changed. Conclusion: If glutamine is administered to critically ill patients over age 60 receiving TPN and careful monitoring for total bilirubin is made in the future, it is expected to give the positive effect on renal function andminimize the side effect of arise in total bilirubin.