• Title/Summary/Keyword: unit module

Search Result 832, Processing Time 0.028 seconds

A Study on the Architectural Design Method for ]Remodeling Vitalization of Apartment Rouses - Based on the Systematization of Emotion-Information for Multi-Dimensional Module Composition of the Unit household - (공동주택 리모델링 활성화를 위한 건축설계 기법에 관한 연구 - 단위세대 다차원모듈 구성을 위한 감성정보 체계화를 중심으로 -)

  • Jung Moo-Woong;Lee Chan-Yong
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.121-129
    • /
    • 2005
  • The major goal of this study is drawing design plan factors considering residents' life cycle and life style when remodeling design is needed. By drawing such design factors, the study will propose an alternative remodeling design plan. Such design method was defined as Multi-Dimensional module design method. And constructing data-system based on Multi-Dimensional module was secondary goal in this study. The details are as follows: Based on analysis of Residents' demand for remodeling and features of emotion-design applied to remodeling, the system which is suitable for application in remodeling design method was conducted. Based on the type of construction materials, the level value was set up according to emotion-factor application. Also, by conducting coding operation according to the distinction of construction materials, this study seeks the unit drawing method of information for constructing emotion-information system.

A Study of the Sungnam Moran Traditional Folk Market Project as the Urban Public Open Space (도시 공공공간으로서의 성남 모란 민속5일장 계획에 관한 연구)

  • Choi, Dong-Hyeog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.5134-5142
    • /
    • 2010
  • The purpose of this study is to explore the possibility of the planning method of traditional market as the urban public open space and to attempt to create the essential reformation of traditional market place. The design concepts of the Moran traditional market project are establishing module system based on function of traditional market to accomplish the practical needs of vendor and consumer and expressing the liquid and autonomic characteristics of Moran traditional market to find the new and substantial schemes of public open space. The functional design module of the market place is based on 2.1m $\times$ 2.1m grid system which is minium market unit, and it is extended to 8.4m $\times$ 8.4m basic structural module and to 50.4m $\times$ 50.4m plaza unit.

A Case Study on the Power Performance Characteristics of Building Integrated PV System with Amorphous Silicon Transparent Solar Cells (비정질 실리콘 투과형 태양전지를 적용한 BIPV 시스템 발전 성능에 관한 사례 연구)

  • Jung, Sun-Mi;Song, Jong-Hwa;Lee, Sung-Jin;Yoon, Jong-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.49-52
    • /
    • 2009
  • Practical building integrated photovoltaic system built by Kolon E&C has been monitored and evaluated with respect to power generation, which was installed in Deokpyeong Eco Service Area in Deokpyeong, Gyeonggi, Korea. The amorphous silicon transparent PV module in this BIPV system has 44Wp in power output per unit module and 10% of transmittance with the unit dimension with $980mm{\times}950mm$. The BIPV system was applied as the skylight in the main entrance of the building. This study provided the database for the practical application of the transparent thin-film PV module for BIPV system through 11 month monitoring as well as various statistical analyses such as monthly power output and insolation. Average monthly power output of the system was 52.9kWh/kWp/month which is a 60% of power output of the previously reported data obtained under $30^{\circ}$of an inclined PV module facing south(azimuth=0). This lower power output can be explained by the installation condition of the building facing east, west and south, which was resulted from the influence of azimuth.

  • PDF

A Study on Security Attribute Design in Security Plan of The Design Phase (설계단계의 보안 방안에서 보안 속성 설계에 대한 연구)

  • Shin, Seong-Yoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.5
    • /
    • pp.1125-1130
    • /
    • 2015
  • In this paper, a method to identify components per unit task system is expressed with node, module, and interface. We define security subject per unit task system and explain node, module, and interface per component. According to the defined security standard in design phase, we also perform to design and elaborate security attributes for node and module as identified security subjects in their defined tables. And then we describe the composition standard for security attribute design with some examples, after classifying it into security subject, access subject, access control area, identification or verification area, and encryption.

Improvement Method for Human Body Sensing Module and Managing System (인체 감지 센서 모듈 및 관리 시스템의 개선 방안)

  • Ahn, Tae-Won
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.223-227
    • /
    • 2014
  • This paper presents an improvement method for human body sensing module and management system, specifically focused on the human body detection module with ultrasonic sensors to detect the usage of toilets and the management system to control the state of the toilets of the entire building. The proposed human body sensing module consists of the detection sensor to detect the movement of human body and the contact sensor to detect the position in a certain distance. The management system is configured of the control unit to process the signal transmitted from sensors, opening and closing valves according to the sensing signal, and the short range wireless communication unit to save the operational status data as well as transmit the data at regular intervals.

