• 제목/요약/키워드: unit pulse

Search Result 333, Processing Time 0.113 seconds

The Effects of Low-intensity Ultrasound on TGF-$\beta$1 Expression and Healing of Rat Femur Fracture (저강도 초음파가 흰쥐 대퇴골 골절치유와 TGF-$\beta$1의 발현에 미치는 영향)

  • Nam, Ki-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.4
    • /
    • pp.97-102
    • /
    • 2009
  • Purpose: The purpose of this study was to investigate the effects of low intensity pulsed ultrasound on TGF-$\beta$1 expression and healing of rat femur penetrating fractures. Methods: Rats were anesthetized with ketamine and xylazine. Using aseptic technique, we exposed the lateral right femoral diaphysis with removal of the periosteum. We made one hole along its long axis with an electrically-driven 1.8 mm diameter drill bit. Postoperatively, rats were divided into two groups (a control group, n=15; an experimental group, n=15). The experimental group was treated with low intensity pulsed ultrasound (pulse rate: 1:4, 0.5 W/$cm^2$, 10 minutes, 1 time per day) for 3 weeks. The control group was treated with sham ultrasound (with the US unit turned off). Results: The experimental group achieved more callus formation and TGF-$\beta$1 expression than the control group at the $7^{th}$, $14^{th}$ and $21^{st}$ days after low intensity pulsed ultrasound treatment. Conclusion: This study suggests that low intensity pulsed ultrasound facilitates bone fracture repair, possibly via increased TGF-$\beta$1 expression.

  • PDF

Prevalence and Characterization of Vancomycin-Resistant Enterococci in Chicken Intestinles and Humans of Korea

  • Seong, Chi-Nam;Shim, Eun-Sook;Kim, Shin-Moo;Yoo, Jin-Cheol
    • Archives of Pharmacal Research
    • /
    • v.27 no.2
    • /
    • pp.246-253
    • /
    • 2004
  • The prevalence, genotype for antibiotic resistance and antibiotic susceptibility of vancomycin resistant enterococci (VRE) were determined. And molecular typings of the Enterococcus faecium isolates were analyzed. Prevalence of VRE in chickens, healthy children and intensive care unit (ICU) patients was 41.6%,7.9%, and 20.4%, respectively. Forty out of 54 isolates from chicken intestines, and 9 out of 11 from ICU patients were identified as Enterococcus faecium. Eleven out of 13 isolates from non-hospitalized young children were E. gallinarium. Twelve strains of E. faecalis were isolated from chicken intestines. The gene for the antibiotic resistance in E. faecium, and E. faecalis was vanA, while that in E. gallinarium was vanC1. E. faecium isolates were resistant to most of antibiotics except ampicillin and gentamicin. Molecular typing of the E. faecium strains obtained by pulse field gel electrophoresis and repetitive sequence-based PCR suggest that VRE transmit horizontally from poultry to humans, especially young children, via the food chains in Korea.

Engineering Properties of No-fines Concrete (No-fines Concrete의 공학적 특성)

  • 민정기;성찬용;김성완
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.1
    • /
    • pp.73-80
    • /
    • 1995
  • This study was carried out to investigate the engineering properties of no-fines con- crete, consisting only of coarse aggregate, cement and water. The used coarse aggregates were two, one is natural coarse aggregate grading 4.75~ lOmm, the other is synthetic lightweight coarse aggregate grading 3~8mm. The results of this study are summarized as follows; 1. The W/C ratio of each type was increased with increase of additional amount of coarse aggregate. 2. The unit weight of used ndtural coarse aggregate was shown 1.762~2.184g/cm$^3$, and synthetic lightweight coarse aggregate was shown 0.756 ~ 1 .348g/cm$^3$. 3. The ahsorption rate of used natural coarse aggregate was shown 8.4 ~ 9.4 %, and synthetic lightweight coarse aggregate was shown 17.0~42.4%. 4. The compressive, tensile and hending strength was decreased with increase of coarse aggregate, respectively. The compressive strength of natural coarse aggregate 1:3 was shown 309kg/cm$^2$. 5. The ultrasonic pulse velocity and dynamic medulus of elasticity of each type was de- creased with increase coarse aggregate, respectively. Also, the decreasing rate of the natural aggregate was larger than that of the synthetic lightweight coarse ag- gregate.

