• Title/Summary/Keyword: unipolar

Search Result 226, Processing Time 0.027 seconds

A PLL with an unipolar charge pump and a loop filter consisting of sample-hold capacitor and 2nd-order RC filter (2차-RC 필터와 Sample-Hold 커패시터로 구성된 루프 필터와 단방향 전하펌프를 가진 PLL)

  • Baek, Seung-Ha;Choi, Young-Shig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2380-2386
    • /
    • 2013
  • A PLL with an unipolar charge pump and a loop filter consisting of sample-hold capacitor and 2nd-order RC filter has been proposed. The goal of the proposed PLL is the suppression of reference spur which is caused by charge pump mismatch. It also improves phase noise characteristic. It has been designed with a 1.8V $0.18{\mu}m$ CMOS process and proved by HSPICE simulation.

Investigation on the Electrical Discharge Characteristics of a Unipolar Corona-Wire Aerosol Charger

  • Intra, Panich;Yawootti, Artit;Vinitketkumnuen, Usanee;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.556-562
    • /
    • 2011
  • In the present study, a simple corona-wire charger for unipolar diffusion charging of aerosol particles is designed, constructed, and characterized. Experimental characterizations of the electrostatic discharge in terms of current-voltage relationships of positive and negative coronas of the corona-wire charger are also presented and discussed. The charging current and ion concentration in the charging zone increased monotonically with corona voltage. The negative corona showed higher current than the positive corona. At the same corona voltages, the current in the discharge zone is about 600 times larger than the charging current. The ion number concentrations ranged within approximately $5.0{\times}10^{10}$ to $1.24{\times}10^{16}$ and $4.5{\times}10^{12}$ to $2{\times}10^{16}$ ions/$m^3$ in the discharge and charging zones, respectively. A numerical model is used to predict the behavior of the electric potential lines. Numerical results of ion penetration through the inner electrode are in good agreement with the experimental results.

Efficiency of the Hybrid-type Air Purifier on Reducing Physical and Biological Aerosol (복합식 공기청정기의 물리적 및 생물학적 입자상 물질의 제거 효과)

  • Kim, Ki-Youn;Kim, Chi-Nyon;Kim, Yoon-Shin;Roh, Young-Man;Lee, Cheol-Min
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.478-484
    • /
    • 2006
  • There was no significant difference in the CADR (Clean Air Delivery Rate) between physical aerosols, NaCl and smoke, and biological aerosols, airborne MS2 virus and P. fluorescens, which implicate that the hybrid-type of air purifier, applying the unipolar ion emission and the radiant catalytic ionization, imposed identical reduction effect on both physical aerosol and bioaerosol. Ventilation decreases the efficiency of air cleaning by unipolar ionization because high ventilation diminishes the particle concentration reduction effect. The particle removal efficiency decreases with increase in the chamber volume because of the augmented ion diffusion and higher ion wall loss rate. Particle size affects the efficiency of air ionization. The efficiency is high for particles with very small diameter because reduction of charge increases with particle size. If there is no increasing supply of ions, the efficiency of air cleaning by unipolar ionization increases with respect to initial concentration of particles because of the large space charge effect at high particle concentration and amplified electric field.

A Case of Disappearing Symptoms Developed Repetitively in a Complete Atrioventricular Block Patient Implanted Bipolar Permanent Pacemaker After Converting It into Unipolar System (완전방실블록 환자에서 쌍극의 영구박동기를 이식후 반복 발생된 증상이 단극으로 전환후 증상이 소실된 예)

  • Kweon, Jun-Young;Choi, Kyo-Won;Sin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.1
    • /
    • pp.181-185
    • /
    • 1994
  • Pacemaker malfunctions are secondary to alterations of the preset pacing rate, irregular pacing failure of sensing, failure of cardiac capture or depolarization, and various combinations of these events. A 76 years old male patient was admitted due to pacemaker malfunction. 2 years ago, he was diagnosed as complete atrioventricular block. And then bipolar permanent pacemaker was implanted. Since then syncopal attack developed repetitivly. 12 lead ECG and 24 hour holter moniter monitoring, revealed pacing and sensing failure, thus we converted bipolar system into unipolar system. Since then syncopal attack did not developed again.

  • PDF

Effects of Particle Shapes on Unipolar Diffusion Charging of Non-Spherical Particles (비구형 입자의 형상에 따른 단극 확산 하전 특성)

  • Oh, Hyun-Cheol;Park, Hyung-Ho;Kim, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.5
    • /
    • pp.501-509
    • /
    • 2004
  • Unipolar diffusion charging of non-spherical particles was investigated for various particle shapes. We researched with TiO$_2$agglomerates produced by the thermal decomposition of titanium tetraisopropoxide (TTIP) vapor. TTIP was converted into TiO$_2$, in the furnace reactor and was subsequently introduced into the sintering furnace. Increasing the temperature in the sintering furnace, aggregates were restructured into higher fractal dimensions. The aggregates were classified according to their mobility using a differential mobility analyzer. The projection area and the mass fractal dimension of particles were measured with an image processing technique performed by using transmission electron microscope (TEM) photograph. The selected aggregates were charged by the indirect photoelectric-charger and the average number of charges per particle was measured by an aerosol electrometer and a condensation particle counter. For the particles of same mobility diameter, our results showed that the particle charge quantity decreases as the sintering temperature increases. This result is understandable because particles with lower fractal dimension have larger capacitance and geometric surface area.