Study On Design of Encoding Module for PLC input (PIC 입력 인코딩 모듈 설계에 관한 연구)

  • You, Jeong-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.105-110
    • /
    • 2005
  • Programmable Logic Controller(PLC) is the most widely utilized among many sorts of existing controller for the design of factory automation control system, and study about a PLC language is peformed actively. In this paper, we proposed the encoding module that we increase input points when increased of the input machine which is going to control it in the FA design that used PLC. Input point is going to be extended with 2-3 points in the state that cannot equip input unit in basic base any more. Then an extension base, a power supply, an extension cable and an output nit must be equipped particularly. Then a cost must be added very much. This paper proposed the encoding module which extended an input in a small quantity, and we confirmed a feasibility through a simulation.

Analysis on the Fire Accident of Vehicle Due to Damage of Connector and wiring on an Anti-lock Brake System(ABS) Module (ABS 모듈의 접속부 및 전원배선 손상으로 인한 차량화재 사고사례 분석)

  • Park, Nam-Kyu;Kim, Jin-Pyo;Nam, Jung-Woo;Park, Jong-Taek;Song, Jae-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.13-19
    • /
    • 2017
  • In this paper, study of vehicle fire cases caused by connector and power wiring of anti-lock brake system(ABS) module damage is presented. The purpose of ABS module is to improve braking and steering ability under sudden stop of the vehicle by repeatedly activating and releasing the brake with electric signal via electric control unit. The electric control unit for ABS may experience incomplete contact between power line and signal line or electrical breakdown on the printed circuit board by undergoing repetitive signal change which would consequently result in electrical heat and spark, eventually leading to automotive fire. Therefore, the purpose of this paper is to provide fundamental data by analyzing connector and power wiring of ABS module damage conducive to the precise investigation on the cause of vehicle fire.

An I/O Bus-Based Dual Active Fault Tolerant Architecture fort Good System Performance

  • Kwak, Seung-Uk;Kim, Jeong-Il;Jeong, Keun-Won;Park, Kyong-Bae;Kang, Kyong-In;Kim, Hyen-Uk;Lee, Kwang-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.515-520
    • /
    • 1998
  • In this paper, we propose a new fault tolerant architecture for high availability systems, where for module internal operations both processor modules perform the same tasks at the same time independently of each other while for module external operations both processor modules act actively. That is, operations of synchronization between dual processor modules except clock synchronization are requested only when module external operations are executed. The architecture can not only improve system availability by reducing system reintegration time but also reduce performance degradation problem due to frequent synchronization between dual processor modules. The clock unit consists of a clock generator and a clock synchronization circuit. This supplies a stable clock signal under clock unit disorder of any processor module or rapid clock signal variation. And this architecture achieves system availability and data credibility by designing as symmetrical form.

  • PDF

Architectural Planning Study on Spatial Composition of Mobile Seclusion Module - Based on Modular Construction System (이동형 안정실 모듈의 공간구성에 대한 건축계획적 연구 - 모듈러 건축 공법을 기반으로)

  • Kim, Sung Hyun;Yang, Nae-won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.2
    • /
    • pp.49-60
    • /
    • 2023
  • Purpose: This study aims to establish detailed spatial planning by identifying the needs for a seclusion module for emergency psychiatric patients. Methods: The necessity of medical space with seclusion function was analyzed from spatial, medical, and social perspectives. The needs for a space capable of performing three medical functions: protection, isolation, and treatment, was analyzed. Among various types of mobile medical facilities, seclusion space was considered suitable for utilizing modular construction methods, as it is the most rational method that can satisfy the environmental level of fixed healthcare facilities' space. Therefore, seclusion modules based on modular construction were planned, consisting of two protective units for stabilizing patients with psychiatric illness, one for treatment unit that can accommodate both internal and external treatment, and another one for an infectious disease isolation unit equipped with negative pressure equipment. Implications: This study analyzed the necessary medical functions of the interior space of the mobile stabilization module based on the spatial analysis of existing medical facilities, and proposed alternative spatial configurations according to treatment, seclusion, isolation functions.

A comparative analysis of load behavior of the fixing equipments for transporting unit modules (유닛모듈 운반용 고정장치의 하중거동 비교 분석)

  • Kim, Kyoon-tai;Kim, Seok;Jun, Young-Hun;Kim, Tae-Yeong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.146-147
    • /
    • 2015
  • This paper compares load behavior of two fixing equipments for transporting unit modules. The suggested fixing equipment shows higher limit load than an existing fixing equipment, which proves that the suggested fixing equipment have higher safety.

  • PDF