  • PDF

충격하중을 받는 유한평판의 3차원 동탄성이론에 의한 응력해석

  • 양인영;김선규;박정수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.51-64
    • /
    • 1991
  • In this paper, an attempt is made to analyze the impulsive stress directly underneath the concentrated impact point for a supported square plate by using the three-dimensional dynamic theory of elasticity and the potential theory of displacement (stress function) on the supposition that the load, F$_{*}$0 sin .omega.t, acted on the central part of it. The results obtained from this study are as follows: 1. The impulsive stress cannot be analyzed directly underneath the acting point of concenrated impact load in privious theories, but can be analyzed by using the three-dimensional dynamic theory of elasticity and the potential theory of displacement. 2. Theorically, with increasing the pulse width of applied load, it was possible to clarify that the amount of stress in the point of concentrated impact load was increased and that of stress per unit impulse was decreased. 3. The numerical inversion of laplace transformation by the use of the F.F.T algorithm contributes the reduction of C.P.U time and the improvement of the accuracy or results. 4. In this paper recommended, it is found that the approximate equation of impact load function P (.tau.) = A.tau. exp (-B.tau.), and P (.tau.) =0.85A exp (-B.tau.) sinC.tau. could actually apply to all impact problem. In compared with the experimental results, the propriety of the analytical method is reasonable.

  • PDF

A Data Acquisition System based upon a Single-board Microcomputer (단일보드 마이크로 컴퓨터를 이용한 자료(資料) 수집장치(蒐集裝置))

  • Choi, C.H.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.4
    • /
    • pp.221-228
    • /
    • 1989
  • A data acquisition system was designed to measure the forces on a rolling coulter in three coordinated directions, angular velocity of the coulter and travel speed of a soil bin. The data acquisition system consisted of a dynamometer, speed transducers, a signal conditioner, an inter-face board, an Aim-65 microcomputer and a digital data recorder. Strain gages were attached on the surface of the dynamometer and connected to form three Wheatstone bridges, which measure the draft force, the vertical force and the side force on the coulter. An interaction among three dimensional forces was found during the calibration. A matrix procedure was used to correct the forces for this interaction. Rotary shaft encoders were mounted on the coulter and on the soil bin drive to measure the angular velocity of the coulter and the travel speed of the soil bin. The angular velocity and the travel speed were computed by counting the number of pulse signals from the rotary shaft encoders every 0.2 second. The digital signals from the rotary shaft encoders were connected to counters and the analog signals from the dynamometer, after passing through the signal conditioner, were connected to the A/D converter. The microcomputer programs, written in assembly language, were developed to read signals from the transducers, convert them to actual unit, display them upon request and record them on a sigital tape every 0.2 second.

  • PDF

Design and Test of On-Board Flight Data Acquisition System based on the RS485 Star Network (RS485 Star 구조의 비행체 탑재용 데이터 수집시스템 구현 및 성능시험)

  • Lee, Sang-Rae;Lee, Jae-Deuk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.83-90
    • /
    • 2004
  • This paper describes on-board decentralized data acquisition system that acquires and encodes the numerous sensor data distributed on the big flight vehicles efficiently. The system's sub-units which have one encoder unit and several remote units were designed and simulated according to the communication protocols and the control, sequence logics based on the FPGA chip. And we have made the functional verification of the acquisition, collection and formatting of remote analog and digital data for the manufactured hardwares.