Study on the Shift in the P-E Hysteresis Curve and the Fatigue Behavior of the PZT Capacitors Fabricated by Reactive Sputtering (반응성 스퍼터링법으로 형성시킨 PZT 커패시티의 P-E 이력곡선의 이동현상 및 피로 특성 연구)

  • Kim, Hyun-Ho;Lee, Won-Jong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.11
    • /
    • pp.983-989
    • /
    • 2005
  • [ $PZT(Pb(Zr,Ti)O_3)$ ] thin films were deposited by multi-target reactive sputtering method on $RuO_2$ substrates. Pure perovskite phase PZT films could be obtained by introducing Ti-oxide seed layer on the $RuO_2$ substrates prior to PZT film deposition. The PZT films deposited on the $RuO_2$ substrates showed highly voltage-shifted hysteresis loop compared with the films deposited on the Pt substrates. The surface of $RuO_2$ substrate was found to be reduced to metallic Ru in vacuum at elevated temperature, which caused the formation of oxygen vacancies at the initial stage of PZT film deposition and gave rise to the voltage shift in the P-E hysteresis loop of the PZT capacitor. The fatigue characteristics of the PZT capacitors under unipolar wane electric field were different from those under bipolar wane. The fatigue test under unipolar wane showed the increase of polarization. It was thought that the ferroelectric domains which had been pinned by charged defects such as oxygen vacancies and the charged defects were reduced in number by combining with the electrons injected from the electrode under unipolar wave, resulting in the relaxation of the ferroelectric domains and the increase of polarization.

Development of Titanium Metal Surface Anodizing Equipment (티타늄 금속 표면 양극산화장치 개발)

  • Yang, Keun-Ho;Min, Byung-Woon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.9
    • /
    • pp.1307-1312
    • /
    • 2013
  • In this paper, alkaline or acidic solution, in particular the principle of electrolysis to oxidize the metal surface to form a device isolation film is developed. In the past, mainly in the form of pulse voltage is applied to the anode only a unipolar method, but in this paper by using the H-bridge to the amount of the positive (+) voltage and the negative supply voltage, alternating voltage polarity devices were fabricated according to the characteristics of metal specimens with different electrical conditions to form an oxide film on the device was developed. Supply current variable was used for the PWM modulation, (+) and (-) polarity change of the H-bridge bipolar pulse voltage to supply the was that. As a result, a more uniform pores with unipolar film was formed.

Cardiac Surgery for the Patient with VVI Unipolar Pacing System -One Case- (VVI 단극유도의 심박조율치를 가진 환자의 개심술 -1례 치험-)

  • 정해동;최종범;최형호
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.398-401
    • /
    • 1998
  • A 56-year-old female with a permanent unipolar pacing(VVI) system underwent elective coronary bypass surgery and mitral valve replacement. Because the unipolar sensing is subject to considerable nonmyocardial electrical noise, the pacing function may be disturbed by the use of electrocautery. Temporary atrial and ventricular bipolar epicardial leads and external generator were used for maintaining A-V sequential pacing during the use of electrocautery. Before aortic cross-clamp was released after cardiac operation, regular cardiac rhythm could spontaneously be resumed with an integrated cardioplegic strategy, avoiding the use of defibrillator

  • PDF

Inkjet Printing of Small Droplets Using M-shaped Waveforms (M-shaped 파형을 이용한 작은 액적의 잉크젯 프린팅)

  • Hong, Songeun;Choi, Jiho;Kim, Gieun;Park, Jongwoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.51-56
    • /
    • 2021
  • Using an inkjet printing process, we have investigated a droplet formation of poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS) near the orifice of a piezoelectric inkjet head. With an attempt to form the smallest droplet without any satellites, we have applied various waveforms such as the unipolar, bipolar, and M-shaped waveforms. It is found that the droplet velocity and volume vary depending sensitively on the waveform width and voltage. Of those, the M-shaped waveform is shown to provide the smallest droplet volume, followed by the bipolar and then unipolar waveforms. The droplet printed on a PET film roll by the M-shaped waveform has the diameter as small as 46.1 ㎛. It is likely that the second short unipolar in the M-shape waveform increases the droplet velocity gradient, rendering the droplet smaller.

Effect of process conditions on crystal structure of Al PEO coating. I. Unipolar pulse and coating time (알루미늄 PEO 코팅의 결정상에 미치는 공정 조건에 대한 연구 I. Unipolar 펄스와 코팅시간)

  • Kim, Bae-Yeon;Ham, Jae-Ho;Lee, Deuk Yong;Kim, Yong-Nam;Jeon, Min-Seok;Kim, Kiyoon;Choi, Ji-Won;Kim, Sung Youp;Kim, Kwang Youp
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.2
    • /
    • pp.59-64
    • /
    • 2014
  • Crystallographic phases of Plasma electrolytic oxidized Al alloy, A1050, were investigated. The electrolyte of PEO was $Na_2Si_2O_3$ and KOH. Unipolar pulse, $ 2000{\mu}sec$ with $400{\mu}sec+420V$ impulse, were applied for 2 min, 5 min, 15 min, and 30 min. ${\gamma}-Alumina$, as well as ${\alpha}-alumina$, was main crystal phase. ${\gamma}-Alumina$ was appeared in the beginning, then the amount of ${\alpha}-alumina$ was increased with time, but the amount of ${\gamma}-Alumina$ remained constant without any increasing. So, it is concluded that plasma gas produce ${\gamma}-Alumina$ at the first, and then ${\gamma}-Alumina$ transform ${\alpha}-alumina$ finally. During the transformation, high temperature of micro plasma gives transformation energy.