• Title/Summary/Keyword: unit pulse

Search Result 333, Processing Time 0.032 seconds

A Study on the Level Limit Switch for Measuring Near-distance Variation with 1-3 Type Ceramic/Polymer Composite Ultrasonic Transducer (1-3형 복합압전체 초음파 트랜스듀서를 사용한 근접거리변동 측정용 레벨 Limit스위치에 관한 연구)

  • Kim, H.G.;Park, K.I.;Shin, K.H.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.103-106
    • /
    • 2003
  • In this study, an ultrasonic transducer is fabricated with 1-3 type composite resonators. Pulse-echo responses of an ultrasonic transducer are investigated in underwater dependent on the variable designated water-level. LED Output signals of a level limit with changing a water level is obtained by the 1-3 type self-made composite transducer and electric measuring unit. LED is turned on at above the up-limit level with increasing a water level, and LED is turned on at less than the down-limit level with decreasing a water level. There was good agreement between the virtual water level and output LED signal by using the self-made water-detecting system.

  • PDF

Development of Multi-wavelength Laser Medical Therapy Apparatus (다파장 레이저치료기의 개발)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil;Lee, Ho-Sik;Kim, Tae-Gon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.736-741
    • /
    • 2007
  • Low level laser therapy has various therapy effects, This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 660nm, 785nm and 850nm laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. To raise the stimulus effect of the human body, the optical irradiation frequency could be set up. In result, the $1{\sim}10\;Hz$ irradiation frequency could be controlled stably.

Design and Implementation of a Microwave Motion Detector with Low Power Consumption

  • Sohn, Surg-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.7
    • /
    • pp.57-64
    • /
    • 2015
  • In this paper, we propose a design of microwave motion detector using X-band doppler radar sensor to minimize the power consumption. To minimize the power consumption and implement battery operated system, pulse input with 2 KHz, 4% duty cycle is exerted on the doppler radar sensor. In order to simplify the process of working with ATmega2560 microcontroller unit, Arduino compatible board is designed and implemented. Arduino is open source hardware and many library software is published as open source tools. Smartphone app is also proposed and designed as a real-time user interface of the motion detector. The SQLite database on the Android mobile operating system is used for recording raw data of motion detection for post-processing job, such as fast Fourier transform (FFT). Bluetooth interface module is implemented on the motion detection board as a wireless communication interface to the smartphone. The speed of human movement is identified by post-processing FFT.

A Study for the Equivalent Circuit of Linear Pulse Motor (리니어펄스모터의 등가회로에 관한 연구)

  • Kim, Sung-Do;Kim, Jung-Chul;Im, Tae-Bin;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.184-186
    • /
    • 1997
  • This paper proposes the analysis method considered the eddy current which is induced by the speed of LPM. To investigate reduction effect of thrust due to the eddy current, the magnetic equivalent circuit of LPM is modeled and its characteristics is analyzed according to the displacement of mover with the speed term when LPM is driven by the input of unit step and microstep.

  • PDF

Experimental Study on physical and Mechanical Properties of Concrete with Fly Ash (플라이 애시를 혼입한 콘크리트의 물리.역학적 특성에 관한 실험적 연구)

  • 성찬용
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.3
    • /
    • pp.107-113
    • /
    • 2000
  • This study is performed to examine the physical and mechanical properties of concrete with fly ash. Test results show that the unit weights of concrete with fly ash are decreased 1-3% and the highest strength is achieved by 10% filled fly ash concrete with it is increased 7% than that of the normal cement concrete. the ultrasonic pulse velocity is in the range of 3.705~4.204m/s and the dynamic and static modulus of elasticity is in the range of 271$\times$103 ~289$\times$103kgf/cm2 and 208$\times$103 ~262$\times$103kgf/cm2 respectively. The acid-resistance is increased with increase of the content of fly ash. It is 1.2 times of the normal cement concrete by 10% filled fly ash concrete and 1.7 times by 30% filled fly ash concrete respectively.

  • PDF

Development of 3 Phase PWM Converter using Analog Hysteresis Current Controller (아날로그 히스테리시스 전류 제어기를 적용한 3상 PWM 컨버터 개발)

  • Lee Young-kook;Noh Chul-won
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.372-376
    • /
    • 2001
  • Due to several advantages of Pulse Width Modulation(PWM) Converter, such as unity power factor operation, elimination of low-order harmonics and regeneration of motor braking energy to source, the application range of PWM Converter has been rapidly extended in industrial application. Nowadays, vector control algorithm and space vector PWM(SVPWM) method are applied to improve the performances of PWM Converter, but vector control algorithm and SVPWM require to use Microprocessor and other digital devices in hardware, causing costly and somewhat large dimension system. In every practical application of energy conversion equipments, the design and implementation should be carried out considering cost and performance. High performance and low cost is the best choice for energy conversion equipments. So, this paper presents the practical design method and implementation results of 3-phase PWM Converter with analog hysteresis current controller, and verifies the performances of unit power factor operation and energy regeneration operation via experimental results.

  • PDF

The Implementation of A Therapy Radiation Dose Measurement System Using A Microcomputer (마이크로컴퓨터를 이용한 치료방사선 선량측정 시스템의 구현)

  • Lee, D.H.;Kwon, O.S.;Hong, J.P.;Chae, C.S.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.15-17
    • /
    • 1996
  • In this paper, the therapy radiation dose measurement system has been implemented by using a microcomputer after radiation was irradiated on diodes from the MM22 microtron accelerator. We have displayed 7-channel diode output values on the LCD after processing those in the 80196 MCU(Micro Computer Unit). Signal processing has been performed in the pulse mode because we can process the signal fast and use it to perform portal image by increasing a number of diode channels in the future. In order to verify the microcomputer based radiation measurement system of diodes, diode output values were compared with that of semiconductor.

  • PDF

A Study on the Temperature Measurement Using Optical Emission in Saline Solution Discharge with Pin to Plate Electrodes (염류용액 방전의 온도 측정에 관한 연구)

  • Kim, Joong Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.66-71
    • /
    • 2016
  • In this study, electrical and spectroscopic characteristics were investigated in the pin to plate discharge of 0.9% weight per unit volume saline solution. The positive and positive- and negative-going dc pulse with 5% duty ratio were applied to tungsten pin electrode. The more amount of discharge current flew in negative discharge. The temperature, which is considered as a local value in the vicinity of vapor of discharge, was about 3,000K which is much higher than the value recommended to be controlled. It can be suggested that not only the temperature of liquid but also the local temperature of vapor is monitored to investigate damages on tissue or cells in biological application.

The Development of a Beam Steering System for X-band 2-D Phased Array Antenna (X-대역 2차원 위상배열안테나 빔조향 시스템 개발)

  • Kim, Doo-Soo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.92-98
    • /
    • 2008
  • A beam steering system of X-band 2-D phased array antenna for radar application is developed. The beam steering system consists of real-time command generator, beam steering unit, control PCB of array module and power supply. It plays a role of beam steering and on-line check of phased array antenna. The performance of beam steering system is verified with pulse timing of current control in phase shifters and measurement of far-field of phased array antenna. The developed beam steering system offers basic technology to develop full-scale beam steering system of multi-function radar.

Development of Laser Diode Medical Therapy Apparatus for Blood Stream Improvement (혈류 개선용 레이저다이오드 치료기 개발)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.496-496
    • /
    • 2007
  • Low level laser therapy has various therapy effects. This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 7850m Laser diode for blood stream improvement and was designed for a pulse width modulation type to increase stimulation effects. In result, we could get the light power of 785nm wavelength.

  • PDF