Analysis of electric circuit using capacitor for driving linear compressor (콘덴서를 이용한 선형압축기 구동 전기회로 해석)

  • Ko, Jun-Seok;Kim, Hyo-Bong;Park, Seong-Je;Hong, Yong-Ju;Yeom, Han-Kil;Koh, Deuk-Yong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.43-47
    • /
    • 2012
  • A linear compressor generates pulsating pressure and oscillating flow in a cryocooler such as Stirling cryocooler and pulse tube refrigerator. It is driven by AC power source and designed to operate at resonance of piston motion. The driving voltage level is determined by electric parameters of resistance, inductance and thrust constant of linear motor. From voltage equation on linear motor, the power factor of driving power is inherently less than 1. The phase difference between voltage and current of supplied power can be zero using capacitor and this can minimize a supply voltage level. Especially, the linear compressor of kW class requires high voltage and thus can cause a difficulty in selecting power supply unit due to limitation of voltage level. The capacitor in driving electric circuit is useful to settle this problem. In this study, the electric circuit of linear compressor is analytically investigated with assumption of mechanical resonance. The electric parameters of commercial linear motor are used in the analysis. The effects of capacitor on driving voltage level and power factor are investigated. From analytic results, it is shown that the voltage level can be mimized with using capacitor in driving electric circuit.

Optimization of panel parameters and drive signals for high-speed matrix addressing of a bistable twisted-nematic LCD (쌍안정 TN LCD의 고속 매트릭스 어드레싱을 위한 패널 파라미터와 구동 파형의 최적화)

  • 이기동;박구현;장기철;윤태훈;김재창;이응상
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.417-422
    • /
    • 1998
  • In this paper we introduce a method to optimize panel parameters and drive signals in a matrix-adressed bistable twsited-nematic (BTN) liquid crystal display (LCD) panel. We measured the effect of data pulses on optical switching characteristics in a BTN LC cell to model the effect theoretically. We introduce a weighting function to model the effect of data pulses on the switching energy as a function of time. Once the weighting function is known, we can estimate the maximum number of lines for multiplexing operation at a given frame rate by calculating the minimum data pulse width. By characterizing a unit cell as we change panel parameters (for example, d/p ratio), we can optimize parameters for high-speed operation. We found that our theoretical predictions agree very well with experimental results.

  • PDF

Study on High Efficiency EEFL Backlight inverter for 32-inch LCD TV

  • Oh, Won-Sik;Cho, Kyu-Min;Moon, Gun-Woon;Min, Sook-Kyu;Kim, Hyun-Jin;Jeon, Hyoung-Jun;Kim, Jong-Sun;Mim, Byoung-Woon
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.405-407
    • /
    • 2005
  • As the screen size of LCD increases, EEFL(External Electrode Fluorescent Lamp) has been suggested to be applicable as backlight source for LCD . Since the electrodes of EEFL are outside of the tube, EEFL enhances the lifetime compared with CCFL(Cold Cathode Fluorescent Lamp), and a single inverter can drive multiple EEFL tubes of which luminance is uniform Therefore, a compact design can be realized and the cost of EEFL application would be much lower than that of CCFL. Moreover, EEFL inverter has higher efficiency per unit power than CCFL inverter. In this paper, a complementary full-bridge PWM(Pulse Width Modulation) inverter was designed for 32-inch LCD TV backlight which has 20 EEFL tubes and adapted two different driving methods to the EEFL inverter. The validity of this study is confirmed from the experimental results.

  • PDF

Classification and Compensation of DC Offset Error and Scale Error in Resolver Signals

  • Lee, Won;Moon, Jong-Joo;Im, Won-Sang;Park, June-Ho;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1190-1199
    • /
    • 2016
  • This study proposes a classification and compensation algorithm of two non-ideal output signals of a resolver to reduce position errors. Practically, a resolver generates position errors because of amplitude imbalance and quadrature imperfection between the two output signals of the resolver. In this study, a digital signal processor system based on a resolver-to-digital converter is used to reconstruct the two output signals of the resolver. The two output signals, "sin" and "cos," can be represented by a unit circle on the xy-plot. The classification and compensation of the errors can be obtained by using the radius and area of the circle made by the resolver signals. The method computes the integration of the areas made by the two resolver output signals to classify and compensate the error. This system cannot be applied during transient response given that the area integration during the transient state causes an error in the proposed method. The proposed method does not need any additional hardware. The experimental results verify the effectiveness of the proposed algorithm.