• 제목/요약/키워드: uniform size

검색결과 1,480건 처리시간 0.081초

Medical Data Based Clinical Pathway Analysis and Automatic Ganeration System (임상데이터기반 표준진료지침 자동 생성 시스템 분석 및 연구)

  • Park, Hanna;Bae, In Ho;Kim, Yong Oock
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제39C권6호
    • /
    • pp.497-502
    • /
    • 2014
  • In general, all physicians have some standardized diagnosis and treatment methods. However, there are differences in the precise order and examination depending on the hospital size, system, medical equipment, etc. To reduce this difference, the interest about standardized guidelines recently increased and a variety of research is being conducted. The uniform guideline cannot reflect the differences of each situation and environment to meet the hospitals. Therefore, standardized medical guidelines(=clinical pathway) should provide customized guidelines based on the relevant medical data to ensure the quality of the medical service and the doctor's autonomy. In this paper, we will analyze medical data made by two thyroid specialists in the same hospitals. Moreover, this paper mentions the implement of automatic generating clinical pathway system which consider its real hospital situation and result.

Optimization of Silver Nanoparticles Synthesis through Design-of-Experiment Method (실험계획법을 활용한 은 나노 입자의 합성 및 최적화)

  • Lim, Jae Hong;Kang, Kyung Yeon;Im, Badro;Lee, Jae Sung
    • Korean Chemical Engineering Research
    • /
    • 제46권4호
    • /
    • pp.756-763
    • /
    • 2008
  • The aim of this work was to obtain uniform and well-dispersed spherical silver nanoparticles using statistical design-of-experiment methods. We performed the experiments using 2 k fractional factorial designs with respect to key factors of a general chemical reduction method. The nanoparticles prepared were characterized by SEM, TEM and UV-visible absorbance for particle size, distribution, aggregation and anisotropy. The data obtained were analyzed and optimized using a statistical software, Minitab. The design-of-experiment methods using quantified data enabled us to determine key factors and appreciate interactions between factors. The measured properties of nanoparticles were dominated not only by individual one or two main factors but also by interactions between factors. The appropriate combination of the factors produced small, narrow-distributed and non-aggregated silver nanoparticles of about 30 nm with approximately 10% standard deviation.

A Study on the Characterization of the Mixed-Oxide Prepared from Monazite (모나자이트로부터 파생된 희토류 혼합산화물의 특성)

  • Kwon, Young Sik;Kim, Yeun Sik;Kim, Dong Su
    • Journal of the Korean Chemical Society
    • /
    • 제39권12호
    • /
    • pp.946-954
    • /
    • 1995
  • The physico-chemical nature of the rare earth oxide which was produced by the caustic fritting of monazite was studied to furnish fundamental data that are required for its efficient use and processing. It was found that the material which was mainly constituted of light rare earths and thorium was a solid solution phase of oxide whose structure was fluorite-type face centered cubic. Its density was 6.75 g/$cm^3$ and it had a uniform particle size distribution at around 1 ${\mu}m.$ The crystallinity improved by heating to elevated temperatures, whereas the solubility in HCl decreased as the crystallinity improved. Complete dissolution in conc. HCl solution in short time (30 min.) was attained by heating to 70$^{\circ}C$. The measurement of zeta potential showed its I.E.P. to be at pH 8.6 of the suspension.

  • PDF

Synthesis of Cd1-xZnxS/K4Nb6O17 Composite and its Photocatalytic Activity for Hydrogen Production

  • Liang, Yinghua;Shao, Meiyi;Liu, Li;Hu, Jinshan;Cui, Wenquan
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권4호
    • /
    • pp.1182-1190
    • /
    • 2014
  • $Cd_{1-x}Zn_xS$-sensitized $K_4Nb_6O_{17}$ composite photocatalysts (designated $Cd_{1-x}Zn_xS/K_4Nb_6O_{17}$) were prepared via a simple deposition-precipitation method. The samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive X-ray spectrometry (EDS), $N_2$ sorption, ultraviolet-visible light diffuse reflectance spectroscopy (UV-Vis DRS), photoluminescence measurements (PL), and X-ray photoelectron spectroscopy (XPS). The $Cd_{0.8}Zn_{0.2}S$ particles were scattered on the surface of $K_4Nb_6O_{17}$, and had a relatively uniform size distribution around 50 nm. The absorption edge of $K_4Nb_6O_{17}$ was shifted to the visible light region and the recombination of photo-generated electrons and holes suppressed after $Cd_{0.8}Zn_{0.2}S$ loading. The $Cd_{0.8}Zn_{0.2}S$(25 wt %)/$K_4Nb_6O_{17}$ composite possessed the highest photocatalytic activity for hydrogen production under visible light irradiation, evolving 8.278 mmol/g in 3 h. Recyclability tests were performed, and the composite photocatalysts were found to be fairly stable. The mechanism of charge separation between the photogenerated electrons and holes at the $Cd_{0.8}Zn_{0.2}S/K_4Nb_6O_{17}$ composite was discussed.

Study of Flexible Forming Process Involving the Use of Sectional Flexible Die for Sheet Material (분할가변금형을 이용한 박판의 가변성형공정 연구)

  • Heo, Seong-Chan;Ku, Tae-Wan;Song, Woo-Jin;Kim, Jeong;Kang, Beom-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제34권3호
    • /
    • pp.299-305
    • /
    • 2010
  • In general, the flexible forming die that has been used in the flexible forming process has the identical punch size; hence, its flexibility is relatively low because the range of allowable curvature radii is limited due to the uniform punch tip radius. Hence, a conceptual design of a sectional flexible die is presented for enhancing the flexibility of the forming process. Two punches of different sizes are used to configure the arbitrary forming surface. For a forming region with a relatively large curvature radius, a large punch array block is used; on the other hand, for the forming regions with small curvature radii, a small punch block is used. The cross-sectional profiles are compared with the target shape for evaluating the effectiveness of the process. Consequently, it is confirmed that the sectional flexible die can be used along with a combination of punch blocks of different sizes for manufacturing objective surfaces of complex shapes.

Effect of droplet length on a burning constant rate of suspended droplet (액적간격이 고정액적의 연소율상수에 미치는 영향에 관한 연구)

  • Han, Jae-Seob;Kim, Seon-Jin;Kim, Yoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • 제6권1호
    • /
    • pp.47-54
    • /
    • 2002
  • This paper presents the results of an experimental investigation on the combustion of single droplets and 1-D droplet arrays of jet A-1 fuel droplets in atmospheric pressure. Experimental results indicate that burning rate constants$({\kappa}_c)$ of jet A-1 fuel droplets were independent of initial droplet size as $0.915{mm}^2$/sec. It was acquired a general relationship expressing the variation of $d^2$ with time for droplet burning For 1-D droplet arrays $(l/d_o$=1.208{\sim}2.922)$/TEX>, the burning rate constant ${\kappa}_c$ decreased with decreasing droplet spacing $l/d_o$ and, The effect on combustion rate constant ${\kappa}_c$ was stronger to second fuel droplet than third fuel droplet with uniform droplet distance

Time Pickoff method using an Automatic Gain Control (자동 이득 조절(AGC) 기반의 Time pickoff 회로)

  • Lim, Han-Sang
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • 제48권4호
    • /
    • pp.80-85
    • /
    • 2011
  • A time-pickoff circuit used for time measurement suffers from a timing error due to the dependence of the generation time of a timing pulse on the size of the input signal, i.e., time walk. In this study, a time-pickoff method, which employs an automatic gain control (AGC) circuit, is proposed for reducing the timing error. The AGC circuit is added to the input of the comparator, and it renders the sizes of input signals of the comparator relatively uniform. The performance of the proposed time-pickoff method is analyzed using the SPICE simulation, and experiments are performed to confirm the analytical results. The measured time walk is reduced to 2.000 ns by 65% for input signals with a dynamic range of 20 dB as compared to a typical leading-edge discriminator.

Preparation and In Vitro Release of Ramose Chitosan-Based-5-Fluorouracil Microspheres

  • Li, He-Ping;Li, Hui;Wang, Zhou-Dong;Zhang, Juan-Juan;Deng, Man-Feng;Chen, San-Long
    • Journal of the Korean Chemical Society
    • /
    • 제57권1호
    • /
    • pp.88-93
    • /
    • 2013
  • In order to construct a controlled release system of drugs and to reduce toxic side effects of 5-fluorouracil, the novel ramose chitosan-based-5-fluorouracil microspheres (CS-FU-MS) were prepared. Firstly, using chitosan (CS) as carriers and 5-fluorouracil (5-FU) as a model drug, ramose chitosan-based-5-fluorouracil (CS-FU) was efciently synthesized by chemical crosslinking method through microwave irradiation, drug loading was 10.6%; Secondly, CS-FU-MS were prepared by CS-FU self-assembled under the dialysis conditions and the free 5-FU was encapsulated further at the same time. The size dispersivity of particles is uniform, and the average diameter of the CS-FU-MS was $4{\mu}m$. The drug encapsulation efficiency was 76.1%, and the drug loading was increased to 26.22%. CS-FU-MS maintain the zero-order release time in PBS (pH = 7.4) and HCl/KCl (pH = 1.2) dialysis medium was 40h and 34h respectively, and the cumulative release were 58.89% and 79.33% in 182 h. The results showed that CS-FU-MS have excellent sustained release properties.

DEVELOPMENT OF AN ASTRONOMICAL INFRARED PtSi CAMERA (천문관측용 PtSi 전하결합소자 적외선 카메라의 개발)

  • Hong, Seung-Su;;Gu, Bon-Cheol;Kim, Kwang-Tae;Kim, Chil-Yeong;Oh, Gap-Su;Lee, Myeong-Gyun;Lee, Hyeong-Mok;Kang, Yong-Woo;Park, Won-Gi
    • Publications of The Korean Astronomical Society
    • /
    • 제11권1호
    • /
    • pp.1-26
    • /
    • 1996
  • We have built a near-infrared imaging camera with a PtSi array detector manufactured by the Mitsubishi Company. The PtSi detector is sensitive in the wavelength range 1 to $5{\mu}m$. Quantum efficiency of PtSi is much lower than that of InSb and HgCdTe types. However, the PtSi array has advantages over the latter ones: (i)The read-out noise is very low; (ii)the characteristics of the array elements arc uniform and stable; (iii)it is not difficult to make a large PtSi array; and (iv) consequently the price is affordably low. The array used consists of $512{\times}512$ pixels and its size is $10.2\;mm{\times}13.3\;mm$. The filter wheel of the camera is equipped with J, H, K filters, and an aluminum plate for measuring the dark noise. The dewar is cooled with liquid nitrogen. We have adopted a method of installing the clock pattern and the observing softwares in the RAM, which Gill he easily used for other systems. We have developed a software with a pull-down menu for operating the camera and data acquisition. The camera has been tested by observing $\delta$ Orionis.

  • PDF

Forced Flow Dryout Heat Flux in a Stratified Debris Bed (성층 데브리층에서의 강제대류 드라이아웃 열유속)

  • Cha, Jong-Hee;Chung, Moon-Ki;Jin, Yong-Suk
    • Nuclear Engineering and Technology
    • /
    • 제20권2호
    • /
    • pp.112-119
    • /
    • 1988
  • The purpose of this work is to obtain the experimental data for the forced How dryout heat flux in a heat generating stratified debris bed which simulates the degraded nuclear reactor core after severe accident. The present observations were mainly focused on the effect of coolant mass flux on the dryout heat flux in the stratified debris bed which consists of several layers with selected particle sizes under constant bed depth and temperature of inlet coolant flow conditions. The following results were obtained from this experimental work: (1) The dryout heat flux in the stratified debris bed increases with increase of upward forcing mass flux of coolant. The similar trend of increase rate of dryout heat flux in the stratified bed was observed in the uniform particle size bed. (2) For the comparison of theoretical values and experimental data, the use of surface area mean diameter as a particle diameter was suitable for the calculation of dryout heat flux.

  • PDF